Resultados 1 - 20 de 24
Filtrar
1.
Neuroimage ; 255: 119175, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35390460

RESUMO

OBJECTIVE: Gamma synchrony is a fundamental functional property of the cerebral cortex, impaired in multiple neuropsychiatric conditions (i.e. schizophrenia, Alzheimer's disease, stroke etc.). Auditory stimulation in the gamma range allows to drive gamma synchrony of the entire cortical mantle and to estimate the efficiency of the mechanisms sustaining it. As gamma synchrony depends strongly on the interplay between parvalbumin-positive interneurons and pyramidal neurons, we hypothesize an association between cortical thickness and gamma synchrony. To test this hypothesis, we employed a combined magnetoencephalography (MEG) - Magnetic Resonance Imaging (MRI) study. METHODS: Cortical thickness was estimated from anatomical MRI scans. MEG measurements related to exposure of 40 Hz amplitude modulated tones were projected onto the cortical surface. Two measures of cortical synchrony were considered: (a) inter-trial phase consistency at 40 Hz, providing a vertex-wise estimation of gamma synchronization, and (b) phase-locking values between primary auditory cortices and whole cortical mantle, providing a measure of long-range cortical synchrony. A correlation between cortical thickness and synchronization measures was then calculated for 72 MRI-MEG scans. RESULTS: Both inter-trial phase consistency and phase locking values showed a significant positive correlation with cortical thickness. For inter-trial phase consistency, clusters of strong associations were found in the temporal and frontal lobes, especially in the bilateral auditory and pre-motor cortices. Higher phase-locking values corresponded to higher cortical thickness in the frontal, temporal, occipital and parietal lobes. DISCUSSION AND CONCLUSIONS: In healthy subjects, a thicker cortex corresponds to higher gamma synchrony and connectivity in the primary auditory cortex and beyond, likely reflecting underlying cell density involved in gamma circuitries. This result hints towards an involvement of gamma synchrony together with underlying brain structure in brain areas for higher order cognitive functions. This study contributes to the understanding of inherent cortical functional and structural brain properties, which might in turn constitute the basis for the definition of useful biomarkers in patients showing aberrant gamma synchronization.


Assuntos
Córtex Auditivo , Esquizofrenia , Estimulação Acústica/métodos , Córtex Auditivo/fisiologia , Córtex Cerebral/diagnóstico por imagem , Potenciais Evocados Auditivos/fisiologia , Humanos , Imageamento por Ressonância Magnética/métodos , Magnetoencefalografia/métodos
2.
Magn Reson Med ; 88(4): 1561-1574, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35775790

RESUMO

PURPOSE: Myocardial fat infiltrations are associated with a range of cardiomyopathies. The purpose of this study was to perform cardio-respiratory motion-correction for model-based water-fat separation to image fatty infiltrations of the heart in a free-breathing, non-cardiac-triggered high-resolution 3D MRI acquisition. METHODS: Data were acquired in nine patients using a free-breathing, non-cardiac-triggered high-resolution 3D Dixon gradient-echo sequence and radial phase encoding trajectory. Motion correction was combined with a model-based water-fat reconstruction approach. Respiratory and cardiac motion models were estimated using a dual-mode registration algorithm incorporating both motion-resolved water and fat information. Qualitative comparisons of fat structures were made between 2D clinical routine reference scans and reformatted 3D motion-corrected images. To evaluate the effect of motion correction the local sharpness of epicardial fat structures was analyzed for motion-averaged and motion-corrected fat images. RESULTS: The reformatted 3D motion-corrected reconstructions yielded qualitatively comparable fat structures and fat structure sharpness in the heart as the standard 2D breath-hold. Respiratory motion correction improved the local sharpness on average by 32% ± 24% with maximum improvements of 81% and cardiac motion correction increased the sharpness further by another 15% ± 11% with maximum increases of 31%. One patient showed a fat infiltration in the myocardium and cardio-respiratory motion correction was able to improve its visualization in 3D. CONCLUSION: The 3D water-fat separated cardiac images were acquired during free-breathing and in a clinically feasible and predictable scan time. Compared to a motion-averaged reconstruction an increase in sharpness of fat structures by 51% ± 27% using the presented motion correction approach was observed for nine patients.


Assuntos
Coração , Água , Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Movimento (Física)
3.
Magn Reson Med ; 88(2): 663-675, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35344593

RESUMO

PURPOSE: To implement and evaluate a simultaneous multi-slice balanced SSFP (SMS-bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 × 1.4 mm2 ) at 1.5T. METHODS: A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF-CAIPI with gradient-controlled local Larmor adjustment (GC-LOLA) in the presence of fat. A nine-slice SMS-bSSFP sequence using RF-CAIPI with GC-LOLA with high spatial resolution (1.4 × 1.4 mm2 ) and a conventional three-slice sequence with conventional spatial resolution (1.9 × 1.9 mm2 ) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal-to-noise ratio (SNR) on a 4-point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed. RESULTS: Fat signal leakage was significantly higher for blipped CAIPI than for RF-CAIPI with GC-LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS-bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 ± 0.6 vs. 2.7 ± 0.2, p = 0.8) or perceived SNR (2.8 ± 0.3 vs. 2.7 ± 0.3, p = 0.3). Inter-reader variability was good for both image quality (ICC = 0.84) and perceived SNR (ICC = 0.70). Myocardial sharpness was improved using the SMS sequence compared to the conventional sequence (0.37 ± 0.08 vs 0.32 ± 0.05, p < 0.001). There was no significant difference between measurements of upslope index for the SMS and conventional sequences (0.11 ± 0.04 vs. 0.11 ± 0.03, p = 0.84). CONCLUSION: SMS-bSSFP with multiband factor 3 and compressed sensing reconstruction enables cardiac MR perfusion imaging with three-fold increased spatial coverage and improved myocardial sharpness compared to a conventional sequence, without compromising perceived SNR, image quality, upslope index or number of diagnostic segments.


Assuntos
Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Ventrículos do Coração/diagnóstico por imagem , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Perfusão , Reprodutibilidade dos Testes
4.
Neurol Sci ; 43(9): 5313-5322, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35739332

RESUMO

People with Parkinson's disease (PD) experience functional limitations early in the progression of the disease, showing, among other cognitive deficits, difficulties in mathematical abilities. The neural correlates of such abilities have been scarcely investigated in PD, and it is not known whether patients may exhibit difficulties only in formal numerical tasks (e.g., mental multiplications), or also in everyday activities involving numbers (i.e., informal numerical abilities such as time estimates). The present study investigated formal and informal numerical abilities in PD patients and explored their relationship with cortical and subcortical brain volume. We examined patients with PD and mild cognitive impairment (PD-MCI) and age-matched healthy controls (HCs) using the numerical activities of daily living (NADL) battery, assessing both scholastic numerical abilities (formal test), and the ability to use numbers in everyday life (informal test). We compared NADL performances in both groups. Within the PD group, we investigated the association between NADL and cortical and subcortical volumes using multiple linear regressions. The correlation with other cognitive tests was also explored. PD-MCI performed worse than HC in the formal NADL test. In PD-MCI patients, brain-behavior correlations showed two distinct patterns: cortical volumes correlated positively, while striatal volumes correlated negatively with NADL formal tasks. Both formal and informal tests correlated with measures of cognitive functioning. Our results suggest specific impairments in formal numerical abilities in PD-MCI, but not in everyday activities. While cortical atrophy is associated with worse performance, the negative correlations with subcortical regions suggest that their activation may reflect potential compensatory mechanisms.


Assuntos
Disfunção Cognitiva , Doença de Parkinson , Atividades Cotidianas/psicologia , Disfunção Cognitiva/fisiopatologia , Humanos , Conceitos Matemáticos , Testes Neuropsicológicos , Doença de Parkinson/psicologia
5.
Magn Reson Med ; 86(2): 663-676, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33749026

RESUMO

PURPOSE: To enable all-systolic first-pass rest myocardial perfusion with long saturation times. To investigate the change in perfusion contrast and dark rim artefacts through simulations and surrogate measurements. METHODS: Simulations were employed to investigate optimal saturation time for myocardium-perfusion defect contrast and blood-to-myocardium signal ratios. Two saturation recovery blocks with long/short saturation times (LTS/STS) were employed to image 3 slices at end-systole and diastole. Simultaneous multi-slice balanced steady state free precession imaging and compressed sensing acceleration were combined. The sequence was compared to a 3 slice-by-slice clinical protocol in 10 patients. Quantitative assessment of myocardium-peak pre contrast and blood-to-myocardium signal ratios, as well as qualitative assessment of perceived SNR, image quality, blurring, and dark rim artefacts, were performed. RESULTS: Simulations showed that with a bolus of 0.075 mmol/kg, a LTS of 240-470 ms led to a relative increase in myocardium-perfusion defect contrast of 34% ± 9%-28% ± 27% than a STS = 120 ms, while reducing blood-to-myocardium signal ratio by 18% ± 10%-32% ± 14% at peak myocardium. With a bolus of 0.05 mmol/kg, LTS was 320-570 ms with an increase in myocardium-perfusion defect contrast of 63% ± 13%-62% ± 29%. Across patients, LTS led to an average increase in myocardium-peak pre contrast of 59% (P < .001) at peak myocardium and a lower blood-to-myocardium signal ratio of 47% (P < .001) and 15% (P < .001) at peak blood/myocardium. LTS had improved motion robustness (P = .002), image quality (P < .001), and decreased dark rim artefacts (P = .008) than the clinical protocol. CONCLUSION: All-systolic rest perfusion can be achieved by combining simultaneous multi-slice and compressed sensing acceleration, enabling 3-slice cardiac coverage with reduced motion and dark rim artefacts. Numerical simulations indicate that myocardium-perfusion defect contrast increases at LTS.


Assuntos
Imageamento por Ressonância Magnética , Imagem de Perfusão do Miocárdio , Aceleração , Meios de Contraste , Coração/diagnóstico por imagem , Humanos , Perfusão , Sístole
6.
Magn Reson Med ; 84(1): 327-338, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31873954

RESUMO

PURPOSE: Two-dimensional selective excitation (2DRF) allows shortening 4D flow scan times by reducing the FOV, but the longer 2DRF pulse duration decreases the temporal resolution, yielding underestimated peak flow values. Multiple k-space lines per cardiac phase, nl ≥ 2, are commonly applied in 4D flow MRI to shorten the inherent long scan times. We demonstrate that 2DRF 4D flow with nl ≥ 2 can be easily combined with UNFOLD (UNaliasing by Fourier-encoding the Overlaps using the temporaL Dimension), a technique that allows regaining nominally the temporal resolution of the respective acquisition with nl = 1, to assure peak flow quantification. METHODS: Two different 2DRF pulses with spiral k-space trajectories were designed and integrated into a 4D flow sequence. Flow phantom experiments and 7 healthy control 4D flow in vivo measurements, with and without UNFOLD reconstructions, were compared with conventional reconstruction and 1D slab-selective excitation (1DRF) by evaluating time-resolved flow curves, peak flow, peak velocity, blood flow volume per cardiac cycle, and spatial aliasing. RESULTS: Applying UNFOLD to 4D flow imaging with 2DRF and reduced FOV increased the quantified in vivo peak flow values significantly by 3.7% ± 2.3% to 5.2% ± 2.4% (P < .05). Accordingly, the peak flow underestimation of 2DRF scans compared with conventional 1DRF scans decreased with UNFOLD. Finally, 2DRF combined with UNFOLD accelerated the 4D flow acquisition 3.5 ± 1.4 fold by reducing the FOV and increasing the effective temporal resolution by 6.7% compared with conventional 1D selective excitation, with 2 k-space lines per cardiac phase. CONCLUSION: Two-dimensional selective excitation combined with UNFOLD allows limiting the FOV to shorten 4D flow scan times and compensates for the loss in temporal resolution with 2DRF (Δt = 64.8 ms) compared with 1DRF (Δt = 43.2 ms), yielding an effective resolution of Δteff = 40.5 ms to enhance peak flow quantification.


Assuntos
Coração , Imageamento por Ressonância Magnética , Velocidade do Fluxo Sanguíneo , Coração/diagnóstico por imagem , Hemodinâmica , Imageamento Tridimensional , Imagens de Fantasmas
7.
Magn Reson Med ; 84(5): 2429-2441, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32306471

RESUMO

PURPOSE: To develop an autocalibrated multiband (MB) CAIPIRINHA acquisition scheme with in-plane k-t acceleration enabling multislice three-directional tissue phase mapping in one breath-hold. METHODS: A k-t undersampling scheme was integrated into a time-resolved electrocardiographic-triggered autocalibrated MB gradient-echo sequence. The sequence was used to acquire data on 4 healthy volunteers with MB factors of two (MB2) and three (MB3), which were reconstructed using a joint reconstruction algorithm that tackles both k-t and MB acceleration. Forward simulations of the imaging process were used to tune the reconstruction model hyperparameters. Direct comparisons between MB and single-band tissue phase-mapping measurements were performed. RESULTS: Simulations showed that the velocities could be accurately reproduced with MB2 k-t (average ± twice the SD of the RMS error of 0.08 ± 0.22 cm/s and velocity peak reduction of 1.03% ± 6.47% compared with fully sampled velocities), whereas acceptable results were obtained with MB3 k-t (RMS error of 0.13 ± 0.58 cm/s and peak reduction of 2.21% ± 13.45%). When applied to tissue phase-mapping data, the proposed technique allowed three-directional velocity encoding to be simultaneously acquired at two/three slices in a single breath-hold of 18 heartbeats. No statistically significant differences were detected between MB2/MB3 k-t and single-band k-t motion traces averaged over the myocardium. Regional differences were found, however, when using the American Heart Association model for segmentation. CONCLUSION: An autocalibrated MB k-t acquisition/reconstruction framework is presented that allows three-directional velocity encoding of the myocardial velocities at multiple slices in one breath-hold.


Assuntos
Coração , Interpretação de Imagem Assistida por Computador , Aceleração , Algoritmos , Suspensão da Respiração , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes
8.
Magn Reson Med ; 84(2)2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31898832

RESUMO

PURPOSE: To enable rigid body motion-tolerant parallel volumetric magnetic resonance imaging by retrospective head motion correction on a variety of spatiotemporal scales and imaging sequences. THEORY AND METHODS: Tolerance against rigid body motion is based on distributed and incoherent sampling orders for boosting a joint retrospective motion estimation and reconstruction framework. Motion resilience stems from the encoding redundancy in the data, as generally provided by the coil array. Hence, it does not require external sensors, navigators or training data, so the methodology is readily applicable to sequences using 3D encodings. RESULTS: Simulations are performed showing full inter-shot corrections for usual levels of in vivo motion, large number of shots, standard levels of noise and moderate acceleration factors. Feasibility of inter- and intra-shot corrections is shown under controlled motion in vivo. Practical efficacy is illustrated by high-quality results in most corrupted of 208 volumes from a series of 26 clinical pediatric examinations collected using standard protocols. CONCLUSIONS: The proposed framework addresses the rigid motion problem in volumetric anatomical brain scans with sufficient encoding redundancy which has enabled reliable pediatric examinations without sedation.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Artefatos , Encéfalo/diagnóstico por imagem , Criança , Humanos , Imageamento por Ressonância Magnética , Movimento (Física) , Estudos Retrospectivos
9.
Magn Reson Med ; 84(6): 3103-3116, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32530064

RESUMO

PURPOSE: To implement and evaluate a pseudorandom undersampling scheme for combined simultaneous multislice (SMS) balanced SSFP (bSSFP) and compressed-sensing (CS) reconstruction to enable myocardial perfusion imaging with high spatial resolution and coverage at 1.5 T. METHODS: A prospective pseudorandom undersampling scheme that is compatible with SMS-bSSFP phase-cycling requirements and CS was developed. The SMS-bSSFP CS with pseudorandom and linear undersampling schemes were compared in a phantom. A high-resolution (1.4 × 1.4 mm2 ) six-slice SMS-bSSFP CS perfusion sequence was compared with a conventional (1.9 × 1.9 mm2 ) three-slice sequence in 10 patients. Qualitative assessment of image quality, perceived SNR, and number of diagnostic segments and quantitative measurements of sharpness, upslope index, and contrast ratio were performed. RESULTS: In phantom experiments, pseudorandom undersampling resulted in residual artifact (RMS error) reduction by a factor of 7 compared with linear undersampling. In vivo, the proposed sequence demonstrated higher perceived SNR (2.9 ± 0.3 vs. 2.2 ± 0.6, P = .04), improved sharpness (0.35 ± 0.03 vs. 0.32 ± 0.05, P = .01), and a higher number of diagnostic segments (100% vs. 94%, P = .03) compared with the conventional sequence. There were no significant differences between the sequences in terms of image quality (2.5 ± 0.4 vs. 2.8 ± 0.2, P = .08), upslope index (0.11 ± 0.02 vs. 0.10 ± 0.01, P = .3), or contrast ratio (3.28 ± 0.35 vs. 3.36 ± 0.43, P = .7). CONCLUSION: A pseudorandom k-space undersampling compatible with SMS-bSSFP and CS reconstruction has been developed and enables cardiac MR perfusion imaging with increased spatial resolution and myocardial coverage, increased number of diagnostic segments and perceived SNR, and no difference in image quality, upslope index, and contrast ratio.


Assuntos
Imageamento por Ressonância Magnética , Imagem de Perfusão do Miocárdio , Artefatos , Humanos , Processamento de Imagem Assistida por Computador , Perfusão , Estudos Prospectivos
10.
Magn Reson Med ; 82(3): 886-900, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31002417

RESUMO

PURPOSE: 4D flow MRI permits to quantify non-invasively time-dependent velocity vector fields, but it demands long acquisition times. 2D-selective excitation allows to accelerate the acquisition by reducing the FOV in both phase encoding directions. In this study, we investigate 2D-selective excitation with reduced FOV imaging for fast 4D flow imaging while obtaining correct velocity quantification. METHODS: Two different 2D-selective excitation pulses were designed using spiral k-space trajectories. Further, their isophase time point was analyzed using simulations that considered both stationary and moving spins. On this basis, the 2D-selective RF pulses were implemented into a 4D flow sequence. A flow phantom study and seven 4D flow in vivo measurements were performed to assess the accuracy of velocity quantification by comparing the proposed technique to non-selective and conventional 1D slab-selective excitation. RESULTS: The isophase time point for spiral 2D-selective RF pulses was found to be located at the end of excitation for both stationary and moving spins. Based on that, 2D-selective excitation with reduced FOV allowed us to successfully quantify velocities both in a flow phantom and in vivo. In a flow phantom, the velocity difference Δv¯=0.8±5.3cm/s between the smaller reduced FOV and the reference scan was similar to the inter-scan variability of Δv¯=-1.0±2.3cm/s . In vivo, the differences in flow (P = 0.995) and flow volume (P = 0.469) between the larger reduced FOV and the reference scan were non-significant. By reducing the FOV by two-thirds, acquisition time was halved. CONCLUSION: A reduced field-of-excitation allows to limit the FOV and therefore shorten 4D flow acquisition times while preserving successful velocity quantification.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Adulto Jovem
11.
Magn Reson Med ; 81(2): 1016-1030, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30295955

RESUMO

PURPOSE: In conventional multiband (MB) CAIPIRINHA, additional reference scans are acquired to allow the separation of the excited slices. In this study, an acquisition-reconstruction technique that makes use of the MB data to calculate these reference data is presented. The method was integrated into a 2D time-resolved phase-contrast MR sequence used to assess velocities of the myocardium. METHODS: The RF phases of the MB pulse are cycled through time so that consecutive cardiac phases can be grouped to form reference scans at a lower temporal resolution. These reference data are subsequently used to separate the original slices at the original, high temporal resolution using slice/split-slice GRAPPA algorithms. Slice separation performances are evaluated and compared with conventional methods at 3 T, and 3 different strategies for the calibration of the kernels are proposed and compared. Finally, 6 subjects were scanned to assess velocities of the myocardium. RESULTS: Because the acquisition of external references is not needed, no additional breath-holds are required and the full MB acceleration could be exploited. Because the reference and MB data have the same resolution and phase structure, better slice separation was achieved when comparing the proposed technique to conventional workflows. Finally, time-resolved velocities of the myocardial tissue were successfully quantified from MB data, showing good agreement with single-band measurements. CONCLUSION: Our built-in reference method allows the full exploitation of the MB acceleration and it limits the number of breath-holds.


Assuntos
Imagem Ecoplanar , Coração/diagnóstico por imagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Algoritmos , Artefatos , Mapeamento Encefálico , Suspensão da Respiração , Humanos , Microscopia de Contraste de Fase , Miocárdio/patologia , Imagens de Fantasmas
12.
Magn Reson Med ; 81(1): 477-485, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30058204

RESUMO

PURPOSE: Echo planar imaging (EPI) is the primary sequence for functional and diffusion MRI. In fetal applications, the large field of view needed to encode the maternal abdomen leads to prolonged EPI readouts, which may be further extended due to safety considerations that limit gradient performance. The resulting images become very sensitive to water-fat shift and susceptibility artefacts. The purpose of this study was to reduce artefacts and increase stability of EPI in fetal brain imaging, balancing local field homogeneity across the fetal brain with longer range variations to ensure compatibility with fat suppression of the maternal abdomen. METHODS: Spectral Pre-saturation with Inversion-Recovery (SPIR) fat suppression was optimized by investigating SPIR pulse frequency offsets. Subsequently, fetal brain EPI data were acquired using image-based (IB) shimming on 6 pregnant women by (1) minimizing B0 field variations within the fetal brain (localized IB shimming) and (2) with added constraint to limit B0 variation in maternal fat (fat constrained IB shimming). RESULTS: The optimal offset for the SPIR pulse at 3 Tesla was 550 Hz. Both shimming approaches had similar performances in terms of B0 homogeneity within the brain, but constrained IB shimming enabled higher fat suppression efficiency. CONCLUSION: Optimized SPIR in combination with constrained IB shimming can improve maternal fat suppression while minimizing EPI distortions in the fetal brain.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Feto/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Diagnóstico Pré-Natal/métodos , Abdome/diagnóstico por imagem , Algoritmos , Artefatos , Encéfalo/diagnóstico por imagem , Encéfalo/embriologia , Feminino , Humanos , Aumento da Imagem/métodos , Segurança do Paciente , Gravidez
13.
Magn Reson Med ; 80(1): 279-285, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29115686

RESUMO

PURPOSE: Fetal functional MRI studies using conventional 2-dimensional single-shot echo-planar imaging sequences may require discarding a large data fraction as a result of fetal and maternal motion. Increasing the temporal resolution using echo volumar imaging (EVI) could provide an effective alternative strategy. Echo volumar imaging was combined with inner volume (IV) imaging (IVEVI) to locally excite the fetal brain and acquire full 3-dimensional images, fast enough to freeze most fetal head motion. METHODS: IVEVI was implemented by modifying a standard multi-echo echo-planar imaging sequence. A spin echo with orthogonal excitation and refocusing ensured localized excitation. To introduce T2* weighting and to save time, the k-space center was shifted relative to the spin echo. Both single and multi-shot variants were tested. Acoustic noise was controlled by adjusting the amplitude and switching frequency of the readout gradient. Image-based shimming was used to minimize B0 inhomogeneities within the fetal brain. RESULTS: The sequence was first validated in an adult. Eight fetuses were scanned using single-shot IVEVI at a 3.5 × 3.5 × 5.0 mm3 resolution with a readout duration of 383 ms. Multishot IVEVI showed reduced geometric distortions along the second phase-encode direction. CONCLUSIONS: Fetal EVI remains challenging. Although effective echo times comparable to the T2* values of fetal cortical gray matter at 3 T could be achieved, controlling acoustic noise required longer readouts, leading to substantial distortions in single-shot images. Although multishot variants enabled us to reduce susceptibility-induced geometric distortions, sensitivity to motion was increased. Future studies should therefore focus on improvements to multishot variants. Magn Reson Med 80:279-285, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/embriologia , Imagem Ecoplanar , Imageamento por Ressonância Magnética , Diagnóstico Pré-Natal/métodos , Adulto , Algoritmos , Feminino , Cabeça/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Masculino , Movimento (Física) , Neuroimagem , Gravidez , Reprodutibilidade dos Testes , Adulto Jovem
14.
Magn Reson Med ; 79(3): 1447-1459, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28653363

RESUMO

PURPOSE: To develop a purpose-built quiet echo planar imaging capability for fetal functional and diffusion scans, for which acoustic considerations often compromise efficiency and resolution as well as angular/temporal coverage. METHODS: The gradient waveforms in multiband-accelerated single-shot echo planar imaging sequences have been redesigned to minimize spectral content. This includes a sinusoidal read-out with a single fundamental frequency, a constant phase encoding gradient, overlapping smoothed CAIPIRINHA blips, and a novel strategy to merge the crushers in diffusion MRI. These changes are then tuned in conjunction with the gradient system frequency response function. RESULTS: Maintained image quality, SNR, and quantitative diffusion values while reducing acoustic noise up to 12 dB (A) is illustrated in two adult experiments. Fetal experiments in 10 subjects covering a range of parameters depict the adaptability and increased efficiency of quiet echo planar imaging. CONCLUSION: Purpose-built for highly efficient multiband fetal echo planar imaging studies, the presented framework reduces acoustic noise for all echo planar imaging-based sequences. Full optimization by tuning to the gradient frequency response functions allows for a maximally time-efficient scan within safe limits. This allows ambitious in-utero studies such as functional brain imaging with high spatial/temporal resolution and diffusion scans with high angular/spatial resolution to be run in a highly efficient manner at acceptable sound levels. Magn Reson Med 79:1447-1459, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Adulto , Encéfalo/diagnóstico por imagem , Feminino , Feto/diagnóstico por imagem , Humanos , Masculino , Neuroimagem/métodos , Imagens de Fantasmas , Gravidez , Diagnóstico Pré-Natal
15.
Magn Reson Med ; 80(1): 137-146, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29193244

RESUMO

PURPOSE: Ultrafast single-shot T2 -weighted images are common practice in fetal MR exams. However, there is limited experience with fetal T1 -weighted acquisitions. This study aims at establishing a robust framework that allows fetal T1 -weighted scans to be routinely acquired in utero at 3T. METHODS: A 2D gradient echo sequence with an adiabatic inversion was optimized to be robust to fetal motion and maternal breathing optimizing grey/white matter contrast at the same time. This was combined with slice to volume registration and super resolution methods to produce volumetric reconstructions. The sequence was tested on 22 fetuses. RESULTS: Optimized grey/white matter contrast and robustness to fetal motion and maternal breathing were achieved. Signal from cerebrospinal fluid (CSF) and amniotic fluid was nulled and 0.75 mm isotropic anatomical reconstructions of the fetal brain were obtained using slice-to-volume registration and super resolution techniques. Total acquisition time for a single stack was 56 s, all acquired during free breathing. Enhanced sensitivity to normal anatomy and pathology with respect to established methods is demonstrated. A direct comparison with a 3D spoiled gradient echo sequence and a controlled motion experiment run on an adult volunteer are also shown. CONCLUSION: This paper describes a robust framework to perform T1 -weighted acquisitions and reconstructions of the fetal brain in utero. Magn Reson Med 80:137-146, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/embriologia , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Diagnóstico Pré-Natal/métodos , Adulto , Algoritmos , Artefatos , Meios de Contraste , Feminino , Substância Cinzenta/diagnóstico por imagem , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Movimento (Física) , Gravidez , Diagnóstico Pré-Natal/instrumentação , Reprodutibilidade dos Testes , Respiração , Razão Sinal-Ruído , Substância Branca/diagnóstico por imagem
16.
Neuroimage ; 127: 298-306, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26708014

RESUMO

Optimal contrast to noise ratio of the BOLD signal in neonatal and foetal fMRI has been hard to achieve because of the much longer T2(⁎) values in developing brain tissue in comparison to those in the mature adult brain. The conventional approach of optimizing fMRI sequences would suggest matching the echo time (TE) and the T2(⁎) of the neonatal and foetal brain. However, the use of a long echo time would typically increase the minimum repetition time (TR) resulting in inefficient sampling. Here we apply the concept of echo shifting to task based neonatal fMRI in order to achieve an improved contrast to noise ratio and efficient data sampling at the same time. Echo shifted EPI (es-EPI) is a modification of a standard 2D-EPI sequence which enables echo times longer than the time between consecutive excitations (TE>TS=TRNS, where NS is the number of acquired slices and TS the inter-slice repetition time). The proposed method was tested on neonatal subjects using a passive sensori-motor task paradigm. Dual echo EPI datasets with an identical readout structure to es-EPI were also acquired and used as control data to assess BOLD activation. From the results of the latter analysis, an average increase of 78±41% in contrast to noise ratio was observable when comparing late to short echoes. Furthermore, es-EPI allowed the acquisition of data with an identical contrast to the late echo, but more efficiently since a higher number of slices could be acquired in the same amount of time.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiologia , Imagem Ecoplanar/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Recém-Nascido
17.
Neuroimage ; 101: 555-68, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-25008959

RESUMO

There is growing interest in exploring fetal functional brain development, particularly with Resting State fMRI. However, during a typical fMRI acquisition, the womb moves due to maternal respiration and the fetus may perform large-scale and unpredictable movements. Conventional fMRI processing pipelines, which assume that brain movements are infrequent or at least small, are not suitable. Previous published studies have tackled this problem by adopting conventional methods and discarding as much as 40% or more of the acquired data. In this work, we developed and tested a processing framework for fetal Resting State fMRI, capable of correcting gross motion. The method comprises bias field and spin history corrections in the scanner frame of reference, combined with slice to volume registration and scattered data interpolation to place all data into a consistent anatomical space. The aim is to recover an ordered set of samples suitable for further analysis using standard tools such as Group Independent Component Analysis (Group ICA). We have tested the approach using simulations and in vivo data acquired at 1.5 T. After full motion correction, Group ICA performed on a population of 8 fetuses extracted 20 networks, 6 of which were identified as matching those previously observed in preterm babies.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/embriologia , Feto/fisiologia , Imageamento por Ressonância Magnética/métodos , Rede Nervosa/fisiologia , Mapeamento Encefálico/normas , Feminino , Idade Gestacional , Humanos , Imageamento por Ressonância Magnética/normas , Movimento (Física) , Gravidez , Terceiro Trimestre da Gravidez , Diagnóstico Pré-Natal
18.
Front Aging Neurosci ; 15: 1168576, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37293663

RESUMO

Objectives: In healthy aging, the way people cope differently with cognitive and neural decline is influenced by exposure to cognitively enriching life-experiences. Education is one of them, so that in general, the higher the education, the better the expected cognitive performance in aging. At the neural level, it is not clear yet how education can differentiate resting state functional connectivity profiles and their cognitive underpinnings. Thus, with this study, we aimed to investigate whether the variable education allowed for a finer description of age-related differences in cognition and resting state FC. Methods: We analyzed in 197 healthy individuals (137 young adults aged 20-35 and 60 older adults aged 55-80 from the publicly available LEMON database), a pool of cognitive and neural variables, derived from magnetic resonance imaging, in relation to education. Firstly, we assessed age-related differences, by comparing young and older adults. Then, we investigated the possible role of education in outlining such differences, by splitting the group of older adults based on their education. Results: In terms of cognitive performance, older adults with higher education and young adults were comparable in language and executive functions. Interestingly, they had a wider vocabulary compared to young adults and older adults with lower education. Concerning functional connectivity, the results showed significant age- and education-related differences within three networks: the Visual-Medial, the Dorsal Attentional, and the Default Mode network (DMN). For the DMN, we also found a relationship with memory performance, which strengthen the evidence that this network has a specific role in linking cognitive maintenance and FC at rest in healthy aging. Discussion: Our study revealed that education contributes to differentiating cognitive and neural profiles in healthy older adults. Also, the DMN could be a key network in this context, as it may reflect some compensatory mechanisms relative to memory capacities in older adults with higher education.

19.
iScience ; 26(8): 107387, 2023 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-37575186

RESUMO

Cortical excitability is commonly measured by applying magnetic stimulation in combination with measuring behavioral response. This measure has, however, some shortcomings including spatial limitation to the primary motor cortex and not accounting for intrinsic excitability fluctuations. Here, we use a measure for intrinsic excitability based on phase synchronization previously validated for epilepsy. We apply this measure in 30 healthy participants' magnetoencephalography (MEG) recordings during the exposure of auditory white noise, a stimulus that has been suggested to modify cortical excitability. Using cortical parcellation of the MEG source data, we could find a specific pattern of increased and decreased excitability while participants are exposed to white noise vs. silence. Specifically, excitability during white noise exposure decreases in the frontal lobe and increases in the temporal lobe. This study thus adds to the understanding of cortical excitability changes due to specific environmental stimuli as well as the spatial extent of these effects.

20.
Cortex ; 166: 322-337, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37478549

RESUMO

It has been suggested that Gerstmann's syndrome is the result of subcortical disconnection rather than emerging from damage of a multifunctional brain region within the parietal lobe. However, patterns of white matter tract disconnection following parietal damage have been barely investigated. This single case study allows characterising Gerstmann's syndrome in terms of disconnected networks. We report the case of a left parietal patient affected by Gerstmann's tetrad: agraphia, acalculia, left/right orientation problems, and finger agnosia. Lesion mapping, atlas-based estimation of probability of disconnection, and DTI-based tractography revealed that the lesion was mainly located in the superior parietal lobule, and it caused disruption of both intraparietal tracts passing through the inferior parietal lobule (e.g., tracts connecting the angular, supramarginal, postcentral gyri, and the superior parietal lobule) and fronto-parietal long tracts (e.g., the superior longitudinal fasciculus). The lesion site appears to be located more superiorly as compared to the cerebral regions shown active by other studies during tasks impaired in the syndrome, and it reached the subcortical area potentially critical in the emergence of the syndrome, as hypothesised in previous studies. Importantly, the reconstruction of tracts connecting regions within the parietal lobe indicates that this critical subcortical area is mainly crossed by white matter tracts connecting the angular gyrus and the superior parietal lobule. Taken together, these findings suggest that this case study might be considered as empirical evidence of Gerstmann's tetrad caused by disconnection of intraparietal white matter tracts.


Assuntos
Agnosia , Síndrome de Gerstmann , Substância Branca , Humanos , Substância Branca/patologia , Lobo Parietal , Encéfalo , Agnosia/complicações
SELEÇÃO DE REFERÊNCIAS