Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Molecules ; 25(6)2020 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-32183441

RESUMO

This work proposes a simple and easy-to-use flow-through system for the implementation of dynamic extractions, aiming at the evaluation of bioaccessible zinc and the characterization of leaching kinetics in dry dog food samples. The kinetic profile of Zn extraction was determined by flame atomic absorption spectroscopy and the results were fitted in an exponential function (R2 > 0.960) compatible with a two first-order reactions model. Values of fast leachable Zn ranged from 83 ± 1 to 313 ± 5 mg of Zn per kg of sample, with associated rate constants ranging from 0.162 ± 0.004 to 0.290 ± 0.014 min-1. Similar results were observed compared to the static batch extraction. The percentage of bioaccessible Zn ranged from 49.0 to 70.0%, with an average value of 58.2% in relation to total Zn content. Principal component analysis regarding the variables fast leachable Zn, associated rate constant, total Zn, and market segment, has shown that 84.6% of variance is explained by two components, where the second component (24.0%) presented loadings only for the fast leachable Zn and associated rate constant. The proposed method is suitable for the fast evaluation (<1 h) of leaching kinetics and bioaccessibility in dry dog food.


Assuntos
Zinco/química , Zinco/metabolismo , Ração Animal , Animais , Disponibilidade Biológica , Cães , Cinética , Compostos Orgânicos/química , Compostos Orgânicos/metabolismo , Análise de Componente Principal/métodos , Espectrofotometria Atômica/métodos
2.
Anal Chem ; 91(20): 12988-12996, 2019 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-31533417

RESUMO

Pharmaceuticals, certain food ingredients, and mammalian endogenous metabolic products in wastewater are mostly of human origin. They are anthropogenic markers. Proper knowledge of their levels in wastewater helps to track sources of pollutants in natural waters and allows for calculation of removal efficiencies in wastewater treatment plants. Here, we describe the development and application of an indirect competitive, multiplexing suspension array fluorescence immunoassay (SAFIA) for the detection of carbamazepine (CBZ), diclofenac (DCF), caffeine (CAF), and isolithocholic acid (ILA) in wastewater, covering those classes of anthropogenic markers. The assay consists of haptens covalently conjugated to fluorescence-encoded polystyrene core/silica shell microparticles to create a site for competitive binding of the antibodies (Abs). Bound Abs are then stained with fluorophore-labeled Abs. Encoding and signaling fluorescence of the particles are determined by an automated flow cytometer. For compatibility of the immunoassay with the 96-well microtiter plate format, a stop reagent, containing formaldehyde, is used. This enables a wash-free procedure while decreasing time-to-result. Detection limits of 140 ± 40 ng/L for CBZ, 180 ± 110 ng/L for CAF, 4 ± 3 ng/L for DCF, and 310 ± 70 ng/L for ILA are achieved, which meet the sensitivity criteria of wastewater analysis. We demonstrate the applicability of SAFIA to real wastewater samples from three different wastewater treatment plants, finding the results in good agreement with LC-MS/MS. Moreover, the accuracy in general exceeded that from classical ELISAs. We therefore propose SAFIA as a quick and reliable approach for wastewater analysis meeting the requirements for process analytical technology.


Assuntos
Biomarcadores/análise , Monitoramento Ambiental/métodos , Imunoensaio/métodos , Águas Residuárias/análise , Poluentes Químicos da Água/análise , Cafeína/análise , Carbamazepina/análise , Cromatografia Líquida , Diclofenaco/análise , Fluorescência , Humanos , Limite de Detecção , Suspensões , Espectrometria de Massas em Tandem , Águas Residuárias/química , Poluentes Químicos da Água/química
3.
Talanta ; 271: 125665, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38271840

RESUMO

The presence of endocrine-disrupting compounds (EDCs) in water poses a significant threat to human and animal health, as recognized by regulatory agencies throughout the world. The Yeast Estrogen Screen (YES) assay is an excellent method to evaluate the presence of these compounds in water due to its simplicity and capacity to assess the bioaccessible forms/fractions of these compounds. In the presence of a compound with estrogenic activity, Saccharomyces cerevisiae cells, containing a lacZ reporter gene encoding the enzyme ß-galactosidase, are induced, the enzyme is synthesised, and released to the extracellular medium. In this work, a YES-based approach encompassing the use of a lacZ reporter gene modified strain of S. cerevisiae, microcarriers as solid support, and a fluorescent substrate, fluorescein di-ß-d-galactopyranoside, is proposed, allowing for the assessment of EDCs' presence after only 2 h of incubation. The proposed method provided an EC50 of 0.17 ± 0.03 nM and an LLOQ of 0.03 nM, expressed as 17ß-estradiol. The assessment of different EDCs provided EC50 values between 0.16 and 1.2 × 103 nM. After application to wastewaters, similar results were obtained for EDCs screening, much faster, compared to the conventional 45 h spectrophotometric procedure using a commercial kit, showing potential for onsite high-throughput screening of environmental contamination.


Assuntos
Disruptores Endócrinos , Poluentes Químicos da Água , Humanos , Saccharomyces cerevisiae/genética , Estrogênios/análise , Estradiol/análise , Genes Reporter , Água , Disruptores Endócrinos/análise , Poluentes Químicos da Água/análise , Bioensaio
4.
Antioxidants (Basel) ; 12(2)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36830065

RESUMO

The analysis and interpretation of data retrieved from Oxygen Radical Absorbance Capacity (ORAC) assays represent a challenging task. ORAC indexes originate from different mathematical approaches often lacking correct elucidation of kinetic features concerning radical scavenging reactions by antioxidant compounds. In this work, the expression of ORAC values as area under fluorescein (FL) decay curves (AUC) and lag time are critically compared. This multi-parametric analysis showed the extension of radical scavenging reactions beyond the lag time period for caffeic acid, gallic acid, reduced glutathione and quercetin, extending their antioxidant protection of FL. Ethanol delayed the reaction of both FL and antioxidant compounds with free radical species generated from 2,2'-azobis(2-amidinopropane) dihydrochloride thermolysis. Trolox equivalent values, commonly used to express ORAC values, were more affected by the differences in radical scavenging kinetics between the reference and the tested antioxidant compounds when calculated from AUC than from lag time. These findings stressed the importance of choosing calibrator compounds presenting ORAC kinetics similar to samples to prevent biased estimation of the antioxidant capacity. Additionally, the framework proposed here provides a sustainable analytical method for the evaluation of antioxidant capacity, with an AGREE score of 0.73.

5.
Talanta ; 150: 599-606, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-26838448

RESUMO

An automated oxygen radical absorbance capacity (ORAC) method based on programmable flow injection analysis was developed for the assessment of antioxidant reactivity. The method relies on real time spectrophotometric monitoring (540 nm) of pyrogallol red (PGR) bleaching mediated by peroxyl radicals in the presence of antioxidant compounds within the first minute of reaction, providing information about their initial reactivity against this type of radicals. The ORAC-PGR assay under programmable flow format affords a strict control of reaction conditions namely reagent mixing, temperature and reaction timing, which are critical parameters for in situ generation of peroxyl radical from 2,2'-azobis(2-amidinopropane) dihydrochloride (AAPH). The influence of reagent concentrations and programmable flow conditions on reaction development was studied, with application of 37.5 µM of PGR and 125 mM of AAPH in the flow cell, guaranteeing first order kinetics towards peroxyl radicals and pseudo-zero order towards PGR. Peroxyl-scavenging reactivity of antioxidants, bioactive compounds and phenolic-rich beverages was estimated employing the proposed methodology. Recovery assays using synthetic saliva provided values of 90 ± 5% for reduced glutathione. Detection limit calculated using the standard antioxidant compound Trolox was 8 µM. RSD values were <3.4 and <4.9%, for intra and inter-assay precision, respectively. Compared to previous batch automated ORAC assays, the developed system also accounted for high sampling frequency (29 h(-1)), low operating costs and low generation of waste.


Assuntos
Antioxidantes/análise , Corantes/química , Peróxidos/química , Pirogalol/análogos & derivados , Espécies Reativas de Oxigênio/química , Peróxidos/metabolismo , Pirogalol/química , Espécies Reativas de Oxigênio/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA