Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
1.
Skin Res Technol ; 30(4): e13687, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38566505

RESUMO

BACKGROUND: The physical appearance of an individual plays a primary role as it influences the opinion of the viewer. For this reason, orthodontic therapy to improve perceived aesthetics is in high demand among patients. This factor, combined with the increase in the number of non-invasive facial aesthetic treatments, has led to the need to understand potential risk factors in the application of medical devices to the perioral skin in patients with fixed orthodontic appliances. The aim of this study was to evaluate in vitro heating of the orthodontic bracket following electromagnetic fields and negative pressure (V-EMF) used as an anti-aging treatment. METHODS: Two different types of titanium alloy wires, one made of "beta-Titanium" alloy and the other "Ni-Ti" (DW Lingual Systems GmbH-Bad Essen-Germany) were used. The orthodontic wires and brackets mounted on a resin mouth were covered with porcine muscle tissue, then subjected to anti-aging therapy with a Bi-one LifeTouchTherapy medical device (Expo Italia Srl-Florence-Italy) which generates a combination of vacuum and electromagnetic fields (V-EMF) already adopted for antiaging therapy. During administration of the therapy, the orthodontic brackets and porcine tissue were thermally monitored using a Wavetek Materman TMD90 thermal probe (Willtek Communications GmbH-Germany). In total 20 orthodontic mouths were used, 10 with Beta Titanium wires and 10 with Nickel Titanium wires. RESULTS: A temperature increase of about 1°C was recorded in each group. The outcome of the present research shows that the absolute temperatures measured on orthodontic appliances, which, despite having a slightly different curve, both show an increase in temperature of 1.1°C at the end of the session, thus falling well within the safety range of 2°C as specified by the standard CENELEC EN 45502-1. Therefore, V-EMF therapy can be considered safe for the entire dental system and for metal prostheses, which tend to heat up at most as much as biological tissue (+0.9°C/1.1°C vs. 1.1°C/1.1°C). CONCLUSION: In conclusion, anti-aging therapy with V-EMF causes a thermal increase on orthodontic brackets that is not harmful to pulp health.


Assuntos
Campos Eletromagnéticos , Níquel , Titânio , Humanos , Animais , Suínos , Vácuo , Calefação , Fios Ortodônticos , Ligas , Teste de Materiais
2.
Medicina (Kaunas) ; 59(7)2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37512000

RESUMO

Background: The objective of this study was to evaluate the load transmitted to the peri-implant bone by seven different restorative materials in single-unit rehabilitations with morse taper implants using a strain gauge. Materials: In a polyurethane block that simulated type III bone, a morse taper platform implant was installed (3.5 × 11 mm) in the center and 1 mm below the test base surface, and four strain gauges were installed around the implant, simulating the mesial, distal, buccal and lingual positions. Seven similar hybrid abutment crowns were crafted to simulate a lower premolar using different materials: 1-PMMA; 2-glass ceramic over resin matrix; 3-PEEK + lithium disilicate; 4-metal-ceramic; 5-lithium disilicate; 6-zirconia + feldspathic; 7-monolithic zirconia. All groups underwent axial and oblique loads (45 degrees) of 150 N from a universal testing machine. Five measurements (n = 5) were performed with each material and for each load type; the microdeformation data underwent statistical analysis. The data were obtained in microdeformation (µÎµ), and the significance level was set at p ≤ 0.05. Results: There was no statistically significant difference in the evaluation among the materials under either the axial load or the oblique load at 45 degrees. In turn, in the comparison between axial load and oblique load, there was a difference in load for all materials. Conclusion: The restorative material did not influence the load transmitted to the bone. Furthermore, the load transmitted to the bone was greater when it occurred obliquely at 45° regardless of the material used. In conclusion, it appeared that the different elastic modulus of each material did not influence the load transmission to the peri-implant bone.


Assuntos
Coroas , Zircônio , Humanos
3.
Medicina (Kaunas) ; 59(1)2023 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-36676792

RESUMO

Objectives: The present study compared two implants with different macrogeometries placed in healed alveolar sites, evaluating the insertion torque (ITV) and implant stability quotient (ISQ) values at three different periods. Methods: Seventy patients with a total of 100 dental implants were allocated into two groups (n = 50 per group): DuoCone implants (DC group) that included 28 implants in the maxilla and 22 in the mandible, and Maestro implants (MAE group) that included 26 in the maxilla and 24 in the mandible. The ITV was measured during the implant placement, and the ISQ values were measured immediately at implant placement (baseline) and after 30 and 45 days. Results: The mean and standard deviations of the ITV were statistically significant (p < 0.0001), 56.4 ± 6.41 Ncm for the DC group and 29.3 ± 9.65 Ncm for the MAE group. In the DC group, the ISQs ranged between 61.1 ± 3.78 and 69.8 ± 3.86, while the MAE group presented similar values compared with the other group, ranging between 61.9 ± 3.92 and 72.1 ± 2.37. Conclusions: The value of implant insertion torque did not influence the ISQ values measured immediately after implant placement. However, the ITV influenced the ISQ values measured in the two initial periods of osseointegration, with implants installed with lower torques presenting higher ISQ values.


Assuntos
Maxila , Osseointegração , Humanos , Torque , Maxila/cirurgia , Mandíbula , Coleta de Dados
4.
Medicina (Kaunas) ; 59(7)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37512062

RESUMO

Objective: The primary objective of the present retrospective clinical study was to evaluate and compare the clinical performance presented by castable abutments developed for the MT system versus intermediate machined abutments, specifically regarding prosthetic or implant fractures/loss; the secondary objective was to verify the looseness of the abutments and the behavior of the peri-implant soft tissues. Methods: This clinical retrospective study was conducted on patients rehabilitated between 2019 and 2020. Inclusion criteria were patients in good general health, with an implants-supporting single crown; with solid machined abutments (control group) or castable UCLA abutments; with a connection portion (base) machined in cobalt-chrome (test group) over Morse taper DuoCone implants in the posterior mandible area; and at least two years in function. Clinical assessment was carried out by the same professional, considering the following parameters: (A) prosthetic: (i) loosening of the fixation screw, (ii) fracture of the screw and (iii) the number of times the patient had some type of complication after the installation of the prostheses were evaluated; (B) biological: (i) without keratinized mucosa (KM), (ii) 1 mm or less, (iii) between 1 and 2 mm and (iv) greater than 2 mm of KM width; and the presence or absence of mucositis. Furthermore, radiographic evaluation was performed in order to assess the marginal bone loss. These evaluations permitted to compare the groups analyzed and patients enrolled. Data were statistically analyzed, with the level of significance set at α = 0.05. Results: 79 patients with 120 MT implants were evaluated (80 castable UCLA abutments and 40 machined solid abutments). The follow-up was from 2 to 4 years. There was a 100% implant survival rate. Therefore, the control group showed two fractured abutments (5%) and no abutment loosening (95% for prosthetic survival rate), whereas the test group showed no abutment fracture but nine loosening screws (11.3%) (100% for prosthetic survival rate). Keratinized mucosa was considered thin or absent in 19 implants in the control group (47.5%) and 42 in the test group (52.5%). Mucositis was found in 11 implants in the control group (27.5%) and 27 in the test group (33.8%). A positive correlation was observed between the width of keratinized mucosa and mucositis (r = 0.521, p = 0.002). The mean marginal bone loss was 2.3 mm, ranging from 1.1 to 5.8 mm. No correlation was observed when considering marginal bone loss versus the three parameters (implant diameter, implant length and time of the prosthesis in function). Conclusions: The results suggest that UCLA-type abutments are a viable option for rehabilitating implants with Morse taper connections, suggesting lower fracture risk. Further research is necessary to confirm these findings and thoroughly evaluate the clinical performance and long-term outcomes.


Assuntos
Mucosite , Humanos , Estudos Retrospectivos , Próteses e Implantes
5.
J Prosthet Dent ; 128(1): 55-62, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33546856

RESUMO

STATEMENT OF PROBLEM: The use of reduced platform sets (implants and abutments) can help to control crestal bone loss around implants, which is essential for optimizing esthetics and biomechanical behavior. However, the information available on the fracture resistance of implants with a reduced platform is sparse. PURPOSE: The purpose of this in vitro study was to analyze the maximum fracture strength value of implants with different platform designs during quasistatic fatigue, followed by a simulation of different bone levels of cervical insertion. MATERIAL AND METHODS: One hundred and twenty sets of dental implants and abutments with different diameters and platform designs were tested. All implants had an internal hexagon connection and conical macrogeometry. Four groups (n=30) were studied: Ø4.0-mm implants with a regular matched platform (rMatch group), Ø4.0-mm implants with a regular switched platform (PSwitch group), Ø5.0-mm implants with a wide matched platform (wMatch group), and Ø5.0-mm implants with a wide switched platform (wSwitch group). Three conditions simulating different levels of bone position around the cervical portion of the implants were proposed: insertion at the implant shoulder level=0 mm (L0), level=3 mm of insertion loss (L3), and level=5 mm of insertion loss (L5). All sets of all groups and proposed insertion level were subjected to a fracture strength test at 30 degrees in relation to the axis of the sets in a universal testing machine. RESULTS: Regardless of the insertion levels tested, the switched platform implants (rSwitch and wSwitch groups) showed similar mean fracture strength values (P>.05), while the implants of matched platforms (rMatch and wMatch groups) showed different fracture strength values for all insertion levels tested (P<.001). CONCLUSIONS: The fracture strength values of the switched platform implants were lower at all insertion levels tested. However, for all insertion levels tested, the implants with a switched platform presented less deformation, whereas, in the matched platform implants, there was significant deformation of the implant structure.


Assuntos
Perda do Osso Alveolar , Doenças Ósseas Metabólicas , Implantes Dentários , Dente Suporte , Projeto do Implante Dentário-Pivô , Estética Dentária , Resistência à Flexão , Humanos
6.
Clin Oral Implants Res ; 29(6): 656-662, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26957224

RESUMO

OBJECTIVE: The purpose of the present study was to compare the insertion torque and implant stability quotient between different drill design for implant site preparation. MATERIALS AND METHODS: Synthetic blocks of bone (type I density) were used for drilling procedures. Three groups were evaluated: Group G1 - drilling with a single bur for a 4.2 mm conical implant; Group G2 and Group G3 - drilling with three consecutive burs for a 4.1 mm cylindrical implant and for a 4.3 mm conical implant respectively. For each group, 15 drilling procedures were performed without irrigation for 10-mm in-depth. The drilled hole quality (HQ) after the osteotomy for implant site preparation was measured in the five-first holes through a fully automated roundness/cylindricity instrument at three levels (top, middle, and bottom of the site). The insertion torque value (ITV) was achieved with a computed torquimeter and the implant stability quotient (ISQ) values were measured using a resonance frequency apparatus. RESULTS: The single drill (group 1) achieved a significantly higher ITV and ISQ than the multiple drills for osteotomy (groups 2 and 3). Group 1 and 3 displayed significantly better HQ than group 2. CONCLUSIONS: Within the limitations of the study, the results suggest that the hole quality, in addition to the insertion torque, may significantly affect implant primary stability.


Assuntos
Implantação Dentária Endóssea/instrumentação , Implantes Dentários , Análise do Estresse Dentário , Desenho de Equipamento , Técnicas In Vitro , Osteotomia/instrumentação , Análise de Frequência de Ressonância , Torque
7.
Clin Oral Implants Res ; 29(7): 772-778, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27041138

RESUMO

OBJECTIVE: This study aimed to measure the influence of drill length and irrigation system on heat production during osteotomy preparation for dental implants using bovine bone rib as experimental model. MATERIALS AND METHODS: Three groups were created: Group 1: drilling with three consecutive burs with double irrigation (internal and external) for a 4.0 mm conical implant; and Group 2 and Group 3: drilling with three consecutive burs with external irrigation for a 4.1 mm cylindrical implant and for a 4.3 mm conical implant, respectively. Four lengths were tested: 10, 12, 14 and 16 mm; in site prepared on bovine ribs using a surgical unit linked to a testing device, to standardize and simulate implant drilling procedures. Bone temperature variations were recorded using three thermocouples in different positions as of the crestal bone: 2 mm, position (p1); 7 mm, position 2 (p2); and 12 mm, position 3 (p3). RESULTS: The highest temperature changes were invariably recorded during the process of withdrawal. Significantly lower temperature changes (P < 0.02) could be recorded at maximum drilling depths during the shearing process regardless of drilling depth or irrigation method. Double irrigation was associated with significantly lower temperatures compared with external irrigation by the use of implant drills (P < 0.01). CONCLUSIONS: Within the limitations of this ex vivo study was possible concluded that the use a double irrigation system in multiple conventional drill for osteotomy can decrease the heat generation when increase the drill length.


Assuntos
Implantação Dentária Endóssea , Animais , Bovinos , Implantação Dentária Endóssea/efeitos adversos , Implantação Dentária Endóssea/instrumentação , Implantação Dentária Endóssea/métodos , Temperatura Alta , Osteotomia/efeitos adversos , Osteotomia/instrumentação , Osteotomia/métodos , Costelas/cirurgia , Irrigação Terapêutica
8.
Clin Oral Implants Res ; 29(11): 1176, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-27191920

RESUMO

OBJECTIVE: The aim of this study was to evaluate the effect of topical applications of melatonin and apigenin (4',5,7-trihydroxyflavone) on new bone formation in post-extraction sockets after 30, 60 and 90 days. MATERIALS AND METHODS: Six American fox hounds were used in the study, extracting mandibular premolars (P2, P3 and P4) and first molar (M1). Melatonin or apigenin impregnated in collagen sponges were applied at P3, P4 and M1 sites in both hemimandibles; P2 sites were used as control sites. Bone biopsies were taken at 30, 60 and 90 days and stained with hematoxylin-eosin. RESULTS: At 30 days, a higher percentage of immature bone was observed in the control group (58.11 ± 1.76%) than in the apigenin (34.11 ± 1.02%) and melatonin groups (24.9 ± 0.14%) with significant differences between the three groups (P < 0.05). At 60 days, results were significantly better at melatonin sites (10.34 ± 1.09%) than apigenin (19.22 ± 0.35%) and control sites (36.7 ± 1.11%) (P < 0.05). At 90 days, immature bone percentages were similar for all groups. New bone formation was higher in melatonin group (79.56 ± 1.9%) than apigenin (68.89 ± 1.5%) and control group (58.87 ± 0.12%). CONCLUSIONS: Topical applications of either melatonin or apigenin have a potential to accelerate bone tissue in early healing stages; melatonin was seen to have stimulated bone maturation to a greater extent at the 60 days of follow-up.

9.
Clin Oral Implants Res ; 29(7): 785-791, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27381553

RESUMO

OBJECTIVE: This study assessed the bone formation around titanium surface incorporating the calcium-magnesium (CaMg) deposited by blasted in rabbit tibia bone to determine whether this surface would further enhance bone healing compared with commercially available implant surface. MATERIAL AND METHODS: The deposition of CaMg on the titanium SLA surface were obtained by blasting formed the experimental group (EX group), while implants with traditional SLA surface were used as control group (CO group), in this study. Fifty cylindrical threaded implants with a length of 8 mm were used (P = 25 per group). Five implants of each group were used to surface characterization by scanning electron microscopy, energy dispersive spectrometry, and optical profilometry. Ten New Zealand white rabbits received 40 implants (n = 20 per group). Resonance frequency analysis was performed three times (0, 4, and 6 weeks). Histomorphometric analysis was performed 4 and 6 weeks after implantation. Statistical significance was set at P < 0.05. RESULTS: Blasted CaMg deposition on SLA implant surface displayed almost identical surface morphologies and R(a) values at the micron scale. In comparing the implant stability quotient at the three time points, highly significant statistic differences were found (P < 0.001). Histomorphological analysis showed higher degrees of bone organization in the samples of test implant surfaces at both implantation times. CONCLUSION: Within the limitations of this study, the results indicate that the deposition of CaMg on the SLA titanium surface may be effective in enhancing the osseointegration of moderately rough grit-blasted implants by increasing the degree of bone-implant contact.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Osseointegração , Titânio , Animais , Cálcio , Implantação Dentária Endóssea/instrumentação , Magnésio , Coelhos , Análise de Frequência de Ressonância , Tíbia/anatomia & histologia , Tíbia/cirurgia
10.
J Craniofac Surg ; 28(2): 552-558, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27984434

RESUMO

OBJECTIVES: The aim of this study is to evaluate the effect of the surface modification and cervical implant design on the bone remodeling in implants installed at the crestal and subcrestal bone level. METHODS: Ten American Fox Hound of approximately 1 year of age, each weighing approximately 14 to 15 kg, were used for this study. Two different dental implant macrodesign were used: cylindric-conical with 3.5 mm of diameter and 9 in length (implant A) and conical with 2.9 mm of diameter and 9 mm in length (implant B). Two surfaces were used: sandblasting and acid etching (surface 1) and sandblasting and acid etching, then maintained in an isotonic solution of 0.9% sodium chloride (surface 2). Four groups were performed (n = 20 implants): Group A1 (implant A with the surface 1), Group A2 (implant A with surface 2), Group B1 (implant B with surface 1), and Group B2 (implant B with surface 2). The mandibular premolars and molars (P1, P2, P3, M1) were removed and, after 2 months of healing, implants were inserted at the crestal and 2 mm subcrestal position related to the buccal bone level. Analysis was performed at 4 and 8 weeks. Histomorphometry with longitudinal measurements and bone implant contact, bone remodeling and implant stability quotient analysis were realized. RESULTS: The surface 2 showed to get more close contact between implant and new bone formed after implant placement and more stability surrounding platform both at 4 and 8 weeks. Surface 2 groups and subrestally placed showed to have better results in terms of linear measurements, with less bone loss and soft tissue distance to the IS. The data showed significant differences among the groups (P < 0.001). CONCLUSIONS: Surface modification (surface 2) has shown to be an effective alternative to conventional surface with better results in situations placed subcrestally and combined with implant design.


Assuntos
Remodelação Óssea/fisiologia , Implantes Dentários , Planejamento de Prótese Dentária , Perda do Osso Alveolar/fisiopatologia , Animais , Dente Pré-Molar/cirurgia , Implantação Dentária Endóssea/métodos , Cães , Dente Molar/cirurgia , Extração Dentária/métodos , Cicatrização/fisiologia
11.
Clin Oral Implants Res ; 27(9): 1123-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26408047

RESUMO

OBJECTIVE: This study evaluated the effect of cigarette smoking on the percentage of early bone-to-implant contact (BIC%), the bone density in the threaded area (BA%) as well as the bone density outside the threaded area (BD%) around micro-implants with sandblasted acid-etched surface retrieved from human jaws. MATERIAL AND METHODS: Twenty-two subjects (mean age 55.4 ± 4.5 years) were divided in two groups: smokers (n = 11 subjects) and never-smokers (n = 11 subjects). Each subject received one micro-implant during conventional mandible or maxilla implant surgery. After 8 weeks, the micro-implants and the surrounding tissue were removed and prepared for histomorphometric analysis. RESULTS: Two micro-implants placed in smokers showed no osseointegration. Early stages of maturation of the newly formed bone were present, mainly in the never-smokers. Marginal bone loss, gap, and fibrous tissue were present around some implants retrieved from smokers. Histometric evaluation indicated that the mean BIC% ranged between 25.9 ± 9.1 and 39.8 ± 14.2 for smokers and non-smokers, respectively (P = 0.02). Smokers presented 28.6 ± 10.1 of BA% while never-smokers showed 46.4 ± 18.8 (P = 0.04). The mean of BD% ranged between 19.1 ± 7.6 and 28.5 ± 18.8 for smokers and never-smokers, respectively (P = 0.21). CONCLUSION: Cigarette smoking has a detrimental effect on early bone tissue response around sandblasted acid-etched implant surface topographies.


Assuntos
Implantação Dentária Endóssea , Osseointegração , Fumar/efeitos adversos , Processo Alveolar/efeitos dos fármacos , Processo Alveolar/patologia , Densidade Óssea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração/efeitos dos fármacos , Estudos Prospectivos
12.
Clin Oral Implants Res ; 27(5): 577-82, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26037595

RESUMO

OBJECTIVES: The present study measured implant stability quotient (ISQ) values at three different time points after surgical procedures to compare whether the stability values differed between implants placed in fresh extraction sockets versus healed alveolar sites. MATERIALS AND METHODS: To measure implant stability, resonance frequency analysis (RFA) was performed in 77 patients (53 women, 24 men) with a total of 120 dental implants. These implants were divided into two groups: Group 1 included 60 implants in healed alveolar sites (22 in the maxilla, 38 in the mandible), and Group 2 included 60 implants in fresh sockets (41 in the maxilla, 19 in the mandible). Implant stability was measured immediately at implant placement (baseline), 90, and 150 days later. Statistical analysis was made using a multivariate regression linear model at implant level (α = 0.05). RESULTS: Overall, the means and standard deviations of the ISQ values were 62.7 ± 7.14 (95% confidence interval [CI], 39-88) at baseline, 70.0 ± 6.22 (95% CI, 46-88) at 90 days, and 73.4 ± 5.84 (95% CI, 58-88) at 150 days. In Group 1, the ISQs ranged between 64.3 ± 6.20 and 75.0 ± 5.69, while in Group 2, presented lower values that ranged between 61.2 ± 8.09 and 71.9 ± 5.99 (P = 0.002). Anatomic location and times periods were the only identified variables with an influence on ISQ values at implant level (P < 0.0001). CONCLUSIONS: The stabilities of the implants placed in the fresh sockets and in healed sites exhibited similar evolutions in ISQ values and thus osseointegration; however, the implants in the healed alveolar sites exhibited superior values at all time points.


Assuntos
Processo Alveolar/cirurgia , Implantes Dentários , Osseointegração , Alvéolo Dental/cirurgia , Feminino , Humanos , Masculino , Mandíbula/cirurgia , Maxila/cirurgia
13.
J Craniofac Surg ; 27(3): 784-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27100634

RESUMO

OBJECTIVE: This study investigated the osteoblastic behavior to yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) surface after different intensities of erbium, chromium-doped:yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser irradiation treatment. MATERIALS AND METHODS: Y-TZP blocks were randomized divided into 4 groups to Er,Cr:YSGG laser irradiation: group G1 = control (no laser irradiation); group G2 = 1.5 W; group G3 = 3.0 W; group G4 = 5.0 W, with air-water irrigation. The irradiated surface roughness (Sa and Ra) topography was evaluated. MC3T3-E1 osteoblast cells were cultured and seeded onto the treated surfaces at a plate density of 1 × 10 cells/mL. At the third and seventh days cell proliferation was measured by the colorimetric assay methods. The specimens were prepared to scanning electron microscope to observe adhesion and morphology of cells. RESULTS: MTT assay showed adhesion and proliferation of MC3T3-E1 cells in all groups. Compared with group G1 (control), the group G2 had a proliferation 1.4% higher (P > 0.05), the group G3 had a proliferation 3.1% higher (P < 0.05) and group G4 had a proliferation 4.5% higher (P < 0.01). After 7 days there was no difference among the groups (ANOVA, Newman-Keuls). CONCLUSIONS: Er,Cr:YSGG laser irradiation may have contributed to the greater and earlier cell spreading that was observed with the Y-TZP without alterations on surface topography.


Assuntos
Terapia com Luz de Baixa Intensidade/métodos , Osteoblastos/citologia , Osteoblastos/efeitos da radiação , Zircônio , Cromo , Relação Dose-Resposta a Droga , Érbio , Gálio , Humanos , Técnicas In Vitro , Lasers de Estado Sólido/uso terapêutico , Microscopia Eletrônica de Varredura , Escândio , Propriedades de Superfície , Ítrio
14.
J Prosthet Dent ; 116(4): 529-535, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27157608

RESUMO

STATEMENT OF PROBLEM: Esthetic factors influence the decision to use titanium or zirconia abutments in anterior regions. Clinicians may have concerns about the durability and behavior of these zirconia abutments. PURPOSE: The purpose of this in vitro study was to evaluate the longitudinal and transverse long axes of the implant-abutment interface before and after the cyclic loading of titanium and zirconia abutments with an external hexagon. MATERIAL AND METHODS: Forty dental implants with an external hexagon and 40 corresponding abutments made of titanium (Ti) and zirconia (Zr) were subjected to cyclic load (c1) versus no load (c2). The longitudinal and transverse axes of 4 experimental groups (Tic1, Tic2, Zrc1, and Zrc2) were analyzed (vertical/horizontal adjustment) using a scanning electron microscope at ×1000 magnification. The differences among the groups were determined by 1-way analysis of variance (ANOVA) and post hoc Tukey tests (α=.05). T tests were used to identify the statistically significant differences between each group and each condition (α=.05). RESULTS: Significant differences were found among the groups with respect to the misfits analyzed in the 2 sections (longitudinal and transverse) before and after load application (P<.05). The behaviors of the groups differed particularly with regard to the accommodation of sets (abutment/implant) after the application of cyclic loads (P<.05). CONCLUSION: The use of zirconia abutments in titanium implants can cause changes to and/or permanent deformation of the implant hexagon.


Assuntos
Dente Suporte , Projeto do Implante Dentário-Pivô , Análise do Estresse Dentário , Dureza , Humanos , Técnicas In Vitro , Microscopia Eletrônica de Varredura , Titânio , Zircônio
15.
J Craniofac Surg ; 26(5): 1482-6, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26114512

RESUMO

OBJECTIVES: This study was designed to compare the cortical bone reaction following traditional osteotomy or the use of a single-use final drill in the osseointegration of implants in the tibia of rabbits. MATERIALS AND METHODS: For this study, 48 conical implants, of standard surface type and design and manufactured by the same company, were inserted into the tibiae of 12 rabbits and removed after 30 or 60 days for histologic analysis. Two test groups were prepared according to the drill sequence used for the osteotomy at the preparation sites: in the control group was used a conventional drill sequence with several uses, whereas the test group (tesG) used a single-use final drill. The bone-to-implant contact and qualitative factors of the resulting cortical bone were assessed. RESULTS: Both techniques produced good implant integration. Differences in the linear bone-to-implant contact were observed between the drilling procedures as time elapsed in vivo, with the tesG appearing to have clinical advantages. Both groups exhibited new bone in quantity and in quality; however, the tesG exhibited a higher level of new bone deposition than the control group. CONCLUSIONS: Within the limitations of this study, the findings suggest that the use of a single-use final drill leads to better and faster organization of the cortical bone area during the evaluated period and may avoid the possible problems that can be caused by worn drills.


Assuntos
Osseointegração/fisiologia , Osteotomia/métodos , Próteses e Implantes , Tíbia/cirurgia , Animais , Modelos Animais de Doenças , Coelhos , Tíbia/citologia
16.
Clin Oral Investig ; 18(3): 715-20, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23860902

RESUMO

OBJECTIVE: The aim of the present in vitro study was to assess resistance to static fatigue of implants with different connections at various insertion levels. MATERIALS AND METHODS: Sixty implants and abutments were used with the smallest diameter of each model. Four groups (n = 15) were created on the basis of the implant design and connection: cylindrical external hexagon Ø3.30 mm (group 1), cylindrical internal hexagon Ø3.30 mm (group 2), conical internal hexagon Ø3.50 mm (group 3), and conical Morse taper Ø3.50 mm (group 4). Three insertion levels in resin were tested, 0 mm at the platform level (l1), 3 mm (l2), and 5 mm (l3) above the platform of the resin. All groups were subjected to quasi-static loading at 30° to the implant axis in a universal machine. RESULTS: The mean fracture strengths for group 1 were 1,991 N (l1), 1,020 N (l2), and 767 N (l3); for group 2: 2,119 N (l1), 1,034 N (l2), and 903 N (l3); for group 3: 2,373 N (l1), 1,407 N (l2), and 929 N (l3); and for group 4: 1,710 N (l1), 1,680 N (l2), and 1,182 N (l3). CONCLUSIONS: Resistance to loading decreases significantly with the loss of insertion, and the connection design between the implants and abutments can change the performance and resistance of the system. CLINICAL RELEVANCE: When implants are used in areas where there is a possibility of bone loss, the selection of a connection type is an important consideration for the longevity of the system.


Assuntos
Osso e Ossos/cirurgia , Implantes Dentários , Planejamento de Prótese Dentária , Humanos , Técnicas In Vitro
17.
Clin Oral Investig ; 18(7): 1749-55, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24398970

RESUMO

OBJECTIVE: The purpose of this study was to compare temperature variation during osteotomies with trephine drills under different irrigation conditions: without irrigation, external irrigation, and double irrigation. MATERIALS AND METHODS: Synthetic blocks of bone (type I density) were used for drilling procedures with an experimental computed machine, which measured the maximum temperature in the cortical bone during osteotomy with a bone cut that was 5 mm in both diameter and depth. Three groups were formed depending on the irrigation conditions: no irrigation (G1), external irrigation (G2), and double irrigation (G3). Fifty drillings were performed for each group. RESULTS: The average thermal increase in the groups was 21.7 ± 1.52 °C in G1, 14.2 ± 0.70 °C in G2, and 12.4 ± 0.75 °C in G3. The results presented statistically significant differences among all groups (α = 0.05). CONCLUSION: The double irrigation technique resulted in a smaller increase in temperature in the cortical bone model, demonstrating a greater efficiency, which may be beneficial when compared to external irrigation alone. CLINICAL RELEVANCE: The trephine has been widely used in removing small blocks for bone graft, especially the posterior mandible, where the possibility of heating may be higher due to the density of cortical bone in this area. So it is important that the professionals select instruments that can reduce the risks of complications in the proposed treatment.


Assuntos
Osteotomia/instrumentação , Irrigação Terapêutica , Condutividade Térmica , Humanos , Técnicas In Vitro , Instrumentos Cirúrgicos , Temperatura
18.
J Craniofac Surg ; 25(6): 2117-20, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25329842

RESUMO

OBJECTIVES: The objectives of the present study were to measure the implant stability quotient (ISQ) values at 3 different time points after the surgical insertion and to determine whether the time of osseointegration differs in the maxilla and mandible. MATERIALS AND METHODS: To measure implant stability, resonance frequency analysis (RFA) was performed in 44 patients (40 women, 4 men) with a total of 100 Implacil De Bortoli implants; the patients were divided into 2 groups: group 1, implants in the maxilla (22 in the anterior maxilla and 37 in the posterior maxilla); and group 2, implants in the mandible (41 posterior mandibles). Using RFA, implant stability was measured immediately after implant placement to assess the immediate stability (time 1) and at 90 (time 2) and 150 (time 3) days. RESULTS: Overall, the mean (SD) ISQ was 63.3 (6.63) (95% confidence interval [CI], 39-79) for time 1, 70.5 (6.32) (95% CI, 46-88) for time 2, and 73.5 (6.03) (95% CI, 58-88) for time 3. In group 1, the mean (SD) ISQ was 61.8 (6.56) (95% CI, 39-79) for time 1, 68.8 (5.19) (95% CI, 57-83) for time 2, and 72.3 (5.91) (95% CI, 58-85) for time 3. In group 2, the mean (SD) ISQ was 65.5 (6.13) (95% CI, 44-75) for time 1, 72.9 (7.02) (95% CI, 46-88) for time 2, and 75.3 (5.80) (95% CI, 60-88) for time 3. CONCLUSIONS: The stability of the implants placed in the maxilla and mandible showed a similar evolution in the ISQ values and, consequently, on osseointegration; however, the implants in the mandible presented superior values at all time points.


Assuntos
Implantes Dentários , Mandíbula/fisiologia , Maxila/fisiologia , Osseointegração/fisiologia , Adulto , Idoso , Aumento do Rebordo Alveolar/métodos , Implantação Dentária Endóssea/métodos , Planejamento de Prótese Dentária , Feminino , Seguimentos , Humanos , Masculino , Mandíbula/cirurgia , Maxila/cirurgia , Pessoa de Meia-Idade , Propriedades de Superfície , Retalhos Cirúrgicos/cirurgia , Taxa de Sobrevida , Alvéolo Dental/cirurgia , Vibração
19.
J Craniofac Surg ; 25(3): 1068-71, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24777027

RESUMO

OBJECTIVE: The proposal of this study was to use a photoelasticity method to analyze the stress dissipation in the bone surrounding an implant under simulated loading. MATERIALS AND METHODS: Four implant systems with different internal connection designs were studied: conical connection (group 1), triangular connection (group 2), Morse taper (group 3), and internal hexagon (group 4). After the models' inclusion in a photoelastic resin, they were subjected to static loads of 100, 150, and 200 N. The lengths of fringes that were generated were measured at the bone crest parallel to the neck of the implant and along the implant body, as well as the dissipation of force across the entire area of extension. RESULTS: Lower stress was observed at the crestal bone in groups 1 and 3 with no significant increase (P < 0.05) in different levels of load, whereas the stress levels in groups 2 and 4 were observed to be higher with loads of all intensities with significant differences from the other groups (P < 0.05). CONCLUSIONS: The type of connection and the implant neck design influenced the dissipation of force. The conical-type connection exhibited better load dissipation in the neck area, regardless of the load applied on the implant.


Assuntos
Projeto do Implante Dentário-Pivô , Implantes Dentários , Análise do Estresse Dentário/métodos , Estresse Mecânico , Humanos
20.
J Craniofac Surg ; 25(3): 863-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24820714

RESUMO

The aim of this study was to evaluate, through in vitro and in vivo studies, the existence of a relationship between surface energy, for wettability, and the clinical behavior of dental implants with different surfaces, one with a surface treated by sandblasting with titanium oxide microparticles followed by acid-etching treatment (experimental group) and another with a machined surface (control group). For the in vitro tests, a total of 30 titanium disks (15 disks for each group) were evaluated by scanning electron microscopy and dispersive energy spectroscopy and for surface roughness and wettability. For the in vivo tests, a total of 24 implants (12 implants for each group) were inserted in the tibiae of 6 rabbits and were removed after 30 and 60 days for histologic analysis. The results showed that the implants with the experimental surface presented a low wettability, and it also resulted in highly stimulated new bone formation in vivo, when compared with the control group dental implant. As for the bone formation, differences between the different surfaces seemed evident, both in quantity and in quality, as implants from the experimental group showed a higher new bone deposition than that from the control group. Thus, in vitro and in vivo tests demonstrated an excellent biologic response of the surfaces treated by sandblasting with microparticles of titanium oxide followed by acid etching.


Assuntos
Implantes Dentários , Propriedades de Superfície , Titânio , Animais , Calcificação Fisiológica/fisiologia , Corrosão Dentária/métodos , Polimento Dentário , Implantes Experimentais , Lasers de Estado Sólido , Microscopia Eletrônica de Varredura , Modelos Animais , Osseointegração/fisiologia , Coelhos , Tíbia/fisiologia , Tíbia/cirurgia , Molhabilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA