1.
Sensors (Basel) ; 24(4)2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38400436

RESUMO

This paper introduces an innovative sensor utilizing bubbles coated with thermochromic paint, aiming to facilitate temperature measurements in challenging-to-reach locations without the requirement of an external power source. The research conducted is innovative in terms of both methodology and application. The characterization of the thermochromic properties of paints was, in fact, performed using spectroradiometric measurements by selecting a temperature range useful for applications in various fields including preventive conservation. The study encompasses two main objectives: (1) analyzing the color characteristics of thermochromic paint and plastic resin that forms the bubbles, and (2) assessing a temperature sensor comprising a thermochromic paint-coated bubble subjected to temperature variations. The thermochromic paint exhibits reversible color modifications in response to temperature changes, making it an ideal candidate for applications of this nature. The color characterization phase involves measurements using a spectroradiometer to compare the spectral reflectance factor (SRF%) of the colored plastic resin spread on canvas with that of the inflated bubbles. The sensor characterization entails evaluating color changes of the thermochromic paint on the bubble surface with varying temperatures. Experimental results indicate that the combination of a red (R) bubble and blue (B) thermochromic paint produces quantifiable color variations suitable for the proposed applications, whereas the alternative combination under examination, namely a blue bubble and red thermochromic paint, yields less accurate results. Considering that for both thermochromic paints the color change temperature is 35 °C, it is possible to see how, for B bubble with R thermochromic paint, the chromatic coordinates change value: C* = 3.14 ± 0.14 and h = 289.54 ± 11.58 at room temperature, while C* = 2.96 ± 0.12 and h = 304.20 ± 12.17 at 35 °C. The same is true for R bubble with B thermochromic paint where C* = 25.31 ± 1.01 and h* = 285.05 ± 11.40 at room temperature, while C* = 20.87 ± 0.85 and h = 288.37 ± 11.53 at 35 °C. The study demonstrates the potential of the approach and suggests further investigations into reproducibility and expanded color combinations. The results provide a promising basis for future improvements in temperature monitoring with thermochromic bubble sensors.

2.
Radiat Environ Biophys ; 56(4): 471-480, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28929295

RESUMO

This work deals with the dosimetric features of a particular phenolic compound (IRGANOX 1076®) for dosimetry of clinical photon beams by using electron spin resonance (ESR) spectroscopy. After the optimization of the ESR readout parameters (namely modulation amplitude and microwave power) to maximise the signal without excessive spectrum distortions, basic dosimetric properties of laboratory-made phenolic dosimeters in pellet form, such as reproducibility, dose-response, sensitivity, linearity and dose rate dependence were investigated. The dosimeters were tested by measuring the depth dose profile of a 6 MV photon beam. A satisfactory intra-batch reproducibility of the ESR signal of the manufactured dosimeters was obtained. The ESR signal proved to increase linearly with increasing dose in the investigated dose range 1-13 Gy. The presence of an intrinsic background signal limits the minimum detectable dose to a value of approximately 0.6 Gy. Reliable and accurate assessment of the dose was achieved, independently of the dose rate. Such characteristics, together with the fact that IRGANOX 1076® is almost tissue-equivalent, and the stability of the ESR signal, make these dosimeters promising materials for ESR dosimetric applications in radiotherapy.


Assuntos
Fenóis/química , Fótons/uso terapêutico , Radiometria/métodos , Espectroscopia de Ressonância de Spin Eletrônica , Micro-Ondas , Modelos Moleculares , Conformação Molecular , Dosagem Radioterapêutica
3.
Radiol Med ; 119(12): 942-950, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25024060

RESUMO

PURPOSE: The present study was aimed at verifying the automatic registration of the Focal (Elekta) platform with a dedicated phantom. MATERIALS AND METHODS: A phantom that simulates the pelvis region in a stylised way and finalised to the registration of computed tomography-magnetic resonance images was designed and realised. After acquiring the two sets of images, the registration was performed both in automatic and manual mode to verify whether they were comparable. To test the repeatability of the automatic registration, some known rigid transformations were imposed to the original images. If the registration method works correctly, parameters which bring the images into alignment must always be the same. RESULTS: Automatic registration performed by the software did not prove satisfactory, whereas if a specific tool [volume of interest (VOI) tool] allowing the calculation to be limited to the landmark region was used, the registration parameters were comparable with those of the manual registration. Regarding the repeatability of the automatic registration, the software brought the images in the correct alignment performing translations and rotations along the longitudinal axis up to 40°, while it was not satisfactory for rotations along the transverse axes. CONCLUSION: The experimental results showed that in clinical application automatic registration is reliable if the VOI tool that includes visible landmarks in both studies is used. However, because the algorithm did not prove sensitive to rotations along the transverse axes, the position of the patient during the examinations plays a crucial role.


Assuntos
Imageamento por Ressonância Magnética , Imagens de Fantasmas/normas , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Imagem Multimodal , Estudos de Validação como Assunto
4.
Phys Med ; 112: 102627, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37348452

RESUMO

PURPOSE: This study aims to compare two methods for the organ dose evaluation in computed tomography (CT) in the head- and thorax regions: an experimental method, using radiochromic films, and a computational one, using a commercial software. METHODS: Gafchromic® XR-QA2 and EBT-3 were characterized in terms of energetic, angular, and irradiation configurations dependence. Two free-in-air irradiation calibration configurations were employed using a CT scanner: with the sensitive surface of the film orthogonal (OC) and parallel (PC) to the beam axis. Different dose-response curves were obtained by varying the irradiation configurations and the beam quality (BQ). Subsequently, films were irradiated within an anthropomorphic phantom using CT-thorax and -head protocols, and the organ dose values obtained were compared with those provided by the commercial software. RESULTS: At different configurations, an unchanged dose response was achieved with EBT-3, while a dose response of 15% was obtained with XR-QA2. By varying BQ, XR-QA2 showed a different response below 10%, while EBT-3 showed a variation below 5% for dose values >20 mGy. For films irradiation angle equal to 90°, the normalized to 0° relative response was 41% for the XR-QA2 model and 83% for the EBT-3 one. Organ dose values obtained with EBT-3 for both configurations and with XR-QA2 for OC were in agreement with the DW values, showing percentage discrepancies of less than 25%. CONCLUSIONS: The obtained results showed the potential of EBT-3 in CT patient dosimetry since the lower angular dependence, compared to XR-QA2, compensates for low sensitivity in the diagnostic dose range.


Assuntos
Dosimetria Fotográfica , Radiometria , Humanos , Doses de Radiação , Dosimetria Fotográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Calibragem
5.
Gels ; 8(8)2022 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-36005082

RESUMO

Multiple brain metastases single-isocenter stereotactic radiosurgery (SRS) treatment is increasingly employed in radiotherapy department. Before its use in clinical routine, it is recommended to perform end-to-end tests. In this work, we report the results of five HyperArcTM treatment plans obtained by both ionization chamber (IC) and polymer gel. The end-to-end tests were performed using a water equivalent Mobius Verification PhantomTM (MVP) and a 3D-printed anthropomorphic head phantom PseudoPatient® (PP) (RTsafe P.C., Athens, Greece); 2D and 3D dose distributions were evaluated on the PP phantom using polymer gel (RTsafe). Gels were read by 1.5T magnetic resonance imaging (MRI). Comparison between calculated and measured distributions was performed using gamma index passing rate evaluation by different criteria (5% 2 mm, 3% 2 mm, 5% 1 mm). Mean point dose differences of 1.01% [min −0.77%−max 2.89%] and 0.23% [min 0.01%−max 2.81%] were found in MVP and PP phantoms, respectively. For each target volume, the obtained results in terms of gamma index passing rate show an agreement >95% with 5% 2 mm and 3% 2 mm criteria for both 2D and 3D distributions. The obtained results confirmed that the use of a single isocenter for multiple lesions reduces the treatment time without compromising accuracy, even in the case of target volumes that are quite distant from the isocenter.

6.
Aust Endod J ; 47(1): 20-26, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33169440

RESUMO

Cutting efficiency of Reciproc R25 (REC) and Reciproc blue R25 (REB) at different inclinations was evaluated. Sixty new files were tested at 90°, 70° and 45° of inclination in relation to the sample (n = 10), using a customised machine. All files were activated in reciprocation against standardised gypsum blocks for 120 s. Cutting efficiency was determined by measuring the block weight loss with an analytical balance and measuring the length of the block surface cut using a digital calliper. Data were statistically analysed (two-way ANOVA, Bonferroni t-test) with the significance level set at P < 0.05. There was no difference for REC among the tested angles. REB had no statistical difference between 90° and 70°; however, its cutting efficiency significantly increased at 45°. There was a significant difference between REC and REB at 45° only. Under these conditions, increased file inclination to 45° and blue heat treatment improved cutting efficiency of reciprocating files.


Assuntos
Níquel , Titânio , Instrumentos Odontológicos , Desenho de Equipamento , Temperatura Alta , Incidência , Teste de Materiais , Preparo de Canal Radicular
7.
Radiol Phys Technol ; 11(2): 184-191, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29626289

RESUMO

The study is aimed at a verification of dose changes for a computed tomography automatic tube-current modulation (ATCM) technique. For this purpose, anthropomorphic phantom and Gafchromic® XR-QA2 films were used. Radiochromic films were cut according to the shape of two thorax regions. The ATCM algorithm is based on noise index (NI) and three exam protocols with different NI were chosen, of which one was a reference. Results were compared with dose values displayed by the console and with Poisson statistics. The information obtained with radiochromic films has been normalized with respect to the NI reference value to compare dose percentage variations. Results showed that, on average, the information reported by the CT console and calculated values coincide with measurements. The study allowed verification of the dose information reported by the CT console for an ATCM technique. Although this evaluation represents an estimate, the method can be a starting point for further studies.


Assuntos
Tomografia Computadorizada por Raios X/instrumentação , Algoritmos , Automação , Humanos , Imagens de Fantasmas , Controle de Qualidade , Radiometria