Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nano Lett ; 24(7): 2282-2288, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38345381

RESUMO

The rapid development of infrared spectroscopy, observational astronomy, and scanning near-field microscopy has been enabled by the emergence of sensitive mid- and far-infrared photodetectors. Superconducting hot-electron bolometers (HEBs), known for their exceptional signal-to-noise ratio and fast photoresponse, play a crucial role in these applications. While superconducting HEBs are traditionally crafted from sputtered thin films such as NbN, the potential of layered van der Waals (vdW) superconductors is untapped at THz frequencies. Here, we introduce superconducting HEBs made from few-layer NbSe2 microwires. By improving the interface between NbSe2 and metal leads, we overcome impedance mismatch with RF readout, enabling large responsivity THz detection (0.13 to 2.5 THz) with a minimal noise equivalent power of 7 pW/ Hz and nanosecond-range response time. Our work highlights NbSe2 as a promising platform for HEB technology and presents a reliable vdW assembly protocol for custom bolometer production.

2.
Anal Chem ; 94(42): 14517-14521, 2022 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-36219070

RESUMO

An elaboration of the photonic based sensors is the most promising direction in modern analytical chemistry from the point of view of real clinical applications. The highest sensitivity is demonstrated by sensors based on photonic integrated circuits (PICs). This type of sensor has been recently successfully combined with microfluidics, which decreased the analyte volume for analysis down to microliter units. The most significant disadvantage regarding these photonic sensors is low specificity. One of the methods that could be useful for such type of problem is the layer by layer (LBL) assembly. The peculiarity of a PIC based sensor is the ability to precisely control surface modification by using measurements of a minimum resonance position shift. The bovine serum albumin (BSA) and tannic acid (TA) molecules were selected for LBL assembly because on one side they form a stable LBL assembly film based on hydrogen bonds, while the other side of both TA and BSA molecules can be used for conjugation with target molecules. A microring resonator (MRR) and a Mach-Zehnder interferometer (MZI) based on a silicon nitride platform combined with a microfluidic system were elaborated and used for monitoring the LBL film assembly. Obtained results have a good correlation with measurements carried out by atom force microscopy. Thus, the ability of using PIC based sensors for in situ control of surface modification was demonstrated and can be considered in point-of-care (POC) devices that have a very good perspective for both early pathological state diagnosis and evaluation of treatment efficiency.


Assuntos
Microfluídica , Soroalbumina Bovina , Soroalbumina Bovina/química , Fótons , Microscopia de Força Atômica , Taninos/química
3.
Opt Lett ; 47(9): 2358-2361, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35486799

RESUMO

Today, a lab-on-a-chip is one of the most promising ways to create sensor devices for gas and liquid analysis for environmental monitoring, early diagnosis, and treatment effectiveness assessment. On the one hand, this requires a large number of measurements and, on the other hand, involves minimum consumption of the test analytes. Combination of highly sensitive photonic integrated circuits (PICs) with microfluidic channels (MFCs) is necessary to solve this problem. In this work, PICs based on a silicon nitride platform integrated with MFCs for studying liquids and gases were developed. Different concentrations of isopropanol in de-ionized water were used as the analyte. Based on this, the sensitivity (S) and detection limit (DL) of the analyzed solution were evaluated. Entire system calibration was carried out to calculate S and DL, considering experimental and numerical simulation data. This development may be of interest as a promising platform for environmental monitoring and realization of point-of-care strategy for biomedical applications.


Assuntos
Gases , Microfluídica , Simulação por Computador , Dispositivos Lab-On-A-Chip , Fótons
4.
Opt Express ; 27(21): 30979-30988, 2019 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-31684339

RESUMO

We present an active anti-latching system for superconducting nanowire single-photon detectors. We experimentally test it against a bright-light attack, previously used to compromise security of quantum key distribution. Although our system detects continuous blinding, the detector is shown to be partially blindable and controllable by specially tailored sequences of bright pulses. Improvements to the countermeasure are suggested.

5.
Nano Lett ; 16(11): 7085-7092, 2016 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-27759401

RESUMO

Ultrafast single-photon detectors with high efficiency are of utmost importance for many applications in the context of integrated quantum photonic circuits. Detectors based on superconductor nanowires attached to optical waveguides are particularly appealing for this purpose. However, their speed is limited because the required high absorption efficiency necessitates long nanowires deposited on top of the waveguide. This enhances the kinetic inductance and makes the detectors slow. Here, we solve this problem by aligning the nanowire, contrary to usual choice, perpendicular to the waveguide to realize devices with a length below 1 µm. By integrating the nanowire into a photonic crystal cavity, we recover high absorption efficiency, thus enhancing the detection efficiency by more than an order of magnitude. Our cavity enhanced superconducting nanowire detectors are fully embedded in silicon nanophotonic circuits and efficiently detect single photons at telecom wavelengths. The detectors possess subnanosecond decay (∼120 ps) and recovery times (∼510 ps) and thus show potential for GHz count rates at low timing jitter (∼32 ps). The small absorption volume allows efficient threshold multiphoton detection.

6.
ACS Appl Mater Interfaces ; 16(29): 38345-38354, 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39010705

RESUMO

Formation of laser-induced periodic surface structures (LIPSS) is known as a fast and robust method of functionalization of material surfaces. Of particular interest are LIPSS that manifest as periodic modulation of phase state of the material, as it implies reversibility of phase modification that constitute rewritable LIPSS, and recently was demonstrated for chalcogenide phase change materials (PCMs). Due to remarkable properties of chalcogenide PCMs─nonvolatality, prominent optical contrast and ns switching speed─such novel phase change LIPSS hold potential for exciting applications in all-optical tunable photonics. In this work we explore phase change LIPSS formation in thin films of Ge2Sb2Te5 (GST) integrated with planar and rib waveguides. We demonstrate that by fine-tuning laser radiation, the morphology of phase change LIPSS can be controlled, including their period and fill factor, and investigate the limitations of multicycle rewriting of the structures. We also demonstrate the formation of phase change LIPSS on a 1D waveguide, which has potential for use as tunable Bragg filters or structures for on-demand light decoupling into the far-field. The presented concept of applying phase change LIPSS offers a promising approach to enable fast and simple tuning in integrated photonic devices.

7.
Chem Commun (Camb) ; 60(23): 3182-3185, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38411614

RESUMO

In this study, Pt(0) microscrolls are synthesized on polished Ni via galvanic replacement reaction (GRR). Employing in situ optical microscopy, the dynamic motion of the catalytic microscrolls as micromotors in H2O2 solutions is revealed. This method offers a rapid fabrication of scrolls from diverse noble metals and alloys.

8.
Nanoscale ; 16(37): 17365-17370, 2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-39257228

RESUMO

Optofluidics is a new field of modern science that stands at the interface of microfluidics and photonics and has good prospects for application in gas sensors. Microfluidics offers a promising platform for tuning and assembling monolayer structures that are used as sensitive layers for gas detection. Herein, we evaluate the concept of monolayer formation on a silicon nitride substrate enabling a surface coverage up to 59% through a microfluidic convective assembly and couple it with a photonic integrated chip to probe gas sensing performance.

9.
Nanomaterials (Basel) ; 13(16)2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37630892

RESUMO

The integration of low-dimensional materials with optical waveguides presents promising opportunities for enhancing light manipulation in passive photonic circuits. In this study, we investigate the potential of aerosol-synthesized single-walled carbon nanotube (SWCNT) films for silicon nitride photonic circuits as a basis for developing integrated optics devices. Specifically, by measuring the optical response of SWCNT-covered waveguides, we retrieve the main SWCNT film parameters, such as absorption, nonlinear refractive, and thermo-optic coefficients, and we demonstrate the enhancement of all-optical wavelength conversion and the photoresponse with a 1.2 GHz bandwidth.

10.
Materials (Basel) ; 15(23)2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-36499879

RESUMO

Polycrystalline PbTe:In films on a polyimide substrate were obtained and investigated. Their structural and transport properties in a wide range of temperatures (10-300 K) were studied. The unique feature of In impurity in PbTe is the stabilization of the Fermi level (pinning effect) that allowed for the preparation polycrystalline films with the same carrier concentration. We found that heat treatment in an argon atmosphere does not change the average grain size and carrier concentration for as-grown films but greatly increases the Hall mobility and the electron mean free path. By comparing the mobility in the bulk and in the film after heat treatment, we extracted the value of the mobility that arises due to scattering at the grain boundary barriers. The ultimate goal of the present study is the development of these films in designing portable uncooled photodetectors for the mid-IR range.

11.
Nanomaterials (Basel) ; 13(1)2022 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-36615990

RESUMO

Spectrometers are widely used tools in chemical and biological sensing, material analysis, and light source characterization. However, an important characteristic of traditional spectrometers for biomedical applications is stable operation. It can be achieved due to high fabrication control during the development and stabilization of temperature and polarization of optical radiation during measurements. Temperature and polarization stabilization can be achieved through on-chip technology, and in turn robustness against fabrication imperfections through sensor design. Here, for the first time, we introduce a robust sensor based on a combination of nanophotonic random spectrometer and microfluidics (NRSM) for determining ultra-low concentrations of analyte in a solution. In order to study the sensor, we measure and analyze the spectra of different isopropanol solutions of known refractive indexes. Simple correlation analysis shows that the measured spectra shift with a tiny variation of the ambient liquid optical properties reaches a sensitivity of approximately 61.8 ± 2.3 nm/RIU. Robustness against fabrication imperfections leads to great scalability on a chip and the ability to operate in a huge spectral range from VIS to mid-IR. NRSM optical sensors are very promising for fast and efficient functionalization in the field of selective capture fluorescence-free oncological disease for liquid/gas biopsy in on-chip theranostics applications.

12.
J Biomed Opt ; 26(4)2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33834684

RESUMO

SIGNIFICANCE: Water content plays a vital role in the normally functioning visual system; even a minor disruption in the water balance may be harmful. Today, no direct method exists for corneal hydration assessment, while it could be instrumental in early diagnosis and control of a variety of eye diseases. The use of terahertz (THz) radiation, which is highly sensitive to water content, appears to be very promising. AIM: To find out how THz scanning parameters of corneal tissue measured by an experimental setup, specially developed for in vivo contactless estimations of corneal reflectivity coefficient (RC), are related to pathological changes in the cornea caused by B-band ultraviolet (UVB) exposure. APPROACH: The setup was tested on rabbit eyes in vivo. Prior to the course of UVB irradiation and 1, 5, and 30 days after it, a series of examinations of the corneal state was made. At the same time points, corneal hydration was assessed by measuring RC. RESULTS: The obtained data confirmed the negative impact of UVB irradiation course on the intensity of tear production and on the corneal thickness and optical parameters. A significant (1.8 times) increase in RC on the 5th day after the irradiation course, followed by a slight decrease on the 30th day after it was revealed. The RC increase measured 5 days after the UVB irradiation course generally corresponded to the increase (by a factor of 1.3) of tear production. RC increase occurred with the corneal edema, which was manifested by corneal thickening (by 18.2% in the middle area and 17.6% in corneal periphery) and an increased volume of corneal tissue (by 17.6%). CONCLUSIONS: Our results demonstrate that the proposed approach can be used for in vivo contactless estimation of the reflectivity of rabbit cornea in the THz range and, thereby, of cornea hydration.


Assuntos
Córnea , Raios Ultravioleta , Animais , Córnea/diagnóstico por imagem , Coelhos , Radiação Terahertz , Raios Ultravioleta/efeitos adversos , Visão Ocular
13.
Nanomaterials (Basel) ; 10(5)2020 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-32365694

RESUMO

In the 20th century, microelectronics was revolutionized by silicon-its semiconducting properties finally made it possible to reduce the size of electronic components to a few nanometers. The ability to control the semiconducting properties of Si on the nanometer scale promises a breakthrough in the development of Si-based technologies. In this paper, we present the results of our experimental studies of the photovoltaic effect in Ag2S QD/Si heterostructures in the short-wave infrared range. At room temperature, the Ag2S/Si heterostructures offer a noise-equivalent power of 1.1 × 10-10 W/√Hz. The spectral analysis of the photoresponse of the Ag2S/Si heterostructures has made it possible to identify two main mechanisms behind it: the absorption of IR radiation by defects in the crystalline structure of the Ag2S QDs or by quantum QD-induced surface states in Si. This study has demonstrated an effective and low-cost way to create a sensitive room temperature SWIR photodetector which would be compatible with the Si complementary metal oxide semiconductor technology.

14.
Appl Opt ; 48(20): 4009-17, 2009 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-19593355

RESUMO

Coherence-domain imaging systems can be operated in a single-photon-counting mode, offering low detector noise; this in turn leads to increased sensitivity for weak light sources and weakly reflecting samples. We have demonstrated that excellent axial resolution can be obtained in a photon-counting coherence-domain imaging (CDI) system that uses light generated via spontaneous parametric downconversion (SPDC) in a chirped periodically poled stoichiometric lithium tantalate (chirped-PPSLT) structure, in conjunction with a niobium nitride superconducting single-photon detector (SSPD). The bandwidth of the light generated via SPDC, as well as the bandwidth over which the SSPD is sensitive, can extend over a wavelength region that stretches from 700 to 1500 nm. This ultrabroad wavelength band offers a near-ideal combination of deep penetration and ultrahigh axial resolution for the imaging of biological tissue. The generation of SPDC light of adjustable bandwidth in the vicinity of 1064 nm, via the use of chirped-PPSLT structures, had not been previously achieved. To demonstrate the usefulness of this technique, we construct images for a hierarchy of samples of increasing complexity: a mirror, a nitrocellulose membrane, and a biological sample comprising onion-skin cells.


Assuntos
Aumento da Imagem/instrumentação , Fotometria/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Tomografia de Coerência Óptica/instrumentação , Transdutores , Condutividade Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Fótons
15.
Opt Express ; 16(19): 15104-8, 2008 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-18795048

RESUMO

We generate ultrabroadband biphotons via the process of spontaneous parametric down-conversion in a quasi-phase-matched nonlinear grating that has a linearly chirped poling period. Using these biphotons in conjunction with superconducting single-photon detectors (SSPDs), we measure the narrowest Hong-Ou-Mandel dip to date in a two-photon interferometer, having a full width at half maximum (FWHM) of approximately 5.7 fsec. This FWHM corresponds to a quantum optical coherence tomography (QOCT) axial resolution of 0.85 ?m. Our results indicate that a high flux of nonoverlapping biphotons may be generated, as required in many applications of nonclassical light.


Assuntos
Desenho Assistido por Computador , Interferometria/instrumentação , Modelos Teóricos , Simulação por Computador , Condutividade Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Fótons
16.
Nat Commun ; 9(1): 5392, 2018 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-30568184

RESUMO

Plasmons, collective oscillations of electron systems, can efficiently couple light and electric current, and thus can be used to create sub-wavelength photodetectors, radiation mixers, and on-chip spectrometers. Despite considerable effort, it has proven challenging to implement plasmonic devices operating at terahertz frequencies. The material capable to meet this challenge is graphene as it supports long-lived electrically tunable plasmons. Here we demonstrate plasmon-assisted resonant detection of terahertz radiation by antenna-coupled graphene transistors that act as both plasmonic Fabry-Perot cavities and rectifying elements. By varying the plasmon velocity using gate voltage, we tune our detectors between multiple resonant modes and exploit this functionality to measure plasmon wavelength and lifetime in bilayer graphene as well as to probe collective modes in its moiré minibands. Our devices offer a convenient tool for further plasmonic research that is often exceedingly difficult under non-ambient conditions (e.g. cryogenic temperatures) and promise a viable route for various photonic applications.

17.
Beilstein J Nanotechnol ; 8: 38-44, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28144563

RESUMO

Carbon nanotubes (CNTs) have recently been integrated into optical waveguides and operated as electrically-driven light emitters under constant electrical bias. Such devices are of interest for the conversion of fast electrical signals into optical ones within a nanophotonic circuit. Here, we demonstrate that waveguide-integrated single-walled CNTs are promising high-speed transducers for light-pulse generation in the gigahertz range. Using a scalable fabrication approach we realize hybrid CNT-based nanophotonic devices, which generate optical pulse trains in the range from 200 kHz to 2 GHz with decay times below 80 ps. Our results illustrate the potential of CNTs for hybrid optoelectronic systems and nanoscale on-chip light sources.

18.
J Biomed Opt ; 21(9): 97002, 2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27626901

RESUMO

An adequate water balance (hydration extent) is one of the basic factors of normal eye function, including its external shells: the cornea and the sclera. Adequate control of corneal and scleral hydration is very important for early diagnosis of a variety of eye diseases, stating indications for and contraindications against keratorefractive surgeries and the choice of contact lens correction solutions. THz systems of creating images in reflected beams are likely to become ideal instruments of noninvasive control of corneal and scleral hydration degrees. This paper reports on the results of a study involving transmittance and reflectance spectra for the cornea and the sclera of rabbit and human eyes, as well as those of the rabbit eye, in the frequency range of 0.13 to 0.32 THz. The dependence of the reflectance coefficient of these tissues on water mass percentage content was determined. The experiments were performed on three corneas, three rabbit scleras, two rabbit eyes, and three human scleras. The preliminary results demonstrate that the proposed technique, based on the use of a continuous THz radiation, may be utilized to create a device for noninvasive control of corneal and scleral hydration, which has clear potential of broad practical application.


Assuntos
Córnea/diagnóstico por imagem , Esclera/diagnóstico por imagem , Imagem Terahertz/métodos , Animais , Córnea/fisiologia , Desenho de Equipamento , Humanos , Coelhos , Esclera/fisiologia , Imagem Terahertz/instrumentação
19.
Sci Rep ; 5: 10941, 2015 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-26061283

RESUMO

Superconducting nanowire single-photon detectors (SNSPDs) provide high efficiency for detecting individual photons while keeping dark counts and timing jitter minimal. Besides superior detection performance over a broad optical bandwidth, compatibility with an integrated optical platform is a crucial requirement for applications in emerging quantum photonic technologies. Here we present SNSPDs embedded in nanophotonic integrated circuits which achieve internal quantum efficiencies close to unity at 1550 nm wavelength. This allows for the SNSPDs to be operated at bias currents far below the critical current where unwanted dark count events reach milli-Hz levels while on-chip detection efficiencies above 70% are maintained. The measured dark count rates correspond to noise-equivalent powers in the 10(-19) W/Hz(-1/2) range and the timing jitter is as low as 35 ps. Our detectors are fully scalable and interface directly with waveguide-based optical platforms.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA