Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Urol Int ; : 1-4, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39102800

RESUMO

INTRODUCTION: Stress urinary incontinence (SUI) is a frequent, known complication following robot-assisted radical prostatectomy (RARP) for prostate cancer. Urethral shortening and reduced urethral support following RARP are contributing factors. CASE PRESENTATIONS: Herein, we describe a surgical approach using a novel absorbable urologic scaffold to mitigate SUI in 2 patients enrolled in an ongoing single-arm prospective study. The scaffold is designed to relieve the burden on the urinary sphincter by lengthening the effective urethra following RARP. The scaffold is placed at the anastomotic site, overlying the bladder neck and urethral stump following prostate removal and prior to the creation of the anastomosis. Both patients successfully underwent the prostatectomy and urologic scaffold placement with no reported perioperative complications. Neither patient suffered from early SUI following RARP as measured by pad weight and usage at 1 and 3 months following the procedure. CONCLUSION: Early experience with the absorbable urologic scaffold suggests it could safely and effectively prevent SUI following RARP. Early and long-term results derived from the ongoing prospective study with this device will better define its potential role in the prevention of SUI.

2.
J Gen Intern Med ; 36(1): 92-99, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32875501

RESUMO

BACKGROUND: Implementation methods of risk-stratified cancer screening guidance throughout a health care system remains understudied. OBJECTIVE: Conduct a preliminary analysis of the implementation of a risk-stratified prostate cancer screening algorithm in a single health care system. DESIGN: Comparison of men seen pre-implementation (2/1/2016-2/1/2017) vs. post-implementation (2/2/2017-2/21/2018). PARTICIPANTS: Men, aged 40-75 years, without a history of prostate cancer, who were seen by a primary care provider. INTERVENTIONS: The algorithm was integrated into two components in the electronic health record (EHR): in Health Maintenance as a personalized screening reminder and in tailored messages to providers that accompanied prostate-specific antigen (PSA) results. MAIN MEASURES: Primary outcomes: percent of men who met screening algorithm criteria; percent of men with a PSA result. Logistic repeated measures mixed models were used to test for differences in the proportion of individuals that met screening criteria in the pre- and post-implementation periods with age, race, family history, and PSA level included as covariates. KEY RESULTS: During the pre- and post-implementation periods, 49,053 and 49,980 men, respectively, were seen across 26 clinics (20.6% African American). The proportion of men who met screening algorithm criteria increased from 49.3% (pre-implementation) to 68.0% (post-implementation) (p < 0.001); this increase was observed across all races, age groups, and primary care clinics. Importantly, the percent of men who had a PSA did not change: 55.3% pre-implementation, 55.0% post-implementation. The adjusted odds of meeting algorithm-based screening was 6.5-times higher in the post-implementation period than in the pre-implementation period (95% confidence interval, 5.97 to 7.05). CONCLUSIONS: In this preliminary analysis, following implementation of an EHR-based algorithm, we observed a rapid change in practice with an increase in screening in higher-risk groups balanced with a decrease in screening in low-risk groups. Future efforts will evaluate costs and downstream outcomes of this strategy.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Neoplasias da Próstata , Adulto , Idoso , Algoritmos , Detecção Precoce de Câncer , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Atenção Primária à Saúde , Antígeno Prostático Específico , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/epidemiologia
3.
Optom Vis Sci ; 98(7): 846-853, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34328462

RESUMO

SIGNIFICANCE: High-, long-, and triple-jump athletic events may need to consider whether it is appropriate to group vision-impaired athletes in the same classification with loss of different visual functions, and a greater emphasis may need to be placed on the visual field (VF) within the current classification system used. PURPOSE: Athletes with vision impairment are grouped, based on their visual function, into one of three different classes (B1, B2, and B3, with B1 being the most severe). Athletes in class B2 have loss in visual acuity (VA; range, 1.50 to 2.60 logMAR) or VF (constricted to a diameter of <10°). The current study investigated how loss of different visual function (VA or VF) within the same class impacts jumping performance, a fundamental component in long-, triple-, and high-jump athletic events. METHODS: Ten subelite male athletes (age, 21.6 ± 0.96 years; height, 178.8 ± 2.97 cm; mass, 82.2 ± 10.58 kg) with normal vision who participate in athletics were recruited. Participants completed drop jumps in four vision conditions: habitual vision condition (Full), VA no better than 1.60 logMAR (B2-VA), VF restricted to <10° (B2-VF), and VA no better than 1.30 logMAR (B3-VA). RESULTS: Meaningful differences were observed between Full and B2-VF conditions. After rebound, vertical velocity at take-off was highest in Full condition (2.84 ± 0.35 m · s-1; 95% confidence interval [CI], 2.68 to 2.99 m · s-1) and was lowest in B2-VF condition (20% reduction; 2.32 ± 0.29 m · s-1; 95% CI, 2.16 to 2.48 m · s-1). Peak vertical jump height was highest in Full (0.42 ± 0.10 m; 95% CI, 0.38 to 0.46 m) and reduced by 40% in B2-VF (0.28 ± 0.07 m; 95% CI, 0.24 to 0.32 m). Minimal differences were found between Full and B2-VA, or B3-VA conditions. CONCLUSIONS: Jump performance is compromised in athletes with simulated vision impairment. However, decrements in performance seem specific to those with severely constricted VF. Those with reduced VA (in B2-VA and B3-VA classes) seem to produce performance comparable to those with normal vision.


Assuntos
Baixa Visão , Adulto , Atletas , Humanos , Masculino , Transtornos da Visão , Acuidade Visual , Campos Visuais , Adulto Jovem
4.
Can J Urol ; 24(5): 8982-8989, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28971784

RESUMO

INTRODUCTION: Contemporary clinical guidelines utilize the highest Gleason sum (HGS) in any one core on prostate biopsy to determine prostate cancer treatment. Here, we present a large discrepancy between prostate cancer risk stratified as high risk on biopsy and their pathology after radical prostatectomy. MATERIALS AND METHODS: We retrospectively reviewed 1424 men who underwent either open or robotic-assisted prostatectomy between 2004 and 2015. We analyzed 148 men who were diagnosed with HGS 8 on prostate biopsy. Biopsy and prostatectomy pathology were compared in aggregate and over 1 year time intervals. Chi-squared test, Fisher's exact test, Student's t-test, and Wilcoxon Rank-Sum test were used for statistical analysis. RESULTS: A total of 61.5% (91/148) of clinical HGS 8 diagnoses were downgraded on prostatectomy, with 58.8% (87/148) downgraded to Gleason 7 (Gleason 4 + 3 n = 59; Gleason 3 + 4 n = 28). Factors associated with downgrading include lower prostate-specific antigen (PSA) at biopsy (median 6.8 ng/mL versus 9.1 ng/mL, p < 0.001), number of Gleason 8 biopsy cores (median 1 versus 2, p < 0.02), presence of Gleason pattern 3 on biopsy cores (67.9% versus 44.8%, p < 0.03), pT2 staging (72.4% versus 55.1%, p < 0.04), positive margins (53.9% versus 69.1%, p < 0.04), extracapsular extension (53.4% versus 74.1%, p < 0.02), and smaller percent tumor (median 10% versus 15%, p < 0.004). CONCLUSION: The large percentage of pathology downgrading of biopsy-diagnosed HGS 8 suggests suboptimal risk-stratification that may lead to suboptimal treatment strategies and much patient distress. Our study adds great urgency to the efforts refining prostate cancer clinical assessment.


Assuntos
Próstata/patologia , Prostatectomia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Biópsia , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Período Pós-Operatório , Período Pré-Operatório , Estudos Retrospectivos , Medição de Risco
5.
J Urol ; 195(4 Pt 1): 998-1005, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26527514

RESUMO

PURPOSE: Standardized assessment of laparoscopic skill in urology is lacking. We investigated whether the AUA (American Urological Association) BLUS (Basic Laparoscopic Urologic Skills) skill tasks are valid to address this need. MATERIALS AND METHODS: This institutional review board approved study included 27 medical students, 42 urology residents, 18 fellows and 37 faculty urologists across 8 sites. Using the EDGE (Electronic Data Generation and Evaluation) device (Simulab, Seattle, Washington) 454 recordings were collected on peg transfer, pattern cutting, suturing and clip applying tasks, which together comprise the expert determined BLUS tasks. We collected synchronized video and tool motion data for each trial. For each task errors, time, path length, economy of motion, peak grasp force and EDGE score were collected. An expert panel of 5 faculty members performed GOALS (Global Objective Assessment of Laparoscopic Skills) evaluations on a representative subset of peg transfer and suturing skill tasks performed by 24 participants (IRR = 0.95). RESULTS: Demographically derived skill levels proved unsuitable to evaluate construct validity. Separation of mean scores by grouped skill levels was strongest for the suturing task. Objective motion metrics and errors supported construct validity vis-à-vis correlation with blinded expert video ratings (motion metrics R(2) = 0.95, p <0.01). Expert scores appeared to reward errors in suturing but not in block transfer. CONCLUSIONS: BLUS skill task performance scoring can discriminate among basic laparoscopic technical skill levels. Self-reported demographics are an unreliable source of determining laparoscopic technical skill.


Assuntos
Competência Clínica , Laparoscopia/normas , Urologia/normas , Humanos , Sociedades Médicas , Estados Unidos
6.
J Urol ; 195(6): 1859-65, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26778711

RESUMO

PURPOSE: The BLUS (Basic Laparoscopic Urologic Skills) consortium sought to address the construct validity of BLUS tasks and the wider problem of accurate, scalable and affordable skill evaluation by investigating the concordance of 2 novel candidate methods with faculty panel scores, those of automated motion metrics and crowdsourcing. MATERIALS AND METHODS: A faculty panel of surgeons (5) and anonymous crowdworkers blindly reviewed a randomized sequence of a representative sample of 24 videos (12 pegboard and 12 suturing) extracted from the BLUS validation study (454) using the GOALS (Global Objective Assessment of Laparoscopic Skills) survey tool with appended pass-fail anchors via the same web based user interface. Pre-recorded motion metrics (tool path length, jerk cost etc) were available for each video. Cronbach's alpha, Pearson's R and ROC with AUC statistics were used to evaluate concordance between continuous scores, and as pass-fail criteria among the 3 groups of faculty, crowds and motion metrics. RESULTS: Crowdworkers provided 1,840 ratings in approximately 48 hours, 60 times faster than the faculty panel. The inter-rater reliability of mean expert and crowd ratings was good (α=0.826). Crowd score derived pass-fail resulted in 96.9% AUC (95% CI 90.3-100; positive predictive value 100%, negative predictive value 89%). Motion metrics and crowd scores provided similar or nearly identical concordance with faculty panel ratings and pass-fail decisions. CONCLUSIONS: The concordance of crowdsourcing with faculty panels and speed of reviews is sufficiently high to merit its further investigation alongside automated motion metrics. The overall agreement among faculty, motion metrics and crowdworkers provides evidence in support of the construct validity for 2 of the 4 BLUS tasks.


Assuntos
Competência Clínica/estatística & dados numéricos , Crowdsourcing/estatística & dados numéricos , Laparoscopia/educação , Procedimentos Cirúrgicos Urológicos/educação , Área Sob a Curva , Humanos , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Gravação em Vídeo
7.
Int J Urol ; 23(8): 674-8, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27225958

RESUMO

OBJECTIVES: To study the effect of end-expiratory pressure used during anesthesia on blood loss during radical prostatectomy. METHODS: We evaluated 247 patients who underwent either radical retropubic prostatectomy or robot-assisted laparoscopic prostatectomy at a single institution from 2008 to 2013 by one of four surgeons. Patient characteristics were compared using t-tests, rank sum or χ(2) -tests as appropriate. The association between positive end-expiratory pressure and estimated blood loss was tested using linear regression. RESULTS: Patients were classified into high (≥4 cmH2 O) and low (≤1 cmH2 O) positive-end expiratory pressure groups. Estimated blood loss in radical retropubic prostatectomy was higher in the high positive end-expiratory pressure group (1000 mL vs 800 mL, P = 0.042). Estimated blood loss in robot-assisted laparoscopic prostatectomy was lower in the high positive end-expiratory pressure group (150 mL vs 250 mL, P = 0.015). After adjusting for other factors known to influence blood loss, a 5-cmH2 O increase in positive end-expiratory pressure was associated with a 34.9% increase in estimated blood loss (P = 0.030) for radical retropubic prostatectomy, and a 33.0% decrease for robot-assisted laparoscopic prostatectomy (P = 0.038). CONCLUSIONS: In radical retropubic prostatectomy, high positive end-expiratory pressure was associated with higher estimated blood loss, and the benefits of positive end-expiratory pressure should be weighed against the risk of increased estimated blood loss. In robot-assisted laparoscopic prostatectomy, high positive end-expiratory pressure was associated with lower estimated blood loss, and might have more than just pulmonary benefits.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Respiração com Pressão Positiva , Prostatectomia , Neoplasias da Próstata/cirurgia , Procedimentos Cirúrgicos Robóticos , Humanos , Laparoscopia , Masculino
8.
J Urol ; 193(4): 1270-4, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25261805

RESUMO

PURPOSE: The management of upper urinary tract stones in patients with spina bifida is challenging but poorly described in the literature. We compared urolithiasis interventions and related complications in patients with spina bifida to those in other stone formers using a national database. MATERIALS AND METHODS: We retrospectively reviewed the NIS to identify hospital admissions for renal and ureteral stones from 1998 to 2011. We used ICD-9-CM codes to identify urological interventions, including shock wave lithotripsy, ureteroscopy, percutaneous nephrolithotomy and ureteral stent placement. NSQIP data were used to identify postoperative complications. RESULTS: We identified 4,287,529 weighted stone hospital admissions, including 12,315 (0.3%) of patients with spina bifida. Compared to those without spina bifida the patients with spina bifida who had urolithiasis were significantly younger (mean age 34 vs 53 years), more likely to have public insurance (72% vs 44%) and renal vs ureteral calculi (81% vs 58%), and undergo percutaneous nephrolithotomy (27% vs 8%). After adjusting for age, insurance, comorbidity, treatment year, surgery type, stone location and hospital factors patients with spina bifida were more likely to have urinary tract infections (OR 2.5), urinary complications (OR 3.1), acute renal failure (OR 1.9), respiratory complications (OR 2.0), pneumonia (OR 1.5), respiratory insufficiency (OR 3.2), prolonged mechanical ventilation (OR 3.2), sepsis (OR 2.7), pulmonary embolism (OR 3.0), cardiac complications (OR 2.4) and bleeding (OR 1.6). CONCLUSIONS: Compared to those without spina bifida the patients with spina bifida who were hospitalized for urolithiasis were younger, and more likely to have renal stones and undergo percutaneous nephrolithotomy. Urolithiasis procedures in patients with spina bifida were associated with a significantly higher risk of in-hospital postoperative complications.


Assuntos
Cálculos Renais/complicações , Cálculos Renais/cirurgia , Complicações Pós-Operatórias/epidemiologia , Disrafismo Espinal/complicações , Cálculos Ureterais/complicações , Cálculos Ureterais/cirurgia , Adulto , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Estados Unidos , Procedimentos Cirúrgicos Urológicos/métodos
9.
J Urol ; 194(2): 413-7, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25728906

RESUMO

PURPOSE: During ureteroscopy ureteral balloon dilation may be necessary to allow for passage of endoscopic instruments or access sheaths. We assessed the efficacy and complications associated with ureteral balloon dilation. MATERIALS AND METHODS: We retrospectively reviewed the records at 2 institutions from 2000 to 2012 to identify patients who underwent ureteral balloon dilation during ureteroscopic treatment of upper tract stones. An 18Fr balloon dilator was used in all cases. Patients with documented ureteral stricture, radiation therapy or urothelial cancer were excluded from analysis. Primary outcomes were the stone-free rate, operative complications, balloon dilation failure and the postoperative ureteral stricture rate. Complications were divided into intraoperative and postoperative groups according to the Satava and Clavien-Dindo classifications, respectively. RESULTS: A total of 151 patients fulfilled study criteria. Median followup was 12 months. The stone-free rate was 72% and median time to first postoperative imaging was 2.8 months. Balloon dilation failed in only 8 patients (5%). Eight intraoperative ureteral perforations (5%) were identified, which were managed by a ureteral stent in 7 patients and a percutaneous tube in 1. Endoscopic re-treatment was required in 4 patients with Satava 2b postoperative complications. The postoperative complication rate was 8% (11 cases). A single ureteral stricture was attributable to balloon dilation. CONCLUSIONS: In this contemporary review balloon dilation of the ureter before endoscopic treatment of stone disease was associated with a high success rate and few complications. Ureteral balloon dilation may decrease the need for a secondary procedure in patients undergoing ureteroscopy to manage proximal ureteral and intrarenal stones.


Assuntos
Dilatação/métodos , Obstrução Ureteral/terapia , Ureteroscopia/métodos , Cálculos Urinários/terapia , Cateterismo Urinário , Adulto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Ureter , Obstrução Ureteral/etiologia , Cálculos Urinários/complicações
10.
J Urol ; 194(4): 878-85, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26055822

RESUMO

PURPOSE: There is rising concern over the increasing amount of patient radiation exposure from diagnostic imaging and medical procedures. Patients with nephrolithiasis are at potentially significant risk for radiation exposure due to the need for imaging to manage recurrent stone disease. We reviewed the literature in an attempt to better characterize actual risks and discussed methods to reduce radiation exposure for adult patients with nephrolithiasis. MATERIALS AND METHODS: A PubMed search was performed using the key words nephrolithiasis, stones, radiation, fluoroscopy, ureteroscopy, percutaneous nephrolithotomy, computerized tomography and shock wave lithotripsy. Additional citations were identified by reviewing reference lists of pertinent articles. RESULTS: A total of 50 relevant articles were included in this review. Patients with a first time acute stone event are exposed to a significant amount of radiation. Most radiation is from computerized tomography. Patients undergoing percutaneous nephrolithotomy are exposed to an equal or greater amount of radiation than they received from computerized tomography. Risk factors for increased exposure during percutaneous nephrolithotomy include obesity, multiple tracts and a larger stone burden. Ureteroscopy exposes patients to approximately the same amount of radiation as plain x-ray of the kidneys, ureters and bladder. Risk factors for increased exposure during ureteroscopy include obesity and ureteral dilation. During shock wave lithotripsy the amount of radiation exposure is not well characterized. Interventions to reduce exposure to patients include using ultrasound when possible and implementing low dose computerized tomography protocols. The as low as reasonably achievable principle of radiation exposure should always be followed when fluoroscopy is performed. The use of an air retrograde pyelogram may also reduce exposure during percutaneous nephrolithotomy. Fluoroscopy time during ureteroscopy may be decreased by a laser guided C-arm, a dedicated C-arm technician, stent placement under direct vision and tactile feedback to help guide wire placement. CONCLUSIONS: Patients with nephrolithiasis are at significant risk for increased radiation exposure from the imaging and fluoroscopy used during treatment. The true risks of low radiation exposure remain uncertain. It is important to be aware of these risks to provide better counseling for patients. Urologists must also be familiar with techniques to decrease radiation exposure for patients with nephrolithiasis.


Assuntos
Nefrolitíase/diagnóstico , Nefrolitíase/terapia , Exposição à Radiação , Diagnóstico por Imagem/efeitos adversos , Humanos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Tomografia Computadorizada por Raios X/efeitos adversos
11.
BJU Int ; 114(3): 404-11, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24712851

RESUMO

OBJECTIVE: To evaluate whether body mass index (BMI) has an impact on the outcomes of tubeless percutaneous nephrolithotomy (PCNL). PATIENTS AND METHODS: We retrospectively reviewed patients who underwent tubeless PCNL at our institution from 2006 to 2011. Specifically, stone-free rates, complications, and hospital length of stay (LOS) were assessed. Patients were divided into four groups based on BMI: <25, 25-29.9, 30-34.9 and ≥35 kg/m(2) . Baseline characteristics and outcomes were compared between BMI groups. Multivariable logistic regressions were used to evaluate the independent contribution of BMI as a predictor of outcomes. RESULTS: We identified 268 patients who fulfilled study requirements. The overall stone-free and complication rates were 52.5% and 19.0%, respectively. Minor and severe complication comprised 10.4% and 8.6%, respectively. Univariate and multivariable analyses showed no association between BMI and stone-free or complication rates. However, patients with a normal BMI had significantly higher transfusion rates (P = 0.005), and were significantly more likely to have a prolonged LOS (≥2 days), when compared with an overweight BMI (P = 0.032) CONCLUSIONS: BMI did not impact the stone-free, or complication rates of tubeless PCNL. Normal BMI was found to be a risk factor for prolonged LOS, which may be due to an increase in clinically significant bleeding in this patient population. Tubeless PCNL appears to be a safe and effective procedure for the treatment of complex renal calculi, independent of BMI.


Assuntos
Transfusão de Sangue/estatística & dados numéricos , Índice de Massa Corporal , Hemostáticos/uso terapêutico , Cálculos Renais/cirurgia , Tempo de Internação/estatística & dados numéricos , Nefrostomia Percutânea/efeitos adversos , Sobrepeso , Hemorragia Pós-Operatória/etiologia , Adulto , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Nefrostomia Percutânea/métodos , Hemorragia Pós-Operatória/prevenção & controle , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
12.
BJU Int ; 113(6): 854-63, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24119037

RESUMO

To discuss the use of renal mass biopsy (RMB) for small renal masses (SRMs), formulate technical aspects, outline potential pitfalls and provide recommendations for the practicing clinician. The meeting was conducted as an informal consensus process and no scoring system was used to measure the levels of agreement on the different topics. A moderated general discussion was used as the basis for consensus and arising issues were resolved at this point. A consensus was established and lack of agreement to topics or specific items was noted at this point. Recommended biopsy technique: at least two cores, sampling different tumour regions with ultrasonography being the preferred method of image guidance. Pathological interpretation: 'non-diagnostic samples' should refer to insufficient material, inconclusive and normal renal parenchyma. For non-diagnostic samples, a repeat biopsy is recommended. Fine-needle aspiration may provide additional information but cannot substitute for core biopsy. Indications for RMB: biopsy is recommended in most cases except in patients with imaging or clinical characteristics indicative of pathology (syndromes, imaging characteristics) and cases whereby conservative management is not contemplated. RMB is recommended for active surveillance but not for watchful-waiting candidates. We report the results of an international consensus meeting on the use of RMB for SRMs, defining the technique, pathological interpretation and indications.


Assuntos
Nefropatias/patologia , Neoplasias Renais/patologia , Biópsia por Agulha/métodos , Biópsia por Agulha/normas , Humanos , Reprodutibilidade dos Testes
13.
J Urol ; 189(6): 2142-6, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23261481

RESUMO

PURPOSE: Patients with recurrent nephrolithiasis are often evaluated and followed with computerized tomography. Obesity is a risk factor for nephrolithiasis. We evaluated the radiation dose of computerized tomography in obese and nonobese adults. MATERIALS AND METHODS: We scanned a validated, anthropomorphic male phantom according to our institutional renal stone evaluation protocol. The obese model consisted of the phantom wrapped in 2 Custom Fat Layers (CIRS, Norfolk, Virginia), which have been verified to have the same radiographic tissue density as fat. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations in the phantoms to measure organ specific radiation doses. The nonobese and obese models have an approximate body mass index of 24 and 30 kg/m(2), respectively. Three runs of renal stone protocol computerized tomography were performed on each phantom under automatic tube current modulation. Organ specific absorbed doses were measured and effective doses were calculated. RESULTS: The bone marrow of each model received the highest dose and the skin received the second highest dose. The mean ± SD effective dose for the nonobese and obese models was 3.04 ± 0.34 and 10.22 ± 0.50 mSv, respectively (p <0.0001). CONCLUSIONS: The effective dose of stone protocol computerized tomography in obese patients is more than threefold higher than the dose in nonobese patients using automatic tube current modulation. The implication of this finding extends beyond the urological stone population and adds to our understanding of radiation exposure from medical imaging.


Assuntos
Obesidade/complicações , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Carga Corporal (Radioterapia) , Índice de Massa Corporal , Humanos , Masculino , Modelos Teóricos , Nefrolitíase/diagnóstico por imagem , Monitoramento de Radiação/métodos , Recidiva , Valores de Referência , Tomografia Computadorizada por Raios X/métodos
14.
J Urol ; 190(6): 2117-23, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23764073

RESUMO

PURPOSE: Computerized tomography use increased exponentially in the last 3 decades, and it is commonly used to evaluate many urological conditions. Ionizing radiation exposure from medical imaging is linked to the risk of malignancy. We measured the organ and calculated effective doses of different studies to determine whether the dose-length product method is an accurate estimation of radiation exposure. MATERIALS AND METHODS: An anthropomorphic male phantom validated for human organ dosimetry measurements was used to determine radiation doses. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations to measure specific organ doses. For each study the phantom was scanned 3 times using our institutional protocols. Organ doses were measured and effective doses were calculated on dosimetry. Effective doses measured by a metal oxide semiconductor field effect transistor dosimeter were compared to calculated effective doses derived from the dose-length product. RESULTS: The mean±SD effective dose on dosimetry for stone protocol, chest and abdominopelvic computerized tomography, computerized tomography urogram and renal cell carcinoma protocol computerized tomography was 3.04±0.34, 4.34±0.27, 5.19±0.64, 9.73±0.71 and 11.42±0.24 mSv, respectively. The calculated effective dose for these studies Was 3.33, 2.92, 5.84, 9.64 and 10.06 mSv, respectively (p=0.8478). CONCLUSIONS: The effective dose varies considerable for different urological computerized tomography studies. Renal stone protocol computerized tomography shows the lowest dose, and computerized tomography urogram and the renal cell carcinoma protocol accumulate the highest effective doses. The calculated effective dose derived from the dose-length product is a reasonable estimate of patient radiation exposure.


Assuntos
Técnicas de Diagnóstico Urológico/normas , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/normas , Humanos , Masculino
15.
Urol Int ; 91(3): 340-4, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23942388

RESUMO

OBJECTIVE: To compare the risks of fever from different lithotrites after percutaneous nephrolithotomy (PNL). MATERIALS AND METHODS: The Clinical Research Office of the Endourological Society (CROES) PNL database is a prospective, multi-institutional, international PNL registry. Of 5,803 total patients, 4,968 received preoperative antibiotics, were supplied with complete information and included in this analysis. The lithotrites assessed included no fragmentation, ultrasonic, laser, pneumatic and combination ultrasonic/pneumatic. Risk of fever was estimated using multivariate logistic regression with adjustment for diabetes, steroid use, a history of positive urine culture, the presence of staghorn calculi or preoperative nephrostomy, stone burden and lithotrite. RESULTS: The overall fever rate was 10%. Pneumatic lithotrites were used in 43% of the cohort, followed by ultrasonic (24%), combination ultrasonic/pneumatic (17.3%), no fragmentation (8.4%) and laser (7.3%). Fever rates were no different between patients who underwent no or any fragmentation (p = 0.117), nor among patients when stratified by lithotrite (p = 0.429). On multivariate analysis, fragmentation was not significantly associated with fever [Odds Ratio (OR) 1.17, p = 0.413], while diabetes (OR 1.32, p = 0.048), positive urine culture (OR 2.08, p < 0.001), staghorn calculi (OR 1.80, p < 0.001) and nephrostomy (OR 1.65, p < 0.001) increased fever risk. Fever risk among lithotrites did not differ (p ≥ 0.128). CONCLUSIONS: Risk of post-PNL fever was not significantly different among the various lithotrites used in the CROES PNL study.


Assuntos
Febre/etiologia , Cálculos Renais/cirurgia , Litotripsia/instrumentação , Litotripsia/métodos , Nefrostomia Percutânea/métodos , Complicações Pós-Operatórias/etiologia , Adulto , Antibioticoprofilaxia , Estudos de Coortes , Feminino , Febre/epidemiologia , Humanos , Cooperação Internacional , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Sistema de Registros , Análise de Regressão , Risco
16.
Artigo em Inglês | MEDLINE | ID: mdl-38063551

RESUMO

The duplication of chromosome 21, as evidenced in Down Syndrome (DS), has been linked to contraindications to health, such as chronotropic and respiratory incompetence, neuromuscular conditions, and impaired cognitive functioning. The purpose of this study was to examine the effects of eight weeks of prescribed exercise and/or cognitive training on the physical and cognitive health of adults with DS. Eighty-three participants (age 27.1 ± 8.0 years) across five continents participated. Physical fitness was assessed using a modified version of the six-minute walk test (6MWT), while cognitive and executive functions were assessed using the Corsi block test, the Sustained-Attention-To-Response Task (SART), and the Stroop task (STROOP). All were completed pre- and post-intervention. Participants were assigned to eight weeks of either exercise (EXE), 3 × 30 min of walking/jogging per week, cognitive training (COG) 6 × ~20 min per week, a combined group (COM), and a control group (CON) engaging in no intervention. 6MWT distance increased by 11.4% for EXE and 9.9% for COM (p < 0.05). For SART, there were positive significant interactions between the number of correct and incorrect responses from pre- to post-intervention when participants were asked to refrain from a response (NO-GO-trials) across all experimental groups (p < 0.05). There were positive significant interactions in the number of correct, incorrect, and timeout incompatible responses for STROOP in EXE, COG, and COM (p < 0.05). Walking generated a cognitive load attributed to heightened levels of vigilance and decision-making, suggesting that exercise should be adopted within the DS community to promote physical and cognitive well-being.


Assuntos
Síndrome de Down , Terapia por Exercício , Adulto , Humanos , Adulto Jovem , Síndrome de Down/terapia , Exercício Físico/psicologia , Cognição/fisiologia , Força Muscular/fisiologia
17.
J Urol ; 188(3): 851-5, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22819410

RESUMO

PURPOSE: Malignant ureteral obstruction often necessitates chronic urinary diversion and is associated with high rates of failure with traditional ureteral stents. We evaluated the outcomes of a metallic stent placed for malignant ureteral obstruction and determined the impact of risk factors previously associated with increased failure rates of traditional stents. MATERIALS AND METHODS: Patients undergoing placement of the metallic Resonance® stent for malignant ureteral obstruction at an academic referral center were identified retrospectively. Stent failure was defined as unplanned stent exchange or nephrostomy tube placement for signs or symptoms of recurrent ureteral obstruction (recurrent hydroureteronephrosis or increasing creatinine). Predictors of time to stent failure were assessed using Cox regression. RESULTS: A total of 37 stents were placed in 25 patients with malignant ureteral obstruction. Of these stents 12 (35%) were identified to fail. Progressive hydroureteronephrosis and increasing creatinine were the most common signs of stent failure. Three failed stents had migrated distally and no stents required removal for recurrent infection. Patients with evidence of prostate cancer invading the bladder at stent placement were found to have a significantly increased risk of failure (HR 6.50, 95% CI 1.45-29.20, p = 0.015). Notably symptomatic subcapsular hematomas were identified in 3 patients after metallic stent placement. CONCLUSIONS: Failure rates with a metallic stent are similar to those historically observed with traditional polyurethane based stents in malignant ureteral obstruction. The invasion of prostate cancer in the bladder significantly increases the risk of failure. Patients should be counseled and observed for subcapsular hematoma formation with this device.


Assuntos
Stents , Obstrução Ureteral/cirurgia , Neoplasias Abdominais/complicações , Ligas de Cromo , Feminino , Humanos , Masculino , Molibdênio , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento , Obstrução Ureteral/etiologia
18.
J Urol ; 187(3): 920-4, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22264465

RESUMO

PURPOSE: We measured organ specific radiation dose rates and determined effective dose rates during simulated ureteroscopy using a validated model. To calculate the effective dose, patients were exposed to ureteroscopic management of stones at our institution. MATERIALS AND METHODS: A validated anthropomorphic male phantom was placed on a fluoroscopy table and underwent simulated ureteroscopy. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ sites in the phantom and used to measure organ specific radiation doses. These dose rates were multiplied by the appropriate tissue weighting factor and summed to calculate effective dose rates. Also, we retrospectively reviewed the charts of patients who underwent ureteroscopy at our institution. A total of 30 nonobese males with data on fluoroscopy time were included in analysis. The median effective dose was determined by multiplying median fluoroscopy time by the effective dose rate. RESULTS: The skin entrance was exposed to the highest absorbed dose rate, followed by the small intestine (mean ± SD 0.3286 ± 0.0054 and 0.1882 ± 0.0194 mGy per second, respectively). The mean effective dose rate was 0.024 ± 0.0019 mSv per second. Median fluoroscopy time was 46.95 seconds (range 12.9 to 298.8). The median effective dose was 1.13 mSv (range 0.31 to 7.17). CONCLUSIONS: The fluoroscopy used during ureteroscopy contributes to overall radiation exposure in patients with nephrolithiasis. Nonobese males are exposed to a median of 1.13 mSv during ureteroscopy, similar to that of abdominopelvic x-ray. More data are needed to determine clinical implications but urologists must be aware and decrease patient radiation during ureteroscopy.


Assuntos
Doses de Radiação , Ureteroscopia , Urolitíase/diagnóstico por imagem , Carga Corporal (Radioterapia) , Humanos , Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Radiografia , Estudos Retrospectivos , Fatores de Tempo , Ureter/efeitos da radiação , Bexiga Urinária/efeitos da radiação
19.
Sports Health ; 14(5): 740-746, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35104417

RESUMO

BACKGROUND: Muscle weakness is common after injury in athletes and in the presence of hip pathology. It will cause abnormal hip biomechanics and can predict future injury. However, objective measurement of hip muscle strength is difficult to perform accurately and reliably. Therefore, it is challenging to determine when an athlete has returned to preinjury levels of strength. In addition, there is currently no standardized method of obtaining measurements, which prevents the data being compared or shared between research centers. PURPOSE: The purpose of this study is to comprehensively assess the inter- and intraobserver reliability of our standardized muscle strength measurement protocol. STUDY DESIGN: Descriptive laboratory study. LEVEL OF EVIDENCE: Level 3, inception cohort study. METHODS: A total of 16 healthy male volunteers (age = 28.3 ± 7.9 years) were recruited. Those with a previous history of hip injuries or disorders were excluded. These volunteers underwent strength testing according to the Cambridge Protocol on 4 separate occasions, performed by 2 independent assessors. Maximal voluntary contractions, fatigue torque fluctuations, and electromyography measurements were recorded. Intra- and interobserver reliability was assessed using intraclass correlation coefficient (ICC). RESULTS: Good-to-excellent correlation was seen for both intra- and interobserver reliability across almost all hip movements for maximal contractions: ICC ranged 0.78 to 0.93 and 0.78 to 0.96, respectively. The standard error of the mean for all hip movements was also extremely low at 2% to 3%. CONCLUSION: The Cambridge Protocol is a highly reliable method for objective measurement of hip muscle strength. We recommend future studies use this protocol, or the principles underpinning it, to enable data sharing and comparison across different studies. CLINICAL RELEVANCE: This is a description and analysis of hip muscle strength measurement. If widely used, it will allow for accurate and objective strength assessment and closer monitoring of hip injuries and pathology.


Assuntos
Lesões do Quadril , Força Muscular , Adulto , Estudos de Coortes , Eletromiografia , Humanos , Masculino , Força Muscular/fisiologia , Dinamômetro de Força Muscular , Músculo Esquelético/fisiologia , Reprodutibilidade dos Testes , Adulto Jovem
20.
J Urol ; 185(3): 910-4, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21239024

RESUMO

PURPOSE: Low dose noncontrast computerized tomography is becoming a common imaging tool to diagnose urolithiasis. We investigated its usefulness as a diagnostic tool in the outpatient setting. MATERIALS AND METHODS: A total of 62 patients with suspected urolithiasis underwent standard renal stone protocol computerized tomography with a tube current of 160 mA. Images were modified by adding image noise to simulate tube currents of 70, 100 and 130 mA. Three urologists independently interpreted the original and simulated dose scans for stone number, location and associated signs of obstruction. In addition, the investigators rated the ease of interpreting the scans and their overall level of confidence. RESULTS: There were no statistically significant differences in interobserver and intra-observer variability for stone detection or obstruction signs except significant interobserver variability in hydronephrosis and intra-observer variability in stranding categories. Each 1 mm increase in stone size increased the likelihood of a concordant response 3.55, 2.7 and 2-fold when reducing the tube current level by 19%, 38% and 56%, respectively (p=0.001, 0.008 and 0.021, respectively). Multiple stones or index stone location were not associated with agreement. The overall level of confidence decreased with lower simulated doses, particularly in the bony pelvis (p<0.02). CONCLUSIONS: Low dose computerized tomography may serve as an effective tool in the setting of the urology clinic in patients with urolithiasis. This imaging tool can better assess urolithiasis and associated obstruction than plain abdominal radiographs, but it may be problematic with small stones (less than 2 mm) and evidence of distal ureteral obstruction. Its effectiveness as a long-term followup tool requires further prospective trials.


Assuntos
Cálculos Renais/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X , Cálculos Ureterais/diagnóstico por imagem , Humanos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA