Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
1.
Ultraschall Med ; 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39222928

RESUMO

PURPOSE: Before removal of retained pancreatic stents placed during endoscopic retrograde cholangiopancreatography to avoid post-ERCP pancreatitis an imaging is recommended. The aim of the present study was to evaluate a new ultrasound-based algorithm. MATERIALS AND METHODS: Patients who received a pancreatic stent for PEP prophylaxis were included. Straight 5Fr (0.035inch) 6cm stents with an external flap that were visualized by ultrasound were removed endoscopically with no further imaging. If the ultrasound result reported the stent to be dislodged or was inconclusive, X-ray imaging was performed. The endpoints were positive and negative predictive value, specificity, sensitivity, and contingency coefficient between ultrasound and X-ray and/or endoscopy. RESULTS: In the present study, 88 patients were enrolled. X-ray was performed in 23 (26%) patients. Accordingly, the ultrasound algorithm saved an X-ray examination in 65 cases, leading to a reduction of 74%. Stents were retained in 67 patients (76%) and visualized correctly by ultrasound in 54 patients with a sensitivity of 81%. The positive predictive value was 83%. Specificity was 48% because ultrasound described 10/21 dislodged stents correctly. The negative predictive value was 43% as 10/23 stents were correctly classified as dislodged by ultrasound. In 11 patients (13%), esophagogastroduodenoscopy was performed even though the pancreatic stent was already dislodged. CONCLUSION: A novel ultrasound-based algorithm reduced the need for X-ray imaging by three quarters. To avoid unnecessary endoscopic examinations, the algorithm should be implemented with a learning phase and procedures should be performed by experienced examiners. An important limitation might be the stent lengths, as shorter stents might be more difficult to visualize by ultrasound. __________________ Hintergrund: Aktuell wird vor der Entfernung von prophylaktisch gelegten Pankreasstents nach einer endoskopischen retrograden Cholangiopankreatikographie eine Bildgebung empfohlen. Ziel der vorliegenden Studie war es, einen neuen ultraschallbasierten Algorithmus zu evaluieren. MATERIAL UND METHODEN: Eingeschlossen wurden Patienten nach prophylatischer Pankreasstentanalage . Gerade 5 Fr-Stents (0.035 inch) mit 6 cm Länge vom externen Flange, die mittels Ultraschall sichtbar waren, wurden endoskopisch ohne weitere Bildgebung entfernt. Wenn das Ultraschallergebnis den Stent als disloziert beschrieb, wurde eine Röntgenaufnahme durchgeführt. Die Endpunkte waren der positive und negative Vorhersagewert, die Spezifität, Sensitivität und der Kontingenzkoeffizient zwischen Ultraschall und Röntgen und/oder Endoskopie. Ergebnisse: 88 Patienten wurden in die Studie eingeschlossen. Bei 23 (26%) Patienten musste eine Röntgenaufnahme durchgeführt werden. Entsprechend hat der Ultraschallalgorithmus in 65 Fällen (74%) eine Röntgenuntersuchung eingespart. Stents waren bei 67 Patienten (76%) verblieben und wurden bei 54 Patienten korrekt mit einer Sensitivität von 81% mittels Ultraschall visualisiert. Der positive Vorhersagewert betrug 83%. Die Spezifität betrug 48%, da der Ultraschall 10/21 dislozierte Stents korrekt beschrieb. Der negative Vorhersagewert betrug 43%, da 10/23 Stents korrekt als disloziert klassifiziert wurden. Bei 11 Patienten (13%) wurde eine Ösophagogastroduodenoskopie durchgeführt, obwohl der Pankreasstent bereits disloziert war. Fazit: Ein ultraschallbasierter Algorithmus reduzierte den Bedarf an Röntgenbildgebung um drei Viertel. Um unnötige endoskopische Untersuchungen zu vermeiden, sollte der Algorithmus mit einer Lernphase implementiert und das Verfahren von erfahrenen Untersuchern durchgeführt werden. Eine wichtige Einschränkung könnte die Länge der Stents sein, da kürzere Stents mit Ultraschall schwieriger zu visualisieren sein könnten.

2.
Liver Transpl ; 29(9): 940-951, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37016761

RESUMO

Fluorescence confocal microscopy (FCM) is a rapidly evolving tool that provides real-time virtual HE images of native tissue. Data about the potential of FCM as an alternative to frozen sections for the evaluation of donor liver specimens are lacking so far. The aim of the current study was to determine the value of FCM in liver specimens according to the criteria of the German Society for Organ Procurement. In this prospective study, conventional histology and FCM scans of 50 liver specimens (60% liver biopsies, 26% surgical specimens, and 14% donor samples) were evaluated according to the German Society for Organ Procurement. A comparison of FCM scans and conventional frozen sections revealed almost perfect levels of agreement for cholangitis (κ = 0.877), fibrosis (κ = 0.843), and malignancy (κ = 0.815). Substantial levels of agreement could be obtained for macrovesicular steatosis (κ = 0.775), inflammation (κ = 0.763), necrosis (κ = 0.643), and steatohepatitis (κ = 0.643). Levels of agreement were moderate for microvesicular steatosis (κ = 0.563). The strength of agreement between frozen sections and FCM was superior to the comparison of conventional HE and FCM imaging. We introduce FCM as a potential alternative to the frozen section that may represent a novel approach to liver transplant pathology where timely feedback is crucial and the deployment of human resources is becoming increasingly difficult.


Assuntos
Fígado Gorduroso , Transplante de Fígado , Humanos , Transplante de Fígado/efeitos adversos , Estudos Prospectivos , Doadores Vivos , Biópsia , Fígado Gorduroso/patologia , Microscopia Confocal/métodos
3.
Gut ; 71(2): 402-414, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33479052

RESUMO

OBJECTIVE: Liver stiffness measurement (LSM) is a tool used to screen for significant fibrosis and portal hypertension. The aim of this retrospective multicentre study was to develop an easy tool using LSM for clinical outcomes in advanced chronic liver disease (ACLD) patients. DESIGN: This international multicentre cohort study included a derivation ACLD patient cohort with valid two-dimensional shear wave elastography (2D-SWE) results. Clinical and laboratory parameters at baseline and during follow-up were recorded. LSM by transient elastography (TE) was also recorded if available. The primary outcome was overall mortality. The secondary outcome was the development of first/further decompensation. RESULTS: After screening 2148 patients (16 centres), 1827 patients (55 years, 62.4% men) were included in the 2D-SWE cohort, with median liver SWE (L-SWE) 11.8 kPa and a model for end stage liver disease (MELD) score of 8. Combination of MELD score and L-SWE predict independently of mortality (AUC 0.8). L-SWE cut-off at ≥20 kPa combined with MELD ≥10 could stratify the risk of mortality and first/further decompensation in ACLD patients. The 2-year mortality and decompensation rates were 36.9% and 61.8%, respectively, in the 305 (18.3%) high-risk patients (with L-SWE ≥20 kPa and MELD ≥10), while in the 944 (56.6%) low-risk patients, these were 1.1% and 3.5%, respectively. Importantly, this M10LS20 algorithm was validated by TE-based LSM and in an additional cohort of 119 patients with valid point shear SWE-LSM. CONCLUSION: The M10LS20 algorithm allows risk stratification of patients with ACLD. Patients with L-SWE ≥20 kPa and MELD ≥10 should be followed closely and receive intensified care, while patients with low risk may be managed at longer intervals.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatias/diagnóstico , Hepatopatias/mortalidade , Adulto , Algoritmos , Doença Crônica , Feminino , Humanos , Hepatopatias/etiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Taxa de Sobrevida
4.
Gastrointest Endosc ; 95(3): 471-479, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34562471

RESUMO

BACKGROUND AND AIMS: Direct endoscopic necrosectomy (DEN) of walled-off pancreatic necrosis (WOPN) lacks dedicated instruments and requires repetitive and cumbersome procedures. This study evaluated the safety and efficacy of a new powered endoscopic debridement (PED) system designed to simultaneously resect and remove solid debris within WOPN. METHODS: This was a single-arm, prospective, multicenter, international device trial conducted from November 2018 to August 2019 at 10 sites. Patients with WOPN ≥6 cm and ≤22 cm and with >30% solid debris were enrolled. The primary endpoint was safety through 21 days after the last DEN procedure. Efficacy outcomes included clearance of necrosis, procedural time, adequacy of debridement, number of procedures until resolution, hospital stay duration, and quality of life. RESULTS: Thirty patients (mean age, 55 years; 60% men) underwent DEN with no device-related adverse events. Of 30 patients, 15 (50%) achieved complete debridement in 1 session and 20 (67%) achieved complete debridement within 2 or fewer sessions. A median of 1.5 interventions (range, 1-7) were required. Median hospital stay was 10 days (interquartile range, 22). There was an overall reduction of 91% in percent necrosis within WOPN from baseline to follow-up and 85% in collection volume. Baseline WOPN volume was positively correlated with the total number of interventions (ρ = .363, P = .049). CONCLUSIONS: The new PED system seems to be a safe and effective treatment tool for WOPN, resulting in fewer interventions and lower hospital duration when compared with published data on using conventional instruments. Randomized controlled trials comparing the PED system with conventional DEN are needed. (Clinical trial registration number: NCT03694210.).


Assuntos
Pancreatite Necrosante Aguda , Drenagem/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Necrose/cirurgia , Pâncreas/cirurgia , Pancreatite Necrosante Aguda/cirurgia , Estudos Prospectivos , Qualidade de Vida , Estudos Retrospectivos , Stents , Resultado do Tratamento
5.
Transpl Infect Dis ; 24(4): e13868, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35598281

RESUMO

OBJECTIVES: Stenosis of the biliary anastomosis predisposes liver graft recipients to bacterial cholangitis. Antibiotic therapy (AT) is performed according to individual clinical judgment, but duration of AT remains unclear. METHODS: All liver graft recipients with acute cholangitis according to the Tokyo criteria grade 1 and 2 after endoscopic retrograde cholangiography (ERC) were included. Outcome of patients treated with short AT (<7 days) was compared to long AT (>6 days). Recurrent cholangitis (RC) within 28 days was the primary end point. RESULTS: In total, 30 patients were included with a median of 313 (range 34-9849) days after liver transplantation until first proven cholangitis. Among 62 cases in total, 51/62 (82%) were graded as Tokyo-1 and 11/62 (18%) as Tokyo-2. Overall median duration of AT was 6 days (1-14) with 36 cases (58%) receiving short AT and 26 (42%) receiving long AT. RC was observed in 10 (16%) cases, without significant difference in occurrence of RC in short versus long AT cases. CRP and bilirubin were significantly higher in patients with long AT, while low serum albumin and low platelets were associated with risk of RC. CONCLUSION: A shorter antibiotic course than 7 days shows good results in selected, ERC-treated patients for post-transplantation biliary strictures.


Assuntos
Colangite , Colestase , Transplante de Fígado , Antibacterianos/uso terapêutico , Colangite/tratamento farmacológico , Colestase/etiologia , Colestase/cirurgia , Humanos , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos
6.
J Gastroenterol Hepatol ; 37(6): 1076-1082, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35261084

RESUMO

BACKGROUND AND AIM: The main disadvantage of plastic stents is the high rate of stent occlusion. The usual replacement interval of biliary plastic stents is 3 months. This study aimed to investigate if a shorter interval of 6-8 weeks impacts the median premature exchange rate (mPER) in benign and malignant biliary strictures. METHODS: All cases with endoscopic retrograde cholangiopancreatography (ERCP) and plastic stent placement were retrospectively analyzed since establishing an elective replacement interval of every 6-8 weeks at our institution and mPER was determined. RESULTS: A total of 3979 ERCPs (1199 patients) were analyzed, including 1262 (31.7%) malignant and 2717 (68.3%) benign cases, respectively. The median stent patency (mSP) was 41 days (range 14-120) for scheduled stent exchanges, whereas it was 17 days (1-75) for prematurely exchanged stents. The mPER was significantly higher for malignant (28.1%, 35-50%) compared with benign strictures (15.2%, 10-28%), P < 0.0001, respectively. mSP was significantly shorter in cases with only one stent (34 days [1-87] vs 41 days [1-120]) and in cases with only a 7-Fr stent (28 days [2-79]) compared with a larger stent (34 days [1-87], P = 0.001). Correspondingly, mPER was significantly higher in cases with only one stent (23% vs 16.2%, P < 0.0001) and only a 7-Fr stent (31.3% vs 22.4%, P = 0.03). CONCLUSION: A shorter replacement interval does not seem to lead to a clinically meaningful reduction of mPER in benign and malignant strictures. Large stents and multiple stenting should be favored as possible.


Assuntos
Colestase , Colangiopancreatografia Retrógrada Endoscópica , Colestase/diagnóstico por imagem , Colestase/etiologia , Colestase/cirurgia , Constrição Patológica , Humanos , Plásticos , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
7.
Ultraschall Med ; 43(5): 473-478, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32674185

RESUMO

PURPOSE: Hepatic hydrothorax (HH) is defined as transudate in the pleural cavity in patients with decompensated liver cirrhosis (DC) without concomitant cardiopulmonary or pleural disease. It is associated with high short-term mortality. HH can evolve via translocation through diaphragmatic gaps. The aim of this study was to evaluate the feasibility and safety of injecting ultrasound contrast medium into the peritoneal cavity to detect HH. MATERIALS AND METHODS: This study included patients with concomitant ascites and pleural effusion who were admitted to our hospital between March 2009 and February 2019. A peritoneal catheter was inserted and ultrasound contrast medium was injected into the peritoneal cavity. In parallel, the peritoneal and pleural cavities were monitored for up to 10 minutes. RESULTS: Overall, 43 patients were included. The median age was 60 years and the majority of patients were male (n = 32, 74 %). Most patients presented with right-sided pleural effusion (n = 32, 74 %), 3 (7 %) patients with left-sided and 8 (19 %) patients had bilateral pleural effusion. In 12 (28 %) patients ascites puncture was not safe due to low volume ascites. Thus, the procedure could be performed in 31 (72 %) patients. No adverse events occurred. In 16 of 31 (52 %) patients we could visualize a trans-diaphragmic flow of microbubbles. The median time until transition was 120 seconds. CONCLUSION: Our clinical real-world experience supports the safety and feasibility of intraperitoneal ultrasound contrast medium application to detect HH in patients with DC, as a non-radioactive real-time visualization of HH. Our study comprises the largest cohort and longest experience using this method to date.


Assuntos
Hidrotórax , Derrame Pleural , Ascite/complicações , Ascite/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Hidrotórax/complicações , Hidrotórax/etiologia , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Derrame Pleural/complicações , Derrame Pleural/diagnóstico por imagem , Ultrassonografia
8.
J Viral Hepat ; 28(11): 1604-1613, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34342081

RESUMO

Long-term effects on cirrhosis and portal hypertension of direct antiviral agent (DAA)-based eradication of hepatitis C virus (HCV) are still under debate. We analysed dynamics of liver and spleen elastography to assess potential regression of cirrhosis and portal hypertension 3 years post-treatment. Fifty-four patients with HCV-associated cirrhosis and DAA-induced SVR were included. Liver and spleen stiffness were measured at baseline (BL), end of treatment (EOT), 24 weeks after EOT (FU24) and 1, 2 and 3 (FU144) years post-treatment by transient liver elastography (L-TE) and point shear wave elastography (pSWE) using acoustic radiation force impulse (ARFI) of the liver (L-ARFI) and spleen (S-ARFI). Biochemical, virological and clinical data were also obtained. Liver stiffness assessed by L-TE decreased between BL [median (range), 32.5(9.1-75) kPa] and EOT [21.3(6.7-73.5) kPa; p < .0001] and EOT and FU144 [16(4.1-75) kPa; p = .006]. L-ARFI values improved between EOT [2.5(1.2-4.1) m/s] and FU144 [1.7(0.9-4.1) m/s; p = .001], while spleen stiffness remained unchanged. Overall, L-TE improved in 38 of 54 (70.4%) patients at EOT and 29 of 38 (76.3%) declined further until FU144, whereas L-ARFI values decreased in 30/54 (55.6%) patients at EOT and continued to decrease in 28/30 (93.3%) patients at FU144. Low bilirubin and high albumin levels at BL were associated with improved L-ARFI values (p = .048) at EOT or regression of cirrhosis (<12.5 kPa) by L-TE at FU144 (p = .005), respectively. Liver stiffness, but not spleen stiffness, continued to decline in a considerable proportion of patients with advanced liver disease after HCV eradication.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatite C Crônica , Hepatite C , Hipertensão Portal , Antivirais/uso terapêutico , Seguimentos , Hepatite C/tratamento farmacológico , Hepatite C Crônica/complicações , Hepatite C Crônica/tratamento farmacológico , Hepatite C Crônica/patologia , Humanos , Hipertensão Portal/tratamento farmacológico , Hipertensão Portal/patologia , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/tratamento farmacológico , Estudos Longitudinais , Estudos Prospectivos , Resposta Viral Sustentada , Resultado do Tratamento
9.
Eur Radiol ; 31(3): 1578-1587, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32902745

RESUMO

OBJECTIVES: To compare liver stiffness measurement (LSM) provided by Canon 2D-shear wave elastography (2D-SWE) and transient elastography (TE), the latter being the reference method. METHODS: Prospective study conducted in four European centres from 2015 to 2016 including patients with various chronic liver diseases who had LSMs with both 2D-SWE and TE on the same day. Median of 10 valid measurements (in kPa) was used for comparison using paired t test, Pearson correlation, intraclass correlation coefficient (ICC) and Bland-Altman plot. The ability of 2D-SWE to stratify patient according to recognised LSM-TE thresholds was assessed by ROC curve analysis. RESULTS: Six hundred forty patients were scanned, where 593 (92.7%), 572 (89.4%) and 537 (83.9%) had reliable LSMs by TE, 2D-SWE and both combined, respectively. In the latter (n = 537, 310 [57.7%] male, mean 55.3 ± 14.8 years), median LSM-TE and LSM-2D-SWE had a mean of 10.1 ± 9.4 kPa (range 2.4-75) and 9.1 ± 6.1 kPa (range 3.6-55.7) (paired t test: p < 0.001), respectively. These were significantly correlated (Pearson r = 0.932, p < 0.001, ICC 0.850 (0.825-0.872), bias 0.99 ± 4.33 kPa [95% limits of agreement - 9.48 to + 7.49] with proportional error towards higher LSM values). LSM-2D-SWE values significantly increased with TE categories (ANOVA: p < 0.001). AUROCs ranged from 0.935 ± 0.010 (95% CI 0.910-0.954) to 0.973 ± 0.009 (95% CI 0.955-0.985), resulting in correct classification of 390/537 (73%) patients. Three 2D-SWE measurements were sufficient for reliable LSMs. CONCLUSION: LSM using 2D-SWE correlates well with TE. It tends to underestimate higher stages of liver fibrosis but correctly classifies the majority of patients. It may be used in TE-derived algorithms to manage patients. KEY POINTS: • Liver stiffness measurement (LSM) by 2D-shear wave elastography (2D-SWE) and transient elastography (TE) are strongly correlated. • 2D-SWE shows proportionately lower LSM values compared to TE, particularly with the higher LSM range. • Three individual measurements by 2D-SWE are sufficient to assess LSM reliably.


Assuntos
Técnicas de Imagem por Elasticidade , Humanos , Fígado/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes
10.
Z Gastroenterol ; 59(7): 657-664, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33728617

RESUMO

BACKGROUND AND AIMS: Liver cirrhosis is a systemic disease that substantially impacts the body's physiology, especially in advanced stages. Accordingly, the outcome of patients with cirrhosis requiring intensive care treatment is poor. We aimed to analyze the impact of cirrhosis on mortality of intensive care unit (ICU) patients compared to other frequent chronic diseases and conditions. METHODS: In this retrospective study, patients admitted over three years to the ICU of the Department of Medicine of the University Hospital Frankfurt were included. Patients were matched for age, gender, pre-existing conditions, simplified acute physiology score (SAPS II), and therapeutic intervention scoring system (TISS). RESULTS: A total of 567 patients admitted to the ICU were included in the study; 99 (17.5 %) patients had liver cirrhosis. A total of 129 patients were included in the matched cohort for the sensitivity analysis. In-hospital mortality was higher in cirrhotic patients than non-cirrhotic patients (p < 0.0001) in the entire and matched cohort. Liver cirrhosis remained one of the strongest independent predictors of in-hospital mortality (entire cohort p = 0.001; matched cohort p = 0.03) along with dialysis and need for transfusion in the multivariate logistic regression analysis. Furthermore, in the cirrhotic group, the need for kidney replacement therapy (p < 0.001) and blood transfusion (p < 0.001) was significantly higher than in the non-cirrhotic group.  CONCLUSIONS: In the presented study, liver cirrhosis was one of the strongest predictors of in-hospital mortality in patients needing intensive care treatment along with dialysis and the need for ventilation. Therefore, concerted efforts are needed to improve cirrhotic patients' outcomes, prevent disease progression, and avoid complications with the need for ICU treatment in the early stages of the disease.


Assuntos
Unidades de Terapia Intensiva , Cirrose Hepática , Cuidados Críticos , Mortalidade Hospitalar , Humanos , Cirrose Hepática/diagnóstico , Cirrose Hepática/terapia , Prognóstico , Estudos Retrospectivos
11.
Ultraschall Med ; 42(2): 178-186, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32663881

RESUMO

BACKGROUND: This prospective multicenter study funded by the DEGUM assesses the diagnostic accuracy of standardized contrast-enhanced ultrasound (CEUS) for the noninvasive diagnosis of hepatocellular carcinoma (HCC) in high-risk patients. METHODS: Patients at high risk for HCC with a histologically proven focal liver lesion on B-mode ultrasound were recruited prospectively in a multicenter approach. Clinical and imaging data were entered via online entry forms. The diagnostic accuracies for the noninvasive diagnosis of HCC were compared for the conventional interpretation of standardized CEUS at the time of the examination (= CEUS on-site) and the two CEUS algorithms ESCULAP (Erlanger Synopsis for Contrast-enhanced Ultrasound for Liver lesion Assessment in Patients at risk) and CEUS LI-RADS (Contrast-Enhanced UltraSound Liver Imaging Reporting and Data System). RESULTS: 321 patients were recruited in 43 centers; 299 (93.1 %) had liver cirrhosis. The diagnosis according to histology was HCC in 256 cases, and intrahepatic cholangiocarcinoma (iCCA) in 23 cases. In the subgroup of cirrhotic patients (n = 299), the highest sensitivity for the diagnosis of HCC was achieved with the CEUS algorithm ESCULAP (94.2 %) and CEUS on-site (90.9 %). The lowest sensitivity was reached with the CEUS LI-RADS algorithm (64 %; p < 0.001). However, the specificity of CEUS LI-RADS (78.9 %) was superior to that of ESCULAP (50.9 %) and CEUS on-site (64.9 %; p < 0.001). At the same time, the negative predictive value (NPV) of CEUS LI-RADS was significantly inferior to that of ESCULAP (34.1 % vs. 67.4 %; p < 0.001) and CEUS on-site (62.7 %; p < 0.001). The positive predictive values of all modalities were high (around 90 %), with the best results seen for CEUS LI-RADS and CEUS on-site. CONCLUSION: This is the first multicenter, prospective comparison of standardized CEUS and the recently developed CEUS-based algorithms in histologically proven liver lesions in cirrhotic patients. Our results reaffirm the excellent diagnostic accuracy of CEUS for the noninvasive diagnosis of HCC in high-risk patients. However, on-site diagnosis by an experienced examiner achieves an almost equal diagnostic accuracy compared to CEUS-based diagnostic algorithms.


Assuntos
Neoplasias dos Ductos Biliares , Carcinoma Hepatocelular , Neoplasias Hepáticas , Algoritmos , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Prospectivos , Ultrassonografia
12.
J Clin Monit Comput ; 35(5): 1085-1092, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-32734356

RESUMO

Standard monitoring of heart rate, blood pressure and arterial oxygen saturation during endoscopy is recommended by current guidelines on procedural sedation. A number of studies indicated a reduction of hypoxic (art. oxygenation < 90% for > 15 s) and severe hypoxic events (art. oxygenation < 85%) by additional use of capnography. Therefore, U.S. and the European guidelines comment that additional capnography monitoring can be considered in long or deep sedation. Integrated Pulmonary Index® (IPI) is an algorithm-based monitoring parameter that combines oxygenation measured by pulse oximetry (art. oxygenation, heart rate) and ventilation measured by capnography (respiratory rate, apnea > 10 s, partial pressure of end-tidal carbon dioxide [PetCO2]). The aim of this paper was to analyze the value of IPI as parameter to monitor the respiratory status in patients receiving propofol sedation during PEG-procedure. Patients reporting for PEG-placement under sedation were randomized 1:1 in either standard monitoring group (SM) or capnography monitoring group including IPI (IM). Heart rate, blood pressure and arterial oxygen saturation were monitored in SM. In IM additional monitoring was performed measuring PetCO2, respiratory rate and IPI. Capnography and IPI values were recorded for all patients but were only visible to the endoscopic team for the IM-group. IPI values range between 1 and 10 (10 = normal; 8-9 = within normal range; 7 = close to normal range, requires attention; 5-6 = requires attention and may require intervention; 3-4 = requires intervention; 1-2 requires immediate intervention). Results on capnography versus standard monitoring of the same study population was published previously. A total of 147 patients (74 in SM and 73 in IM) were included in the present study. Hypoxic events occurred in 62 patients (42%) and severe hypoxic events in 44 patients (29%), respectively. Baseline characteristics were equally distributed in both groups. IPI = 1, IPI < 7 as well as the parameters PetCO2 = 0 mmHg and apnea > 10 s had a high sensitivity for hypoxic and severe hypoxic events, respectively (IPI = 1: 81%/81% [hypoxic/severe hypoxic event], IPI < 7: 82%/88%, PetCO2: 69%/68%, apnea > 10 s: 84%/84%). All four parameters had a low specificity for both hypoxic and severe hypoxic events (IPI = 1: 13%/12%, IPI < 7: 7%/7%, PetCO2: 29%/27%, apnea > 10 s: 7%/7%). In multivariate analysis, only SM and PetCO2 = 0 mmHg were independent risk factors for hypoxia. IPI (IPI = 1 and IPI < 7) as well as the individual parameters PetCO2 = 0 mmHg and apnea > 10 s allow a fast and convenient conclusion on patients' respiratory status in a morbid patient population. Sensitivity is good for most parameters, but specificity is poor. In conclusion, IPI can be a useful metric to assess respiratory status during propofol-sedation in PEG-placement. However, IPI was not superior to PetCO2 and apnea > 10 s.


Assuntos
Gastrostomia , Propofol , Capnografia , Sedação Consciente , Humanos , Monitorização Fisiológica , Estudos Prospectivos , Respiração
13.
Gastroenterology ; 156(5): 1264-1281.e4, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30660725

RESUMO

Nonalcoholic fatty liver disease (NAFLD) is estimated to afflict approximately 1 billion individuals worldwide. In a subset of NAFLD patients, who have the progressive form of NAFLD termed nonalcoholic steatohepatitis (NASH), it can progress to advanced fibrosis, cirrhosis, hepatocellular carcinoma, and liver-related morbidity and mortality. NASH is typically characterized by a specific pattern on liver histology, including steatosis, lobular inflammation, and ballooning with or without peri-sinusoidal fibrosis. Thus, key issues in NAFLD patients are the differentiation of NASH from simple steatosis and identification of advanced hepatic fibrosis. Until now, liver biopsy has been the gold standard for identifying these 2 critical end points, but has well-known limitations, including invasiveness; rare but potentially life-threatening complications; poor acceptability; sampling variability; and cost. Furthermore, due to the epidemic proportion of individuals with NAFLD worldwide, liver biopsy evaluation is impractical, and noninvasive assessment for the diagnosis of NASH and fibrosis is needed. Although much of the work remains to be done in establishing cost-effective strategies for screening for NASH, advanced fibrosis, and cirrhosis, in this review, we summarize the current state of the noninvasive assessment of liver disease in NAFLD, and we provide an expert synthesis of how these noninvasive tools could be utilized in clinical practice. Finally, we also list the key areas of research priorities in this area to move forward clinical practice.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico , Testes de Função Hepática , Fígado , Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Ultrassonografia/métodos , Biomarcadores/sangue , Biópsia , Humanos , Fígado/diagnóstico por imagem , Fígado/metabolismo , Fígado/patologia , Cirrose Hepática/sangue , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Espectroscopia de Ressonância Magnética , Hepatopatia Gordurosa não Alcoólica/sangue , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
14.
J Viral Hepat ; 27(7): 690-698, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32096310

RESUMO

The impact of direct-acting antiviral (DAA) therapies on fibrosis regression remains uncertain. In the current study, we prospectively evaluated dynamics of liver stiffness by transient elastography (TE) in patients with chronic HCV infection receiving DAA-based treatment. Patients (260) were enrolled in the German Hepatitis C-Registry (DHC-R), a national multicentre real-world cohort. Liver stiffness (LS) was assessed at baseline, end of treatment (EOT) and 24 weeks after EOT (FU24) by TE. Biochemical, virological and clinical data were obtained in parallel. In patients with SVR, there was a significant improvement of LS between baseline (median [range], 8.6 [1.7-73.5] kPa) and FU24 (7.9 [1.7-75 kPa]; P < .0001) as well as between EOT (8.4 [1.7-73.5 kPa]) and FU24 [P < .0001]. Stratified by fibrosis stage, patients classified into F4 had higher magnitude of LS reduction between BL (median [range], 25.1 [13.5-73.5] kPa) and FU24 (21.5 [3.1-75] kPa; P = .002) compared to those with F2-F3 (8.9 [7.1-12.4] kPa and 8.8 [4.2-29.1]; P = .060) or F0-F1 (5.3 [1.7-7] kPa and 5.2 [1.7-7.7]; P = .064). In cirrhotic patients, low platelets were significantly associated with lack of liver stiffness improvement, both at EOT (P = .018) and at FU24 (P = .012). LS significantly correlated with ALT (r = .371), AST (r = .552), platelets (r = -.499), GGT (r = .250), bilirubin (r = .230), APRI score (r = .512), FIB-4 score (r = .517) and FORNS index (r = .562); P < .0001. Liver elastography improved significantly in our real-world cohort after DAA-based therapy. As LS correlates similarly with transaminase levels and serum fibrosis markers, it might reflect both reduction of necroinflammation and fibrosis regression.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatite C Crônica , Fígado , Antivirais/uso terapêutico , Alemanha , Hepatite C Crônica/tratamento farmacológico , Humanos , Fígado/patologia , Cirrose Hepática/patologia , Sistema de Registros , Resposta Viral Sustentada , Resultado do Tratamento
15.
J Gastroenterol Hepatol ; 35(3): 401-407, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31222832

RESUMO

BACKGROUND AND AIM: A number of studies were able to show a reduction of hypoxemia episodes during procedural sedation through the use of capnography (CA). The present study investigates the number of episodes of hypoxemia during percutaneous endoscopic gastrostomy (PEG) placement with propofol sedation comparing standard monitoring (SM) versus SM with additional CA surveillance. METHODS: In this single center randomized controlled trial, 150 patients were prospectively randomized 1:1 in either the SM group or the CA group after stratification for ASA class, PEG method (push or pull method), presence of head and neck tumor, and tracheostomy. CA analysis was performed for all patients but was blinded for the endoscopic team in the SM group. RESULTS: In the SM group, 57% episodes of hypoxemia (SpO2  < 90% for > 15 s) and 41% episodes of severe hypoxemia (SpO2  < 85% for > 15 s) were observed in comparison with 28% and 20% in the CA group, respectively. Odds ratios for hypoxemia and severe hypoxemia were 0.29 (confidence interval 0.15-0.57; P = 0.0005) and 0.35 (confidence interval 0.17-0.73; P = 0.008) in favor of the CA group. On average, CA was able to detect imminent mild and severe hypoxemia 83 and 99 s before standard monitoring. Standard monitoring represented an independent risk factor for hypoxemia and severe hypoxemia. CONCLUSIONS: Respiratory complications of sedation during PEG placement are frequent events. CA is able to detect imminent hypoxemia at an early time point. This allows an early intervention and consecutively the avoidance of mild and severe hypoxemia. Therefore, CA monitoring can be recommended particularly during PEG insertion procedures.


Assuntos
Capnografia , Sedação Consciente/métodos , Endoscopia Gastrointestinal/métodos , Gastrostomia/métodos , Hipóxia/diagnóstico , Complicações Intraoperatórias/diagnóstico , Monitorização Fisiológica/métodos , Idoso , Feminino , Humanos , Hipóxia/prevenção & controle , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
16.
Z Gastroenterol ; 58(2): 152-159, 2020 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-31863426

RESUMO

Patients with indeterminate biliary stricture frequently pose a challenge in the clinical management. Patients with malignant and potentially resectable diseases should be treated surgically as soon as possible. On the other hand, in patients with benign diseases which might be cured with medial treatment, surgery should be avoided. This review shall provide a concise overview on the diagnostic yield of currently available endoscopic methods as well as describe methods of potential relevance in the future.


Assuntos
Ductos Biliares/patologia , Colangiopancreatografia Retrógrada Endoscópica , Colestase/terapia , Constrição Patológica , Colestase/etiologia , Drenagem , Humanos
17.
J Viral Hepat ; 26(2): 224-230, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30315694

RESUMO

Treatment decisions are based on extent of fibrosis in patients with chronic hepatitis C (HCV) infection. Noninvasive diagnostic tools may help to avoid liver biopsy. We investigated the diagnostic accuracy of noncommercial serum scores in comparison with transient elastography (TE). Data analysis was undertaken based on 2458 patients enrolled in the German Hepatitis C Registry, in a prospective, observational study. Aspartate aminotransferase-to-platelet ratio index (APRI), FORNS index and FIB-4 score were calculated and the diagnostic accuracy was compared to TE. As estimated by TE, 955 (38.9%) patients had absence of significant fibrosis (SF), 736 (29.9%) patients had SF, and 767 (31.2%) patients were shown to have cirrhosis. Patients with absence of SF had a sustained virological response (SVR) rate of 97.9%, whereas SVR was attained in 96.2% and 92.2% in those with SF and cirrhosis, respectively (P < 0.0001). The area under the receiver operator characteristic curve (AUROC), sensitivity and specificity in discriminating of SF were 0.789, 0.596 and 0.939 by APRI; 0.838, 0.852 and 0.748 by FORNS index; and 0.828, 0.658 and 0.946 by FIB-4 score. AUROCs for the prediction of cirrhosis, sensitivity and specificity were 0.881, 0.851 and 0.854 by APRI; 0.846, 0.948 and 0.628 by FORNS index; and 0.907, 0.907 and 0.848 by FIB-4 score. In conclusion, in the present multicentre real-world cohort, SF and cirrhosis were predicted with high accuracy with noncommercial serum markers using TE as reference. Further prospective long-term follow-up is necessary to compare biomarkers with TE concerning liver-related outcome and overall mortality.


Assuntos
Antivirais/uso terapêutico , Técnicas de Imagem por Elasticidade , Hepatite C Crônica/diagnóstico , Cirrose Hepática/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aspartato Aminotransferases/sangue , Biomarcadores/sangue , Feminino , Alemanha , Hepatite C Crônica/tratamento farmacológico , Humanos , Fígado/diagnóstico por imagem , Fígado/virologia , Cirrose Hepática/diagnóstico , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , Reprodutibilidade dos Testes , Resposta Viral Sustentada , Adulto Jovem
18.
Hepatology ; 67(1): 260-272, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28370257

RESUMO

Two-dimensional shear wave elastography (2D-SWE) has proven to be efficient for the evaluation of liver fibrosis in small to moderate-sized clinical trials. We aimed at running a larger-scale meta-analysis of individual data. Centers which have worked with Aixplorer ultrasound equipment were contacted to share their data. Retrospective statistical analysis used direct and paired receiver operating characteristic and area under the receiver operating characteristic curve (AUROC) analyses, accounting for random effects. Data on both 2D-SWE and liver biopsy were available for 1,134 patients from 13 sites, as well as on successful transient elastography in 665 patients. Most patients had chronic hepatitis C (n = 379), hepatitis B (n = 400), or nonalcoholic fatty liver disease (n = 156). AUROCs of 2D-SWE in patients with hepatitis C, hepatitis B, and nonalcoholic fatty liver disease were 86.3%, 90.6%, and 85.5% for diagnosing significant fibrosis and 92.9%, 95.5%, and 91.7% for diagnosing cirrhosis, respectively. The AUROC of 2D-SWE was 0.022-0.084 (95% confidence interval) larger than the AUROC of transient elastography for diagnosing significant fibrosis (P = 0.001) and 0.003-0.034 for diagnosing cirrhosis (P = 0.022) in all patients. This difference was strongest in hepatitis B patients. CONCLUSION: 2D-SWE has good to excellent performance for the noninvasive staging of liver fibrosis in patients with hepatitis B; further prospective studies are needed for head-to-head comparison between 2D-SWE and other imaging modalities to establish disease-specific appropriate cutoff points for assessment of fibrosis stage. (Hepatology 2018;67:260-272).


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatite B Crônica/complicações , Hepatite C Crônica/complicações , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha , Bases de Dados Factuais , Progressão da Doença , Feminino , Seguimentos , Hepatite B Crônica/diagnóstico por imagem , Hepatite B Crônica/patologia , Hepatite C Crônica/diagnóstico por imagem , Hepatite C Crônica/patologia , Humanos , Imuno-Histoquímica , Cirrose Hepática/etiologia , Cirrose Hepática/virologia , Masculino , Pessoa de Meia-Idade , Razão de Chances , Curva ROC , Índice de Gravidade de Doença , Adulto Jovem
19.
Pancreatology ; 19(1): 39-43, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30502123

RESUMO

OBJECTIVES: The risk of post-ERCP pancreatitis (PEP) can be reduced effectively by the placement of a self dislodging pancreatic stent. The present study analyzed whether a prolonged interval until stent passage evaluation and removal of retained stents is associated with an increased risk for clinically relevant complications. METHODS: In the retrospective study 182 patients receiving a pancreatic stent for PEP prophylaxis were included and clinical data and complications until documented spontaneous stent dislodgement or removal were analyzed. RESULTS: The main indication for ERCP was choledocholithiasis (40.1%) followed by malignant stenosis (30.8%). Stent passage evaluation was performed in 34.1% at day 1-4, 23.6% at day 5-10, 17.6% at day 11-28 and 24.7% at day >28. PEP occurred in 13.1% of patients with no case of severe PEP. No association between PEP and day of stent passage evaluation (p = 0.719), retention of the pancreatic stent at time of evaluation (0.867) or prolonged stent retention >10 days (0.234) was observed. Only the duration of the procedure was associated with risk for PEP (p = 0.037). Besides PEP only one clinically relevant complication was observed in the cohort (0.5%) which was a late possibly stent related pancreatitis at day 9 after the procedure that resolved completely. CONCLUSIONS: A prolonged interval for stent passage evaluation and stent retention is not associated with an increase of clinically relevant complications. A later evaluation and extraction of retained stents might be acceptable in selected cases where an additional endoscopic procedure can be saved due to a planned follow-up endoscopy.


Assuntos
Pancreatopatias/cirurgia , Complicações Pós-Operatórias , Stents/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pancreatopatias/complicações , Pancreatopatias/prevenção & controle , Fatores de Risco , Adulto Jovem
20.
J Intensive Care Med ; 34(11-12): 955-966, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-28718341

RESUMO

BACKGROUND: Computed tomography of the head (HCT) is a widely used diagnostic tool, especially for emergency and trauma patients. However, the diagnostic yield and outcomes of HCT for patients on medical intensive care units (MICUs) are largely unknown. METHODS: We retrospectively evaluated all head CTs from patients admitted to a single-center MICU during a 5-year period for CT indications, diagnostic yield, and therapeutic consequences. Uni- and multivariate analyses for the evaluation of risk factors for positive head CT were conducted. RESULTS: Six hundred ninety (18.8%) of all patients during a 5-year period underwent HCT; 78.7% had negative CT results, while 21.3% of all patients had at least 1 new pathological finding. The main indication for acquiring CT scan of the head was an altered mental state (AMS) in 23.5%, followed by a new focal neurology in 20.7% and an inadequate wake up after stopping sedation in 14.9% of all patients. The most common new finding was intracerebral bleeding in 6.4%. In 6.7%, the CT scan itself led to a change of therapy of any kind. Admission after resuscitation or a new focal neurology were independent predictors of a positive CT. Psychic alteration and AMS were both independent predictors of a higher chance of a negative head CT. Positive HCT during MICU is an independent predictor of lower survival. CONCLUSIONS: New onset of focal neurologic deficit seems to be a good predictor for a positive CT, while AMS and psychic alterations seem to be very poor predictors. A positive head CT is an independent predictor of death for MICU patients.


Assuntos
Cuidados Críticos/estatística & dados numéricos , Estado Terminal , Cabeça/diagnóstico por imagem , Unidades de Terapia Intensiva/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA