Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 276
Filtrar
1.
N Engl J Med ; 382(9): 799-809, 2020 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-31995682

RESUMO

BACKGROUND: There are scant data on long-term clinical outcomes and bioprosthetic-valve function after transcatheter aortic-valve replacement (TAVR) as compared with surgical aortic-valve replacement in patients with severe aortic stenosis and intermediate surgical risk. METHODS: We enrolled 2032 intermediate-risk patients with severe, symptomatic aortic stenosis at 57 centers. Patients were stratified according to intended transfemoral or transthoracic access (76.3% and 23.7%, respectively) and were randomly assigned to undergo either TAVR or surgical replacement. Clinical, echocardiographic, and health-status outcomes were followed for 5 years. The primary end point was death from any cause or disabling stroke. RESULTS: At 5 years, there was no significant difference in the incidence of death from any cause or disabling stroke between the TAVR group and the surgery group (47.9% and 43.4%, respectively; hazard ratio, 1.09; 95% confidence interval [CI], 0.95 to 1.25; P = 0.21). Results were similar for the transfemoral-access cohort (44.5% and 42.0%, respectively; hazard ratio, 1.02; 95% CI, 0.87 to 1.20), but the incidence of death or disabling stroke was higher after TAVR than after surgery in the transthoracic-access cohort (59.3% vs. 48.3%; hazard ratio, 1.32; 95% CI, 1.02 to 1.71). At 5 years, more patients in the TAVR group than in the surgery group had at least mild paravalvular aortic regurgitation (33.3% vs. 6.3%). Repeat hospitalizations were more frequent after TAVR than after surgery (33.3% vs. 25.2%), as were aortic-valve reinterventions (3.2% vs. 0.8%). Improvement in health status at 5 years was similar for TAVR and surgery. CONCLUSIONS: Among patients with aortic stenosis who were at intermediate surgical risk, there was no significant difference in the incidence of death or disabling stroke at 5 years after TAVR as compared with surgical aortic-valve replacement. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estudos de Coortes , Ecocardiografia , Feminino , Nível de Saúde , Humanos , Incidência , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Complicações Pós-Operatórias/mortalidade , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 34(1): 229-230, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35946395

RESUMO

A 70-year-old woman with longstanding persistent atrial fibrillation underwent Micra leadless pacemaker implantation and atrioventricular nodal ablation. No postprocedural complications were noted. She subsequently underwent surgical mitral valve replacement 4 years later. During the surgery, Micra tine perforation of the right ventricular free wall was seen. No device revision was performed due to her asymptomatic status and stable pacemaker position/function. Pericardial effusion is a known complication of Micra implantation. The incidence of tine perforation is unknown as many patients may be asymptomatic. The clinical consequences regarding adverse events, device functionality, and explantation/extraction risk profile remain to be determined.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Marca-Passo Artificial , Humanos , Feminino , Idoso , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Nó Atrioventricular
3.
Catheter Cardiovasc Interv ; 101(7): 1221-1228, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37036273

RESUMO

BACKGROUND: Obesity has been associated with an increased risk of vascular complication during percutaneous coronary intervention, but there are no data on the risk of vascular complication during percutaneous transfemoral transcatheter aortic valve insertion (TAVI). OBJECTIVES: We hypothesized there would be a similar increased risk associated with TAVI. METHODS: We reviewed the records of 1176 patients who received percutaneous transfemoral transcatheter aortic valve insertion from September 2015 to September 2020. All patients received 1) preoperative computed tomoraphy angiography assessment of the abdomen and pelvis to delineate iliofemoral artery anatomy, 2) ultrasound-guided percutaneous femoral arterial access, and 3) pre-closure of the delivery sheath femoral access site. Vascular complication was recorded based on definitions set forth by Valve Academic Research Consortium 3. RESULTS: The median age of patients was 81 years, and 60% were men. The median body mass index (BMI) was 29 kg/m2 (range, 11-67), and 91 (8%) patients had a value ≥40 kg/m2 (i.e., morbid obesity). Delivery sheath size was 14-French in 859 (73%) patients, 16-French in 311 (26%), and 18-French in 6 (1%). Vascular complication occurred in 53 (5%) patients, including 39 (7%) among the first half of procedures and 14 (2%) among the second half (p < 0.001). When stratified by obesity status (BMI < or ≥30 kg/m2 , p < 0.001), the complication rate was 4% in nonobese patients and 5% in obese patients. Multivariable analysis showed no overall association between risk of vascular complication and BMI categories (p = 0.583)BMI continuous values (p = 0.529), or sheath size (p = 0.217). CONCLUSIONS: Obesity is not associated with a vascular complication during percutaneous transfemoral transcatheter aortic valve insertion. The operation should not be denied in obese patients.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Obesidade/complicações , Obesidade/epidemiologia , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia
4.
Catheter Cardiovasc Interv ; 99(3): 861-866, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34388299

RESUMO

OBJECTIVES: The aim of this study was to determine the safety of eliminating the pre-discharge transthoracic echocardiogram (TTE) on 30-day outcomes in patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TTE is utilized before, during, and after TAVR. Post-procedural, pre-discharge TTE assists in assessment of prosthesis function and detection of clinically significant paravalvular leak (PVL) after TAVR. METHODS: Patients who underwent TAVR at Mayo Clinic from July 2018 to July 2019 were included in a prospective institutional registry. Patients undergoing TAVR prior to February 2019 received a pre-discharge TTE, while those undergoing TAVR after February 2019 did not. Both cohorts were evaluated with TTE at 30 days post-TAVR. RESULTS: A total of 330 consecutive patients were included. Of these, 160 patients (age 81.1 ± 7.6) had routine pre-discharge TTE, while 170 patients (age 78.9 ± 7.5) were dismissed without routine pre-discharge TTE. Mortality at 30 days was similar between the two groups (0% and 1.2%, respectively). One episode of PVL requiring intervention (0.6%) occurred in the pre-discharge TTE group and none in the group without pre-discharge TTE at 30-day follow-up. There was a similar incidence of total composite primary and secondary adverse events between the cohort receiving a pre-discharge TTE and those without (28.1% vs. 25.3%, P = 0.56) at 30 days. The most common event was need for permanent pacemaker or ICD implantation in both groups (13.1% vs. 11.8%, P = 0.71). CONCLUSIONS: Elimination of the pre-discharge TTE is safe and associated with comparable 30-day outcomes to routine pre-discharge TTE. These findings have implication for TAVR practice cost-efficiency and health care utilization.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Alta do Paciente , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Hepatology ; 72(5): 1735-1746, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32080875

RESUMO

BACKGROUND AND AIMS: Hepatologists often determine whether transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) is preferred for patients with cirrhosis and severe aortic stenosis. The goal of this cohort study is to compare outcomes following TAVR and SAVR in patients with cirrhosis to inform the preferred intervention. APPROACH AND RESULTS: Prospectively collected data on 105 consecutive patients with cirrhosis and aortic stenosis who underwent TAVR (n = 55) or SAVR (n = 50) between 2008 and 2016 were reviewed retrospectively. Two control groups were included: 2,680 patients without cirrhosis undergoing TAVR and SAVR and 17 patients with cirrhosis who received medical therapy alone. Among the 105 patients with cirrhosis, the median Society of Thoracic Surgeons score was 3.8% (1.5, 6.9), and the median Model for End-Stage Liver Disease (MELD) score was 11.6 (9.4, 14.0). The TAVR group had similar in-hospital (1.8% vs. 2.0%) and 30-day mortality (3.6% vs. 4.2%) as the SAVR group. During the median follow-up of 3.8 years (95% confidence interval, 3.0-6.9), there were 63 (60%) deaths. MELD score (adjusted hazard ratio, 1.13; 95% confidence interval, 1.05-1.21; P = 0.002) was an independent predictor of long-term survival. In the subgroup of patients with MELD score <12, the TAVR group had reduced survival compared with the SAVR group (median survival of 2.8 vs. 4.4 years; P = 0.047). However, in those with MELD score ≥12, survival after TAVR, SAVR, and medical therapy was similar (1.3 vs. 2.1 vs. 1.6 years, respectively; P = 0.53). CONCLUSION: In select patients with cirrhosis, both TAVR and SAVR have acceptable and comparable short-term outcomes. MELD score, but not Society of Thoracic Surgeons score, independently predicts long-term survival after TAVR and SAVR. For patients with MELD score <12, SAVR is a preferred procedure; however, neither procedure appears superior to medical therapy in patients with MELD score ≥12.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença Hepática Terminal/complicações , Gastroenterologistas/normas , Cirrose Hepática/complicações , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/tratamento farmacológico , Estenose da Valva Aórtica/mortalidade , Tomada de Decisão Clínica , Doença Hepática Terminal/diagnóstico , Doença Hepática Terminal/patologia , Feminino , Mortalidade Hospitalar , Humanos , Cirrose Hepática/diagnóstico , Cirrose Hepática/mortalidade , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Estudos Retrospectivos , Medição de Risco/normas , Fatores de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 97(5): 895-902, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33022117

RESUMO

OBJECTIVES: The aim of this study was to assess the 30 day incidence of paravalvular leak (PVL) and need for aortic valve reintervention of a fourth generation balloon expandable transcatheter valve with enhanced skirt (4G-BEV) (SAPIEN 3 Ultra) compared with a third generation balloon expandable transcatheter valve (3G-BEV) (SAPIEN 3). BACKGROUND: The incidence of PVL has steadily declined with iterative improvements in transcatheter aortic valve replacement (TAVR) technology and implantation strategies. METHODS: Patients who underwent TAVR at Mayo Clinic from 7/2018 to 7/2019 were included in a prospective institutional registry. 4G-BEV has been utilized since 2/2019, and, after this date, 3G-BEV and 4G-BEV were simultaneously used. 4G-BEV had three sizes (20, 23, and 26 mm) while 3G-BEV included four sizes (20, 23, 26, and 29 mm). Both cohorts were evaluated at 30 days post-TAVR with a transthoracic echocardiogram to assess for PVL. RESULTS: A total of 260 consecutive patients were included. Of these, 101 patients received a 4G-BEV and 159 patients received a 3G-BEV. There were more females (p = .0005) and a lower aortic valve calcium score (p = .02) in the 4G-BEV cohort at baseline. Age, STS risk score, NYHA Class, and aortic valve mean gradient did not differ between groups. 4G-BEV was associated with a lower incidence of mild PVL (10.8 vs. 36.5%; p < .0001) and moderate PVL (0 vs. 5.8%) compared to the 3G-BEV at 30 days. There was no association between PVL and valve size in either cohort. CONCLUSIONS: Utilization of 4G-BEV is associated with reduced PVL at 30 days post-TAVR compared with 3G-BEV.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Estudos Prospectivos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
J Cardiothorac Vasc Anesth ; 35(12): 3797-3805, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33722460

RESUMO

Constrictive pericarditis is caused by pericardial inflammation and fibrosis, leading to diastolic heart failure. The diagnosis requires a high index of suspicion because it often can mimic restrictive myocardial disease and cardiac tamponade and can be associated with severe tricuspid regurgitation and chronic liver disease. Patients who remain undiagnosed can experience a 90% mortality rate, and for those who undergo pericardiectomy, the survival rate varies significantly, depending on the underlying etiology and preoperative functional class of the patient. In this article, the authors review the pathophysiology, echocardiographic findings, management, and surgical outcomes of constrictive pericarditis to aid the cardiothoracic anesthesiologist in the perioperative management of this disorder.


Assuntos
Insuficiência Cardíaca Diastólica , Pericardite Constritiva , Insuficiência da Valva Tricúspide , Humanos , Pericardiectomia , Pericardite Constritiva/diagnóstico por imagem , Pericardite Constritiva/cirurgia , Taxa de Sobrevida
8.
J Card Surg ; 36(12): 4743-4745, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34608675

RESUMO

The results of a meta-analysis are more than just the reported odds ratio, 95% confidence interval (CI), and p value. Of equal importance is the fine print of the study which should include assessment of the risk of bias, certainty in evidence, and heterogeneity in the individual point estimates and CIs. These areas all have an influence on the quality of the data in the analysis. Reading and understanding the fine print is important.


Assuntos
Metanálise como Assunto , Humanos
9.
J Card Surg ; 36(2): 772-774, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33410208

RESUMO

A 72-year-old man presented with symptomatic, severe aortic valve stenosis and a chronic descending thoracic aorta dissection with descending thoracic aortic aneurysm. After careful consideration, a transcatheter aortic valve was inserted through a transfemoral approach. This case demonstrates feasibility, and consideration should be given to this approach in patients requiring intervention for aortic stenosis.


Assuntos
Dissecção Aórtica , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Masculino , Resultado do Tratamento
10.
J Med Syst ; 45(4): 53, 2021 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-33704592

RESUMO

The Transcatheter Aortic Valve Replacement (TAVR) procedure requires an initial consultation and a subsequent procedure by an interventionalist (IC) and surgeon. The IC-surgeon pair coordination is extremely challenging, especially at Mayo Clinic due to provider time commitments distributed across practice, research, and education activities. Current practice aims to establish the coordination manually, resulting in a scheduling process that is cumbersome and time consuming for the schedulers. We develop an algorithm for pairing ICs and surgeons that minimizes the lead time (days elapsed between the clinic consult and procedure). As compared to current practice, this algorithm is able to reduce average lead time by 59% and increase possible IC-surgeon pairs by 7%. The proposed algorithm is shown to be flexible enough to incorporate practice variations such as lead time upper bound and two procedure days for a single consult day. Algorithm alternatives are also presented for practices who may find the proposed algorithm infeasible for their practice.


Assuntos
Estenose da Valva Aórtica , Cirurgiões , Substituição da Valva Aórtica Transcateter , Algoritmos , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco , Resultado do Tratamento
11.
Circulation ; 140(15): 1251-1260, 2019 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-31589485

RESUMO

BACKGROUND: Mitral stenosis frequently coexists in patients with severe aortic stenosis. Mitral stenosis severity evaluation is challenging in the setting of combined aortic stenosis and mitral stenosis because of hemodynamic interactions between the 2 valve lesions. The impact of aortic valve replacement (AVR) for severe aortic stenosis on mitral stenosis is unknown. This study aimed to assess the effect of AVR on mitral stenosis hemodynamics and the clinical outcomes of patients with severe aortic stenosis with and without mitral stenosis. METHODS: We retrospectively investigated patients who underwent surgical AVR or transcatheter AVR for severe aortic stenosis from 2008 to 2015. Mean transmitral gradient by Doppler echocardiography ≥4 mm Hg was identified as mitral stenosis; patients were then stratified according to mitral valve area (MVA, by continuity equation) as >2.0 cm2 or ≤2.0 cm2. MVA before and after AVR in patients with mitral stenosis were evaluated. Clinical outcomes of patients with and without mitral stenosis were compared using 1:2 matching for age, sex, left ventricular ejection fraction, method of AVR (surgical AVR versus transcatheter AVR) and year of AVR. RESULTS: Of 190 patients with severe aortic stenosis and mitral stenosis (age 76±9 years, 42% men), 184 were matched with 362 with severe aortic stenosis without mitral stenosis. Among all mitral stenosis patients, the mean MVA increased after AVR by 0.26±0.59 cm2 (from 2.00±0.50 to 2.26±0.62 cm2, P<0.01). MVA increased in 105 (55%) and remained unchanged in 34 (18%). Indexed stroke volume ≤45 mL/m2 (odds ratio [OR] 2.40; 95% CI, 1.15-5.01; P=0.020) and transcatheter AVR (OR, 2.36; 95% CI, 1.17-4.77; P=0.017) were independently associated with increase in MVA. Of 107 with significant mitral stenosis (MVA ≤2.0 cm2), MVA increased to >2.0 cm2 after AVR in 52 (49%, pseudo mitral stenosis) and remained ≤2.0 cm2 in 55 (51%, true mitral stenosis). During follow-up of median 2.9 (0.7-4.9) years, true mitral stenosis was an independent predictor of all-cause mortality (adjusted hazard ratio, 1.88; 95% CI, 1.20-2.94; P<0.01). CONCLUSIONS: MVA improved after AVR in nearly half of patients with severe aortic stenosis and mitral stenosis. MVA remained ≤2.0 cm2 (true mitral stenosis) in nearly half of patients with severe aortic stenosis and significant mitral stenosis; this was associated with worse survival among patients undergoing AVR for severe aortic stenosis.


Assuntos
Hemodinâmica/fisiologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/mortalidade , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Doppler/mortalidade , Ecocardiografia Doppler/tendências , Feminino , Seguimentos , Humanos , Masculino , Estenose da Valva Mitral/cirurgia , Prognóstico , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/tendências
12.
Catheter Cardiovasc Interv ; 96(5): E552-E556, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32352630

RESUMO

Antegrade transseptal approach was utilized in the first human case of transcatheter aortic valve replacement (TAVR) and in the early phase of TAVR. Various challenges with the antegrade transseptal approach including procedural complexity, need for atrial septal crossing, and potential for injury to the mitral valve apparatus led it to being supplanted by other approaches. These challenges have now largely been mitigated as structural interventionalists routinely perform left atrial procedures. We report a case of antegrade transseptal TAVR using a large bore sheath placed in the mid left ventricle across the mitral orifice to protect the mitral valve apparatus and facilitate valve deployment. An 84-year-old man with heart failure symptoms was seen for severe aortic stenosis. The severity of peripheral arterial disease precluded femoral, axillary, carotid, or transcaval routes. After transseptal puncture and creation of an arteriovenous rail, a long 26-Fr sheath was advanced from the right femoral vein transseptally over the arteriovenous rail, past the mitral valve inflow to the mid left ventricular cavity. The sheath provided a stable platform with stable intraprocedure hemodynamics. Balloon valvuloplasty was performed in an antegrade manner, after which a 29-mm SAPIEN S3 prosthesis was advanced into the aortic valve position and deployed under rapid pacing. We observed no injury to the mitral leaflets or subvalvular apparatus after the procedure. The antegrade transseptal approach should be revisited as an option for patients at high surgical risk with no other suitable access site. The use of a large bore sheath facilitates this approach.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Evolução Fatal , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Próteses Valvulares Cardíacas , Humanos , Masculino , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
13.
J Surg Res ; 253: 288-293, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32402854

RESUMO

BACKGROUND: Coronary artery aneurysms (CAAs) represent a rare pathology occurring in 1.5%-5% of routine coronary angiograms. Limited data exist on the management of CAA at the time of cardiac surgery. MATERIALS AND METHODS: A single-institution retrospective review was performed on 53 patients who underwent cardiac surgery in the setting of atherosclerotic CAA between 1993 and 2015. Patients were stratified based on treatment strategy: exclusion and distal bypass (n = 26) versus revascularization alone (n = 27). Comparisons were made with respect to mortality, need for further/concomitant interventions, and long-term cardiac function including myocardial infarctions and congestive heart failure. RESULTS: A total of 53 patients underwent cardiac surgery in the setting of CAA disease. Management strategies included ligation and bypass in 26 patients and distal bypass only in 27 patients (with four of the patients in this group undergoing coronary stenting across the aneurysm). There were no significant differences in patient demographics between the two groups. No significant difference was found in either 30-d (P = 0.74) or long-term mortality when exclusion of the CAA was performed compared with revascularization alone (P = 0.20). More exclusion procedures were performed earlier in the experience (median surgical date 2000), whereas revascularization alone predominated later in the experience (median surgical date 2007; P ≤ 0.001). CONCLUSIONS: The practice of CAA exclusion, while still performed in selected cases, has largely been supplanted in patients undergoing revascularization. Exclusion does not appear to offer any advantage over isolated revascularization, supporting the current trends in managing this rare condition.


Assuntos
Aneurisma Coronário/cirurgia , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Coronário/complicações , Aneurisma Coronário/diagnóstico , Aneurisma Coronário/mortalidade , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Ligadura/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
14.
J Cardiovasc Pharmacol ; 75(1): 41-44, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31633585

RESUMO

BACKGROUND: Use of an anticoagulant after transcatheter aortic valve replacement (TAVR) has been increasing in practice after noted leaflet thrombosis on dual antiplatelet therapy. As the use of anticoagulation increases so does the number of poor warfarin candidates or warfarin intolerant patients. While direct oral anticoagulant (DOAC) use is increasing for other indications, there is a paucity of data for use after TAVR. The objective of this case series is to add to the available evidence for patients who may require a DOAC after TAVR. METHODS: A single-center, retrospective observational case series was conducted including adults 18 years of age and older who received a DOAC after TAVR between November 2008 and June 2018 at Mayo Clinic Hospital-Rochester. All patients were identified as part of the Society of Thoracic Surgeons database. RESULTS: Twenty-one patients were identified as having received a DOAC after TAVR. Median age was 83.5 years (interquartile range 77-87), with 71% males. Within this cohort, 20 patients (95.2%) had an alternative indication for anticoagulation of either atrial fibrillation or atrial flutter. Apixaban was prescribed in 66.7% of patients, followed by rivaroxaban (14.3%), dabigatran (9.5%), and edoxaban (4.8%). No thromboembolic events were reported. Three patients experienced a bleeding event, of which only 2 occurred in the 3 months immediately after TAVR. CONCLUSIONS: DOAC therapy after TAVR was generally safe and well tolerated. Taken in context of other retrospective studies, these data suggest that the presence of valvular heart disease, specifically TAVR in this case, should not preclude the use of DOACs.


Assuntos
Antitrombinas/administração & dosagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Fibrilação Atrial/tratamento farmacológico , Flutter Atrial/tratamento farmacológico , Inibidores do Fator Xa/administração & dosagem , Tromboembolia/prevenção & controle , Substituição da Valva Aórtica Transcateter , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Antitrombinas/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Flutter Atrial/complicações , Flutter Atrial/diagnóstico , Bases de Dados Factuais , Inibidores do Fator Xa/efeitos adversos , Feminino , Hemorragia/induzido quimicamente , Humanos , Masculino , Minnesota , Estudos Retrospectivos , Fatores de Risco , Tromboembolia/diagnóstico por imagem , Tromboembolia/etiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
BMC Cardiovasc Disord ; 20(1): 33, 2020 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-32000672

RESUMO

BACKGROUND: Aortic stenosis (AS) causes left ventricular (LV) pressure overload, leading to adverse LV remodeling and dysfunction. Identifying early subclinical markers of LV dysfunction in patients with significant AS is critical as this could provide support for earlier intervention, which may result in improved long-term outcomes. We therefore examined the impact of severe AS and its consequent increase in LV afterload on myocardial deformation and rotational mechanics by 2-dimensional (2D) and 3-dimensional (3D) speckle-tracking echocardiography. METHODS: We prospectively measured various strain parameters in 168 patients (42% female, mean age 72 ± 12 years) with severe AS and LV ejection fraction (EF) ≥50%, and compared them to normal values found in literature. 2D and 3D images were analyzed for global longitudinal strain (GLS), global circumferential strain (GCS), global radial strain (GRS), basal rotation, apical rotation, and peak systolic twist. We further assessed the degree of concordance between 2D and 3D strain, and examined their association with measures of LV preload and afterload. RESULTS: Patients with severe AS exhibited significantly lower GLS and GRS but higher GCS, apical rotation, and twist by 2D and 3D echocardiography compared with published normal values (P = 0.003 for 3D twist, P < 0.001 for all others). Agreement between 2D- and 3D-GLS by concordance correlation coefficient was 0.49 (95% confidence interval: 0.39-0.57). GLS was correlated with valvulo-arterial impedance, a measure of LV afterload (r = 0.34, p < 0.001 and r = 0.23, p = 0.003, respectively). CONCLUSION: Patients with severe AS demonstrated lower-than-normal GLS and GRS but appear to compensate with higher-than-normal GCS, apical rotation, and twist in order to maintain a preserved LVEF. GLS showed a modest correlation with valvulo-arterial impedance.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional , Contração Miocárdica , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/fisiopatologia , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Rotação , Índice de Gravidade de Doença , Disfunção Ventricular Esquerda/fisiopatologia
16.
Eur Heart J ; 45(1): 73, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37978870
17.
N Engl J Med ; 374(17): 1609-20, 2016 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-27040324

RESUMO

BACKGROUND: Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. METHODS: We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. RESULTS: The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan-Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoral-access cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. CONCLUSIONS: In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Complicações Pós-Operatórias/mortalidade , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Ultrassonografia
18.
Catheter Cardiovasc Interv ; 94(5): 738-744, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30688003

RESUMO

BACKGROUND: The effect of utilizing transapical (TA) access for transcatheter aortic valve replacement (TAVR) on cardiac function has not been well studied. AIMS: The aim of this retrospective study is to determine the direct effects of TA access for TAVR on myocardial function parameters and their correlation with 4-year survival. METHODS: Three hundred and thirty propensity matched patients, who underwent TAVR using Sapien valve (Edwards Lifesciences Corp, Irvine, CA) between February 15, 2012 and June 17, 2016 (115 TA and 115 transfemoral [TF] routes) were studied. The pre- and 1 month post-TAVR echocardiographic features of both groups were compared. The 4-year survival in both groups was analyzed. RESULTS: Baseline clinical characteristics, diastolic function parameters, left ventricular (LV) chamber size, and ejection fraction were similar between matched TA and TF groups. At 1 month following TAVR, there was a significant increase in stroke volume index (SVI) in both TA (mean increase 7 cm3 /m2 ; P = 0.03) and TF groups (mean increase 7 cm3 /m2 ; P < 0.001). Left ventricular ejection fraction (LVEF) significantly increased post TF TAVR (mean increase 2%; P = 0.008), but no significant increase was observed post TA TAVR (mean increase 1%; P = 0.27). Both groups had significant improvement in aortic valve (AV) hemodynamics post-TAVR (P < 0.001). Overall, there were no significant differences in the mean change of SVI, LVEF, or left ventricular end diastolic dimensions (LVEDDs) post TA versus TF TAVR. There was no significant difference in 4-year survival in the TF compared to TA group (49% vs 50%, P = 0.43). CONCLUSION: Both TA and TF TAVR were equally associated with favorable changes in LV SVI and AV hemodynamics in 30 days. TA TAVR patients had similar 4 year survival to propensity matched TF TAVR; therefore, TA TAVR remains an acceptable alternative access route in patients not amenable to TF TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Cateterismo Periférico , Artéria Femoral , Substituição da Valva Aórtica Transcateter , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Feminino , Hemodinâmica , Humanos , Masculino , Punções , Estudos Retrospectivos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
19.
J Vasc Surg ; 67(3): 713-721, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29122422

RESUMO

OBJECTIVE: The objective of this study was to compare outcomes after repair of type III and type IV thoracoabdominal aortic aneurysms (TAAAs) by three different open surgical techniques at a tertiary care institution. METHODS: Consecutive patients who underwent elective repair of type III and type IV TAAAs at our institution between 1999 and 2011 were retrospectively reviewed. Patients were divided into three groups according to surgical technique: clamp and sew (CS), left-sided heart bypass (LHB), and visceral branching (VB) followed by aortic reconstruction. Primary end points were early mortality and complications; secondary end points were need for blood transfusion, duration of operation, and long-term survival. RESULTS: Between 1999 and 2011, there were 121 consecutive patients (83 men, 38 women) with 52 type III and 69 type IV TAAAs who underwent elective repair (CS, 65 patients; LHB, 31 patients; VB, 25 patients). Perioperative spinal drainage was used in 84%. Procedure duration was longest in the VB group (mean, 9.1 hours vs 7.7 hours and 5.7 hours for CS and LHB; P < .001), but transfusion requirement was largest in the LHB group (mean, 3.5 L vs 1.7 L and 2.1 L for CS and VB; P = .015). Mean duration of mesenteric ischemia was significantly shorter in the VB group vs CS and LHB (18 minutes vs 35 minutes for CS and 30 minutes for LHB; P < .0001). Mean intensive care unit and hospital stays were the same (9, 10, and 8 days [P = .82]; 18, 20, and 18 days [P = .76]). Overall 30-day mortality was 6.6%, not different between groups (6%, 10%, and 4%; P = .68). Mean follow-up was 45 ± 42 months, and actuarial overall survival at 3 and 5 years was 70% and 64%, with no difference between groups (P = .36). CONCLUSIONS: For repair of type III and type IV TAAAs, the sequential VB technique has the longest duration, but it has the advantage of the shortest mesenteric and visceral ischemia times without improvement in early outcomes. Irrespective of the techniques used, complications, early mortality, risk of spinal cord injury, and survival were the same.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 91(5): 975-983, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28963771

RESUMO

OBJECTIVE: The aim of this study was to perform a systematic review and meta-analyses of observational studies of transcatheter aortic valve replacement (TAVR) for bicuspid aortic valve stenosis (BcAV). BACKGROUND: TAVR for BcAV stenosis has been associated with an increased incidence of paravalvular leaks, valve malposition, pacemaker placement and all-cause mortality. The conclusions drawn have been limited by small sample sizes. The use of TAVR for BcAV stenosis remains controversial. METHODS: We searched multiple databases from the inception of the databases through September 30, 2016 for studies of TAVR for BcAV stenosis. We included all observational studies with more than one patient and at least 1 month of outcomes. RESULTS: We analyzed 13 observational studies with 758 patients. Meta analyses showed device success rate of 95% [95% confidence interval (CI) 90.2% to 98.5%] and an early safety event in 16.9% [95% CI 12.2% to 22%]. At 30 days, moderate to severe paravalvular leak was seen in 12.2% [95% CI 3.1% to 24.8%] and new pacemaker implantation in 17.9% [95% CI 14.2% to 22%]. All-cause mortality was 3.7% [95% CI 2.1% to 5.6%], which should be viewed in the context of an STS PROM of 5.0%. CONCLUSIONS: This analysis suggests that TAVR for BcAV is not associated with excess mortality. The incidence of paravalvular leaks and pacemaker implant is increased compared to tricuspid aortic valve cohorts undergoing TAVR, and operators should weigh these potential complications against the clinical benefit provided by TAVR for BcAV patients at high risk for surgical valve replacement.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Tomada de Decisão Clínica , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Masculino , Estudos Observacionais como Assunto , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA