Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 163
Filtrar
1.
J Cardiovasc Magn Reson ; 26(1): 101041, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38527706

RESUMO

Cardiovascular magnetic resonance (CMR) has become the reference standard for quantitative and qualitative assessment of ventricular function, blood flow, and myocardial tissue characterization. There is a preponderance of large CMR studies and registries in adults; However, similarly powered studies are lacking for the pediatric and congenital heart disease (PCHD) population. To date, most CMR studies in children are limited to small single or multicenter studies, thereby limiting the conclusions that can be drawn. Within the PCHD CMR community, a collaborative effort has been successfully employed to recognize knowledge gaps with the aim to embolden the development and initiation of high-quality, large-scale multicenter research. In this publication, we highlight the underlying challenges and provide a practical guide toward the development of larger, multicenter initiatives focusing on PCHD populations, which can serve as a model for future multicenter efforts.


Assuntos
Cardiopatias Congênitas , Estudos Multicêntricos como Assunto , Valor Preditivo dos Testes , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Criança , Big Data , Imageamento por Ressonância Magnética , Projetos de Pesquisa , Fatores Etários , Adolescente , Pré-Escolar
2.
Cardiol Young ; 34(2): 387-394, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37462049

RESUMO

BACKGROUND: Patients with unbalanced common atrioventricular canal can be difficult to manage. Surgical planning often depends on pre-operative echocardiographic measurements. We aimed to determine the added utility of cardiac MRI in predicting successful biventricular repair in common atrioventricular canal. METHODS: We conducted a retrospective cohort study of children with common atrioventricular canal who underwent MRI prior to repair. Associations between MRI and echocardiographic measures and surgical outcome were tested using logistic regression, and models were compared using area under the receiver operator characteristic curve. RESULTS: We included 28 patients (median age at MRI: 5.2 months). The optimal MRI model included the novel end-diastolic volume index (using the ratio of left ventricular end-diastolic volume to total end-diastolic volume) and the left ventricle-right ventricle angle in diastole (area under the curve 0.83, p = 0.041). End-diastolic volume index ≤ 0.18 and left ventricle-right ventricle angle in diastole ≤ 72° yield a sensitivity of 83% and specificity of 81% for successful biventricular repair. The optimal multimodality model included the end-diastolic volume index and the echocardiographic atrioventricular valve index with an area under the curve of 0.87 (p = 0.026). CONCLUSIONS: Cardiac MRI can successfully predict successful biventricular repair in patients with unbalanced common atrioventricular canal utilising the end-diastolic volume index alone or in combination with the MRI left ventricle-right ventricle angle in diastole or the echocardiographic atrioventricular valve index. A prospective cardiac MRI study is warranted to better define the multimodality characteristic predictive of successful biventricular surgery.


Assuntos
Defeitos dos Septos Cardíacos , Criança , Humanos , Lactente , Estudos Retrospectivos , Defeitos dos Septos Cardíacos/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
3.
Pediatr Cardiol ; 44(5): 1108-1117, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37004523

RESUMO

There have been reports of myocarditis following vaccination against COVID-19. We sought to describe cardiac magnetic resonance (CMR) findings among pediatric patients. Retrospective review at a large academic center of patients clinically diagnosed with post-vaccine myocarditis (PVM) undergoing CMR. Data collected included parametric mapping, ventricular function, and degree of late gadolinium enhancement (LGE). Post-processing strain analysis was performed using feature tracking. Strain values, T1/T2 values, and ventricular function were compared to age- and gender-matched controls with viral myocarditis using a Wilcoxon Signed Rank test. Among 12 patients with presumed PVM, 11 were male and 11 presented after the second vaccination dose, typically within 4 days. All presented with chest pain and elevated troponin. 10 met MRI criteria for acute myocarditis. All had LGE typically seen in the lateral and inferior walls; only five had prolonged T1 values. 10 met criteria for edema based on skeletal muscle to myocardium signal intensity ratio and only 5 had prolonged T2 mapping values. Patients with PVM had greater short-axis global circumferential and radial strain, right ventricle function, and cardiac output when compared to those with viral myocarditis. Patients with PVM have greater short-axis global circumferential and radial strains compared to those with viral myocarditis. LGE was universal in our cohort. Signal intensity ratios between skeletal muscle and myocardium may be more sensitive in identifying edema than T2 mapping. Overall, the impact on myocardial strain by CMR is less significant in PVM compared to more classic viral myocarditis.


Assuntos
COVID-19 , Miocardite , Humanos , Masculino , Criança , Feminino , Miocardite/diagnóstico por imagem , Miocardite/etiologia , Vacinas contra COVID-19/efeitos adversos , Meios de Contraste , Valor Preditivo dos Testes , Gadolínio , Imageamento por Ressonância Magnética , Miocárdio/patologia , Espectroscopia de Ressonância Magnética , Estudos Retrospectivos , Vacinação , Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda
4.
J Cardiovasc Magn Reson ; 24(1): 39, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35754040

RESUMO

BACKGROUND: Coronary cardiovascular magnetic resonance angiography (CCMRA) of congenital heart disease (CHD) in pediatric patients requires accurate planning, adequate sequence parameter adjustments, lengthy scanning sessions, and significant involvement from highly trained personnel. Anesthesia and intubation are commonplace to minimize movements and control respiration in younger subjects. To address the above concerns and provide a single-click imaging solution, we applied our free-running framework for fully self-gated (SG) free-breathing 5D whole-heart CCMRA to CHD patients after ferumoxytol injection. We tested the hypothesis that spatial and motion resolution suffice to visualize coronary artery ostia in a cohort of CHD subjects, both for intubated and free-breathing acquisitions. METHODS: In 18 pediatric CHD patients, non-electrocardiogram (ECG) triggered 5D free-running gradient echo CCMRA with whole-heart 1 mm3 isotropic spatial resolution was performed in seven minutes on a 1.5T CMR scanner. Eleven patients were anesthetized and intubated, while seven were breathing freely without anesthesia. All patients were slowly injected with ferumoxytol (4 mg/kg) over 15 minutes. Cardiac and respiratory motion-resolved 5D images were reconstructed with a fully SG approach. To evaluate the performance of motion resolution, visibility of coronary artery origins was assessed. Intubated and free-breathing patient sub-groups were compared for image quality using coronary artery length and conspicuity as well as lung-liver interface sharpness. RESULTS: Data collection using the free-running framework was successful in all patients in less than 8 min; scan planning was very simple without the need for parameter adjustments, while no ECG lead placement and triggering was required. From the resulting SG 5D motion-resolved reconstructed images, coronary artery origins could be retrospectively extracted in 90% of the cases. These general findings applied to both intubated and free-breathing pediatric patients (no difference in terms of lung-liver interface sharpness), while image quality and coronary conspicuity between both cohorts was very similar. CONCLUSIONS: A simple-to-use push-button framework for 5D whole-heart CCMRA was successfully employed in pediatric CHD patients with ferumoxytol injection. This approach, working without any external gating and for a wide range of heart rates and body sizes provided excellent definition of cardiac anatomy for both intubated and free-breathing patients.


Assuntos
Cardiopatias Congênitas , Angiografia por Ressonância Magnética , Criança , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Óxido Ferroso-Férrico , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/patologia , Humanos , Imageamento Tridimensional/métodos , Pulmão , Angiografia por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Respiração , Estudos Retrospectivos
5.
J Cardiovasc Magn Reson ; 24(1): 37, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35725473

RESUMO

Cardiovascular magnetic resonance (CMR) has been utilized in the management and care of pediatric patients for nearly 40 years. It has evolved to become an invaluable tool in the assessment of the littlest of hearts for diagnosis, pre-interventional management and follow-up care. Although mentioned in a number of consensus and guidelines documents, an up-to-date, large, stand-alone guidance work for the use of CMR in pediatric congenital 36 and acquired 35 heart disease endorsed by numerous Societies involved in the care of these children is lacking. This guidelines document outlines the use of CMR in this patient population for a significant number of heart lesions in this age group and although admittedly, is not an exhaustive treatment, it does deal with an expansive list of many common clinical issues encountered in daily practice.


Assuntos
Cardiologia , Cardiopatias , Radiologia , American Heart Association , Criança , Ecocardiografia , Cardiopatias/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , América do Norte , Valor Preditivo dos Testes , Estados Unidos
6.
J Comput Assist Tomogr ; 46(5): 742-746, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35617648

RESUMO

PURPOSE: Children with single-ventricle congenital heart disease undergo a series of operations to maintain their pulmonary circulation including bidirectional Glenn (BDG) or hemi-Fontan in the second stage to create a superior cavopulmonary anastomosis. We aimed to optimize cardiovascular angiography protocols by determining optimal contrast timing of pulmonary and systemic circulation on magnetic resonance angiography (MRA) performed with the technique of time-resolved imaging with interleaved stochastic trajectories (TWIST). METHODS AND MATERIALS: Cardiac TWIST MRA with lower extremity (LE) contrast injection was analyzed in 92 consecutive patients with a BDG or hemi-Fontan anastomosis. Contrast arrival time to inferior vena cava was set to zero to determine the relative time-to-peak (TTP) of the target vessels. Time-to-peak of each vessel was compared by age (<2 or ≥2 y), ejection fraction (<54% or ≥54%), the median values of heart rate (<111 or ≥111 beats per minute), body surface area (BSA, <0.59 or ≥0.59), cardiac index (<6.04 or ≥6.04), and indexed ascending aorta flow (AscAo_i, <5.3 or ≥5.3). The TTP of the vessels was also correlated with the volumetric parameters. RESULTS: The mean age of 92 patients (32 female, 60 male) was 3.1 years (0.7-5.6 years). With LE injection, the first peak was depicted in AscAo. Time-to-peak of the pulmonary arteries was approximately 9 seconds later than AscAo. The TTP difference between pulmonary arteries and AscAo was shorter in high heart rate group (8.3 vs 10 seconds, P < 0.001). The TTP difference between AscAo and the mean of pulmonary arteries was significantly shorter in high cardiac index group (8.4 vs 9.9 seconds, P < 0.01) and high AscAo_i group (8.7 vs 9.7 seconds, P = 0.03). The TTP differences were not significant by age, ejection fraction, and BSA. Cardiac index and AscAo_i were negatively correlated with all TTPs except AscAo. The ejection fraction, stroke volume, and atrioventricular regurgitation fraction did not correlate with the TTP. CONCLUSIONS: In patients with BDG or hemi-Fontan anastomosis, TTP of the pulmonary arteries on TWIST MRA via LE intravenous injection is approximately 9 seconds later than AscAo, approximately 8 and 10 seconds later in high and low heart rate groups, respectively. Cardiac index and AscAo_i have less effect on the TTP than the heart rate. There was no TTP difference of the pulmonary arteries by age, BSA, and ejection fraction and no correlation with ejection fraction, stroke volume, and atrioventricular regurgitation fraction. These data can be used to guide timing of pulmonary arterial enhancement of single-ventricle patients after BDG or hemi-Fontan anastomosis.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Idoso de 80 Anos ou mais , Criança , Feminino , Técnica de Fontan/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Angiografia por Ressonância Magnética , Masculino , Artéria Pulmonar/diagnóstico por imagem , Circulação Pulmonar , Resultado do Tratamento
7.
Pediatr Radiol ; 52(4): 661-675, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34657169

RESUMO

Magnetic resonance imaging (MRI) and CT perform an important role in the evaluation of neonates with congenital heart disease (CHD) when echocardiography is not sufficient for surgical planning or postoperative follow-up. Cardiac MRI and cardiac CT have complementary applications in the evaluation of cardiovascular disease in neonates. This review focuses on the indications and technical aspects of these modalities and special considerations for imaging neonates with CHD.


Assuntos
Cardiopatias Congênitas , Tomografia Computadorizada por Raios X , Coração/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Tomografia Computadorizada por Raios X/métodos
8.
Radiology ; 300(1): 162-173, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33876971

RESUMO

Background The value of MRI in pediatric congenital heart disease (CHD) is well recognized; however, the requirement for expert oversight impedes its widespread use. Four-dimensional (4D) multiphase steady-state imaging with contrast enhancement (MUSIC) is a cardiovascular MRI technique that uses ferumoxytol and captures all anatomic features dynamically. Purpose To evaluate multicenter feasibility of 4D MUSIC MRI in pediatric CHD. Materials and Methods In this prospective study, participants with CHD underwent 4D MUSIC MRI at 3.0 T or 1.5 T between 2014 and 2020. From a pool of 460 total studies, an equal number of MRI studies from three sites (n = 60) was chosen for detailed analysis. With use of a five-point scale, the feasibility of 4D MUSIC was scored on the basis of artifacts, image quality, and diagnostic confidence for intracardiac and vascular connections (n = 780). Respiratory motion suppression was assessed by using the signal intensity profile. Bias between 4D MUSIC and two-dimensional (2D) cine imaging was evaluated by using Bland-Altman analysis; 4D MUSIC examination duration was compared with that of the local standard for CHD. Results A total of 206 participants with CHD underwent MRI at 3.0 T, and 254 participants underwent MRI at 1.5 T. Of the 60 MRI examinations chosen for analysis (20 per site; median participant age, 14.4 months [interquartile range, 2.3-49 months]; 33 female participants), 56 (93%) had good or excellent image quality scores across a spectrum of disease complexity (mean score ± standard deviation: 4.3 ± 0.6 for site 1, 4.9 ± 0.3 for site 2, and 4.6 ± 0.7 for site 3; P < .001). Artifact scores were inversely related to image quality (r = -0.88, P < .001) and respiratory motion suppression (P < .001, r = -0.45). Diagnostic confidence was high or definite in 730 of 780 (94%) intracardiac and vascular connections. The correlation between 4D MUSIC and 2D cine ventricular volumes and ejection fraction was high (range of r = 0.72-0.85; P < .001 for all). Compared with local standard MRI, 4D MUSIC reduced the image acquisition time (44 minutes ± 20 vs 12 minutes ± 3, respectively; P < .001). Conclusion Four-dimensional multiphase steady-state imaging with contrast enhancement MRI in pediatric congenital heart disease was feasible in a multicenter setting, shortened the examination time, and simplified the acquisition protocol, independently of disease complexity. Clinical trial registration no. NCT02752191 © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Roest and Lamb in this issue.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Criança , Pré-Escolar , Meios de Contraste , Estudos de Viabilidade , Feminino , Óxido Ferroso-Férrico , Humanos , Lactente , Masculino , Estudos Prospectivos
9.
Magn Reson Med ; 86(1): 213-229, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33624348

RESUMO

PURPOSE: Whole-heart MRA techniques typically target predetermined motion states, address cardiac and respiratory dynamics independently, and require either complex planning or computationally demanding reconstructions. In contrast, we developed a fast data-driven reconstruction algorithm with minimal physiological assumptions and compatibility with ungated free-running sequences. THEORY AND METHODS: We propose a similarity-driven multi-dimensional binning algorithm (SIMBA) that clusters continuously acquired k-space data to find a motion-consistent subset for whole-heart MRA reconstruction. Free-running 3D radial data sets from 12 non-contrast-enhanced scans of healthy volunteers and six ferumoxytol-enhanced scans of pediatric cardiac patients were reconstructed with non-motion-suppressed regridding of all the acquired data ("All Data"), with SIMBA, and with a previously published free-running framework (FRF) that uses cardiac and respiratory self-gating and compressed sensing. Images were compared for blood-myocardium sharpness and contrast ratio, visibility of coronary artery ostia, and right coronary artery sharpness. RESULTS: Both the 20-second SIMBA reconstruction and FRF provided significantly higher blood-myocardium sharpness than All Data in both patients and volunteers (P < .05). The SIMBA reconstruction provided significantly sharper blood-myocardium interfaces than FRF in volunteers (P < .001) and higher blood-myocardium contrast ratio than All Data and FRF, both in volunteers and patients (P < .05). Significantly more ostia could be visualized with both SIMBA (31 of 36) and FRF (34 of 36) than with All Data (4 of 36) (P < .001). Inferior right coronary artery sharpness using SIMBA versus FRF was observed (volunteers: SIMBA 36.1 ± 8.1%, FRF 40.4 ± 8.9%; patients: SIMBA 35.9 ± 7.7%, FRF 40.3 ± 6.1%, P = not significant). CONCLUSION: The SIMBA technique enabled a fast, data-driven reconstruction of free-running whole-heart MRA with image quality superior to All Data and similar to the more time-consuming FRF reconstruction.


Assuntos
Imageamento Tridimensional , Angiografia por Ressonância Magnética , Algoritmos , Criança , Vasos Coronários/diagnóstico por imagem , Humanos , Movimento (Física)
10.
J Cardiovasc Magn Reson ; 22(1): 19, 2020 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-32160925

RESUMO

With mounting data on its accuracy and prognostic value, cardiovascular magnetic resonance (CMR) is becoming an increasingly important diagnostic tool with growing utility in clinical routine. Given its versatility and wide range of quantitative parameters, however, agreement on specific standards for the interpretation and post-processing of CMR studies is required to ensure consistent quality and reproducibility of CMR reports. This document addresses this need by providing consensus recommendations developed by the Task Force for Post-Processing of the Society for Cardiovascular Magnetic Resonance (SCMR). The aim of the Task Force is to recommend requirements and standards for image interpretation and post-processing enabling qualitative and quantitative evaluation of CMR images. Furthermore, pitfalls of CMR image analysis are discussed where appropriate. It is an update of the original recommendations published 2013.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/normas , Imageamento por Ressonância Magnética/normas , Doenças Cardiovasculares/patologia , Doenças Cardiovasculares/fisiopatologia , Consenso , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
11.
Pediatr Cardiol ; 41(5): 1021-1030, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32377893

RESUMO

Apicocaval juxtaposition (ACJ) is a rare form of viscerocardiac malpositions in association with single-ventricle congenital heart defects. The Fontan surgery is the common palliation, and possible surgical options include ipsilateral, contralateral, and intra-atrial conduits. Concerns include lower hemodynamic performances or risks of conduit compression by the cardiac mass. This study investigates the hemodynamics and clinical outcomes of ACJ patients and potential surgical improvements. Ten consecutive ACJ patients were included, along with a reference cohort of ten non-ACJ patients. Magnetic resonance images were acquired at 6 ± 0.6 year follow-up for anatomical analysis and hemodynamic assessments using computational fluid dynamics. Metrics of interest are deformation index (DI), indexed power loss (iPL), and hepatic flow distribution (HFDoff). A "virtual" surgery was performed to explore potential hemodynamic improvements using a straightened conduit. DI for ACJ patients fell within the DI range of non-ACJ patients. Contralateral conduits had insignificantly higher iPL (0.070 [0.032,0.137]) than ipsilateral conduits (0.041 [0.013,0.095]) and non-ACJ conduits (0.034 [0.011,0.061]). HFDoff was similar for the ipsilateral (21 [12,35]), contralateral (26 [7,41]), and non-ACJ Fontan conduits (17 [0,48]). Virtual surgery demonstrated that a straightened conduit reduced HFDoff and iPL for the contralateral and ipsilateral conduits, potentially leading to improved clinical outcomes. In this limited sample, the hemodynamic performance of ACJ patients was not significantly different from their non-ACJ counterparts. The use of a straightened conduit option could potentially improve patient outcomes. Additionally, the fear of significant compression of conduits for ACJ patients was unsupported.


Assuntos
Técnica de Fontan/métodos , Cardiopatias Congênitas/cirurgia , Adolescente , Estudos de Casos e Controles , Criança , Feminino , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/anormalidades , Ventrículos do Coração/cirurgia , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Masculino , Artéria Pulmonar/patologia , Artéria Pulmonar/cirurgia
12.
Radiology ; 291(3): 774-780, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30938628

RESUMO

Background The Fontan operation is performed for surgical palliation of single ventricle physiology. This operation is usually preceded by a superior cavopulmonary connection (SCPC); lymphatic abnormalities after SCPC may be demonstrated at MRI and prior to the Fontan operation. Purpose To determine if the degree of neck and thoracic lymphatic abnormalities at T2-weighted MRI in patients after superior cavopulmonary connection (SCPC) correlated with surgical outcomes from the Fontan procedure. Materials and Methods Patients for whom SCPC was performed for palliation of single ventricle disease who underwent chest MRI between July 2012 and May 2015 at a single institution were retrospectively reviewed. T2-weighted images were scored as lymphatic type 1 (little or no T2 mediastinal and supraclavicular signal) to type 4 (T2 signal into both the mediastinum and the lung parenchyma). Fontan takedown, duration of post-Fontan hospitalization and pleural effusion, postoperative plastic bronchitis, need for transplant, and mortality were tabulated. The relationship between lymphatic type and clinical outcomes was evaluated by using analysis of variance (ANOVA), the Kruskal-Wallis H test, and the Fisher exact test. Results A total of 83 patients (mean age, 7.9 years ± 2.6) were evaluated. Among these 83 patients, 53 (64%) were classified with type 1 or 2 lymphatic abnormalities, 17 (20%) with type 3, and 12 (16%) with type 4. The rate of failure of Fontan completion was higher in patients with type 4 than in type 1 or 2 (54% vs 2%, respectively; P = .004). Need for cardiac transplant (one of 13 [8%]) and death (three of 13 [23%]) occurred only in type 4. Median postoperative length of stay was longer for patients with type 4 than for those with types 1 or 2 (29 days vs 9 days, respectively; P < .01). Conclusion Greater MRI-based severity of lymphatic abnormalities in patients prior to planned Fontan procedure was associated with failure of Fontan completion and longer postoperative stay. © RSNA, 2019 Online supplemental material is available for this article.


Assuntos
Técnica de Fontan , Anormalidades Linfáticas/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Criança , Pré-Escolar , Técnica de Fontan/efeitos adversos , Técnica de Fontan/mortalidade , Técnica de Fontan/estatística & dados numéricos , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/cirurgia , Humanos , Tempo de Internação , Anormalidades Linfáticas/etiologia , Sistema Linfático/diagnóstico por imagem , Sistema Linfático/patologia , Imageamento por Ressonância Magnética , Pescoço/diagnóstico por imagem , Pescoço/patologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Tórax/diagnóstico por imagem , Tórax/patologia , Resultado do Tratamento
13.
Radiology ; 293(3): 554-564, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31638489

RESUMO

Background Ferumoxytol is approved for use in the treatment of iron deficiency anemia, but it can serve as an alternative to gadolinium-based contrast agents. On the basis of postmarketing surveillance data, the Food and Drug Administration issued a black box warning regarding the risks of rare but serious acute hypersensitivity reactions during fast high-dose injection (510 mg iron in 17 seconds) for therapeutic use. Whereas single-center safety data for diagnostic use have been positive, multicenter data are lacking. Purpose To report multicenter safety data for off-label diagnostic ferumoxytol use. Materials and Methods The multicenter ferumoxytol MRI registry was established as an open-label nonrandomized surveillance databank without industry involvement. Each center monitored all ferumoxytol administrations, classified adverse events (AEs) using the National Cancer Institute Common Terminology Criteria for Adverse Events (grade 1-5), and assessed the relationship of AEs to ferumoxytol administration. AEs related to or possibly related to ferumoxytol injection were considered adverse reactions. The core laboratory adjudicated the AEs and classified them with the American College of Radiology (ACR) classification. Analysis of variance was used to compare vital signs. Results Between January 2003 and October 2018, 3215 patients (median age, 58 years; range, 1 day to 96 years; 1897 male patients) received 4240 ferumoxytol injections for MRI. Ferumoxytol dose ranged from 1 to 11 mg per kilogram of body weight (≤510 mg iron; rate ≤45 mg iron/sec). There were no systematic changes in vital signs after ferumoxytol administration (P > .05). No severe, life-threatening, or fatal AEs occurred. Eighty-three (1.9%) of 4240 AEs were related or possibly related to ferumoxytol infusions (75 mild [1.8%], eight moderate [0.2%]). Thirty-one AEs were classified as allergiclike reactions using ACR criteria but were consistent with minor infusion reactions observed with parenteral iron. Conclusion Diagnostic ferumoxytol use was well tolerated, associated with no serious adverse events, and implicated in few adverse reactions. Registry results indicate a positive safety profile for ferumoxytol use in MRI. © RSNA, 2019 Online supplemental material is available for this article.


Assuntos
Meios de Contraste/efeitos adversos , Óxido Ferroso-Férrico/efeitos adversos , Imageamento por Ressonância Magnética , Uso Off-Label , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Sistema de Registros
14.
J Cardiovasc Magn Reson ; 21(1): 51, 2019 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-31422771

RESUMO

BACKGROUND: Studies suggest that right ventricular (RV) fibrosis is associated with RV remodeling and long-term outcomes in patients with tetralogy of Fallot (TOF). Pre-operative hypoxia may increase expression of hypoxia inducible factor-1-alpha (HIF1α) and promote transforming growth factor ß1 (TGFß1)-mediated fibrosis. We hypothesized that there would be associations between: (1) RV fibrosis and RV function, (2) HIF1α variants and RV fibrosis, and (3) HIF1α variants and RV function among post-surgical TOF cases. METHODS: We retrospectively measured post-surgical fibrotic load (indexed volume and fibrotic score) from 237 TOF cases who had existing cardiovascular magnetic resonance imaging using late gadolinium enhancement (LGE), and indicators of RV remodeling (i.e., ejection fraction [RVEF] and end-diastolic volume indexed [RVEDVI]). Genetic data were available in 125 cases. Analyses were conducted using multivariable linear mixed-effects regression with a random intercept and multivariable generalized Poisson regression with a random intercept. RESULTS: Indexed fibrotic volume and fibrotic score significantly decreased RVEF by 1.6% (p = 0.04) and 0.9% (p = 0.03), respectively. Indexed fibrotic volume and score were not associated with RVEDVI. After adjusting for multiple comparisons, 6 of the 48 HIF1α polymorphisms (representing two unique signals) were associated with fibrotic score. None of the HIF1α polymorphisms were associated with indexed fibrotic volume, RVEDVI, or RVEF. CONCLUSION: The association of some HIF1α polymorphisms and fibrotic score suggests that HIF1α may modulate the fibrotic response in TOF.


Assuntos
Subunidade alfa do Fator 1 Induzível por Hipóxia/genética , Imagem Cinética por Ressonância Magnética , Polimorfismo de Nucleotídeo Único , Tetralogia de Fallot/diagnóstico por imagem , Função Ventricular Direita , Remodelação Ventricular , Procedimentos Cirúrgicos Cardíacos , Meios de Contraste/administração & dosagem , Feminino , Fibrose , Gadolínio DTPA/administração & dosagem , Predisposição Genética para Doença , Humanos , Lactente , Recém-Nascido , Masculino , Fenótipo , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Tetralogia de Fallot/genética , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/cirurgia , Resultado do Tratamento
15.
J Pediatr Hematol Oncol ; 41(1): e47-e50, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30080754

RESUMO

An open-label, pilot study was conducted to evaluate deferasirox/deferiprone combination chelation therapy in adult patients with transfusion-dependent thalassemia and severe iron overload. Enrollment proved difficult. Nine patients (median age, 27.4 y; ferritin, 4965 ng/mL; liver iron concentration, 28.5 mg/g dry weight; cardiac T2*, 13.3 ms) received treatment. Two were withdrawn for treatment-related adverse effects. Arthralgia (4 patients) and gastrointestinal symptoms (5 patients) were common; no episodes of neutropenia/agranulocytosis occurred. Adherence difficulties were common. Of 6 patients with 12 to 18 months follow-up, 3 showed improvement in cardiac T2* and 2 in liver iron. Combination oral chelation may be effective but adverse effects and adherence challenges may limit efficacy.


Assuntos
Transfusão de Sangue , Deferasirox/administração & dosagem , Deferiprona/administração & dosagem , Sobrecarga de Ferro/tratamento farmacológico , Talassemia/terapia , Adulto , Deferasirox/efeitos adversos , Deferiprona/efeitos adversos , Quimioterapia Combinada , Feminino , Seguimentos , Humanos , Sobrecarga de Ferro/etiologia , Masculino , Projetos Piloto
16.
Circulation ; 135(7): 671-682, 2017 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-28031423

RESUMO

BACKGROUND: Patients with a single ventricle experience a high rate of brain injury and adverse neurodevelopmental outcome; however, the incidence of brain abnormalities throughout surgical reconstruction and their relationship with cerebral blood flow, oxygen delivery, and carbon dioxide reactivity remain unknown. METHODS: Patients with a single ventricle were studied with magnetic resonance imaging scans immediately prior to bidirectional Glenn (pre-BDG), before Fontan (BDG), and then 3 to 9 months after Fontan reconstruction. RESULTS: One hundred sixty-eight consecutive subjects recruited into the project underwent 235 scans: 63 pre-BDG (mean age, 4.8±1.7 months), 118 BDG (2.9±1.4 years), and 54 after Fontan (2.4±1.0 years). Nonacute ischemic white matter changes on T2-weighted imaging, focal tissue loss, and ventriculomegaly were all more commonly detected in BDG and Fontan compared with pre-BDG patients (P<0.05). BDG patients had significantly higher cerebral blood flow than did Fontan patients. The odds of discovering brain injury with adjustment for surgical stage as well as ≥2 coexisting lesions within a patient decreased (63%-75% and 44%, respectively) with increasing amount of cerebral blood flow (P<0.05). In general, there was no association of oxygen delivery (except for ventriculomegaly in the BDG group) or carbon dioxide reactivity with neurological injury. CONCLUSIONS: Significant brain abnormalities are commonly present in patients with a single ventricle, and detection of these lesions increases as children progress through staged surgical reconstruction, with multiple coexisting lesions more common earlier than later. In addition, this study demonstrated that BDG patients had greater cerebral blood flow than did Fontan patients and that an inverse association exists of various indexes of cerebral blood flow with these brain lesions. However, CO2 reactivity and oxygen delivery (with 1 exception) were not associated with brain lesion development. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02135081.


Assuntos
Circulação Cerebrovascular , Doenças do Sistema Nervoso/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 92(2): 222-246, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-30160001

RESUMO

The stimulus to create this document was the recognition that ionizing radiation-guided cardiovascular procedures are being performed with increasing frequency, leading to greater patient radiation exposure and, potentially, to greater exposure to clinical personnel. While the clinical benefit of these procedures is substantial, there is concern about the implications of medical radiation exposure. ACC leadership concluded that it is important to provide practitioners with an educational resource that assembles and interprets the current radiation knowledge base relevant to cardiovascular procedures. By applying this knowledge base, cardiovascular practitioners will be able to select procedures optimally, and minimize radiation exposure to patients and to clinical personnel. "Optimal Use of Ionizing Radiation in Cardiovascular Imaging - Best Practices for Safety and Effectiveness" is a comprehensive overview of ionizing radiation use in cardiovascular procedures and is published online. To provide the most value to our members, we divided the print version of this document into 2 focused parts. "Part I: Radiation Physics and Radiation Biology" addresses radiation physics, dosimetry and detrimental biologic effects. "Part II: Radiologic Equipment Operation, Dose-Sparing Methodologies, Patient and Medical Personnel Protection" covers the basics of operation and radiation delivery for the 3 cardiovascular imaging modalities (x-ray fluoroscopy, x-ray computed tomography, and nuclear scintigraphy). For each modality, it includes the determinants of radiation exposure and techniques to minimize exposure to both patients and to medical personnel.


Assuntos
Técnicas de Imagem Cardíaca/normas , Doenças Cardiovasculares/diagnóstico por imagem , Exposição Ocupacional/normas , Doses de Radiação , Exposição à Radiação/normas , Benchmarking/normas , Consenso , Medicina Baseada em Evidências/normas , Humanos , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Segurança do Paciente/normas , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Medição de Risco , Fatores de Risco
18.
Catheter Cardiovasc Interv ; 92(2): 203-221, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-30160013

RESUMO

The stimulus to create this document was the recognition that ionizing radiation-guided cardiovascular procedures are being performed with increasing frequency, leading to greater patient radiation exposure and, potentially, to greater exposure for clinical personnel. Although the clinical benefit of these procedures is substantial, there is concern about the implications of medical radiation exposure. The American College of Cardiology leadership concluded that it is important to provide practitioners with an educational resource that assembles and interprets the current radiation knowledge base relevant to cardiovascular procedures. By applying this knowledge base, cardiovascular practitioners will be able to select procedures optimally, and minimize radiation exposure to patients and to clinical personnel. Optimal Use of Ionizing Radiation in Cardiovascular Imaging: Best Practices for Safety and Effectiveness is a comprehensive overview of ionizing radiation use in cardiovascular procedures and is published online. To provide the most value to our members, we divided the print version of this document into 2 focused parts. Part I: Radiation Physics and Radiation Biology addresses the issue of medical radiation exposure, the basics of radiation physics and dosimetry, and the basics of radiation biology and radiation-induced adverse effects. Part II: Radiological Equipment Operation, Dose-Sparing Methodologies, Patient and Medical Personnel Protection covers the basics of operation and radiation delivery for the 3 cardiovascular imaging modalities (x-ray fluoroscopy, x-ray computed tomography, and nuclear scintigraphy) and will be published in the next issue of the Journal.


Assuntos
Técnicas de Imagem Cardíaca/normas , Doenças Cardiovasculares/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação/normas , Benchmarking/normas , Consenso , Medicina Baseada em Evidências/normas , Humanos , Segurança do Paciente/normas , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Medição de Risco , Fatores de Risco
19.
J Cardiovasc Magn Reson ; 20(1): 63, 2018 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-30208894

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) feature tracking is increasingly used to quantify cardiac mechanics from cine CMR imaging, although validation against reference standard techniques has been limited. Furthermore, studies have suggested that commonly-derived metrics, such as peak global strain (reported in 63% of feature tracking studies), can be quantified using contours from just two frames - end-diastole (ED) and end-systole (ES) - without requiring tracking software. We hypothesized that mechanics derived from feature tracking would not agree with those derived from a reference standard (displacement-encoding with stimulated echoes (DENSE) imaging), and that peak strain from feature tracking would agree with that derived using simple processing of only ED and ES contours. METHODS: We retrospectively identified 88 participants with 186 pairs of DENSE and balanced steady state free precession (bSSFP) image slices acquired at the same locations across two institutions. Left ventricular (LV) strains, torsion, and dyssynchrony were quantified from both feature tracking (TomTec Imaging Systems, Circle Cardiovascular Imaging) and DENSE. Contour-based strains from bSSFP images were derived from ED and ES contours. Agreement was assessed with Bland-Altman analyses and coefficients of variation (CoV). All biases are reported in absolute percentage. RESULTS: Comparison results were similar for both vendor packages (TomTec and Circle), and thus only TomTec Imaging System data are reported in the abstract for simplicity. Compared to DENSE, mid-ventricular circumferential strain (Ecc) from feature tracking had acceptable agreement (bias: - 0.4%, p = 0.36, CoV: 11%). However, feature tracking significantly overestimated the magnitude of Ecc at the base (bias: - 4.0% absolute, p < 0.001, CoV: 18%) and apex (bias: - 2.4% absolute, p = 0.01, CoV: 15%), underestimated torsion (bias: - 1.4 deg/cm, p < 0.001, CoV: 41%), and overestimated dyssynchrony (bias: 26 ms, p < 0.001, CoV: 76%). Longitudinal strain (Ell) had borderline-acceptable agreement (bias: - 0.2%, p = 0.77, CoV: 19%). Contour-based strains had excellent agreement with feature tracking (biases: - 1.3-0.2%, CoVs: 3-7%). CONCLUSION: Compared to DENSE as a reference standard, feature tracking was inaccurate for quantification of apical and basal LV circumferential strains, longitudinal strain, torsion, and dyssynchrony. Feature tracking was only accurate for quantification of mid LV circumferential strain. Moreover, feature tracking is unnecessary for quantification of whole-slice strains (e.g. base, apex), since simplified processing of only ED and ES contours yields very similar results to those derived from feature tracking. Current feature tracking technology therefore has limited utility for quantification of cardiac mechanics.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Adolescente , Adulto , Fenômenos Biomecânicos , Criança , Bases de Dados Factuais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/normas , Kentucky , Imagem Cinética por Ressonância Magnética/normas , Masculino , Philadelphia , Valor Preditivo dos Testes , Padrões de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Torção Mecânica , Disfunção Ventricular Esquerda/fisiopatologia , Adulto Jovem
20.
Pediatr Cardiol ; 39(2): 275-282, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29063953

RESUMO

The purpose of this study was to assess the safety and indications for cardiac magnetic resonance (CMR) with myocardial perfusion imaging (MPI) in a cohort of children and young adults. A retrospective review of 178 children and young adults who underwent CMR with MPI was performed. Studies were categorized based on study protocols as MPI with resting perfusion only, adenosine stress MPI, exercise-induced stress MPI, and MPI for cardiac mass diagnosis. Relevant clinical history, exam indications, and adverse reactions following gadolinium-based contrast agent and adenosine administration were recorded. Studies were reviewed for the presence of myocardial perfusion defects, wall motion abnormalities, and delayed myocardial enhancement. The most common indications from MPI were congenital heart disease (CHD), Kawasaki disease, anomalous coronary artery, or myocardial mass characterization. Of these, 51% were protocoled with adenosine stress, 23% without stress, 6% with exercise stress, and 20% for cardiac mass evaluation. Excluding patients for myocardial mass evaluation, MPI defects were present in 16% (14 with adenosine stress, 1 with exercise stress, 8 on resting studies only). For cardiac mass evaluation, a mass was confirmed in 58%. No adverse reactions occurred with intravenous administration of a gadolinium-based contrast agent. Three self-limited adverse reactions, 2 patients with chest pain, and 1 patient with bradycardia, occurred following adenosine administration. MPI is a safe modality for the evaluation of pediatric and young adults with minimal adverse events. The most common indications for MPI were for the evaluation of CHD, Kawasaki disease, anomalous coronary artery, or myocardial mass characterization.


Assuntos
Teste de Esforço/métodos , Cardiopatias/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Adenosina/administração & dosagem , Adenosina/efeitos adversos , Adolescente , Criança , Pré-Escolar , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Feminino , Humanos , Lactente , Imagem Cinética por Ressonância Magnética/efeitos adversos , Masculino , Imagem de Perfusão do Miocárdio/efeitos adversos , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA