Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
J Clin Microbiol ; : e0078624, 2024 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-39445833

RESUMO

Non-sputum tests are needed to improve tuberculosis (TB) diagnosis and close the diagnostic gap. The World Health Organization's target product profile (TPP) for point-of-care (POC) screening tests requires a minimum sensitivity of 90% and a specificity of 70%. Our objective was to identify host blood protein biomarkers meeting TPP criteria. A systematic review was conducted and reported following PRISMA guidelines. Data extraction and quality assessment with Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) were completed for the included studies. Heterogeneity was assessed. For biomarkers reporting sensitivity and specificity in at least four studies, a random-effects meta-analysis was performed for biomarkers with similar cut-offs. We screened 4,651 citations and included 65 studies that enrolled 16,010 participants and evaluated 156 host proteins. Most (47/65) studies enrolled adult pulmonary TB (PTB), with 15 studies in adult extra-pulmonary TB and 5 in children. Small early-stage discovery studies with case-control design were common (24/65) and had a high risk of bias. For adult PTB, CRP, IP-10, NCAM-1, and SAA met TPP criteria in high-quality studies. There was a high degree of heterogeneity in biomarker cut-offs and study design. CRP at 10 mg/L cut-off was meta-analyzed from 10 studies; pooled sensitivity 86% [95% confidence interval (CI): 80-95] and pooled specificity 67% (95% CI: 54-79). In people living with HIV (six studies), CRP pooled sensitivity was 93% (95% CI: 90-95), and pooled specificity was 59% (95% CI: 40-78). We identified promising biomarkers that performed well in high-quality studies. Data overall are limited and highly heterogenous. Further standardized validation across subgroups in prospective studies is needed before translating into POC assays. IMPORTANCE: To our knowledge, this is the first comprehensive systematic review of host blood protein biomarkers for tuberculosis (TB), and we identified promising biomarkers for a TB screening test.

2.
Virol J ; 21(1): 99, 2024 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-38685117

RESUMO

BACKGROUND: During the COVID-19 pandemic, antigen diagnostic tests were frequently used for screening, triage, and diagnosis. Novel instrument-based antigen tests (iAg tests) hold the promise of outperforming their instrument-free, visually-read counterparts. Here, we provide a systematic review and meta-analysis of the SARS-CoV-2 iAg tests' clinical accuracy. METHODS: We systematically searched MEDLINE (via PubMed), Web of Science, medRxiv, and bioRxiv for articles published before November 7th, 2022, evaluating the accuracy of iAg tests for SARS-CoV-2 detection. We performed a random effects meta-analysis to estimate sensitivity and specificity and used the QUADAS-2 tool to assess study quality and risk of bias. Sub-group analysis was conducted based on Ct value range, IFU-conformity, age, symptom presence and duration, and the variant of concern. RESULTS: We screened the titles and abstracts of 20,431 articles and included 114 publications that fulfilled the inclusion criteria. Additionally, we incorporated three articles sourced from the FIND website, totaling 117 studies encompassing 95,181 individuals, which evaluated the clinical accuracy of 24 commercial COVID-19 iAg tests. The studies varied in risk of bias but showed high applicability. Of 24 iAg tests from 99 studies assessed in the meta-analysis, the pooled sensitivity and specificity compared to molecular testing of a paired NP swab sample were 76.7% (95% CI 73.5 to 79.7) and 98.4% (95% CI 98.0 to 98.7), respectively. Higher sensitivity was noted in individuals with high viral load (99.6% [95% CI 96.8 to 100] at Ct-level ≤ 20) and within the first week of symptom onset (84.6% [95% CI 78.2 to 89.3]), but did not differ between tests conducted as per manufacturer's instructions and those conducted differently, or between point-of-care and lab-based testing. CONCLUSION: Overall, iAg tests have a high pooled specificity but a moderate pooled sensitivity, according to our analysis. The pooled sensitivity increases with lower Ct-values (a proxy for viral load), or within the first week of symptom onset, enabling reliable identification of most COVID-19 cases and highlighting the importance of context in test selection. The study underscores the need for careful evaluation considering performance variations and operational features of iAg tests.


Assuntos
Antígenos Virais , Teste Sorológico para COVID-19 , COVID-19 , SARS-CoV-2 , Sensibilidade e Especificidade , Humanos , COVID-19/diagnóstico , COVID-19/virologia , SARS-CoV-2/imunologia , Teste Sorológico para COVID-19/métodos , Antígenos Virais/imunologia , Antígenos Virais/análise , Teste para COVID-19/métodos
3.
PLoS Med ; 19(5): e1004011, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35617375

RESUMO

BACKGROUND: Comprehensive information about the accuracy of antigen rapid diagnostic tests (Ag-RDTs) for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is essential to guide public health decision makers in choosing the best tests and testing policies. In August 2021, we published a systematic review and meta-analysis about the accuracy of Ag-RDTs. We now update this work and analyze the factors influencing test sensitivity in further detail. METHODS AND FINDINGS: We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched preprint and peer-reviewed databases for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 until August 31, 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity with reverse transcription polymerase chain reaction (RT-PCR) testing as a reference. To evaluate factors influencing test sensitivity, we performed 3 different analyses using multivariable mixed-effects meta-regression models. We included 194 studies with 221,878 Ag-RDTs performed. Overall, the pooled estimates of Ag-RDT sensitivity and specificity were 72.0% (95% confidence interval [CI] 69.8 to 74.2) and 98.9% (95% CI 98.6 to 99.1). When manufacturer instructions were followed, sensitivity increased to 76.3% (95% CI 73.7 to 78.7). Sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values (97.9% [95% CI 96.9 to 98.9] and 90.6% [95% CI 88.3 to 93.0] for Ct-values <20 and <25, compared to 54.4% [95% CI 47.3 to 61.5] and 18.7% [95% CI 13.9 to 23.4] for Ct-values ≥25 and ≥30) and was estimated to increase by 2.9 percentage points (95% CI 1.7 to 4.0) for every unit decrease in mean Ct-value when adjusting for testing procedure and patients' symptom status. Concordantly, we found the mean Ct-value to be lower for true positive (22.2 [95% CI 21.5 to 22.8]) compared to false negative (30.4 [95% CI 29.7 to 31.1]) results. Testing in the first week from symptom onset resulted in substantially higher sensitivity (81.9% [95% CI 77.7 to 85.5]) compared to testing after 1 week (51.8%, 95% CI 41.5 to 61.9). Similarly, sensitivity was higher in symptomatic (76.2% [95% CI 73.3 to 78.9]) compared to asymptomatic (56.8% [95% CI 50.9 to 62.4]) persons. However, both effects were mainly driven by the Ct-value of the sample. With regards to sample type, highest sensitivity was found for nasopharyngeal (NP) and combined NP/oropharyngeal samples (70.8% [95% CI 68.3 to 73.2]), as well as in anterior nasal/mid-turbinate samples (77.3% [95% CI 73.0 to 81.0]). Our analysis was limited by the included studies' heterogeneity in viral load assessment and sample origination. CONCLUSIONS: Ag-RDTs detect most of the individuals infected with SARS-CoV-2, and almost all (>90%) when high viral loads are present. With viral load, as estimated by Ct-value, being the most influential factor on their sensitivity, they are especially useful to detect persons with high viral load who are most likely to transmit the virus. To further quantify the effects of other factors influencing test sensitivity, standardization of clinical accuracy studies and access to patient level Ct-values and duration of symptoms are needed.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade
4.
Liver Int ; 42(3): 532-540, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34817928

RESUMO

BACKGROUND AND AIMS: India has a significant burden of hepatitis C virus (HCV) infection and has committed to achieving national elimination by 2030. This will require a substantial scale-up in testing and treatment. The "HEAD-Start Project Delhi" aimed to enhance HCV diagnosis and treatment pathways among the general population. METHODS: A prospective study was conducted at 5 district hospitals (Arm 1: one-stop shop), 15 polyclinics (Arm 2: referral for viral load (VL) testing and treatment) and 62 screening camps (Arm 3: referral for treatment). HCV prevalence, retention in the HCV care cascade, and turn-around time were measured. RESULTS: Between January and September 2019, 37 425 participants were screened for HCV. The median (IQR) age of participants was 35 (26-48) years, with 50.4% male and 49.6% female. A significantly higher proportion of participants in Arm 1 (93.7%) and Arm 3 (90.3%) received a VL test compared with Arm 2 (52.5%, P < .001). Of those confirmed positive, treatment was initiated at significantly higher rates for participants in both Arms 1 (85.6%) and 2 (73.7%) compared to Arm 3 (41.8%, P < .001). Arm 1 was found to be a cost-saving strategy compared to Arm 2, Arm 3, and no action. CONCLUSIONS: Delivery of all services at a single site (district hospitals) resulted in a higher yield of HCV seropositive cases and retention compared with sites where participants were referred elsewhere for VL testing and/or treatment. The highest level of retention in the care cascade was also associated with the shortest turn-around times.


Assuntos
Hepacivirus , Hepatite C , Adulto , Estudos de Viabilidade , Feminino , Hepatite C/diagnóstico , Hepatite C/epidemiologia , Hepatite C/terapia , Humanos , Índia/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
Infection ; 50(2): 395-406, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34383260

RESUMO

PURPOSE: Rapid antigen-detecting tests (Ag-RDTs) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can transform pandemic control. Thus far, sensitivity (≤ 85%) of lateral-flow assays has limited scale-up. Conceivably, microfluidic immunofluorescence Ag-RDTs could increase sensitivity for SARS-CoV-2 detection. METHODS: This multi-centre diagnostic accuracy study investigated performance of the microfluidic immunofluorescence LumiraDx™ assay, enrolling symptomatic and asymptomatic participants with suspected SARS-CoV-2 infection. Participants collected a supervised nasal mid-turbinate (NMT) self-swab for Ag-RDT testing, in addition to a professionally collected nasopharyngeal (NP) swab for routine testing with reverse transcriptase polymerase chain reaction (RT-PCR). Results were compared to calculate sensitivity and specificity. Sub-analyses investigated the results by viral load, symptom presence and duration. An analytical study assessed exclusivity and limit-of-detection (LOD). In addition, we evaluated ease-of-use. RESULTS: The study was conducted between November 2nd 2020 and 4th of December 2020. 761 participants were enrolled, with 486 participants reporting symptoms on testing day. 120 out of 146 RT-PCR positive cases were detected positive by LumiraDx™, resulting in a sensitivity of 82.2% (95% CI 75.2-87.5%). Specificity was 99.3% (CI 98.3-99.7%). Sensitivity was increased in individuals with viral load ≥ 7 log10 SARS-CoV2 RNA copies/ml (93.8%; CI 86.2-97.3%). Testing against common respiratory commensals and pathogens showed no cross-reactivity and LOD was estimated to be 2-56 PFU/mL. The ease-of-use-assessment was favourable for lower throughput settings. CONCLUSION: The LumiraDx™ assay showed excellent analytical sensitivity, exclusivity and clinical specificity with good clinical sensitivity using supervised NMT self-sampling. TRIAL REGISTRATION NUMBER AND REGISTRATION DATE: DRKS00021220 and 01.04.2020.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Pandemias , Sistemas Automatizados de Assistência Junto ao Leito , RNA Viral , Sensibilidade e Especificidade
6.
PLoS Med ; 18(8): e1003735, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34383750

RESUMO

BACKGROUND: SARS-CoV-2 antigen rapid diagnostic tests (Ag-RDTs) are increasingly being integrated in testing strategies around the world. Studies of the Ag-RDTs have shown variable performance. In this systematic review and meta-analysis, we assessed the clinical accuracy (sensitivity and specificity) of commercially available Ag-RDTs. METHODS AND FINDINGS: We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched multiple databases (PubMed, Web of Science Core Collection, medRvix, bioRvix, and FIND) for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 up until 30 April 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity in comparison to reverse transcription polymerase chain reaction (RT-PCR) testing. We assessed heterogeneity by subgroup analyses, and rated study quality and risk of bias using the QUADAS-2 assessment tool. From a total of 14,254 articles, we included 133 analytical and clinical studies resulting in 214 clinical accuracy datasets with 112,323 samples. Across all meta-analyzed samples, the pooled Ag-RDT sensitivity and specificity were 71.2% (95% CI 68.2% to 74.0%) and 98.9% (95% CI 98.6% to 99.1%), respectively. Sensitivity increased to 76.3% (95% CI 73.1% to 79.2%) if analysis was restricted to studies that followed the Ag-RDT manufacturers' instructions. LumiraDx showed the highest sensitivity, with 88.2% (95% CI 59.0% to 97.5%). Of instrument-free Ag-RDTs, Standard Q nasal performed best, with 80.2% sensitivity (95% CI 70.3% to 87.4%). Across all Ag-RDTs, sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values, i.e., <20 (96.5%, 95% CI 92.6% to 98.4%) and <25 (95.8%, 95% CI 92.3% to 97.8%), in comparison to those with Ct ≥ 25 (50.7%, 95% CI 35.6% to 65.8%) and ≥30 (20.9%, 95% CI 12.5% to 32.8%). Testing in the first week from symptom onset resulted in substantially higher sensitivity (83.8%, 95% CI 76.3% to 89.2%) compared to testing after 1 week (61.5%, 95% CI 52.2% to 70.0%). The best Ag-RDT sensitivity was found with anterior nasal sampling (75.5%, 95% CI 70.4% to 79.9%), in comparison to other sample types (e.g., nasopharyngeal, 71.6%, 95% CI 68.1% to 74.9%), although CIs were overlapping. Concerns of bias were raised across all datasets, and financial support from the manufacturer was reported in 24.1% of datasets. Our analysis was limited by the included studies' heterogeneity in design and reporting. CONCLUSIONS: In this study we found that Ag-RDTs detect the vast majority of SARS-CoV-2-infected persons within the first week of symptom onset and those with high viral load. Thus, they can have high utility for diagnostic purposes in the early phase of disease, making them a valuable tool to fight the spread of SARS-CoV-2. Standardization in conduct and reporting of clinical accuracy studies would improve comparability and use of data.


Assuntos
Teste Sorológico para COVID-19/métodos , Fatores Etários , Antígenos Virais/análise , COVID-19/diagnóstico , COVID-19/etiologia , Teste Sorológico para COVID-19/normas , Portador Sadio/diagnóstico , Portador Sadio/virologia , Humanos , Nasofaringe/virologia , Kit de Reagentes para Diagnóstico , Padrões de Referência , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Carga Viral
7.
Med Microbiol Immunol ; 210(4): 181-186, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34028625

RESUMO

In 2020, the World Health Organization (WHO) recommended two SARS-CoV-2 lateral flow antigen-detecting rapid diagnostics tests (Ag-RDTs), both initially with nasopharyngeal (NP) sample collection. Independent head-to-head studies are necessary for SARS-CoV-2 Ag-RDT nasal sampling to demonstrate comparability of performance with nasopharyngeal (NP) sampling. We conducted a head-to-head comparison study of a supervised, self-collected nasal mid-turbinate (NMT) swab and a professional-collected NP swab, using the Panbio™ Ag-RDT (distributed by Abbott). We calculated positive and negative percent agreement between the sampling methods as well as sensitivity and specificity for both sampling techniques compared to the reference standard reverse transcription polymerase chain reaction (RT-PCR). A SARS-CoV-2 infection could be diagnosed by RT-PCR in 45 of 290 participants (15.5%). Comparing the NMT and NP sampling the positive percent agreement of the Ag-RDT was 88.1% (37/42 PCR positives detected; CI 75.0-94.8%). The negative percent agreement was 98.8% (245/248; CI 96.5-99.6%). The overall sensitivity of Panbio with NMT sampling was 84.4% (38/45; CI 71.2-92.3%) and 88.9% (40/45; CI 76.5-95.5%) with NP sampling. Specificity was 99.2% (243/245; CI 97.1-99.8%) for both, NP and NMT sampling. The sensitivity of the Panbio test in participants with high viral load (> 7 log10 SARS-CoV-2 RNA copies/mL) was 96.3% (CI 81.7-99.8%) for both, NMT and NP sampling. For the Panbio supervised NMT self-sampling yields comparable results to NP sampling. This suggests that nasal self-sampling could be used for to enable scaled-up population testing.Clinical Trial DRKS00021220.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/isolamento & purificação , Manejo de Espécimes/métodos , Adulto , Antígenos Virais , COVID-19/imunologia , Teste de Ácido Nucleico para COVID-19 , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nasofaringe/virologia , RNA Viral , Sensibilidade e Especificidade , Carga Viral , Organização Mundial da Saúde
8.
Eur Respir J ; 51(1)2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29348181

RESUMO

Household contacts of pulmonary tuberculosis (TB) patients are at increased risk of TB infection and disease. However, their risk in relation to the intensity of exposure remains unknown.We studied smear-positive TB cases and their household contacts in Vitória, Brazil. We collected clinical, demographic and radiographic information from TB cases, and obtained tuberculin skin test (TST) and QuantiFERON-TB Gold (QFT) results from household contacts. We measured intensity of exposure using a proximity score and sleep location in relation to the TB index case and defined infection by TST ≥10 mm or QFT ≥0.35 UI·mL-1 We ascertained secondary TB cases by reviewing local and nationwide case registries.We included 160 TB index cases and 894 household contacts. 464 (65%) had TB infection and 23 (2.6%) developed TB disease. Risk of TB infection and disease increased with more intense exposures. In an adjusted analysis, the proximity score was associated with TB disease (OR 1.61, 95% CI 1.25-2.08; p<0.000); however, its diagnostic performance was only moderate.Intensity of exposure increased risk of TB infection and disease among household contacts; however, its diagnostic performance was still suboptimal. A biomarker to target preventive therapy is urgently needed in this at-risk population.


Assuntos
Busca de Comunicante/métodos , Tuberculose Pulmonar/transmissão , Adulto , Área Sob a Curva , Biomarcadores/metabolismo , Brasil , Controle de Doenças Transmissíveis , Características da Família , Feminino , Humanos , Infectologia/métodos , Testes de Liberação de Interferon-gama , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis , Curva ROC , Risco , Teste Tuberculínico/métodos , Tuberculose Pulmonar/epidemiologia
9.
Stat Med ; 36(16): 2522-2532, 2017 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-28370491

RESUMO

Household contact studies, a mainstay of tuberculosis transmission research, often assume that tuberculosis-infected household contacts of an index case were infected within the household. However, strain genotyping has provided evidence against this assumption. Understanding the household versus community infection dynamic is essential for designing interventions. The misattribution of infection sources can also bias household transmission predictor estimates. We present a household-community transmission model that estimates the probability of community infection, that is, the probability that a household contact of an index case was actually infected from a source outside the home and simultaneously estimates transmission predictors. We show through simulation that our method accurately predicts the probability of community infection in several scenarios and that not accounting for community-acquired infection in household contact studies can bias risk factor estimates. Applying the model to data from Vitória, Brazil, produced household risk factor estimates similar to two other standard methods for age and sex. However, our model gave different estimates for sleeping proximity to index case and disease severity score. These results show that estimating both the probability of community infection and household transmission predictors is feasible and that standard tuberculosis transmission models likely underestimate the risk for two important transmission predictors. Copyright © 2017 John Wiley & Sons, Ltd.


Assuntos
Teorema de Bayes , Modelos Lineares , Tuberculose Pulmonar/transmissão , Bioestatística , Brasil/epidemiologia , Infecções Comunitárias Adquiridas/epidemiologia , Infecções Comunitárias Adquiridas/transmissão , Simulação por Computador , Busca de Comunicante/estatística & dados numéricos , Características da Família , Humanos , Probabilidade , Fatores de Risco , Tuberculose Pulmonar/epidemiologia
10.
BMC Infect Dis ; 17(1): 576, 2017 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-28821234

RESUMO

BACKGROUND: In household contact investigations of tuberculosis (TB), a second tuberculin skin test (TST) obtained several weeks after a first negative result consistently identifies individuals that undergo TST conversion. It remains unclear whether this delay in M. tuberculosis infection is related to differences in the infectious exposure, TST boosting, partial host resistance, or some other factor. METHODS: We conducted a household contact study Vitória, Brazil. Between 2008 and 2013, we identified culture-positive pulmonary TB patients and evaluated their household contacts with both a TST and interferon gamma release assay (IGRA), and identified TST converters at 8-12 weeks post study enrollment. Contacts were classified as TST-positive (≥10 mm) at baseline, TST converters, or persistently TST-negative. We compared TST converters to TST-positive and to TST-negative contacts separately, using generalized estimating equations. RESULTS: We enrolled 160 index patients and 838 contacts; 523 (62.4%) were TST+, 62 (7.4%) TST converters, and 253 (30.2%) TST-. TST converters were frequently IGRA- at 8-12 weeks. In adjusted analyses, characteristics distinguishing TST converters from TST+ contacts (no contact with another TB patient and residence ownership) were different than those differentiating them from TST- contacts (stronger cough in index patient and contact BCG scar). CONCLUSIONS: The individual risk and timing of M. tuberculosis infection within households is variable and dependent on index patient, contact and environmental factors within the household, and the surrounding community. Our findings suggest a threshold effect in the risk of infection in humans.


Assuntos
Tuberculose/diagnóstico , Tuberculose/epidemiologia , Adolescente , Adulto , Brasil/epidemiologia , Criança , Tosse/microbiologia , Características da Família , Feminino , Humanos , Testes de Liberação de Interferon-gama , Masculino , Mycobacterium tuberculosis/patogenicidade , Teste Tuberculínico , Tuberculose/transmissão , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/epidemiologia , Adulto Jovem
11.
Clin Infect Dis ; 63(1): 10-20, 2016 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-27025837

RESUMO

BACKGROUND: Tuberculosis disease develops in only 5%-10% of humans infected with Mycobacterium tuberculosis The mechanisms underlying this variability remain poorly understood. We recently demonstrated that colony-forming units of M. tuberculosis in cough-generated aerosols are a better predictor of infection than the standard sputum acid-fast bacilli smear. We hypothesized that cough aerosol cultures may also predict progression to tuberculosis disease in contacts. METHODS: We conducted a retrospective cohort study of 85 patients with smear-positive tuberculosis and their 369 household contacts in Kampala, Uganda. Index case patients underwent a standard evaluation, and we cultured M. tuberculosis from cough aerosols. Contacts underwent a standard evaluation at enrollment, and they were later traced to determine their tuberculosis status. RESULTS: During a median follow-up of 3.9 years, 8 (2%) of the contacts developed tuberculosis disease. In unadjusted and adjusted analyses, incident tuberculosis disease in contacts was associated with sputum Mycobacterial Growth Indicator Tube culture (odds ratio, 8.2; 95% confidence interval, 1.1-59.2; P = .04), exposure to a high-aerosol tuberculosis case patient (6.0, 1.4-25.2; P = .01), and marginally, human immunodeficiency virus in the contact (6.11; 0.89-41.7; P = .07). We present data demonstrating that sputum and aerosol specimens measure 2 related but different phenomena. CONCLUSIONS: We found an increased risk of tuberculosis progression among contacts of high-aerosol case patients. The hypothesis that a larger infectious inoculum, represented by high aerosol production, determines the risk of disease progression deserves evaluation in future prospective studies.


Assuntos
Tosse/microbiologia , Mycobacterium tuberculosis , Tuberculose/epidemiologia , Tuberculose/transmissão , Adolescente , Adulto , Aerossóis , Criança , Características da Família , Feminino , Humanos , Masculino , Estudos Retrospectivos , Tuberculose/microbiologia , Uganda/epidemiologia , Adulto Jovem
14.
J Clin Microbiol ; 54(4): 1051-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26865685

RESUMO

The Epistem Genedrive assay rapidly detects the Mycobacterium tuberculosis omplex from sputum and is currently available for clinical use. However, the analytical and clinical performance of this test has not been fully evaluated. The analytical limit of detection (LOD) of the Genedrive PCR amplification was tested with genomic DNA; the performance of the complete (sample processing plus amplification) system was tested by spiking M. tuberculosismc(2)6030 cells into distilled water andM. tuberculosis-negative sputum. Specificity was tested using common respiratory pathogens and nontuberculosis mycobacteria. A clinical evaluation enrolled adults with suspected pulmonary tuberculosis, obtained three sputum samples from each participant, and compared the accuracy of the Gene drive to that of the Xpert MTB/RIF assay using M. tuberculosiscultures as the reference standard. The Genedrive assay had an LOD of 1 pg/µl (100 genomic DNA copies/reaction). The LODs of the system were 2.5 × 10(4)CFU/ml and 2.5 × 10(5)CFU/ml for cells spiked into water and sputum, respectively. False-positiverpoBprobe signals were observed in 3/32 (9.4%) of the negative controls and also in few samples containing Mycobacterium abscessus,Mycobacterium gordonae, o rMycobacterium thermoresistibile In the clinical study, among 336 analyzed participants, the overall sensitivities for the tuberculosis case detection of Gene drive, Xpert, and smear microscopy were 45.4% (95% confidence interval [CI], 35.2% to 55.8%), 91.8% (95% CI, 84.4% to 96.4%), and 77.3% (95% CI, 67.7% to 85.2%), respectively. The sensitivities of Gene drive and Xpert for the detection of smear-microscopy-negative tuberculosis were 0% (95% CI, 0% to 15.4%) and 68.2% (95% CI, 45.1% to 86.1%), respectively. The Genedrive assay did not meet performance standards recommended by the World Health Organization for a smear microscopy replacement tuberculosis test. Epistem is working on modifications to improve the assay.


Assuntos
Técnicas de Diagnóstico Molecular/métodos , Mycobacterium tuberculosis/isolamento & purificação , Tuberculose/diagnóstico , Adulto , Estudos Transversais , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/genética , Sensibilidade e Especificidade , Escarro/microbiologia
15.
J Clin Microbiol ; 52(7): 2513-20, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24808236

RESUMO

Smear microscopy has suboptimal sensitivity, and there is a need to improve its performance since it is commonly used to diagnose tuberculosis (TB). We prospectively evaluated the diagnostic accuracy of the small membrane filtration (SMF) method, an approach that uses a vacuum manifold and is designed to concentrate bacilli onto a filter that can be examined microscopically. We enrolled hospitalized adults suspected to have pulmonary TB in Kampala, Uganda. We obtained a clinical history and three spontaneously expectorated sputum specimens for smear microscopy (direct, concentrated, and SMF), MGIT (mycobacterial growth indicator tube) 960 and Lowenstein-Jensen (LJ) cultures, and Xpert MTB/RIF testing. We performed per-specimen (primary) and per-patient analyses. From October 2012 to June 2013, we enrolled 212 patients (579 sputum specimens). The participants were mostly female (63.2%), and 81.6% were HIV infected; their median CD4 cell count was 47 cells/µl. Overall, 19.0%, 20.4%, 27.1%, 25.2%, and 25.9% of specimens tested positive by direct smear, concentrated smear, MGIT culture, LJ culture, and Xpert test, respectively. In the per-specimen analysis, the sensitivity of the SMF method (48.5%; 95% confidence interval [CI], 37.4 to 59.6) was lower than those of direct smear (60.9%; 51.4 to 70.5 [P = 0.0001]) and concentrated smear (63.3%; 53.6 to 73.1 [P < 0.0001]). Subgroup analyses showed that SMF performed poorly in specimens having a low volume or low bacterial load. The SMF method performed poorly compared to standard smear techniques and was sensitive to sample preparation techniques. The optimal laboratory SMF protocol may require striking a fine balance between sample dilution and filtration failure rate.


Assuntos
Técnicas Bacteriológicas/métodos , Filtração/métodos , Microscopia/métodos , Mycobacterium tuberculosis/isolamento & purificação , Manejo de Espécimes/métodos , Escarro/microbiologia , Tuberculose Pulmonar/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Masculino , Membranas , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Uganda , Adulto Jovem
16.
Clin Infect Dis ; 57(4): 532-42, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23697743

RESUMO

BACKGROUND: The utility of Mycobacterium tuberculosis direct nucleic acid amplification testing (MTD) for pulmonary tuberculosis disease diagnosis in the United States has not been well described. METHODS: We analyzed a retrospective cohort of reported patients with suspected active pulmonary tuberculosis in 2008-2010 from Georgia, Hawaii, Maryland, and Massachusetts to assess MTD use, effectiveness, health-system benefits, and cost-effectiveness. RESULTS: Among 2140 patients in whom pulmonary tuberculosis was suspected, 799 (37%) were M. tuberculosis-culture-positive. Eighty percent (680/848) of patients having acid-fast-bacilli-smear-positive specimens had MTD performed; MTD positive-predictive value (PPV) was 98% and negative-predictive value (NPV) was 94%. Nineteen percent (240/1292) of patients having smear-negative specimens had MTD; MTD PPV was 90% and NPV was 88%. Among patients suspected of tuberculosis but not having MTD, smear PPV for lab-confirmed tuberculosis was 77% and NPV 78%. Compared with no MTD, MTD significantly decreased time to diagnosis in patients with smear-positive/MTD-positive specimens, decreased respiratory isolation for patients having smear-positive/MTD-negative/culture-negative specimens, decreased outpatient days of unnecessary tuberculosis medications, and reduced resources expended on contact investigation. While MTD generally cost more than no MTD, incremental cost savings occurred in patients with human immunodeficiency virus (HIV) or homelessness to diagnose or to exclude tuberculosis, and in patients with substance abuse having smear-negative specimens to exclude tuberculosis. CONCLUSIONS: MTD improved diagnostic accuracy and timeliness and reduced unnecessary respiratory isolation, treatment, and contact investigations. It was cost saving in patients with HIV, homelessness, or substance abuse, but not in others.


Assuntos
Técnicas de Diagnóstico Molecular/economia , Técnicas de Diagnóstico Molecular/métodos , Mycobacterium tuberculosis/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/economia , Técnicas de Amplificação de Ácido Nucleico/métodos , Tuberculose Pulmonar/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Estudos de Coortes , Análise Custo-Benefício , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/genética , Estudos Retrospectivos , Fatores de Tempo , Estados Unidos , Adulto Jovem
17.
Sci Rep ; 13(1): 21913, 2023 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-38081881

RESUMO

Self-testing is an effective tool to bridge the testing gap for several infectious diseases; however, its performance in detecting SARS-CoV-2 using antigen-detection rapid diagnostic tests (Ag-RDTs) has not been systematically reviewed. This study aimed to inform WHO guidelines by evaluating the accuracy of COVID-19 self-testing and self-sampling coupled with professional Ag-RDT conduct and interpretation. Articles on this topic were searched until November 7th, 2022. Concordance between self-testing/self-sampling and fully professional-use Ag-RDTs was assessed using Cohen's kappa. Bivariate meta-analysis yielded pooled performance estimates. Quality and certainty of evidence were evaluated using QUADAS-2 and GRADE tools. Among 43 studies included, twelve reported on self-testing, and 31 assessed self-sampling only. Around 49.6% showed low risk of bias. Overall concordance with professional-use Ag-RDTs was high (kappa 0.91 [95% confidence interval (CI) 0.88-0.94]). Comparing self-testing/self-sampling to molecular testing, the pooled sensitivity and specificity were 70.5% (95% CI 64.3-76.0) and 99.4% (95% CI 99.1-99.6), respectively. Higher sensitivity (i.e., 93.6% [95% CI 90.4-96.8] for Ct < 25) was estimated in subgroups with higher viral loads using Ct values as a proxy. Despite high heterogeneity among studies, COVID-19 self-testing/self-sampling exhibits high concordance with professional-use Ag-RDTs. This suggests that self-testing/self-sampling can be offered as part of COVID-19 testing strategies.Trial registration: PROSPERO: CRD42021250706.


Assuntos
Teste para COVID-19 , COVID-19 , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , Testes de Diagnóstico Rápido , Autoteste , Sensibilidade e Especificidade
18.
Nat Cancer ; 4(1): 96-107, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36581734

RESUMO

Patients with cancer are at high risk of severe coronavirus disease 2019 (COVID-19), with high morbidity and mortality. Furthermore, impaired humoral response renders severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccines less effective and treatment options are scarce. Randomized trials using convalescent plasma are missing for high-risk patients. Here, we performed a randomized, open-label, multicenter trial ( https://www.clinicaltrialsregister.eu/ctr-search/trial/2020-001632-10/DE ) in hospitalized patients with severe COVID-19 (n = 134) within four risk groups ((1) cancer (n = 56); (2) immunosuppression (n = 16); (3) laboratory-based risk factors (n = 36); and (4) advanced age (n = 26)) randomized to standard of care (control arm) or standard of care plus convalescent/vaccinated anti-SARS-CoV-2 plasma (plasma arm). No serious adverse events were observed related to the plasma treatment. Clinical improvement as the primary outcome was assessed using a seven-point ordinal scale. Secondary outcomes were time to discharge and overall survival. For the four groups combined, those receiving plasma did not improve clinically compared with those in the control arm (hazard ratio (HR) = 1.29; P = 0.205). However, patients with cancer experienced a shortened median time to improvement (HR = 2.50; P = 0.003) and superior survival with plasma treatment versus the control arm (HR = 0.28; P = 0.042). Neutralizing antibody activity increased in the plasma cohort but not in the control cohort of patients with cancer (P = 0.001). Taken together, convalescent/vaccinated plasma may improve COVID-19 outcomes in patients with cancer who are unable to intrinsically generate an adequate immune response.


Assuntos
COVID-19 , Neoplasias , Humanos , COVID-19/terapia , SARS-CoV-2 , Imunização Passiva/efeitos adversos , Resultado do Tratamento , Soroterapia para COVID-19 , Anticorpos Antivirais , Neoplasias/terapia
19.
Microbiol Spectr ; 10(5): e0122922, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36066256

RESUMO

Access to reverse transcription-PCR (RT-PCR) testing, the gold standard for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection, is limited throughout the world, due to restricted resources, available infrastructure, and high costs. Antigen-detecting rapid diagnostic tests (Ag-RDTs) overcome some of these barriers, but independent clinical validations in settings of intended use are scarce. To inform the World Health Organization's (WHO) emergency use listing (EUL) procedure and ensure affordable, high-quality Ag-RDTs, we assessed the performance and ease of use of the SureStatus for SARS-CoV-2. For this prospective, multicenter diagnostic accuracy study, we recruited unvaccinated participants with presumed SARS-CoV-2 infection in India and Germany from December 2020 to March 2021, when the Alpha (B.1.1.7) variant was predominantly circulating. Paired swabs were performed for (i) routine clinical RT-PCR testing (sampling was either nasopharyngeal [NP] or combined NP and oropharyngeal [NP/OP]) and (ii) Ag-RDT (sampling was NP). Performance of the Ag-RDT was compared to RT-PCR overall and by predefined subgroups, e.g., cycle threshold (CT) value, symptoms, and days from symptom onset. To understand the usability, a system usability scale (SUS) questionnaire and ease-of-use (EoU) assessment were performed. A total of 1,119 participants were included in the analysis, of whom 205 (18.3%) were RT-PCR positive. SureStatus detected 169 out of 205 RT-PCR-positive participants, reporting a sensitivity of 82.4% (95% confidence interval [CI]: 76.6% to 87.1%) and a specificity of 98.5% (95% CI: 97.4% to 99.1%). In the first 7 days post-symptom onset, the sensitivity was 90.7% (95% CI: 83.5% to 94.9%), when CT values were low and viral loads were high. The test was characterized as easy to use (SUS, 85/100) and considered suitable for point-of-care settings, although quality concerns were raised due to visibly contaminated packaging of swabs included in the test kits. The SureStatus diagnostic test can be considered a reliable test during the first week of SARS-CoV-2 infection, with high sensitivity in combination with excellent usability. IMPORTANCE Our manufacturer-independent, prospective diagnostic accuracy study assessed clinical performance in participants presumed to have a SARS-CoV-2 infection at three study sites in two countries. We assessed the accuracy overall and in predefined subgroups (CT values and symptom duration). SureStatus performed with high sensitivity. Its sensitivity was particularly high in the first 3 days after symptom onset and when CT values were low (i.e., the viral load was high). The system usability and ease-of-use assessment complements the accuracy assessment of the test and highlights critical factors to facilitate the widespread use of SureStatus in point-of-care settings. The high sensitivity demonstrated by the evaluated Ag-RDT within the first days of symptoms, when most transmission occurs, supports the role of Ag-RDTs for public health-relevant screening. Evidence from this study was used to inform the World Health Organization Emergency Use Listing procedure.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Testes Diagnósticos de Rotina , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Sensibilidade e Especificidade , Organização Mundial da Saúde
20.
EBioMedicine ; 75: 103774, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34959134

RESUMO

BACKGROUND: Antigen-detecting rapid diagnostic tests (Ag-RDTs) for SARS-CoV-2 are important diagnostic tools. We assessed clinical performance and ease-of-use of seven Ag-RDTs in a prospective, manufacturer-independent, multi-centre cross-sectional diagnostic accuracy study to inform global decision makers. METHODS: Unvaccinated participants suspected of a first SARS-CoV-2 infection were recruited at six sites (Germany, Brazil). Ag-RDTs were evaluated sequentially, with collection of paired swabs for routine reverse transcription polymerase chain reaction (RT-PCR) testing and Ag-RDT testing. Performance was compared to RT-PCR overall and in sub-group analyses (viral load, symptoms, symptoms duration). To understandusability a System Usability Scale (SUS) questionnaire and ease-of-use (EoU) assessment were performed. FINDINGS: 7471 participants were included in the analysis. Sensitivities across Ag-RDTs ranged from 70·4%-90·1%, specificities were above 97·2% for all Ag-RDTs but one (93·1%).Ag-RDTs, Mologic, Bionote, Standard Q, showed diagnostic accuracy in line with WHO targets (> 80% sensitivity, > 97% specificity). All tests showed high sensitivity in the first three days after symptom onset (≥87·1%) and in individuals with viral loads≥ 6 log10SARS-CoV2 RNA copies/mL (≥ 88·7%). Usability varied, with Rapigen, Bionote and Standard Q reaching very good scores; 90, 88 and 84/100, respectively. INTERPRETATION: Variability in test performance is partially explained by variable viral loads in population evaluated over the course of the pandemic. All Ag-RDTs reach high sensitivity early in the disease and in individuals with high viral loads, supporting their role in identifying transmission relevant infections. For easy-to-use tests, performance shown will likely be maintained in routine implementation. FUNDING: Ministry of Science, Research and Arts, State of Baden-Wuerttemberg, Germany, internal funds from Heidelberg University Hospital, University Hospital Charité - Universitätsmedizin Berlin, UK Department of International Development, WHO, Unitaid.


Assuntos
Antígenos Virais/imunologia , Teste Sorológico para COVID-19 , COVID-19 , Sistemas Automatizados de Assistência Junto ao Leito , SARS-CoV-2/imunologia , Adulto , COVID-19/diagnóstico , COVID-19/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA