Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Neurosci ; 56(11): 5972-5986, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36164804

RESUMO

The hippocampus is an important area for memory encoding and retrieval and is the location of spike timing-dependent plasticity (STDP), a basic phenomenon of learning and memory. STDP is facilitated if acetylcholine (ACh) is released from cholinergic neurons during attentional processes. However, it is unclear how ACh influences postsynaptic changes during STDP induction and determines the STDP magnitude. To address these issues, we obtained patch clamp recordings from CA1 pyramidal neurons to evaluate the postsynaptic changes during stimuli injection in Schaffer collaterals by quantifying baseline amplitudes (i.e., the lowest values elicited by paired pulses comprising STDP stimuli) and action potentials. The results showed that baseline amplitudes were elevated if eserine was applied in the presence of picrotoxin. In addition, muscarinic ACh receptors (mAChRs) contributed more to the baseline amplitude elevation than nicotinic AChRs (nAChRs). Moreover, the magnitude of the STDP depended on the magnitude of the baseline amplitude. However, in the absence of picrotoxin, baseline amplitudes were balanced, regardless of the ACh concentration, resulting in a similar magnitude of the STDP, except under the nAChR alone-activated condition, which showed a larger STDP and lower baseline amplitude induction. This was due to broadened widths of action potentials. These results suggest that activation of mAChRs and nAChRs, which are effective for baseline amplitudes and action potentials, respectively, plays an important role in postsynaptic changes during memory consolidation.


Assuntos
Acetilcolina , Neurônios , Potenciais de Ação/fisiologia , Potenciais da Membrana , Técnicas de Patch-Clamp , Picrotoxina/farmacologia , Neurônios/fisiologia , Hipocampo/fisiologia
2.
Pediatr Int ; 64(1): e15118, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35616194

RESUMO

BACKGROUND: Current cardiopulmonary resuscitation (CPR) guidelines recommend the two-finger technique (TFT) of chest compression (CC) in infants for a single rescuer. We hypothesized that healthcare providers cannot achieve adequate CC depth with TFT, even if using real-time visual feedback (RVF). METHODS: This was a cross-over study, randomizing participants to perform three sets of 2-min continuous CC, comparing (i) TFT with RVF, (ii) the one-hand technique (OHT) without RVF, and (iii) OHT with RVF. A standard CPR trainer manikin of a 3-month-old infant and a monitor/defibrillator that displays and records the quantitative CC quality were used. We set a target compression depth of 40-50 mm and a target compression rate of 100-120/min. Data were analyzed using the Friedman test and Bonferroni correction. Statistical significance was defined as P-value of< 0.05. RESULTS: Fifty-nine healthcare providers participated in the study. The mean compression depth was 24 mm (interquartile range [IQR], 22-26 mm) in TFT with RVF and 43 mm (IQR, 38-48 mm) in OHT without RVF, P < 0.001. The proportion of adequate CC depth was 0% (IQR, 0-0%) in TFT with RVF, 22% (IQR, 5-54%) in OHT without RVF, and 62% (IQR, 29-83%) in OHT with RVF. The mean compression rate was within the target range in all three techniques. CONCLUSIONS: The TFT cannot produce the CC depth that meets the recommendation of the current CPR guidelines for an infant with RVF, whereas the OHT does.


Assuntos
Reanimação Cardiopulmonar , Manequins , Reanimação Cardiopulmonar/métodos , Estudos Cross-Over , Dedos , Humanos , Lactente , Pressão
3.
Acta Radiol ; 62(10): 1333-1340, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33019801

RESUMO

BACKGROUND: The major problems of computed tomography (CT) imaging include radiation exposure and severe artifacts caused by operative implants. PURPOSE: To evaluate the usefulness of the metal artifact reduction algorithm and model-based iterative reconstruction (MBIR) in postoperative low-dose (LD) spine CT. MATERIAL AND METHODS: A CT torso phantom was scanned at standard-dose (SD) and LD settings. The CT images were reconstructed by three methods: hybrid iterative reconstruction (HIR); metal artifact reduction; and MBIR. The radiation dose of the phantom imaging was evaluated by volume CT dose index (mGy), dose length product (DLP, mGy × cm), and effective dose (mSv). The image quality of the six images was visually evaluated and analyzed using Scheffe's paired comparison method. The average preference of each method was calculated based on the comparative scores. The task transfer function (TTF) and noise power spectrum for HIR and MBIR were also measured. RESULTS: The respective radiation-dose-related parameters of the SD and LD conditions were: volume CT dose index = 10.2 and 1.2 mGy; DLP = 277.9 and 33.9 mGy × cm; and effective dose = 4.2 and 0.5 mSv. The average preference for diagnostic acceptability of MBIR at LD was not significantly different from the other reconstructions of SD data. MBIR successfully reduced metal artifacts in the LD condition. The 10% TTF was higher for HIR at SD and higher for MBIR at LD. CONCLUSION: MBIR is useful for LD spine CT after spine surgery with metal implant.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Próteses e Implantes , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Tomografia Computadorizada por Raios X/métodos , Humanos , Vértebras Lombares/diagnóstico por imagem , Metais , Imagens de Fantasmas
4.
Eur Spine J ; 29(11): 2804-2813, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32388669

RESUMO

PURPOSE: To evaluate radiation dose and image quality of cervical spinal computed tomography scanned with low-radiation dose (LD-CT) utilizing model-based iterative reconstruction (MBIR). METHODS: We retrospectively examined 14 patients (65.5 ± 13.9 years) who underwent both standard-radiation-dose CT (SD-CT) reconstructed with hybrid iterative reconstruction and LD-CT of cervical spine. The radiation dose, objective image quality indicator, which includes signal-to-noise and contrast-to-noise, and subjective image quality score of the anatomical landmarks in the SD-CT and LD-CT were statistically compared. In addition, the measurement errors of the length of C3 vertebrae (height, anteroposterior length, inner and outer pedicle diameters) between SD-CT and LD-CT were analyzed. RESULTS: Radiation dose of LD-CT was reduced to one-sixth of the dose of SD-CT. The objective image quality indicator of LD-CT was significantly better than that of SD-CT. The subjective image quality of LD-CT was relatively worse than that of SD-CT but generally graded as clinically accepted or higher. There was no remarkable difference between SD-CT and LD-CT in the measurement value of height and anteroposterior length. Inner pedicle diameter was significantly (0.21 ± 0.13 mm) smaller, and outer pedicle diameter was (0.24 ± 0.14 mm) larger on LD-CT than on SD-CT. CONCLUSION: Cervical spinal LD-CT that utilized MBIR enabled radical decrease in radiation dose and provided sufficient image quality for clinical use. This scanning protocol can be a good alternative for protecting patients from exposure to unnecessary radiation, especially when a patient requires multiple CT scans.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Doses de Radiação , Estudos Retrospectivos , Raios X
5.
Environ Sci Technol ; 53(24): 14123-14133, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31665597

RESUMO

Modern lifestyles demand a number of products derived from petroleum-based sources that eventually cause carbon emissions. The quantification of lifestyle and household consumption impacts upon carbon emissions from both the embodied CO2 (EC) and materially retained carbon (MRC) viewpoints is critical to deriving amelioration policies and meeting emission reduction goals. This study, for the first time, details a methodology to estimate both EC and MRC for Japan, focusing on petrochemicals and woody products utilizing the time series input-output table, physical value tables and the national survey of family income and expenditure, leveraging time series input-output-based material flow analysis (IO-MFA), and structural decomposition analysis (SDA). Findings elucidated hot spots of deleterious consumption by age of householder and the critical factors which underpin them including intensity effects, pattern effects, and demographic shifts over time. Although demographic shifts associated with an aging, shrinking population in Japan decreased EC and MRC, the negative effect reduced in size over time during 1990-2005. Policy implications identify the potential to mitigate approximately 21% of required household emission reductions by 2030 through strategies including recycling initiatives and the recovery of carbon from products covered within current recycling laws and hot spot sectors which are not currently considered such as apparel.


Assuntos
Carbono , Mudança Climática , Dióxido de Carbono , Demografia , Japão
6.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 75(11): 1331-1336, 2019.
Artigo em Japonês | MEDLINE | ID: mdl-31748459

RESUMO

We investigated the causes and trends of incidents related to radiography. From April 2014 to March 2016, 384 incident reports related to radiography were posted. We analyzed based on the nature of the incidents and the experience period of radiological technologist (RT). The types of incidents were 'Incorrect examination order by medical doctor' (50.0%), 'X-ray retake' (24%), 'Incorrect examination procedure' (9.9%), 'Fall or injury of the patient under examination' (3.6%), 'selection error of X-ray detector' (3.1%), 'patient mismatch' (1.8%), 'overdose' (1.3%), and 'others' (a malfunctioning device, trouble of systems and the other) (6.5%). There was no relationship between the number of incidents per person and the experience period as RT; (7.8/person for <3 years of experience, 9.7/person for 3-10 years, 6.4/person for 11-25 years of experience, 7.4/person for <25 years of experience). The experience period as RT are related to some types of incident reduction. 'Fall or injury of the patient under examination' and 'overdose' were more frequently reported by RTs of shorter experience (<3 years and 3-10 years of experience) than RTs of longer experience (11-25 years and <25 of experience). On the other hand, 'patient mismatch' and 'selection error of X-ray detector' were more frequently reported by RTs of long experience than RTs of short experience.


Assuntos
Erros Médicos , Gestão de Riscos , Humanos , Radiografia
7.
Environ Sci Technol ; 52(7): 3899-3907, 2018 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-29547694

RESUMO

To achieve the goals of Paris Agreement, global society is directing much effort in substantially reducing greenhouse gas (GHG) emissions. In addition to energy-related efforts, prevention of carbon release into the atmosphere with carbon capture and storage (CCS) and/or utilization of biomass resources is considered indispensable to achieving the global objective. In this study, considering carbon-containing goods as carbon reservoirs in our society similar to forests and reservoirs enabling CCS, the flow of materially utilized carbon was quantified by input-output-based material flow analysis (IO-MFA). As a result, in 2011, 6.3 Mt-C of petroleum-derived carbon and 7.9 Mt-C of wood-derived carbon were introduced to the Japanese society as end-use products (e.g., automobiles and constructions) in various forms (e.g., plastics and synthetic rubbers). The total amount (14.2 Mt-C) corresponded to 4.1% (52.1 Mt-CO2) of annual CO2 emission in Japan in 2011. Subsequently, by referring to the technology that can treat carbon in the target forms in end-of-life products, the recoverability of carbon as a material has been discussed with respect to each form and end-use of carbon. By numerically showing the necessity and potential of implementing appropriate technologies, this study provides scientific direction for policymakers to establish a quality carbon cycle in our society.


Assuntos
Carbono , Gases de Efeito Estufa , Ciclo do Carbono , Dióxido de Carbono , Florestas , Efeito Estufa , Japão
8.
BMC Med Imaging ; 18(1): 46, 2018 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-30477476

RESUMO

BACKGROUND: This study aimed to determine the prognostic value of positron emission tomography (PET) metabolic parameters-namely metabolic tumor volume (MTV), total lesion glycolysis (TLG), and total lesion retention (TLR)-on fluorine-18 (18F) fluorodeoxyglucose (FDG) and L- [3-18F]-α-methyltyrosine (18F-FAMT) PET/CT in patients with non-small-cell lung cancer (NSCLC). METHODS: The study group comprised 112 NSCLC patients who underwent 18F-FDG and 18F-FAMT PET/CT prior to any therapy. The MTV, TLG, TLR, and maximum standardized uptake value (SUVmax) of the primary tumors were determined. Automatic MTV measurement was performed using PET volume computer assisted reading software. (GE Healthcare). Cox proportional hazards models were built to assess the prognostic value of MTV, TLG (for 18F-FDG), TLR (for 18F-FAMT), SUVmax, T stage, N stage, M stage, clinical stage, age, sex, tumor histological subtype, and treatment method (surgery or other therapy) on overall survival (OS). RESULTS: Higher TNM, higher clinical stage, inoperable status, and higher values for all PET parameters (both 18F-FAMT and 18F-FDG PET) were significantly associated (P < 0.05) with shorter OS. Multivariate analysis revealed that a higher MTV of 18F-FAMT (hazard ratio [HR]: 2.88, CI: 1.63-5.09, P < 0.01) and advanced clinical stage (HR: 5.36, CI: 1.88-15.34, P < 0.01) were significant predictors of shorter OS. CONCLUSIONS: MTV of 18F-FAMT is of prognostic value for OS in NSCLC cases and can help guide decision-making during patient management.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Radioisótopos de Flúor/química , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , alfa-Metiltirosina/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/patologia , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Prognóstico , Estudos Retrospectivos , Sensibilidade e Especificidade , Análise de Sobrevida , Carga Tumoral , alfa-Metiltirosina/química
9.
Artigo em Japonês | MEDLINE | ID: mdl-29459544

RESUMO

Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, the method and the relative differences between organ dose simulation and measurement is unclear. The purpose of this study was to compare organ doses evaluated by Monte Carlo simulation with doses evaluated by in-phantom dosimetry. The simulation software Radimetrics (Bayer) was used for the calculation of organ dose. Measurement was performed with radio-photoluminescence glass dosimeter (RPLD) set at various organ positions within RANDO phantom. To evaluate difference of CT scanner, two different CT scanners were used in this study. Angular dependence of RPLD and measurement of effective energy were performed for each scanner. The comparison of simulation and measurement was evaluated by relative differences. In the results, angular dependence of RPLD at two scanners was 31.6±0.45 mGy for SOMATOM Definition Flash and 29.2±0.18 mGy for LightSpeed VCT. The organ dose was 42.2 mGy (range, 29.9-52.7 mGy) by measurements and 37.7 mGy (range, 27.9-48.1 mGy) by simulations. The relative differences of organ dose between measurement and simulation were 13%, excluding of breast's 42%. We found that organ dose by simulation was lower than by measurement. In conclusion, the results of relative differences will be useful for evaluating organ doses for individual patients by simulation software Radimetrics.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Radiometria , Tomografia Computadorizada por Raios X/instrumentação
10.
Artigo em Japonês | MEDLINE | ID: mdl-29353833

RESUMO

Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the feasible index for estimation organ dose in almost organs because it reflected each patient size. The differences of organ dose between estimation and simulation were within 23%. In conclusion, our estimation method of organ dose using indices of CT dose is convenient for clinical with accuracy.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Sistema de Registros
11.
Artigo em Japonês | MEDLINE | ID: mdl-30033960

RESUMO

PURPOSE: To assess the dose reduction of radiologists by using angular beam modulation (ABM) and radiation protection drape during computed tomography (CT) fluoroscopy. MATERIALS AND METHODS: The phantom was set on the lower that is 15 cm from the isocenter position. We measured the radiation exposure around the phantom with radiophotoluminescence glass dosimeters. The space radiation dose rate was measured with an ionization chamber dosimeter in the CT room. RESULTS: The dose rate of finger radiation exposure was 67% at assumed assist tool position with ABM. And the dose rate of finger radiation exposure with the combination of ABM and radiation protection drape was 33%. The space dose rate of exposure with the combination of ABM and radiation protection drape was 49% at 150 cm. CONCLUSION: The combination of ABM and radiation protection drape can reduce finger radiation exposure at assumed assist tool position. The space dose rate of the standing position of radiologists can get a clear dose of radiation reduction by the combination of both.


Assuntos
Proteção Radiológica , Radiologistas , Tomografia Computadorizada por Raios X , Fluoroscopia , Humanos , Imagens de Fantasmas , Doses de Radiação
12.
Environ Sci Technol ; 51(22): 13086-13094, 2017 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-29111691

RESUMO

Importance of end-of-life vehicles (ELVs) as an urban mine is expected to grow, as more people in developing countries are experiencing increased standards of living, while the automobiles are increasingly made using high-quality materials to meet stricter environmental and safety requirements. While most materials in ELVs, particularly steel, have been recycled at high rates, quality issues have not been adequately addressed due to the complex use of automobile materials, leading to considerable losses of valuable alloying elements. This study highlights the maximal potential of quality-oriented recycling of ELV steel, by exploring the utilization methods of scrap, sorted by parts, to produce electric-arc-furnace-based crude alloy steel with minimal losses of alloying elements. Using linear programming on the case of Japanese economy in 2005, we found that adoption of parts-based scrap sorting could result in the recovery of around 94-98% of the alloying elements occurring in parts scrap (manganese, chromium, nickel, and molybdenum), which may replace 10% of the virgin sources in electric arc furnace-based crude alloy steel production.


Assuntos
Programação Linear , Reciclagem , Aço , Ligas , Humanos , Japão
13.
Artigo em Japonês | MEDLINE | ID: mdl-28111394

RESUMO

Diffusion kurtosis imaging (DKI) is a method of analyzing restricted diffusion. Mean kurtosis (MK) is obtained from DKI. It is not known how different MRI scanners and coil systems will change MK when the same imaging parameters are used. The purpose of this study is to identify tendencies in MK when using various MRI scanners and coil systems. A total of 27 healthy volunteers were enrolled in this study. DKI was performed on the brain for each volunteer on five MRI scanner/coil system combinations using the same scan parameters. MK of 10 anatomical areas of the brain were compared, and the signal-noise ratios (SNRs) of b-2000 s/mm2 images were measured in identical areas. There were no significant differences among MKs from multi transmit (MT) MRI systems, but MK was significantly lower on the single transmit MRI system because of pepper artifact caused by low SNR. In conclusion, we found no significant differences in MK among MT systems, and MK was significantly lower without MT.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Adulto , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tecnologia Radiológica/instrumentação , Tecnologia Radiológica/métodos , Adulto Jovem
14.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 73(12): 1224-1230, 2017.
Artigo em Japonês | MEDLINE | ID: mdl-29269617

RESUMO

The purpose of this study was to reveal the optimal function for regression of spectral Hounsfield Unit (HU) curves. The optimization procedure consists of the following steps: 1) obtaining dual energy CT (DECT) images of the RMI 467 phantom, 2) obtaining virtual monochromatic images from DECT images, 3) mapping each region of interest (ROI) to a phantom rod on virtual monochromatic images, 4) obtaining spectral HU curves for all rods, 5) regression of spectral HU curves using various functions, including linear, quadratic polynomial, cubic polynomial, quartic polynomial, quintic polynomial, sextic polynomial, septic polynomial, exponential, corrected exponential, bi-exponential, and logarithm, and 6) calculating the coefficients and the Akaike Information Criterion (AIC) of the functions listed above. Results indicated that the quintic polynomial function is suitable for analyzing the regression of spectral HU curves. The coefficients generated by the quartic or higher order polynomial functions were significantly higher than those generated by other functions (p<0.05). The median AIC of the quintic polynomial was the lowest among all functions. Therefore, we conclude that the quintic polynomial is the best function to use for the regression of spectral HU curves.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
15.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 72(12): 1230-1236, 2016.
Artigo em Japonês | MEDLINE | ID: mdl-28003610

RESUMO

PURPOSE: The contrast agent used in the diagnostic department has high atomic numbers and might influence dose deposition in the particle therapy. In particular, the influence of gadolinium-based (Gd) contrast agent on range in carbon ion radiotherapy has not yet been evaluated. For this reason, we avoid carbon treatment and planning computed tomography (CT) acquisition on days when the contrast-enhanced magnetic resonance image (MRI) is performed. In this study, we evaluated the time required for this beam range effect to vanish by evaluating the temporal changes in the CT values after an enhanced MRI as well as the stopping power of Gd solution. MATERIALS AND METHODS: Two types of diluted solutions with Gd contrast agent were used for comparing their transferred stopping power (TSP) and measured stopping power (MSP). The TSP was calculated with a CT value to stopping power ratio table that was created previously. Additionally, to evaluate in vivo attenuation, we measured the CT values in the renal pelvis from the CT images with and without contrast agent for 73 patients. RESULTS: The maximum difference between the TSP and MSP was 85%. The difference between the TSP after 4 hours and the TSP with non-enhanced cases was less than 1%. Moreover, the difference between the MSP after 1 hour and the MSP with non-enhanced cases was less than 0.1%. CONCLUSION: It was found that the impact of Gd contrast agent can be neglected 1 hour after administration for carbon beam irradiation and 4 hours after for planning the CT image acquisition.


Assuntos
Radioterapia com Íons Pesados/instrumentação , Radioterapia com Íons Pesados/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Isótopos de Carbono , Meios de Contraste , Feminino , Gadolínio , Humanos , Aumento da Imagem , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
16.
Nucl Med Commun ; 45(5): 406-411, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38372047

RESUMO

OBJECTIVES: Lower gingival squamous cell carcinoma (LGSCC) has the potential to invade the alveolar bone. Traditionally, the diagnosis of LGSCC relied on morphological imaging, but inconsistencies between these assessments and surgical findings have been observed. This study aimed to assess the correlation between LGSCC bone marrow invasion and PET texture features and to enhance diagnostic accuracy by using machine learning. METHODS: A retrospective analysis of 159 LGSCC patients with pretreatment 18 F-fluorodeoxyglucose (FDG) PET/computed tomography (CT) examination from 2009 to 2017 was performed. We extracted radiomic features from the PET images, focusing on pathologic bone marrow invasion detection. Extracted features underwent the least absolute shrinkage and selection operator algorithm-based selection and were then used for machine learning via the XGBoost package to distinguish bone marrow invasion presence. Receiver operating characteristic curve analysis was performed. RESULTS: From the 159 patients, 88 qualified for further analysis (59 men; average age, 69.2 years), and pathologic bone marrow invasion was identified in 69 (78%) of these patients. Three significant radiological features were identified: Gray level co-occurrence matrix_Correlation, INTENSITY-BASED_IntensityInterquartileRange, and MORPHOLOGICAL_SurfaceToVolumeRatio. An XGBoost machine-learning model, using PET radiomic features to detect bone marrow invasion, yielded an area under the curve value of 0.83. CONCLUSION: Our findings highlighted the potential of 18 F-FDG PET radiomic features, combined with machine learning, as a promising avenue for improving LGSCC diagnosis and treatment. Using 18 F-FDG PET texture features may provide a robust and accurate method for determining the presence or absence of bone marrow invasion in LGSCC patients.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Masculino , Humanos , Idoso , Fluordesoxiglucose F18 , Medula Óssea/diagnóstico por imagem , Medula Óssea/patologia , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Aprendizado de Máquina , Neoplasias de Cabeça e Pescoço/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
17.
Eur J Radiol ; 176: 111504, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38761445

RESUMO

PURPOSE: To identify gadolinium-based contrast agents (GBCAs)-related and patient-related risk factors for acute adverse reactions (AARs), and to examine the incidence and severity of repeated AARs. METHODS: This study retrospectively evaluated all intravenous GBCA injections in MRI studies at a single institution from January 2012 to September 2019. First-time AARs in patients without a past history of AARs and risk factors were assessed using multivariable regression models with generalized estimating equations. For patients with a past history of AAR(s), we evaluated the incidence of repeated AARs using the Fisher's exact test, as well as the severity of these repeated AARs. RESULTS: First-time AARs occurred in 129 of 41,827 GBCA injections (0.31 %; 0.70 % of 18,431 patients). With gadoterate meglumine as the reference, the odds ratio (OR) for allergic-like reactions to three GBCAs ranged from 3.27 to 8.03 (p = 0.012 to <0.001). For chemotoxic reactions, the OR was 3.75 (p = 0.001) for gadoteridol. Outpatients had a lower OR for chemotoxic reactions, while higher ORs were observed in head/neck and breast MRI (p < 0.05). The OR for age was 0.99 (p < 0.05). Patients with a past history of AAR(s) had a 3.6 % incidence of mild repeated AARs for all GBCA, significantly higher than the 0.31 % in first-time AARs (p < 0.001). No effectiveness was found for steroid premedication. CONCLUSION: The occurrence of first-time AARs was related to the GBCA used and other factors. The incidence of repeated AARs was higher than first-time AARs, though all were mild in severity.


Assuntos
Meios de Contraste , Gadolínio , Imageamento por Ressonância Magnética , Humanos , Meios de Contraste/efeitos adversos , Feminino , Estudos Retrospectivos , Masculino , Imageamento por Ressonância Magnética/métodos , Gadolínio/efeitos adversos , Pessoa de Meia-Idade , Fatores de Risco , Idoso , Adulto , Incidência , Compostos Organometálicos/efeitos adversos , Idoso de 80 Anos ou mais
18.
Jpn J Radiol ; 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795287

RESUMO

PURPOSE: Dialysis patients are at an increased risk of developing renal cell carcinoma (RCC); however, differentiating between RCC and benign cysts can sometimes be difficult using modalities, such as computed tomography (CT) and ultrasonography. 18F-Fluorodeoxyglucose positron emission tomography (FDG-PET)/CT efficiently detects malignant tumors; however, physiological accumulation of FDG in the kidney limits its efficacy in detecting renal tumors. However, in patients with severely impaired renal function, the renal accumulation of FDG is decreased, possibly improving the detection of renal malignancies in this patient population. This study evaluated the usefulness of FDG-PET/CT as a screening tool for detecting RCC in patients with end-stage renal disease. MATERIALS AND METHODS: This prospective study recruited 150 participants from 2012 to 2016 who were on dialysis or underwent renal transplantation and were on dialysis until transplantation. FDG-PET/CT was performed to screen for RCC. Three radiologists independently evaluated the images. No protocol was defined for the additional management of positive examinations, leaving decisions to the discretion of each participant. Negative examinations were observed until the end of 2019. RESULTS: In total, 150 participants (mean age, 58 ± 13 years; 105 men) underwent FDG-PET/CT. Twenty patients (13.4%) were diagnosed as positive. Fifteen patients underwent additional examinations and/or procedures, and RCC was found in seven patients. Of the four patients who underwent surgical resection, the pathological results were clear cell RCC in one, papillary RCC in one, and acquired cystic disease-associated RCC in two. Two participants were diagnosed with RCC on bone biopsy, and one was diagnosed on dynamic CT but opted for observation. The sensitivity, specificity, and negative predictive value were 100%, 93.9%, and 100%, respectively. CONCLUSION: FDG-PET/CT was useful for detecting RCC in patients with end-stage renal disease. Our findings show the potential use of FDG-PET/CT as a screening tool for RCC in this patient population.

19.
Jpn J Radiol ; 41(9): 1022-1028, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37040026

RESUMO

PURPOSE: To analyze the appropriateness of primary response for anaphylaxis due to iodinated contrast media (ICM) or gadolinium-based contrast agents (GBCA). MATERIALS AND METHODS: This retrospective study included all patients in whom intravenous contrast agents (five types of ICMs and four types of GBCAs) were administered at our hospital between April 2016 and September 2021. For the patients who developed anaphylaxis, we obtained data on the time records of contrast injection, anaphylaxis onset, and intramuscular adrenaline (epinephrine) administration. RESULTS: Of the 76,555 ICM and 30,731 GBCA administrations, anaphylaxis occurred in 49 cases (0.05%), and in 48 cases (98.0%) the onset was within 30 min after administration with widely distributed times (median, 7.5 min; interquartile range, 4.5-10.8 min; max, 26 min). Intramuscular adrenaline administration was performed in 43 cases (87.8%), and this was done within five minutes after the onset in 37 cases (75.5%). Only in 24 cases (49.0%), there were time records of both the onset and adrenaline administration (if performed). CONCLUSION: Anaphylaxis occurred within 30 min after contrast injection in the majority of the cases, but times were widely distributed. Only in 75.5% of cases, appropriate primary treatment was performed, and the importance of keeping exact time records in patients' charts should be re-emphasized.


Assuntos
Anafilaxia , Humanos , Anafilaxia/induzido quimicamente , Estudos Retrospectivos , Meios de Contraste/efeitos adversos , Epinefrina/uso terapêutico , Epinefrina/efeitos adversos
20.
Eur J Radiol ; 164: 110880, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37187078

RESUMO

PURPOSE: To evaluate the clinical features and risk factors of iodinated contrast media (ICM)-induced anaphylaxis. METHODS: This retrospective study included all patients undergoing contrast-enhanced computed tomography (CT) with intravenous ICM administration (iopamidol, iohexol, iomeprol, iopromide, ioversol) at our hospital between April 2016 and September 2021. Medical records of patients who experienced anaphylaxis were reviewed, and the multivariable regression model using generalized estimating equations was employed to eliminate the effect of intrapatient correlation. RESULTS: Of the 76,194 ICM administrations (44,099 men [58 %] and 32,095 women; age, median, 68 years) to 27, 696 patients, anaphylaxis occurred in 45 cases in 45 different patients (0.06 % of administration and 0.16 % of patients), all with onset within 30 min after administration. Thirty-one (69 %) had no risk factors for ADRs, including 14 (31 %) who had previously used the same ICM that caused anaphylaxis. Thirty-one patients (69 %) had a history of ICM use without any ADRs. Four patients (8.9 %) received oral steroid premedication. The only factor associated with anaphylaxis was the type of ICM, with an odds ratio (OR) of 6.8 (p < 0.001) for iomeprol with iopamidol as a reference. No significant differences in OR of anaphylaxis were found for patients' age, sex, or premedication. CONCLUSION: The overall incidence of anaphylaxis due to ICM was very low. More than half of the cases had no risk factors for ADRs and had no ADRs on past ICM administration, although the ICM type was associated with a higher OR.


Assuntos
Anafilaxia , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Masculino , Humanos , Feminino , Idoso , Meios de Contraste/efeitos adversos , Iopamidol/efeitos adversos , Anafilaxia/induzido quimicamente , Anafilaxia/epidemiologia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA