Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Opt Express ; 23(2): 636-41, 2015 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-25835822

RESUMO

A contact poling technique for domain engineering of ferroelectrics using a micro-structured silicon electrode is demonstrated on Rb:KTiOPO4. High quality QPM gratings were reproducibly fabricated. The silicon electrode is reusable and the technique potentially suitable when complex structures with sub-µm features are to be domain engineered, which otherwise is incompatible with conventional photolithography. A non-negligible domain broadening was seen and attributed to a low nucleation rate using this type of electrode. However, under the appropriate poling conditions, this could be exploited to obtain a QPM grating with a short pitch (2 µm), equal to half of the electrode period.

2.
Micromachines (Basel) ; 14(4)2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-37420999

RESUMO

Lift-off processing is a common method of pattern transfer for different nanofabrication applications. With the emergence of chemically amplified and semi-amplified resist systems, the possibilities for pattern definition via electron beam lithography has been widened. We report a reliable and simple lift-off process for dense nanostructured pattern in CSAR62. The pattern is defined in a single layer CSAR62 resist mask for gold nanostructures on silicon. The process offers a slimmed down pathway for pattern definition of dense nanostructures with varied feature size and an up to 10 nm thick gold layer. The resulting patterns from this process have been successfully used in metal assisted chemical etching applications.

3.
Biomed Microdevices ; 14(5): 885-93, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22714394

RESUMO

Using the latest innovations in microfabrication technology, 3-dimensional microfluidic cell culture systems have been developed as an attractive alternative to traditional 2-dimensional culturing systems as a model for long-term microscale cell-based research. Most microfluidic systems are based on the embedding of cells in hydrogels. However, physiologically realistic conditions based on hydrogels are difficult to obtain and the systems are often too complicated. We have developed a microfluidic cell culture device that incorporates a biodegradable rigid 3D polymer scaffold using standard soft lithography methods. The device permits repeated high-resolution fluorescent imaging of live cell populations within the matrix over a 4 week period. It was also possible to track cell development at the same spatial location throughout this time. In addition, human primary periodontal ligament cells were induced to produce quantifiable calcium deposits within the system. This simple and versatile device should be readily applicable for cell-based studies that require long-term culture and high-resolution bioimaging.


Assuntos
Técnicas de Cultura de Células/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/instrumentação , Materiais Biocompatíveis , Técnicas de Cultura de Células/métodos , Proliferação de Células , Células Cultivadas , Desenho de Equipamento , Humanos , Hidrogéis/química , Processamento de Imagem Assistida por Computador/métodos , Microfluídica/métodos , Microscopia Confocal/métodos , Modelos Teóricos , Ligamento Periodontal/citologia
4.
Micromachines (Basel) ; 13(3)2022 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-35334744

RESUMO

X-ray zone plates made from gold are common optical components used in X-ray imaging experiments. These nanostructures are normally fabricated using a combination of electron-beam lithography and gold electroplating with cyanide gold baths. In this study, we present a gold electroplating process in a miniaturized gold-suplphite bath. The miniaturization is enabled by on-chip reference plating areas with well defined sizes, offering a reliable way to control the height of the structures by carefully choosing the plating time at a given current density in accordance with a calibration curve. Fabricated gold zone plates were successfully used in X-ray imaging experiments with synchrotron radiation. Although gold electroplating of nanostructures is a well-established method, details about the actual process are often missing in the literature. Therefore, we think that our detailed descriptions and explanations will be helpful for other researchers that would like to fabricate similar structures.

5.
Cell Rep Methods ; 2(7): 100256, 2022 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-35880015

RESUMO

Here, we present a methodology based on multiplexed fluorescence screening of two- or three-dimensional cell cultures in a newly designed multichambered microwell chip, allowing direct assessment of drug or immune cell cytotoxic efficacy. We establish a framework for cell culture, formation of tumor spheroids, fluorescence labeling, and imaging of fixed or live cells at various magnifications directly in the chip together with data analysis and interpretation. The methodology is demonstrated by drug cytotoxicity screening using ovarian and non-small cell lung cancer cells and by cellular cytotoxicity screening targeting tumor spheroids of renal carcinoma and ovarian carcinoma with natural killer cells from healthy donors. The miniaturized format allowing long-term cell culture, efficient screening, and high-quality imaging of small sample volumes makes this methodology promising for individualized cytotoxicity tests for precision medicine.


Assuntos
Antineoplásicos , Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Técnicas de Cultura de Células , Esferoides Celulares
6.
Biomed Microdevices ; 13(4): 683-93, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21465090

RESUMO

We present a novel microwell array platform suited for various cell-imaging assays where single cell resolution is important. The platform consists of an exchangeable silicon-glass microchip for cell biological applications and a custom made holder that fits in conventional microscopes. The microchips presented here contain arrays of miniature wells, where the well sizes and layout have been designed for different applications, including single cell imaging, studies of cell-cell interactions or ultrasonic manipulation of cells. The device has been designed to be easy to use, to allow long-term assays (spanning several days) with read-outs based on high-resolution imaging or high-content screening. This study is focused on screening applications and an automatic cell counting protocol is described and evaluated. Finally, we have tested the device and automatic counting by studying the selective survival and clonal expansion of 721.221 B cells transfected to express HLA Cw6-GFP compared to untransfected 721.221 B cells when grown under antibiotic selection for 3 days. The device and automated analysis protocol make up the foundation for development of several novel cellular imaging assays.


Assuntos
Citometria de Fluxo/instrumentação , Análise em Microsséries/instrumentação , Análise em Microsséries/métodos , Linfócitos B/citologia , Contagem de Células , Técnicas de Cultura de Células/métodos , Linhagem Celular , Desenho de Equipamento , Citometria de Fluxo/métodos , Humanos , Microscopia Eletrônica , Microtecnologia , Análise de Célula Única/instrumentação , Análise de Célula Única/métodos , Transfecção
7.
Sci Signal ; 14(684)2021 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-34035142

RESUMO

Immune synapses are large-scale, transient molecular assemblies that serve as platforms for antigen presentation to B and T cells and for target recognition by cytotoxic T cells and natural killer (NK) cells. The formation of an immune synapse is a tightly regulated, stepwise process in which the cytoskeleton, cell surface receptors, and intracellular signaling proteins rearrange into supramolecular activation clusters (SMACs). We generated artificial immune synapses (AIS) consisting of synthetic and natural ligands for the NK cell-activating receptors LFA-1 and CD16 by microcontact printing the ligands into circular-shaped SMAC structures. Live-cell imaging and analysis of fixed human NK cells in this reductionist system showed that the spatial distribution of activating ligands influenced the formation, stability, and outcome of NK cell synapses. Whereas engagement of LFA-1 alone promoted synapse initiation, combined engagement of LFA-1 and CD16 was required for the formation of mature synapses and degranulation. Organizing LFA-1 and CD16 ligands into donut-shaped AIS resulted in fewer long-lasting, symmetrical synapses compared to dot-shaped AIS. NK cells spreading evenly over either AIS shape exhibited similar arrangements of the lytic machinery. However, degranulation only occurred in regions containing ligands that therefore induced local signaling, suggesting the existence of a late checkpoint for degranulation. Our results demonstrate that the spatial organization of ligands in the synapse can affect its outcome, which could be exploited by target cells as an escape mechanism.


Assuntos
Sinapses Imunológicas , Células Matadoras Naturais , Antígeno-1 Associado à Função Linfocitária , Receptores de IgG , Degranulação Celular , Citoesqueleto , Proteínas Ligadas por GPI , Humanos
8.
Lab Chip ; 10(20): 2727-32, 2010 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-20820481

RESUMO

We demonstrate a microplate platform for parallelized manipulation of particles or cells by frequency-modulated ultrasound. The device, consisting of a silicon-glass microchip and a single ultrasonic transducer, enables aggregation, positioning and high-resolution microscopy of cells distributed in an array of 100 microwells centered on the microchip. We characterize the system in terms of temperature control, aggregation and positioning efficiency, and cell viability. We use time-lapse imaging to show that cells continuously exposed to ultrasound are able to divide and remain viable for at least 12 hours inside the device. Thus, the device can be used to induce and maintain aggregation in a parallelized fashion, facilitating long-term microscopy studies of, e.g., cell-cell interactions.


Assuntos
Agregação Celular/fisiologia , Citometria de Fluxo/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Micromanipulação/instrumentação , Ultrassom/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos
9.
Am J Physiol Renal Physiol ; 298(5): F1096-102, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20089672

RESUMO

The primary cilium is a ubiquitous organelle present on most mammalian cells. Malfunction of the organelle has been associated with various pathological disorders, many of which lead to cystic disorders in liver, pancreas, and kidney. Primary cilia have in kidney epithelial cells been observed to generate intracellular calcium in response to fluid flow, and disruption of proteins involved in this calcium signaling lead to autosomal dominant polycystic kidney disease, implying a direct connection between calcium signaling and cyst formation. It has also been shown that there is a significant lag between the onset of flow and initiation of the calcium signal. The present study focuses on the mechanics of cilium bending and the resulting calcium signal. Visualization of real-time cilium movements in response to different types of applied flow showed that the bending is fast compared with the initiation of calcium increase. Mathematical modeling of cilium and surrounding membrane was performed to deduce the relation between bending and membrane stress. The results showed a delay in stress buildup that was similar to the delay in calcium signal. Our results thus indicate that the delay in calcium response upon cilia bending is caused by mechanical properties of the cell membrane.


Assuntos
Sinalização do Cálcio/fisiologia , Cílios/fisiologia , Células Epiteliais/fisiologia , Hidrodinâmica , Rim/fisiologia , Animais , Fenômenos Biomecânicos , Linhagem Celular , Membrana Celular/fisiologia , Cães , Células Epiteliais/citologia , Rim/citologia , Modelos Animais , Modelos Teóricos , Transdução de Sinais/fisiologia
10.
Eur J Intern Med ; 75: 71-78, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31982283

RESUMO

BACKGROUND: Glucose is a routine emergency sample. General guidelines for inpatient hyperglycemia are scarce, except in myocardial infarction, stroke, and perioperative/ICU. Previous studies found admission glucose associated with increased mortality in specific conditions. Scandinavian data, and for general patients, are scarcer. We investigated admission glucose levels, 30-day mortality, and length-of-stay (LoS), in a Swedish hospital. METHODS: From 8146 emergency visits data regarding age, gender, dates of admission, discharge and death, diagnoses, admission p-glucose, s-sodium, s-potassium, b-hemoglobin, b-WBC and s-CRP, was collected, and for 6283 information regarding diagnosis of diabetes the previous 5 years. Visits were grouped in hypoglycemia (≤4.0), normoglycemia (>4.0-≤7.0), modest (>7.0-≤11.1) and severe hyperglycemia (>11.1) mmol/l. RESULTS: Short-term mortality was 1.5% in the normoglycemic, 2.6% in the hypoglycemic, 4.0-4.5% in modest and severe hyperglycemia, p < 0.001; Cox proportional hazard ratios (HR) for groups of patients without/with diabetes were 6.8; 1; 3.4; 4.4/7.3; 3.9; 4.0; 2.1 compared to the normoglycemic without diabetes (p 0.0001-0.05); adjusted for age, and concurrent levels of sodium, potassium, Hb, WBC and CRP 1.51 (1.07-2.1, p 0.02) with modest hyperglycemia, and 1.08 (0.60-1.95, p 0.80) in severe hyperglycemia. Mean LoS was 1.2 and 1.7 days longer with modest and severe hyperglycemia. CONCLUSIONS: Short-term mortality increased substantially with admission hypo- and hyperglycemia for patients both with and without diabetes, irrespective of treating medical specialty, main discharge diagnosis, or concurrent laboratory values. Patients with diabetes (16%) were older, with higher glucose levels at admission, and with a different pattern of the association of admission glucose and mortality.


Assuntos
Hiperglicemia , Medicina , Glicemia , Pré-Escolar , Mortalidade Hospitalar , Humanos , Laboratórios , Tempo de Internação , Estudos Retrospectivos
11.
Micromachines (Basel) ; 11(3)2020 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-32183040

RESUMO

Zone plates are diffractive optics commonly used in X-ray microscopes. Here, we present a wet-chemical approach for fabricating high aspect ratio Pd/Si zone plate optics aimed at the hard X-ray regime. A Si zone plate mold is fabricated via metal-assisted chemical etching (MACE) and further metalized with Pd via electroless deposition (ELD). MACE results in vertical Si zones with high aspect ratios. The observed MACE rate with our zone plate design is 700 nm/min. The ELD metallization yields a Pd density of 10.7 g/cm 3 , a value slightly lower than the theoretical density of 12 g/cm 3 . Fabricated zone plates have a grid design, 1:1 line-to-space-ratio, 30 nm outermost zone width, and an aspect ratio of 30:1. At 9 keV X-ray energy, the zone plate device shows a first order diffraction efficiency of 1.9%, measured at the MAX IV NanoMAX beamline. With this work, the possibility is opened to fabricate X-ray zone plates with low-cost etching and metallization methods.

12.
Sci Rep ; 9(1): 10672, 2019 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-31337806

RESUMO

Natural killer (NK) cell cytotoxicity in tissue is dependent on the ability of NK cells to migrate through the extracellular matrix (ECM) microenvironment. Traditional imaging studies of NK cell migration and cytotoxicity have utilized 2D surfaces, which do not properly reproduce the structural and mechanical cues that shape the migratory response of NK cells in vivo. Here, we have combined a microwell assay that allows long-term imaging and tracking of small, well-defined populations of NK cells with an interstitial ECM-like matrix. The assay allows for long-term imaging of NK-target cell interactions within a confined 3D volume. We found marked differences in motility between individual cells with a small fraction of the cells moving slowly and being confined to a small volume within the matrix, while other cells moved more freely. A majority of NK cells also exhibited transient variation in their motility, alternating between periods of migration arrest and movement. The assay could be used as a complement to in vivo imaging to study human NK cell heterogeneity in migration and cytotoxicity.


Assuntos
Ensaios de Migração de Leucócitos/métodos , Movimento Celular/fisiologia , Colágeno/metabolismo , Matriz Extracelular/fisiologia , Células Matadoras Naturais/fisiologia , Comunicação Celular , Humanos , Imagem com Lapso de Tempo/métodos
13.
Lab Chip ; 8(10): 1648-57, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18813386

RESUMO

We present the design, fabrication and successful testing of a 14x14x4 mm3 integrated electronic narcotics sensing system which consists of only four parts. The microsystem absorbs airborne narcotics molecules and performs a liquid assay using an integrated quartz crystal microbalance (QCM). A vertically conductive double-sided adhesive foil (VCAF) was used and studied as a novel material for LOC and MEMS applications and provides easy assembly, electrical contacting and liquid containment. The system was tested for measuring cocaine and ecstasy, with successful detection of amounts as small as 100 ng and 200 ng, respectively. These levels are of interest in security activities in customs, prisons and by the police.


Assuntos
Eletrônica , Entorpecentes/análise , Integração de Sistemas , Desenho de Equipamento
14.
Lab Chip ; 6(12): 1504-9, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17203153

RESUMO

A novel micromachined interface for airborne sample-to-liquid adsorption and droplet-to-liquid transfer was designed and fabricated. It enables a robust sheet liquid flow serving as an adsorption site. The interface was characterised for flow and pressure properties and tested successfully for the transfer/adsorption of different samples. A qualitative theoretical model of the device characteristics is presented. We also used the interface to introduce a novel method and system for fast detection of dust- and vapour-based narcotics and explosives traces. The microfluidic vapour-to-liquid adsorption interface was coupled to a set of downstream QCM sensors. The system was tested successfully, with 50 ng cocaine samples rendering 15 Hz frequency shifts and with 100 ng heroine samples rendering 50 Hz frequency shifts. Gravitation invariance of the open liquid interface was demonstrated successfully, with the interface mounted upside down as well as vertically. The detection time was reduced to half of the time needed in previous systems. Machine size, weight and cost were reduced.


Assuntos
Anticorpos/química , Técnicas Biossensoriais/instrumentação , Cocaína/química , Heroína/química , Microfluídica/instrumentação , Microfluídica/métodos , Adsorção , Aerossóis/química , Técnicas Biossensoriais/métodos , Desenho de Equipamento , Gases , Tamanho da Partícula , Transição de Fase , Sensibilidade e Especificidade , Silício/química , Propriedades de Superfície
15.
Methods Mol Biol ; 1441: 87-106, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27177659

RESUMO

NK cell heterogeneity has primarily been studied either on the population level, measuring average responses, or on the single cell level by flow cytometry, providing static snapshots. These approaches have certain drawbacks, not enabling dynamic observations of single cells over extended periods of time. One of the primary limitations of single cell imaging has been throughput; it has been challenging to collect data for many cells due to their dynamic nature and migrating out of the field of view. Spatially confining cells combined with automated fluorescence microscopy enables the simultaneous monitoring of many NK cells in parallel for extended periods of time (>12 h). Such an approach allows us to dissect how the sum of individual NK cell responses translates to the global average response typically observed.


Assuntos
Células Matadoras Naturais/citologia , Análise de Célula Única/métodos , Imagem com Lapso de Tempo/métodos , Movimento Celular , Humanos , Procedimentos Analíticos em Microchip , Microscopia de Fluorescência
16.
Front Immunol ; 7: 119, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27092139

RESUMO

Here, we report a screening platform for assessment of the cytotoxic potential of individual natural killer (NK) cells within larger populations. Human primary NK cells were distributed across a silicon-glass microchip containing 32,400 individual microwells loaded with target cells. Through fluorescence screening and automated image analysis, the numbers of NK and live or dead target cells in each well could be assessed at different time points after initial mixing. Cytotoxicity was also studied by time-lapse live-cell imaging in microwells quantifying the killing potential of individual NK cells. Although most resting NK cells (≈75%) were non-cytotoxic against the leukemia cell line K562, some NK cells were able to kill several (≥3) target cells within the 12-h long experiment. In addition, the screening approach was adapted to increase the chance to find and evaluate serial killing NK cells. Even if the cytotoxic potential varied between donors, it was evident that a small fraction of highly cytotoxic NK cells were responsible for a substantial portion of the killing. We demonstrate multiple assays where our platform can be used to enumerate and characterize cytotoxic cells, such as NK or T cells. This approach could find use in clinical applications, e.g., in the selection of donors for stem cell transplantation or generation of highly specific and cytotoxic cells for adoptive immunotherapy.

17.
Front Immunol ; 6: 196, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25972868

RESUMO

T cells are pivotal in the immune defense against cancers and infectious agents. To mount an effector response against cancer cells, T cells need to migrate to the cancer-site, engage in contacts with cancer cells, and perform their effector functions. Adoptive T cell therapy is an effective strategy as treatment of complications such as relapse or opportunistic infections after hematopoietic stem cell transplantations. This requires a sufficient amount of cells that are able to expand and respond to tumor or viral antigens. The cytokines interleukin (IL)-2 and IL-7 drive T cell differentiation, proliferation, and survival and are commonly used to expand T cells ex vivo. Here, we have used microchip-based live-cell imaging to follow the migration of individual T cells, their interactions with allogeneic monocytes, cell division, and apoptosis for extended periods of time; something that cannot be achieved by commonly used methods. Our data indicate that cells grown in IL-7 + IL-2 had similar migration and contact dynamics as cells grown in IL-2 alone. However, the addition of IL-7 decreased cell death creating a more viable cell population, which should be beneficial when preparing cells for immunotherapy.

18.
Integr Biol (Camb) ; 5(4): 712-9, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23435966

RESUMO

Natural killer (NK) cells kill virus-infected or cancer cells through the release of cytotoxic granules into a tight intercellular contact. NK cell populations comprise individual cells with varying sensitivity to distinct input signals, leading to disparate responses. To resolve this NK cell heterogeneity, we have designed a novel assay based on ultrasound-assisted cell-cell aggregation in a multiwell chip allowing high-resolution time-lapse imaging of one hundred NK-target cell interactions in parallel. Studying human NK cells' ability to kill MHC class I deficient tumor cells, we show that approximately two thirds of the NK cells display cytotoxicity, with some NK cells being particularly active, killing up to six target cells during the assay. We also report that simultaneous interaction with several susceptible target cells increases the cytotoxic responsiveness of NK cells, which could be coupled to a previously unknown regulatory mechanism with implications for NK-mediated tumor elimination.


Assuntos
Comunicação Celular , Separação Celular/instrumentação , Citometria de Fluxo/instrumentação , Células Matadoras Naturais/fisiologia , Neoplasias Experimentais/fisiopatologia , Sonicação/instrumentação , Análise Serial de Tecidos/instrumentação , Sobrevivência Celular , Células Cultivadas , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Células Matadoras Naturais/citologia , Neoplasias Experimentais/patologia
19.
Front Immunol ; 3: 300, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23060879

RESUMO

Each individual has a heterogeneous pool of NK cells consisting of cells that may be specialized towards specific functional responses such as secretion of cytokines or killing of tumor cells. Many conventional methods are not fit to characterize heterogeneous populations as they measure the average response of all cells. Thus, there is a need for experimental platforms that provide single cell resolution. In addition, there are transient and stochastic variations in functional responses at the single cell level, calling for methods that allow studies of many events over extended periods of time. This paper presents a versatile microchip platform enabling long-term microscopic studies of individual NK cells interacting with target cells. Each microchip contains an array of microwells, optimized for medium or high-resolution time-lapse imaging of single or multiple NK and target cells, or for screening of thousands of isolated NK-target cell interactions. Individual NK cells confined with target cells in small microwells is a suitable setup for high-content screening and rapid assessment of heterogeneity within populations, while microwells of larger dimensions are appropriate for studies of NK cell migration and sequential interactions with multiple target cells. By combining the chip technology with ultrasonic manipulation, NK and target cells can be forced to interact and positioned with high spatial accuracy within individual microwells. This setup effectively and synchronously creates NK-target conjugates at hundreds of parallel positions in the microchip. Thus, this facilitates assessment of temporal aspects of NK-target cell interactions, e.g., conjugation, immune synapse formation, and cytotoxic events. The microchip platform presented here can be used to effectively address questions related to fundamental functions of NK cells that can lead to better understanding of how the behavior of individual cells add up to give a functional response at the population level.

20.
PLoS One ; 5(11): e15453, 2010 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-21103395

RESUMO

New markers are constantly emerging that identify smaller and smaller subpopulations of immune cells. However, there is a growing awareness that even within very small populations, there is a marked functional heterogeneity and that measurements at the population level only gives an average estimate of the behaviour of that pool of cells. New techniques to analyze single immune cells over time are needed to overcome this limitation. For that purpose, we have designed and evaluated microwell array systems made from two materials, polydimethylsiloxane (PDMS) and silicon, for high-resolution imaging of individual natural killer (NK) cell responses. Both materials were suitable for short-term studies (<4 hours) but only silicon wells allowed long-term studies (several days). Time-lapse imaging of NK cell cytotoxicity in these microwell arrays revealed that roughly 30% of the target cells died much more rapidly than the rest upon NK cell encounter. This unexpected heterogeneity may reflect either separate mechanisms of killing or different killing efficiency by individual NK cells. Furthermore, we show that high-resolution imaging of inhibitory synapse formation, defined by clustering of MHC class I at the interface between NK and target cells, is possible in these microwells. We conclude that live cell imaging of NK-target cell interactions in multi-well microstructures are possible. The technique enables novel types of assays and allow data collection at a level of resolution not previously obtained. Furthermore, due to the large number of wells that can be simultaneously imaged, new statistical information is obtained that will lead to a better understanding of the function and regulation of the immune system at the single cell level.


Assuntos
Técnicas de Cultura de Células/métodos , Citotoxicidade Imunológica/imunologia , Vigilância Imunológica/imunologia , Células Matadoras Naturais/imunologia , Técnicas de Cultura de Células/instrumentação , Proliferação de Células , Sobrevivência Celular/imunologia , Células Cultivadas , Células HEK293 , Humanos , Células Matadoras Naturais/citologia , Células Matadoras Naturais/ultraestrutura , Microscopia Eletrônica de Varredura , Microscopia de Fluorescência , Imagem com Lapso de Tempo/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA