Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Br J Anaesth ; 126(1): 331-339, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32950248

RESUMO

BACKGROUND: The design of a videolaryngoscope blade may affect its efficacy. We classified videolaryngoscope blades as standard and non-standard shapes to compare their efficacy performing tracheal intubation in children enrolled in the Paediatric Difficult Intubation Registry. METHODS: Cases entered in the Registry from March 2017 to January 2020 were analysed. We compared the success rates of initial and eventual tracheal intubation, complications, and technical difficulties between the two groups and by weight stratification. RESULTS: Videolaryngoscopy was used in 1313 patients. Standard and non-standard blades were used in 529 and 740 patients, respectively. Both types were used in 44 patients. In children weighing <5 kg, standard blades had significantly greater success than non-standard blades at initial (51% vs 26%, P=0.002) and eventual (81% vs 58%, P=0.002) attempts at tracheal intubation. In multivariable logistic regression analysis, standard blades had 3-fold greater odds of success at initial tracheal intubations compared with non-standard blades (adjusted odds ratio 3.0, 95% confidence interval): 1.32-6.86, P=0.0009). Standard blades had 2.6-fold greater odds of success at eventual tracheal intubation compared with non-standard blades in children weighing <5 kg (adjusted odds ratio 2.6, 95% confidence interval: 1.08-6.25, P=0.033). There was no significant difference found in children weighing ≥5 kg. CONCLUSIONS: In infants weighing <5 kg, videolaryngoscopy with standard blades was associated with a significantly greater success rate than videolaryngoscopy with non-standard blades. Videolaryngoscopy with a standard blade is a sensible choice for tracheal intubation in children who weigh <5 kg.


Assuntos
Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Laringoscopia/instrumentação , Laringoscopia/métodos , Sistema de Registros , Criança , Pré-Escolar , Desenho de Equipamento , Feminino , Humanos , Laringoscópios , Masculino , Estudos Retrospectivos , Gravação em Vídeo
2.
Lancet Respir Med ; 4(1): 37-48, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26705976

RESUMO

BACKGROUND: Despite the established vulnerability of children during airway management, remarkably little is known about complications in children with difficult tracheal intubation. To address this concern, we developed a multicentre registry (Pediatric Difficult Intubation [PeDI]) to characterise risk factors for difficult tracheal intubation, establish the success rates of various tracheal intubation techniques, catalogue the complications of children with difficult tracheal intubation, and establish the effect of more than two tracheal intubation attempts on complications. METHODS: The PeDI registry consists of prospectively collected tracheal intubation data from 13 children's hospitals in the USA. We established standard data collection methods before implementing the secure web-based registry. After establishing standard definitions, we collected and analysed patient, clinician, and practice data and tracheal intubation outcomes. We categorised complications as severe or non-severe. FINDINGS: Between August, 2012, and January, 2015, 1018 difficult paediatric tracheal intubation encounters were done. The most frequently attempted first tracheal intubation techniques were direct laryngoscopy (n=461, 46%), fibre-optic bronchoscopy (n=284 [28%]), and indirect video laryngoscopy (n=183 [18%]) with first attempt success rates of 16 (3%) of 461 with direct laryngoscopy, 153 (54%) of 284 with fibre-optic bronchoscopy, and 101 (55%) of 183 with indirect video laryngoscopy. Tracheal intubation failed in 19 (2%) of cases. 204 (20%) children had at least one complication; 30 (3%) of these were severe and 192 (19%) were non-severe. The most common severe complication was cardiac arrest, which occurred in 15 (2%) patients. The occurrence of complications was associated with more than two tracheal intubation attempts, a weight of less than 10 kg, short thyromental distance, and three direct laryngoscopy attempts before an indirect technique. Temporary hypoxaemia was the most frequent non-severe complication. INTERPRETATION: More than two direct laryngoscopy attempts in children with difficult tracheal intubation are associated with a high failure rate and an increased incidence of severe complications. These results suggest that limiting the number of direct laryngoscopy attempts and quickly transitioning to an indirect technique when direct laryngoscopy fails would enhance patient safety. FUNDING: None.


Assuntos
Broncoscopia , Parada Cardíaca/epidemiologia , Hipóxia/epidemiologia , Intubação Intratraqueal , Laringoscopia , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Cirurgia Vídeoassistida , Adolescente , Manuseio das Vias Aéreas , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Incidência , Lactente , Masculino , Estudos Prospectivos , Fatores de Risco , Traqueia/lesões , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA