Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Radiol Prot ; 42(3)2022 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-36067741

RESUMO

90Y radioembolisation (RE) is an angiographic procedure used in patients with both primary and secondary hepatic malignancies. Local tumour control can be achieved by short range tumour irradiation by the regional intra-arterial administration of glass or resin microspheres loaded with 90yttrium that accumulate in the tumorous tissue. The aim of this study was to investigate the radiation exposure of RE and to establish a local diagnostic reference level (DRL). In this retrospective study, dose data from 397 procedures in 306 patients (mean age 67.4 ± 10.6 years, 82 female) who underwent RE between 06/2017 and 01/2022 using one of two different angiography systems were analysed. DRL was set as the 75th percentile of the dose distribution. In the overall population, dose area product (DAP) (median (interquartile range, IQR)) was 26 Gy cm2(IQR 12-50) with a median fluoroscopy time (FT) of 4.5 min (IQR 2.9-8.0). FT and DAP increased significantly with the number of infusion positions (median, IQR): one position 23 Gy cm2(12-46), two positions 33 Gy cm2(14-60), three positions 50 Gy cm2(24-82) (p< 0.0001). Local DRL is 47 Gy cm2for RE and 111 Gy cm2for RE with additional embolisation. Radiation exposure and FT are significantly higher with increasing number of infusion positions as well as additional embolisation. Our established DRLs for RE may serve as a benchmark for dose optimisation.


Assuntos
Angiografia , Níveis de Referência de Diagnóstico , Idoso , Feminino , Fluoroscopia , Humanos , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos
2.
Eur J Nucl Med Mol Imaging ; 45(8): 1382-1393, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29455313

RESUMO

PURPOSE: To evaluate the diagnostic performance of integrated whole-body positron emission tomography (PET)/magnetic resonance (MR) enterography in patients with Crohn's disease (CD). METHODS: Fifty patients with known CD and recurrent symptoms underwent ileocolonoscopy (reference standard) as well as PET/MR enterography. Seven ileocolonic segments were endoscopically analysed using the Simplified Endoscopic Activity Score for Crohn's Disease (SES-CD) and additionally classified into three categories of inflammation (none, mild to moderate and severe ulcerative inflammation). A total of 14 PET/MR parameters were applied for the assessment of inflamed segments. Contingency tables and the chi-squared test were used for the analysis of qualitative parameters, and the Mann-Whitney U test and receiver operating characteristic (ROC) curve for the analysis of quantitative parameters. The PET/MR parameters were ranked according to their diagnostic value by random forest classification. Correlations between PET/MR parameters and the severity of inflammation on endoscopy and SES-CD were tested using Spearman's rank correlation test. RESULTS: A total of 309 segments could be analysed. Based on multivariate regression analysis, wall thickness and the comb sign were the most important parameters for predicting segments with active inflammation of any type. SUVmax ratio of the bowel segment (relative to SUVmax of the liver) was the most important parameter for detecting segments with severe ulcerative inflammation. Wall thickness was the only parameter that moderately correlated with inflammation severity on endoscopy as well as with SES-CD (ρ = 0.56 and 0.589, both p < 0.001). CONCLUSION: PET/MR enterography is an excellent noninvasive diagnostic method, and both MR parameters and PET findings provided high accuracy in detecting inflamed segments.


Assuntos
Doença de Crohn/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Fluordesoxiglucose F18 , Humanos , Inflamação , Estudos Prospectivos
3.
Eur J Nucl Med Mol Imaging ; 43(9): 1646-52, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26969347

RESUMO

PURPOSE: The aim of this study was to evaluate integrated (18)F-FDG PET/MRI as a one-stop diagnostic procedure in the assessment of (active) idiopathic retroperitoneal fibrosis (RPF) METHODS: A total of 22 examinations comprising a PET/CT scan followed by a PET/MRI scan in 17 patients (13 men, 4 women, age 58 ± 11 years) with histopathologically confirmed RPF at diagnosis or during follow-up under steroid therapy were analysed in correlation with laboratory inflammation markers (ESR, CRP). The patient cohort was subdivided into two groups: 6 examinations in untreated and 16 in treated patients. Tissue formations in typically periaortic localization suggestive of RPF were visually and quantitatively evaluated. The PET analysis included the assessment of SUVmax and a qualitative score for FDG uptake in RPF tissue in relation to the uptake in the liver. MRI analysis included evaluation of the T2-weighted image signal intensity, contrast enhancement and diffusion restriction (ADC values). Mean values were compared using the Mann-Whitney U test. ADC, SUVmax and ESR values were correlated using Pearson's correlation. RESULTS: MRI analysis revealed restricted diffusion in 100 % and 56 %, hyperintense T2 signal in 100 % and 31 %, and contrast enhancement in the periaortic tissue formation suggestive of RPF in 100 % and 62.5 % in the untreated and treated patients, respectively. In the qualitative and quantitative PET analysis, statistically significant differences were found for mean FDG uptake scores (2.5 ± 0.8 in untreated patients and 1.1 ± 0.9 in treated patients) and mean SUVmax (7.8 ± 3.5 and 4.1 ± 2.2, respectively). A strong correlation was found between the ADC values and SUVmax (Pearson r -0.65, P = 0.0019), and between ESR and CRP values and SUVmax (both r = 0.45, P = 0.061). CONCLUSION: Integrated (18)F-FDG PET/MRI shows high diagnostic potential as a one-stop diagnostic procedure for the assessment of (active) RPF providing multiparametric supportive information.


Assuntos
Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Fibrose Retroperitoneal/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrose Retroperitoneal/terapia
4.
Br J Radiol ; 97(1154): 430-438, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38308031

RESUMO

OBJECTIVES: Malignant triton tumours (MTTs) are rare but aggressive subtypes of malignant peripheral nerve sheath tumours (MPNSTs) with a high recurrence rate and 5-year survival of 14%. Systematic imaging data on MTTs are scarce and mainly based on single case reports. Therefore, we aimed to identify typical CT and MRI features to improve early diagnosis rates of this uncommon entity. METHODS: A systematic review on literature published until December 2022 on imaging characteristics of MTTs was performed. Based on that, we conducted a retrospective, monocentric analysis of patients with histopathologically proven MTTs from our department. Explorative data analysis was performed. RESULTS: Initially, 29 studies on 34 patients (31.42 ± 22.6 years, 12 female) were evaluated: Literature described primary MTTs as huge, lobulated tumours (108 ± 99.3 mm) with central necrosis (56% [19/34]), low T1w (81% [17/21]), high T2w signal (90% [19/21]) and inhomogeneous enhancement on MRI (54% [7/13]). Analysis of 16 patients (48.9 ± 13.8 years; 9 female) from our institution revealed comparable results: primary MTTs showed large, lobulated masses (118 mm ± 64.9) with necrotic areas (92% [11/12]). MRI revealed low T1w (100% [7/7]), high T2w signal (100% [7/7]) and inhomogeneous enhancement (86% [6/7]). Local recurrences and soft-tissue metastases mimicked these features, while nonsoft-tissue metastases appeared unspecific. CONCLUSIONS: MTTs show characteristic features on CT and MRI. However, these do not allow a reliable differentiation between MTTs and other MPNSTs based on imaging alone. Therefore, additional histopathological analysis is required. ADVANCES IN KNOWLEDGE: This largest published systematic analysis on MTT imaging revealed typical but unspecific imaging features that do not allow a reliable, imaging-based differentiation between MTTs and other MPNSTs. Hence, additional histopathological analysis remains essential.


Assuntos
Neoplasias de Bainha Neural , Neurofibrossarcoma , Neoplasias Cutâneas , Neoplasias de Tecidos Moles , Feminino , Humanos , Imageamento por Ressonância Magnética , Neoplasias de Bainha Neural/diagnóstico por imagem , Neurofibrossarcoma/complicações , Neurofibrossarcoma/patologia , Estudos Retrospectivos , Neoplasias de Tecidos Moles/diagnóstico por imagem , Tomografia Computadorizada por Raios X
5.
Eur Radiol ; 23(9): 2364-73, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23645332

RESUMO

OBJECTIVES: The aim of this study was to investigate the feasibility of 7-T contrast-enhanced MR imaging of the female pelvis. METHODS: Ten healthy female volunteers were examined on a 7-T whole-body MR system utilising a custom-built eight-channel transmit/receive radiofrequency body coil. The examination protocol included (1) T1-weighted fat-saturated 2D spoiled gradient echo (FLASH), (2) dynamic T1-weighted fat-saturated 3D FLASH, and (3) T2-weighted TSE sequences. For qualitative image analysis pelvic anatomy, uterine zonal anatomy and image impairment due to artefacts was assessed using a five-point scale. For quantitative analysis contrast ratios between the junctional zone and myometrium were obtained for T2-weighted MRI. RESULTS: Two-dimensional FLASH MRI offered the best overall image quality (meancontrast-enhanced 4.9) and highest tissue contrast (meancontrast-enhanced 4.7). T2-weighted TSE imaging provided a moderate to high conspicuity of the uterine zonal anatomy with mean scores ranging from 3.5 for endometrium to 4.65 for myometrium. Overall image impairment was rated strongest for T2-weighted MRI (2.9) and least for 2D FLASH MRI (mean 4.2). CONCLUSION: This study demonstrated the feasibility of 7-T T1-weighted MRI of the female pelvis and current constraints associated with T2-weighted MRI. KEY POINTS: • Dynamic contrast-enhanced female pelvis MR imaging at 7 T is feasible. • Unenhanced T1-weighted MRI offers inherent hyperintense delineation of pelvic arterial vasculature. • Two-dimensional FLASH MRI provided best overall image quality and least artefact impairment.


Assuntos
Imageamento por Ressonância Magnética/métodos , Pelve/patologia , Adulto , Artefatos , Gráficos por Computador , Meios de Contraste/farmacologia , Desenho de Equipamento , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Movimento (Física) , Reprodutibilidade dos Testes , Interface Usuário-Computador
6.
Clin Imaging ; 42: 198-202, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28110202

RESUMO

PURPOSE: To evaluate integrated PET/MRI/1H MR spectroscopy in patients with prostate cancer. SUBJECTS AND METHODS: Data analysis comprised calculations of correlations of standardized uptake values (SUVs) and ratios of (choline+creatine)/citrate as well as of single metabolite values and a logistic regression analysis of PET data and MR spectroscopy data in 22 patients. RESULTS: SUVmean and integral values of choline correlated significantly in tumors. Logistic regression analysis demonstrated diagnostic superiority of PET over spectroscopy. CONCLUSION: Simultaneous acquisition of PET and MR spectroscopy with integrated PET/MRI is feasible. Choline compounds and choline metabolism show a positive significant correlation.


Assuntos
Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Colina/análogos & derivados , Creatina , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/patologia
7.
PLoS One ; 12(7): e0180349, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28683109

RESUMO

OBJECTIVES: To evaluate the added value of the application of the liver-specific contrast phase of Gadobenate dimeglumine (Gd-BOPTA) for detection and characterization of liver lesions in 18F-FDG PET/MRI. METHODS: 41 patients with histologically confirmed solid tumors and known / suspected liver metastases or not classifiable lesions in 18F-FDG PET/CT were included in this study. All patients underwent a subsequent Gd-BOPTA enhanced 18F-FDG PET/MRI examination. MRI without liver-specific contrast phase (MRI1), MRI with liver-specific contrast phase (MRI2), 18F-FDG PET/MRI without liver-specific contrast phase (PET/MRI1) and with liver-specific contrast phase (PET/MRI2) were separately evaluated for suspect lesions regarding lesion dignity, characterization, conspicuity and confidence. RESULTS: PET/MRI datasets enabled correct identification of 18/18 patients with malignant lesions; MRI datasets correctly identified 17/18 patients. On a lesion-based analysis PET/MRI2 provided highest accuracy for differentiation of lesions into malignant and benign lesions of 98% and 100%. Respective values were 95% and 100% for PET/MRI1, 93% and 96% for MRI2 and 91% and 93% for MRI1. Statistically significant higher diagnostic confidence was found for PET/MRI2 and MRI2 datasets compared to PET/MRI1 and MRI1, respectively (p < 0.001). CONCLUSION: The application of the liver-specific contrast phase in 18F-FDG PET/MRI further increases the diagnostic accuracy and diagnostic confidence for correct assessment of benign and malignant liver lesions.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste/farmacocinética , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos/farmacocinética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adulto , Idoso , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Carcinoma Hepatocelular/metabolismo , Carcinoma Hepatocelular/secundário , Colangiocarcinoma/diagnóstico por imagem , Colangiocarcinoma/metabolismo , Colangiocarcinoma/patologia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/metabolismo , Neoplasias Colorretais/patologia , Feminino , Fluordesoxiglucose F18/farmacocinética , Humanos , Fígado/metabolismo , Fígado/patologia , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/secundário , Masculino , Meglumina/farmacocinética , Melanoma/diagnóstico por imagem , Melanoma/metabolismo , Melanoma/patologia , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/farmacocinética , Sensibilidade e Especificidade
8.
Nuklearmedizin ; 56(3): 73-81, 2017 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-28401244

RESUMO

AIM: Evaluate the diagnostic accuracy of 68Ga-labeled HBED-CC-PSMA-PET/MRI for detection of recurrent PCa in comparison to PET/CT. METHODS: 48 patients with suspected recurrent PCa underwent PET/CT after injection of the 68Ga-HBED-CC-PSMA ligand followed by integrated PET/MRI. Image analysis was performed by nuclear medicine physicians and radiologists with respect to the detection of lymph node metastases, bone metastases and local recurrence of the tumour. Image quality was evaluated visually based on a three-point ordinal scale. RESULTS: From 48 patients initially examined, 25 were finally eligible for qualitative and quantitative image evaluation. In 14 patients, neither PET/CT nor PET/MRI found tumour lesions, and 9 patients were excluded from image analysis due to a pronounced extinction artifact around the urinary bladder (halo). In comparison to 68Ga-HBED-CC-PSMA-PET/CT, 68Ga-HBED-CC-PSMA-PET/MRI identified 14 vs. 9 local recurrences in the prostate bed and 23 vs. 20 PET-positive lymph nodes, and 4 vs. 4 PET-positive bone lesions, respectively. While the improved detection of suspicious lymph nodes was primarily attributable to the PET component, the advantageous detection of tumour recurrences in the prostate bed was chiefly referable to the superior soft-tissue contrast of the MR component of integrated PET/MRI. Analysis of SUVmax revealed that 68Ga-HBED-CC-PSMA-PET/MRI provided significantly higher SUVmax compared to 68Ga-HBED-CC-PSMA-PET/CT (17.6, range 2.0-49.6, and 15.1, range 3.5-36.8, respectively, p = 0.0019). CONCLUSION: 68Ga-HBED-CC-PSMA-PET/MRI was found to be superior as compared to 68Ga-HBED-CC-PSMA-PET/CT in the detection of PSMA-expressing prostate bed recurrences.


Assuntos
Ácido Edético/análogos & derivados , Glutamato Carboxipeptidase II/farmacocinética , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Antígenos de Superfície , Meios de Contraste , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/metabolismo , Neoplasias da Próstata/metabolismo , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Phys Med Biol ; 61(9): 3504-20, 2016 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-27055014

RESUMO

Modern radiation therapy (RT) treatment planning is based on multimodality imaging. With the recent availability of whole-body PET/MR hybrid imaging new opportunities arise to improve target volume delineation in RT treatment planning. This, however, requires dedicated RT equipment for reproducible patient positioning on the PET/MR system, which has to be compatible with MR and PET imaging. A prototype flat RT table overlay, radiofrequency (RF) coil holders for head imaging, and RF body bridges for body imaging were developed and tested towards PET/MR system integration. Attenuation correction (AC) of all individual RT components was performed by generating 3D CT-based template models. A custom-built program for µ-map generation assembles all AC templates depending on the presence and position of each RT component. All RT devices were evaluated in phantom experiments with regards to MR and PET imaging compatibility, attenuation correction, PET quantification, and position accuracy. The entire RT setup was then evaluated in a first PET/MR patient study on five patients at different body regions. All tested devices are PET/MR compatible and do not produce visible artifacts or disturb image quality. The RT components showed a repositioning accuracy of better than 2 mm. Photon attenuation of -11.8% in the top part of the phantom was observable, which was reduced to -1.7% with AC using the µ-map generator. Active lesions of 3 subjects were evaluated in terms of SUVmean and an underestimation of -10.0% and -2.4% was calculated without and with AC of the RF body bridges, respectively. The new dedicated RT equipment for hybrid PET/MR imaging enables acquisitions in all body regions. It is compatible with PET/MR imaging and all hardware components can be corrected in hardware AC by using the suggested µ-map generator. These developments provide the technical and methodological basis for integration of PET/MR hybrid imaging into RT planning.


Assuntos
Carcinoma Broncogênico/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Sarcoma Sinovial/diagnóstico por imagem , Adulto , Artefatos , Carcinoma Broncogênico/radioterapia , Feminino , Cabeça/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Posicionamento do Paciente , Ondas de Rádio , Sarcoma Sinovial/radioterapia , Imagem Corporal Total/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA