Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Neurophysiol ; 116(3): 1104-16, 2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27306672

RESUMO

In multichannel cochlear implants (CIs), current is delivered to specific electrodes along the cochlea in the form of amplitude-modulated pulse trains, to convey temporal and spectral cues. Our previous studies have shown that focused multipolar (FMP) and tripolar (TP) stimulation produce more restricted neural activation and reduced channel interactions in the inferior colliculus (IC) compared with traditional monopolar (MP) stimulation, suggesting that focusing of stimulation could produce better transmission of spectral information. The present study explored the capability of IC neurons to detect modulated CI stimulation with FMP and TP stimulation compared with MP stimulation. The study examined multiunit responses of IC neurons in acutely deafened guinea pigs by systematically varying the stimulation configuration, modulation depth, and stimulation level. Stimuli were sinusoidal amplitude-modulated pulse trains (carrier rate of 120 pulses/s). Modulation sensitivity was quantified by measuring modulation detection thresholds (MDTs), defined as the lowest modulation depth required to differentiate the response of a modulated stimulus from an unmodulated one. Whereas MP stimulation showed significantly lower MDTs than FMP and TP stimulation (P values <0.05) at stimulation ≤2 dB above threshold, all stimulation configurations were found to have similar modulation sensitivities at 4 dB above threshold. There was no difference found in modulation sensitivity between FMP and TP stimulation. The present study demonstrates that current focusing techniques such as FMP and TP can adequately convey amplitude modulation and are comparable to MP stimulation, especially at higher stimulation levels, although there may be some trade-off between spectral and temporal fidelity with current focusing stimulation.


Assuntos
Potenciais de Ação/fisiologia , Colículos Inferiores/citologia , Neurônios/fisiologia , Limiar Sensorial/fisiologia , Estimulação Acústica , Análise de Variância , Animais , Biofísica , Estimulação Elétrica , Feminino , Cobaias , Masculino , Psicoacústica
2.
STAR Protoc ; 2(3): 100637, 2021 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-34258597

RESUMO

Fluorescence recovery after photobleaching (FRAP) has been widely used to monitor membrane properties by measuring the lateral diffusion of fluorescent particles. This protocol describes how to perform two-photon FRAP on the stereocilia of live cochlear inner hair cells using a lipophilic dye, di-3-ANEPPDHQ, to assess the stereociliary membrane diffusivity. We also detail two-photon FRAP microscope setup and calibration, as well as FRAP parameter setting and data analysis. For complete details on the use and execution of this protocol, please refer to George et al. (2020).


Assuntos
Recuperação de Fluorescência Após Fotodegradação/métodos , Células Ciliadas Auditivas/metabolismo , Estereocílios/metabolismo , Animais , Corantes/metabolismo , Difusão , Fótons , Ratos
3.
iScience ; 23(12): 101773, 2020 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-33294782

RESUMO

The lipid bilayer plays a pivotal role in force transmission to many mechanically-gated channels. We developed the technology to monitor membrane diffusivity in order to test the hypothesis positing that Ca2+ regulates open probability (P o) of cochlear hair cell mechanotransduction (MET) channels via the plasma membrane. The stereociliary membrane was more diffusive (9x) than the basolateral membrane. Elevating intracellular Ca2+ buffering or lowering extracellular Ca2+ reduced stereociliary diffusivity and increased MET P o. In contrast, prolonged depolarization increased stereociliary diffusivity and reduced MET P o. No comparable effects were noted for soma measurements. Although MET channels are located in the shorter stereocilia rows, both rows had similar baseline diffusivity and showed similar responses to Ca2+ manipulations and MET channel blocks, suggesting that diffusivity is independent of MET. Together, these data suggest that the stereociliary membrane is a component of a calcium-modulated viscoelastic-like element regulating hair cell mechanotransduction.

4.
J Neural Eng ; 12(6): 066005, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26401834

RESUMO

OBJECTIVE: Speech intelligibility with existing multichannel cochlear implants (CIs) is thought to be limited by poor spatial selectivity and interactions between CI channels caused by overlapping activation with monopolar (MP) stimulation. Our previous studies have shown that focused multipolar (FMP) and tripolar (TP) stimulation produce more restricted neural activation in the inferior colliculus (IC), compared to MP stimulation. APPROACH: This study explored interactions in the IC produced by simultaneous stimulation of two CI channels. We recorded multi-unit neural activity in the IC of anaesthetized cats with normal and severely degenerated spiral ganglion neuron populations in response to FMP, TP and MP stimulation from a 14 channel CI. Stimuli were applied to a 'fixed' CI channel, chosen toward the middle of the cochlear electrode array, and the effects of simultaneously stimulating a more apical 'test' CI channel were measured as a function of spatial separation between the two stimulation channels and stimulus level of the fixed channel. Channel interactions were quantified by changes in neural responses and IC threshold (i.e., threshold shift) elicited by simultaneous stimulation of two CI channels, compared to stimulation of the test channel alone. MAIN RESULTS: Channel interactions were significantly lower for FMP and TP than for MP stimulation (p < 0.001), whereas no significant difference was observed between FMP and TP stimulation. With MP stimulation, threshold shifts increased with decreased inter-electrode spacing and increased stimulus levels of the fixed channel. For FMP and TP stimulation, channel interactions were found to be similar for different inter-electrode spacing and stimulus levels of the fixed channel. SIGNIFICANCE: The present study demonstrates how the degree of channel interactions in a CI can be controlled using stimulation configurations such as FMP and TP; such knowledge is essential in enhancing CI function in complex acoustic environments.


Assuntos
Estimulação Acústica/métodos , Limiar Auditivo/fisiologia , Implante Coclear/métodos , Implantes Cocleares , Surdez/cirurgia , Animais , Gatos , Surdez/fisiopatologia , Estimulação Elétrica/métodos , Fenômenos Eletrofisiológicos/fisiologia
5.
J Neural Eng ; 12(3): 036003, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25834113

RESUMO

OBJECTIVE: Focused multipolar (FMP) stimulation has been shown to produce restricted neural activation using intracochlear stimulation in animals with a normal population of spiral ganglion neurons (SGNs). However, in a clinical setting, the widespread loss of SGNs and peripheral fibres following deafness is expected to influence the effectiveness of FMP. APPROACH: We compared the efficacy of FMP stimulation to both monopolar (MP) and tripolar (TP) stimulation in long-term deafened cat cochleae (n = 8). Unlike our previous study, these cochleae contained <10% of the normal SGN population adjacent to the electrode array. We also evaluated the effect of electrode position on stimulation modes by using either modiolar facing or lateral wall facing half-band electrodes. The spread of neural activity across the inferior colliculus, a major nucleus within the central auditory pathway, was used as a measure of spatial selectivity. MAIN RESULTS: In cochleae with significant SGN degeneration, we observed that FMP and TP stimulation resulted in greater spatial selectivity than MP stimulation (p < 0.001). However, thresholds were significantly higher for FMP and TP stimulation compared to MP stimulation (p < 0.001). No difference between FMP and TP stimulation was found in any measures. The high threshold levels for FMP stimulation was significantly reduced without compromising spatial selectivity by varying the degree of current focusing (referred as 'partial-FMP' stimulation). Spatial selectivity of all stimulation modes was unaffected by the electrode position. Finally, spatial selectivity in long-term deafened cochleae was significantly less than that of cochleae with normal SGN population (George S S et al 2014 J. Neural Eng. 11 065003). SIGNIFICANCE: The present results indicate that the greater spatial selectivity of FMP and TP stimulation over MP stimulation is maintained in cochleae with significant neural degeneration and is not adversely affected by electrode position. The greater spatial selectivity of FMP and TP stimulation would be expected to result in improved clinical performance.


Assuntos
Implantes Cocleares , Surdez/fisiopatologia , Surdez/reabilitação , Terapia por Estimulação Elétrica/instrumentação , Audição , Gânglio Espiral da Cóclea/fisiopatologia , Animais , Gatos , Doença Crônica , Surdez/diagnóstico , Terapia por Estimulação Elétrica/métodos , Análise de Falha de Equipamento , Desenho de Prótese , Resultado do Tratamento
6.
J Neural Eng ; 11(6): 065003, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25420148

RESUMO

OBJECTIVE: The conductive nature of the fluids and tissues of the cochlea can lead to broad activation of spiral ganglion neurons using contemporary cochlear implant stimulation configurations such as monopolar (MP) stimulation. The relatively poor spatial selectivity is thought to limit implant performance, particularly in noisy environments. Several current focusing techniques have been proposed to reduce the spread of activation with the aim towards achieving improved clinical performance. APPROACH: The present research evaluated the efficacy of focused multipolar (FMP) stimulation, a relatively new focusing technique in the cochlea, and compared its efficacy to both MP stimulation and tripolar (TP) stimulation. The spread of neural activity across the inferior colliculus (IC), measured by recording the spatial tuning curve, was used as a measure of spatial selectivity. Adult cats (n = 6) were acutely deafened and implanted with an intracochlear electrode array before multi-unit responses were recorded across the cochleotopic gradient of the contralateral IC. Recordings were made in response to acoustic and electrical stimulation using the MP, TP and FMP configurations. MAIN RESULTS: FMP and TP stimulation resulted in greater spatial selectivity than MP stimulation. However, thresholds were significantly higher (p < 0.001) for FMP and TP stimulation compared to MP stimulation. There were no differences found in spatial selectivity and threshold between FMP and TP stimulation. SIGNIFICANCE: The greater spatial selectivity of FMP and TP stimulation would be expected to result in improved clinical performance. However, further research will be required to demonstrate the efficacy of these modes of stimulation after longer durations of deafness.


Assuntos
Estimulação Acústica/normas , Implante Coclear/normas , Implantes Cocleares/normas , Surdez/cirurgia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Estimulação Acústica/métodos , Doença Aguda , Animais , Gatos , Implante Coclear/métodos , Surdez/diagnóstico , Estimulação Elétrica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA