Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
AAPS PharmSciTech ; 24(1): 18, 2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36526853

RESUMO

Visible protein-like particle standards may improve visual inspection and/or appearance testing practices used in the biotechnology industry. They may improve assay performance resulting in better alignment and more standardized training among different companies. The National Institute of Standards and Technology (NIST) has conducted an interlaboratory study to test whether the standards under development mimic typical proteinaceous particles found in biotherapeutics and if they can be implemented during the visual inspection process. Fourteen organizations from industry and government have participated. A total of 20 labs from these 14 organizations participated with analysts from 6 formulation, 7 analytical, 4 quality control, and 3 manufacturing labs. The circulated samples consisted of abraded ethylene tetrafluoroethylene (ETFE) particles or photolithographic particles. The results consist of qualitative ratings, which varied substantially among organizations and within labs. Polydisperse ETFE particle suspensions, containing particles enriched in greater than 150 µm in size, were rated more favorably than the photolithographic particles by formulation and analytical scientists. The largest monodisperse photolithographic particles (approximately 300 µm in size) were favored equally compared to ETFE by all scientists. Solution modifications to decrease the settling rate or to alter optical properties of the ETFE solutions yielded lower ratings by the analysts. Both particle types received mixed ratings for their usability and for their application for visual inspection and for training purposes. Industry feedback will assist NIST in developing reference material(s) for visible protein-like particles.


Assuntos
Proteínas , Tamanho da Partícula , Padrões de Referência , Controle de Qualidade
2.
Crit Care ; 23(1): 375, 2019 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-31775830

RESUMO

BACKGROUND: In ARDS patients, changes in respiratory mechanical properties and ventilatory settings can cause incomplete lung deflation at end-expiration. Both can promote dynamic hyperinflation and intrinsic positive end-expiratory pressure (PEEP). The aim of this study was to investigate, in a large population of ARDS patients, the presence of intrinsic PEEP, possible associated factors (patients' characteristics and ventilator settings), and the effects of two different external PEEP levels on the intrinsic PEEP. METHODS: We made a secondary analysis of published data. Patients were ventilated with a tidal volume of 6-8 mL/kg of predicted body weight, sedated, and paralyzed. After a recruitment maneuver, a PEEP trial was run at 5 and 15 cmH2O, and partitioned mechanics measurements were collected after 20 min of stabilization. Lung computed tomography scans were taken at 5 and 45 cmH2O. Patients were classified into two groups according to whether or not they had intrinsic PEEP at the end of an expiratory pause. RESULTS: We enrolled 217 sedated, paralyzed patients: 87 (40%) had intrinsic PEEP with a median of 1.1 [1.0-2.3] cmH2O at 5 cmH2O of PEEP. The intrinsic PEEP significantly decreased with higher PEEP (1.1 [1.0-2.3] vs 0.6 [0.0-1.0] cmH2O; p < 0.001). The applied tidal volume was significantly lower (480 [430-540] vs 520 [445-600] mL at 5 cmH2O of PEEP; 480 [430-540] vs 510 [430-590] mL at 15 cmH2O) in patients with intrinsic PEEP, while the respiratory rate was significantly higher (18 [15-20] vs 15 [13-19] bpm at 5 cmH2O of PEEP; 18 [15-20] vs 15 [13-19] bpm at 15 cmH2O). At both PEEP levels, the total airway resistance and compliance of the respiratory system were not different in patients with and without intrinsic PEEP. The total lung gas volume and lung recruitability were also not different between patients with and without intrinsic PEEP (respectively 961 [701-1535] vs 973 [659-1433] mL and 15 [0-32] % vs 22 [0-36] %). CONCLUSIONS: In sedated, paralyzed ARDS patients without a known obstructive disease, the amount of intrinsic PEEP during lung-protective ventilation is negligible and does not influence respiratory mechanical properties.


Assuntos
Fator Intrínseco , Respiração com Pressão Positiva/classificação , Síndrome do Desconforto Respiratório/fisiopatologia , Idoso , Análise de Variância , Gasometria , Feminino , Humanos , Pulmão/fisiopatologia , Complacência Pulmonar/fisiologia , Masculino , Pessoa de Meia-Idade , Mecânica Respiratória , Estudos Retrospectivos , Volume de Ventilação Pulmonar/fisiologia
3.
PLoS One ; 19(9): e0310077, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39298371

RESUMO

BACKGROUND: COVID-19 patients may exhibit neurological symptoms due to direct viral damage, systemic inflammatory syndrome, or treatment side effects. Mechanical ventilation in patients with severe respiratory failure often requires sedation and neuromuscular blockade, hindering thorough clinical examinations. This study aimed to investigate neurological involvement through clinical and noninvasive techniques and to detect signs of intracranial hypertension in these patients. METHOD: We conducted a prospective observational study on mechanically ventilated COVID-19 adult patients admitted to our ICU, following standard of care protocols for ventilation and permissive hypercapnia. Data were collected at three time points: admission day (T1), day seven (T7), and day fourteen (T14). At each time point, patients underwent multimodal noninvasive neurological monitoring, including clinical examination, pupillary reactivity, transcranial color doppler of the middle cerebral artery (MCA), and optic nerve sheath diameter (ONSD) assessed via ultrasound (US). Head computer tomography (CT) was performed at T1 and T14. A limited subset of patients had a follow-up examination six months after ICU discharge. RESULTS: Seventy-nine patients were recruited; most were under deep sedation and neuromuscular blockade at T1. Pupillary size, symmetry, and reactivity were normal, as was the MCA mean velocity. However, ONSD, assessed by both US and CT, appeared enlarged, suggesting raised intracranial pressure (ICP). In a subgroup of 12 patients, increased minute ventilation was associated with a significant decrease in US-ONSD, corresponding to a drop in paCO2. At follow-up, twelve patients showed no long-term neurological sequelae, and US-ONSD was decreased in all of them. DISCUSSION AND CONCLUSIONS: In this cohort, enlarged ONSD was detected during non-invasive neurological monitoring, suggesting a raised ICP, with hypercapnia playing a prominent role. Further studies are needed to explore ONSD behavior in other samples of mechanically ventilated, hypercapnic patients.


Assuntos
COVID-19 , Hipertensão Intracraniana , Insuficiência Respiratória , Humanos , COVID-19/complicações , COVID-19/terapia , Masculino , Feminino , Pessoa de Meia-Idade , Hipertensão Intracraniana/diagnóstico por imagem , Estudos Prospectivos , Idoso , Insuficiência Respiratória/terapia , Insuficiência Respiratória/etiologia , Respiração Artificial , SARS-CoV-2/isolamento & purificação , Nervo Óptico/diagnóstico por imagem , Nervo Óptico/patologia , Adulto , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/fisiopatologia , Unidades de Terapia Intensiva
4.
J Crit Care ; 68: 89-95, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34952476

RESUMO

PURPOSE: Several different tools have been developed to integrate the clinical and biochemical nutritional evaluations in critical care patients. Aims of this study were to evaluate the changes in the Bioelectrical Impedance Vector Analysis (BIVA) and ultrasonographic features of the diaphragm (DTee) and rectus femoris (RFCSA) during the first week of ICU stay. MATERIALS AND METHODS: Ninety-six adult mechanically ventilated patients enrolled within 24 h after the admission to the ICU (T1). RFCSA and diaphragm end-expiratory thickness were measured, as well as BIVA parameters. Anthropometric data and biochemical parameters were collected. The measurements were repeated on the 3rd (T3) and 7th (T7) days of ICU stay. RESULTS: During the study period, the phase angle significantly decreased by 21%, reactance by 27%, and resistance by 11%. Both RFCSA and DTee significantly decreased, while neither were correlated to any BIVA parameter. DTee was considerably higher in survivors vs. non-survivors. CONCLUSIONS: Body composition is significantly modified after one week of ICU stay. BIVA may be useful in the definition of hydration state, while it does not seem to track muscle mass. Different temporal trends of specific BIVA and muscle ultrasound parameters were found in patients with high or low severity of illness.


Assuntos
Cuidados Críticos , Estado Terminal , Adulto , Composição Corporal , Impedância Elétrica , Humanos , Ultrassonografia
5.
Front Immunol ; 13: 1070379, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36591311

RESUMO

Background: Coronavirus disease 2019 (COVID-19) caused by SARS-CoV-2 infection is associated with disorders affecting the peripheral and the central nervous system. A high number of patients develop post-COVID-19 syndrome with the persistence of a large spectrum of symptoms, including neurological, beyond 4 weeks after infection. Several potential mechanisms in the acute phase have been hypothesized, including damage of the blood-brain-barrier (BBB). We tested weather markers of BBB damage in association with markers of brain injury and systemic inflammation may help in identifying a blood signature for disease severity and neurological complications. Methods: Blood biomarkers of BBB disruption (MMP-9, GFAP), neuronal damage (NFL) and systemic inflammation (PPIA, IL-10, TNFα) were measured in two COVID-19 patient cohorts with high disease severity (ICUCovid; n=79) and with neurological complications (NeuroCovid; n=78), and in two control groups free from COVID-19 history, healthy subjects (n=20) and patients with amyotrophic lateral sclerosis (ALS; n=51). Samples from COVID-19 patients were collected during the first and the second wave of COVID-19 pandemic in Lombardy, Italy. Evaluations were done at acute and chronic phases of the COVID-19 infection. Results: Blood biomarkers of BBB disruption and neuronal damage are high in COVID-19 patients with levels similar to or higher than ALS. NeuroCovid patients display lower levels of the cytokine storm inducer PPIA but higher levels of MMP-9 than ICUCovid patients. There was evidence of different temporal dynamics in ICUCovid compared to NeuroCovid patients with PPIA and IL-10 showing the highest levels in ICUCovid patients at acute phase. On the contrary, MMP-9 was higher at acute phase in NeuroCovid patients, with a severity dependency in the long-term. We also found a clear severity dependency of NFL and GFAP levels, with deceased patients showing the highest levels. Discussion: The overall picture points to an increased risk for neurological complications in association with high levels of biomarkers of BBB disruption. Our observations may provide hints for therapeutic approaches mitigating BBB disruption to reduce the neurological damage in the acute phase and potential dysfunction in the long-term.


Assuntos
Esclerose Lateral Amiotrófica , COVID-19 , Doenças do Sistema Nervoso , Humanos , COVID-19/complicações , Barreira Hematoencefálica , Interleucina-10 , Metaloproteinase 9 da Matriz , SARS-CoV-2 , Pandemias , Síndrome de COVID-19 Pós-Aguda , Doenças do Sistema Nervoso/diagnóstico , Inflamação , Biomarcadores
6.
Minerva Anestesiol ; 86(10): 1047-1056, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32538580

RESUMO

BACKGROUND: Although esophageal pressure measurement could help clinicians to improve the ventilatory management of acute respiratory distress syndrome (ARDS) patients, it has been mainly used in clinical research. Aim of this study was to compare the measurements of end-expiratory esophageal pressure, end-expiratory transpulmonary pressure and lung stress by three systems: a dedicated manual device, taken as gold standard, a new automatic system (Optivent) and a bedside equipment, consisting of a mechanical ventilator and a hemodynamic monitor. METHODS: In sedated and paralyzed mechanically ventilated ARDS patients the esophageal pressure was measured at three PEEP levels in random fashion (baseline level, 50% higher and 50% lower). RESULTS: Forty patients were enrolled (BMI 25 [23-28] kg/m2, PaO2/FiO2 187 [137-223] and PEEP 9±3 cmH2O). The mean esophageal pressure measured during an expiratory pause by the dedicated system, the bedside system and Optivent were 10.0±4.2, 10±4 and 9.9±4.0 cmH2O, respectively. The respective bias and limits of agreement between the dedicated system and Optivent and between the dedicated system and the bedside system were as follows: end-expiratory esophageal pressure, 0.2 cmH2O, (-0.4 to 0.9) and -0.1 cmH2O (-1.9 to 1.7); end-expiratory transpulmonary pressure, -0.6 cmH2O (-1.7 to 0.4) and -0.4 cmH2O, (-2.2 to 1.5); lung stress -0.9 cmH2O (-3.0 to 1.1) and -1.5 cmH2O (-4.4 to 1.4). CONCLUSIONS: Both Optivent and the bedside system showed clinically acceptability if compared to the gold standard device. The possibility to apply one of these systems could allow a wider use of esophageal pressure in clinical practice.


Assuntos
Respiração com Pressão Positiva , Síndrome do Desconforto Respiratório , Humanos , Pulmão , Síndrome do Desconforto Respiratório/terapia
7.
J Clin Med ; 8(8)2019 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-31370195

RESUMO

Hypoxemia during one-lung ventilation is a challenge in the clinical practice. Moving from the results of the study conducted by Choi et al., we discuss the possibility to modulate hypoxemia by administering iloprost via inhalation, in the light of the physiological mechanisms.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA