Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
PLoS Med ; 16(9): e1002907, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31509529

RESUMO

BACKGROUND: Few studies have evaluated the association between preexisting vitamin D deficiency and incident tuberculosis (TB). We assessed the impact of baseline vitamins D levels on TB disease risk. METHODS AND FINDINGS: We assessed the association between baseline vitamin D and incident TB in a prospective cohort of 6,751 HIV-negative household contacts of TB patients enrolled between September 1, 2009, and August 29, 2012, in Lima, Peru. We screened for TB disease at 2, 6, and 12 months after enrollment. We defined cases as household contacts who developed TB disease at least 15 days after enrollment of the index patient. For each case, we randomly selected four controls from among contacts who did not develop TB disease, matching on gender and year of age. We also conducted a one-stage individual-participant data (IPD) meta-analysis searching PubMed and Embase to identify prospective studies of vitamin D and TB disease until June 8, 2019. We included studies that assessed vitamin D before TB diagnosis. In the primary analysis, we defined vitamin D deficiency as 25-(OH)D < 50 nmol/L, insufficiency as 50-75 nmol/L, and sufficiency as >75nmol/L. We estimated the association between baseline vitamin D status and incident TB using conditional logistic regression in the Lima cohort and generalized linear mixed models in the meta-analysis. We further defined severe vitamin D deficiency as 25-(OH)D < 25 nmol/L and performed stratified analyses by HIV status in the IPD meta-analysis. In the Lima cohort, we analyzed 180 cases and 709 matched controls. The adjusted odds ratio (aOR) for TB risk among participants with baseline vitamin D deficiency compared to sufficient vitamin D was 1.63 (95% CI 0.75-3.52; p = 0.22). We included seven published studies in the meta-analysis and analyzed 3,544 participants. In the pooled analysis, the aOR was 1.48 (95% CI 1.04-2.10; p = 0.03). The aOR for severe vitamin D deficiency was 2.05 (95% CI 0.87-4.87; p trend for decreasing 25-(OH)D levels from sufficient vitamin D to severe deficiency = 0.02). Among 1,576 HIV-positive patients, vitamin D deficiency conferred a 2-fold (aOR 2.18, 95% CI 1.22-3.90; p = 0.01) increased risk of TB, and the aOR for severe vitamin D deficiency compared to sufficient vitamin D was 4.28 (95% CI 0.85-21.45; p = 0.08). Our Lima cohort study is limited by the short duration of follow-up, and the IPD meta-analysis is limited by the number of possible confounding covariates available across all studies. CONCLUSION: Our findings suggest vitamin D predicts TB disease risk in a dose-dependent manner and that the risk of TB disease is highest among HIV-positive individuals with severe vitamin D deficiency. Randomized control trials are needed to evaluate the possible role of vitamin D supplementation on reducing TB disease risk.


Assuntos
Tuberculose/epidemiologia , Deficiência de Vitamina D/epidemiologia , Vitamina D/análogos & derivados , Adolescente , Adulto , Biomarcadores/sangue , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Humanos , Incidência , Lactente , Recém-Nascido , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Peru/epidemiologia , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Tuberculose/diagnóstico , Tuberculose/microbiologia , Vitamina D/sangue , Deficiência de Vitamina D/sangue , Deficiência de Vitamina D/diagnóstico , Adulto Jovem
2.
Anal Bioanal Chem ; 407(30): 9009-18, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26427500

RESUMO

An analytical method based on micellar liquid chromatography was developed to determine the concentration of three catecholamines (epinephrine, norepinephrine, and dopamine) in urine. The detection of these compounds in urine can be useful to diagnose several diseases, related to stress and sympathoadrenal system dysfunction, using a non-invasive collection procedure. The sample pretreatment was a simple dilution in a micellar solution, filtration, and direct injection, thus avoiding time-consuming and tedious extraction steps. Therefore, there is no need to use an internal standard. The three catecholamines were eluted using a C18 column and a mobile phase of 0.055 M sodium dodecyl sulfate-1.5% methanol buffered at pH 3.8 running at 1.5 mL/min under isocratic mode in less than 25 min. The detection was performed by amperometry applying a constant potential of +0.5 V. The procedure was validated following the guidelines of the European Medicines Agency in terms of the following: calibration range (0.09-5 µg/mL), linearity (r(2) > 0.9995), limit of detection (0.02 µg/mL), within- and between-run accuracy (-6.5 to +8.4%) and precision (<10.2%), dilution integrity, matrix effect, robustness (<8.4), and stability. The obtained values were below those required by the guide. The method was rapid, easy-to-handle, eco-friendly, and safe and provides reliable quantitative data, and is thus useful for routine analysis. The procedure was applied to the analysis of epinephrine, norepinephrine, and dopamine in urine samples from patients of a local hospital.


Assuntos
Neoplasias das Glândulas Suprarrenais/urina , Cromatografia Líquida/métodos , Dopamina/urina , Epinefrina/urina , Norepinefrina/urina , Feocromocitoma/urina , Hospitalização , Humanos
3.
BMC Infect Dis ; 11: 349, 2011 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-22171844

RESUMO

BACKGROUND: Deficient serum vitamin D levels have been associated with incidence of tuberculosis (TB), and latent tuberculosis infection (LTBI). However, to our knowledge, no studies on vitamin D status and tuberculin skin test (TST) conversion have been published to date. The aim of this study was to estimate the associations of serum 25-hydroxyvitamin D3 (25[OH]D) status with LTBI prevalence and TST conversion in contacts of active TB in Castellon (Spain). METHODS: The study was designed in two phases: cross-sectional and case-control. From November 2009 to October 2010, contacts of 42 TB patients (36 pulmonary, and 6 extra-pulmonary) were studied in order to screen for TB. LTBI and TST conversion cases were defined following TST, clinical, analytic and radiographic examinations. Serum 25(OH)D levels were measured by electrochemiluminescence immunoassay (ECLIA) on a COBAS® 410 ROCHE® analyzer. Logistic regression models were used in the statistical analysis. RESULTS: The study comprised 202 people with a participation rate of 60.1%. Only 20.3% of the participants had a sufficient serum 25(OH)D (≥ 30 ng/ml) level. In the cross-sectional phase, 50 participants had LTBI and no association between LTBI status and serum 25(OH)D was found. After 2 months, 11 out of 93 negative LTBI participants, without primary prophylaxis, presented TST conversion with initial serum 25(OH)D levels: a:19.4% (7/36): < 20 ng/ml, b:12.5% (4/32):20-29 ng/ml, and c:0%(0/25) ≥ 30 ng/ml. A sufficient serum 25(OH)D level was a protector against TST conversion a: Odds Ratio (OR) = 1.00; b: OR = 0.49 (95% confidence interval (CI) 0.07-2.66); and c: OR = 0.10 (95% CI 0.00-0.76), trends p = 0.019, adjusted for high exposure and sputum acid-fast bacilli positive index cases. The mean of serum level 25(OH)D in TST conversion cases was lower than controls,17.5 ± 5.6 ng/ml versus 25.9 ± 13.7 ng/ml (p = 0.041). CONCLUSIONS: The results suggest that sufficient serum 25(OH)D levels protect against TST conversion.


Assuntos
Calcifediol/sangue , Tuberculose Latente/sangue , Tuberculose Latente/epidemiologia , Teste Tuberculínico , Adulto , Calcifediol/deficiência , Estudos de Casos e Controles , Busca de Comunicante , Estudos Transversais , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Prevalência , Fatores de Risco , Espanha/epidemiologia , Tuberculose Pulmonar/sangue , Tuberculose Pulmonar/epidemiologia
4.
Antibiotics (Basel) ; 9(2)2020 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-32075155

RESUMO

Mebendazole is an anthelmintic drug used in cattle production. However, residues may occur in produced food and in excretions, jeopardizing population health. A method based on micellar liquid chromatography (MLC) was developed to determine mebendazole in dairy products (milk, cheese, butter, and curd) and nitrogenous waste (urine and dung) from bovine animals. Sample treatment was expedited to simple dilution or solid-to-liquid extraction, followed by filtration and direct injection of the obtained solution. The analyte was resolved from matrix compounds in less than 8 min, using a C18 column and a mobile phase made up of 0.15 M sodium dodecyl sulfate (SDS)-6% 1-pentanol phosphate buffered at pH 7, and running at 1 mL/min under isocratic mode. Detection was performed by absorbance at 292 nm. The procedure was validated according to the guidelines of the EU Commission Decision 2002/657/EC in terms of: specificity, method calibration range (from the limit of quantification to 25-50 ppm), sensitivity (limit of detection 0.1-0.2 ppm; limit of quantification, 0.3-0.6 ppm), trueness (92.5-102.3%), precision (<7.5%, expressed at RSD), robustness, and stability. The method is reliable, sensitive, easy-to-handle, eco-friendly, safe, inexpensive, and provides a high sample-throughput. Therefore, it is useful for routine analysis as a screening or quantification method in a laboratory for drug-residue control.

5.
Artigo em Inglês | MEDLINE | ID: mdl-31055191

RESUMO

A Micellar Chromatographic method to determine rivaroxaban in plasma and urine has been developed. The samples were dissolved in the mobile phase (SDS 0.05 M - 1-propanol 12.5%, phosphate buffered at pH 7) and 20 µL directly injected, avoiding the extraction and purification steps. Using a C18 column and running under isocratic mode at 1 mL/min, analyte was eluted without interference from the matrix in <6.0 min. The detection absorbance wavelength was set to 250 nm. The procedure was validated by Food and Drug Administration guidelines in terms of: system suitability, calibration range (0.05-5 mg/L), linearity, sensitivity, robustness, carry-over effect, specificity, accuracy (-11.1 to 4.2%), precision (<19.9%), stability and analysis of incurred samples. The method was found reliable, practical, easy-to-conduct, rapid, relatively eco-friendly, safe, inexpensive, widely available and with a high sample throughput. The method was applied to the analysis of incurred samples, including incurred sample reanalysis, to verify that the instrumentation works correctly. In addition, the constants of the different partition equilibria occurring in the column were elucidated in order to have a better comprehension of the theoretical aspects of the retention mechanism. A moderately strong association between rivaroxaban and the stationary phase and the micelles was found, weakened by short chain alcohol.


Assuntos
Cromatografia Líquida/métodos , Rivaroxabana/sangue , Rivaroxabana/urina , Humanos , Limite de Detecção , Modelos Lineares , Micelas , Reprodutibilidade dos Testes , Rivaroxabana/farmacocinética
6.
Antibiotics (Basel) ; 8(4)2019 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-31731615

RESUMO

A method based on micellar liquid chromatography was developed to determine oxolinic acid, ciprofloxacin, enrofloxacin, and sarafloxacin in eggs and egg products. The antimicrobial drugs were obtained in a micellar solution which was directly injected. The analytes were resolved using a C18 column and a mobile phase of 0.05 M sodium dodecyl sulfate-7.5% 1-propanol-0.5% triethylamine, buffered at pH 3 with phosphate salt, running under the isocratic mode. The signal was monitored by fluorescence. Validation was successfully performed according to the EU Commission Decision 2002/657/EC in terms of specificity, calibration range (LOQ to 1 mg/kg), linearity (R2 > 0.9991), limit of detection and decision limit (0.01-0.05 mg/kg), limit of quantification (0.025-0.150 mg/kg), detection capability (<0.4 times decision limit), trueness (-14.2% to +9.8%), precision (<14.0%), robustness, and stability. The procedure was environmentally friendly, safe, easy-to-conduct, inexpensive, and had a high sample throughput, thus it is useful for routine analysis as a screening method in a laboratory for food residue control.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA