Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 49(4): 1263-1274, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34651219

RESUMO

PURPOSE: FDG-PET is an established supportive biomarker in dementia with Lewy bodies (DLB), but its diagnostic accuracy is unknown at the mild cognitive impairment (MCI-LB) stage when the typical metabolic pattern may be difficultly recognized at the individual level. Semiquantitative analysis of scans could enhance accuracy especially in less skilled readers, but its added role with respect to visual assessment in MCI-LB is still unknown. METHODS: We assessed the diagnostic accuracy of visual assessment of FDG-PET by six expert readers, blind to diagnosis, in discriminating two matched groups of patients (40 with prodromal AD (MCI-AD) and 39 with MCI-LB), both confirmed by in vivo biomarkers. Readers were provided in a stepwise fashion with (i) maps obtained by the univariate single-subject voxel-based analysis (VBA) with respect to a control group of 40 age- and sex-matched healthy subjects, and (ii) individual odds ratio (OR) plots obtained by the volumetric regions of interest (VROI) semiquantitative analysis of the two main hypometabolic clusters deriving from the comparison of MCI-AD and MCI-LB groups in the two directions, respectively. RESULTS: Mean diagnostic accuracy of visual assessment was 76.8 ± 5.0% and did not significantly benefit from adding the univariate VBA map reading (77.4 ± 8.3%) whereas VROI-derived OR plot reading significantly increased both accuracy (89.7 ± 2.3%) and inter-rater reliability (ICC 0.97 [0.96-0.98]), regardless of the readers' expertise. CONCLUSION: Conventional visual reading of FDG-PET is moderately accurate in distinguishing between MCI-LB and MCI-AD, and is not significantly improved by univariate single-subject VBA but by a VROI analysis built on macro-regions, allowing for high accuracy independent of reader skills.


Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Doença por Corpos de Lewy , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/metabolismo , Biomarcadores/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Disfunção Cognitiva/metabolismo , Fluordesoxiglucose F18/metabolismo , Humanos , Doença por Corpos de Lewy/diagnóstico por imagem , Doença por Corpos de Lewy/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Reprodutibilidade dos Testes
2.
Alzheimer Dis Assoc Disord ; 36(4): 347-349, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34132671

RESUMO

Positron emission tomography (PET) with 18 F-Fluorodeoxyglucose ( 18 F-FDG) plays an outstanding role in the diagnostic work-up of dementia. Amyloid PET imaging is a complementary imaging technique for the early detection of Alzheimer disease (AD). ß-amyloid precursor protein ( APP ), Presenilin-1 ( PSEN1 ) and Presenilin-2 ( PSEN2 ) are the 3 main causative genes responsible for autosomal dominant early-onset Alzheimer disease (EOAD). This is the first report of 18 F-Florbetapir amyloid imaging findings in a 35-year-old male patient with EOAD carrying the G378E mutation in PSEN1 gene. Brain computed tomography (CT) and magnetic resonance imaging scans showed remarkable cerebral atrophy with dilatation of the cerebrospinal fluid spaces; furthermore, a 18 F-Florbetapir PET/CT scan demonstrated also widespread remarkable accumulation of the amyloid tracer in the cerebral cortex, with reduction of the normal contrast between white and gray matter and flattening of the external cortical margins. Furthermore, PET/CT showed intense 18 F-florbetapir uptake in the striatum and in the thalamus bilaterally. Our case supports the usefulness of amyloid PET imaging in the diagnostic work-up of EOAD.


Assuntos
Doença de Alzheimer , Masculino , Humanos , Adulto , Presenilina-1/genética , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/genética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Presenilina-2/genética , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18 , Mutação , Proteínas Amiloidogênicas/genética , Encéfalo/diagnóstico por imagem , Peptídeos beta-Amiloides
3.
Q J Nucl Med Mol Imaging ; 64(4): 414-421, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31089074

RESUMO

BACKGROUND: Three different amyloid tracers labeled with 18-flourine have been introduced into clinical use. The leaflets of tracers indicate different visual criteria for PET reporting. In clinical practice, it is not yet ascertained whether these criteria are equivalent in terms of diagnostic accuracy or if anyone is better than another. We aimed to evaluate the inter and intra-rater variability of visual assessment of 18F-Florbetapir PET/CT images among six independent readers with different clinical experience. METHODS: We analyzed 252 PET/CT scans, visually assessed by each reader three times, applying independently the three different reading criteria proposed. Each reader evaluated the regional uptake specifying for each cortical region a numeric value of grading of positivity in order to assign a final score. At the end of each reading a level of confidence was determined by assigning a score from 0 (negative) to 4 (positive). After first reading, those cases in which the evaluations by two experienced readers did not match (discordant cases) were independently reevaluated merging all the three different visual interpretation criteria. RESULTS: Good agreement was observed for visual interpretation among the six readers' confidence-level using independently the three visual reading criteria: ICC=0.83 (0.80-0.86) for 18F-florbetapir, ICC=0.84 (0.81-0.87) for 18F-florbetaben, and ICC=0.86 (0.83-0.88) for 18F-flutemetamol reading. A good inter-rater agreement was observed for final-score too: ICC=0.74 (0.70-0.78) for 18F-florbetapir; ICC=0.82 (0.79-0.85) for 18F-florbetaben; ICC=0.84 (0.81-0.87) for 18F-flutemetamol. Intra-rater agreement was good for final-score (from 0.76 to 0.90; P<0.001) and confidence-level (Spearman's rho from 0.89 to 1.00; P<0.001). Disagreement between the two experienced readers was observed in 22 of 252 cases (9%). The agreement converged over a second round of independent reading in 12 of 22 cases (54%), by merging all the criteria. CONCLUSIONS: All the criteria proposed are useful to determine the grading of positivity or negativity of amyloid deposition and their merging improves the diagnostic confidence and provides a better agreement.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Amiloide/metabolismo , Radioisótopos de Flúor/química , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/radioterapia , Compostos de Anilina/química , Benzotiazóis/química , Encéfalo , Etilenoglicóis/química , Radioisótopos de Flúor/farmacologia , Humanos , Interpretação de Imagem Assistida por Computador , Pessoa de Meia-Idade , Estilbenos/química
4.
Eur J Nucl Med Mol Imaging ; 46(8): 1642-1651, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31098748

RESUMO

PURPOSE: The aim of the study was to evaluate extrastriatal dopaminergic and serotonergic pathways in patients with Parkinson's disease (PD) and dementia with Lewy bodies (DLB) using 123I-FP-CIT SPECT imaging. METHODS: The study groups comprised 56 PD patients without dementia, 41 DLB patients and 54 controls. Each patient underwent a standardized neurological examination and 123I-FP-CIT SPECT. Binding in nigrostriatal and extrastriatal regions of interest was calculated in each patient from spatially normalized images. The occipital-adjusted specific to nondisplaceable binding ratio (SBR) in the different regions was compared among the PD patients, DLB patients and controls adjusting for the effects of age, sex, disease duration and serotonergic/dopaminergic treatment. Covariance analysis was used to determine the correlates of local and long-distance regions with extrastriatal 123I-FP-CIT deficits. RESULTS: Both PD and DLB patients showed lower 123I-FP-CIT SPECT SBR in several regions beyond the nigrostriatal system, especially the insula, cingulate and thalamus. DLB patients showed significantly lower 123I-FP-CIT SBR in the thalamus than controls and PD patients. Thalamic and cingulate 123I-FP-CIT SBR deficits were correlated, respectively, with limbic serotonergic and widespread cortical monoaminergic projections only in DLB patients but exhibited only local correlations in PD patients and controls. CONCLUSION: PD and DLB patients both showed insular dopamine deficits, whereas impairment of thalamic serotonergic pathways was specifically associated with DLB. Longitudinal studies are necessary to determine the clinical value of the assessment of extrastriatal 123I-FP-CIT SPECT.


Assuntos
Córtex Cerebral/diagnóstico por imagem , Neurônios Dopaminérgicos/metabolismo , Doença por Corpos de Lewy/diagnóstico por imagem , Doença de Parkinson/diagnóstico por imagem , Neurônios Serotoninérgicos/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Vias Neurais/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética , Substância Negra/diagnóstico por imagem , Tálamo/diagnóstico por imagem , Tropanos/farmacocinética
5.
Q J Nucl Med Mol Imaging ; 63(1): 83-92, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-29697220

RESUMO

In May 2017 some representatives of the Italian nuclear medicine and neurological communities spontaneously met to discuss the issues emerged during the first two years of routine application of amyloid PET with fluorinated radiopharmaceuticals in the real world. The limitations of a binary classification of scans, the possibility to obtain early images as a surrogate marker of regional cerebral bloos flow, the need for (semi-)quantification and, thus, the opportunity of ranking brain amyloidosis, the correlation with Aß42 levels in the cerebrospinal fluid, the occurrence and biological meaning of uncertain/boderline scans, the issue of incidental amyloidosis, the technical pittfalls leading to false negative/positive results, the position of the tool in the diagnostic flow-chart in the national reality, are the main topics that have been discussed. Also, a card to justify the examination to be filled by the dementia specialist and a card for the nuclear medicine physician to report the exam in detail have been approved and are available in the web, which should facilitate the creation of a national register, as previewed by the 2015 intersocietal recommendation on the use of amyloid PET in Italy. The content of this discussion could stimulate both public institutions and companies to support further research on these topics.


Assuntos
Amiloide/metabolismo , Idioma , Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Humanos , Processamento de Imagem Assistida por Computador , Itália , Traçadores Radioativos
6.
Alzheimers Dement ; 14(8): 1088-1098, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29679576

RESUMO

INTRODUCTION: We test the hypothesis that amyloid-positron emission tomography prescriptions, considered appropriate based on the Amyloid Imaging Taskforce (AIT) criteria, lead to greater clinical utility than AIT-inappropriate prescriptions. METHODS: We compared the clinical utility between patients who underwent amyloid-positron emission tomography appropriately or inappropriately and among the subgroups of patients defined by the AIT criteria. Finally, we performed logistic regressions to identify variables associated with clinical utility. RESULTS: We identified 171 AIT-appropriate and 67 AIT-inappropriate patients. AIT-appropriate and AIT-inappropriate cases did not differ in any outcomes of clinical utility (P > .05). Subgroup analysis denoted both expected and unexpected results. The logistic regressions outlined the primary role of clinical picture and clinical or neuropsychological profile in identifying patients benefitting from amyloid-positron emission tomography. DISCUSSION: Contrary to our hypothesis, also AIT-inappropriate prescriptions were associated with clinical utility. Clinical or neuropsychological variables, not taken into account by the AIT criteria, may help further refine criteria for appropriateness.


Assuntos
Comitês Consultivos/normas , Tomografia por Emissão de Pósitrons/normas , Idoso , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/metabolismo , Peptídeos beta-Amiloides , Encéfalo/metabolismo , Disfunção Cognitiva/diagnóstico por imagem , Disfunção Cognitiva/metabolismo , Feminino , Humanos , Testes Neuropsicológicos/estatística & dados numéricos , Tomografia por Emissão de Pósitrons/métodos
7.
Ann Neurol ; 80(3): 368-78, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27398636

RESUMO

OBJECTIVE: To compare the diagnostic value of striatal (123) I-2ß-carbomethoxy-3ß-(4-iodophenyl)-N-(3-fluoropropyl) nortropane ((123) I-FP-CIT) single photon emission computed tomography (SPECT) and (123) I-metaiodobenzylguanidine ((123) I-MIBG) myocardial scintigraphy in differentiating dementia with Lewy bodies (DLB) from other dementia types. METHODS: This prospective longitudinal study included 30 patients with a clinical diagnosis of DLB and 29 patients with non-DLB dementia (Alzheimer disease, n = 16; behavioral variant frontotemporal dementia, n = 13). All patients underwent (123) I-FP-CIT SPECT and (123) I-MIBG myocardial scintigraphy within a few weeks of clinical diagnosis. All diagnoses at each center were agreed upon by the local clinician and an independent expert, both unaware of imaging data, and re-evaluated after 12 months. Each image was visually classified as either normal or abnormal by 3 independent nuclear physicians blinded to patients' clinical data. RESULTS: Overall, sensitivity and specificity to DLB were respectively 93% and 100% for (123) I-MIBG myocardial scintigraphy, and 90% and 76% for (123) I-FP-CIT SPECT. Lower specificity of striatal compared to myocardial imaging was due to decreased (123) I-FP-CIT uptake in 7 non-DLB subjects (3 with concomitant parkinsonism) who had normal (123) I-MIBG myocardial uptake. Notably, in our non-DLB group, myocardial imaging gave no false-positive readings even in those subjects (n = 7) with concurrent medical illnesses (diabetes and/or heart disease) supposed to potentially interfere with (123) I-MIBG uptake. INTERPRETATION: (123) I-FP-CIT SPECT and (123) I-MIBG myocardial scintigraphy have similar sensitivity for detecting DLB, but the latter appears to be more specific for excluding non-DLB dementias, especially when parkinsonism is the only "core feature" exhibited by the patient. Our data also indicate that the potential confounding effects of diabetes and heart disease on (123) I-MIBG myocardial scintigraphy results might have been overestimated. Ann Neurol 2016;80:368-378.


Assuntos
3-Iodobenzilguanidina , Doença de Alzheimer/diagnóstico por imagem , Corpo Estriado/diagnóstico por imagem , Demência Frontotemporal/diagnóstico por imagem , Doença por Corpos de Lewy/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tropanos , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/normas , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/normas
8.
Neurodegener Dis ; 16(1-2): 111-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26618706

RESUMO

BACKGROUND: Beliefs of dementia experts about the pathogenic role of amyloid in Alzheimer's disease (AD) may affect the use of amyloid positron emission tomography (PET). OBJECTIVE: To assess the role attributed to amyloid in AD pathogenesis by Italian dementia experts, and whether this modulates the impact of amyloid PET results in their diagnostic workup. METHODS: 22 dementia experts rated their beliefs about the pathogenic role of amyloid. Then, we asked them to rate the probability of change in diagnosis based on the result of amyloid PET for 7 case vignettes, depicting patients who initially received a diagnosis based on a comprehensive workup and later received amyloid PET results consistent or inconsistent with the clinical picture. RESULTS: 55% of the experts assigned a dominant role to amyloid, and 32% attributed a similar role to amyloid and tau in AD pathogenesis. The probability of change in diagnosis ranged from 17% (SD = 21.6) for cases with consistent to 51% (SD = 34) for cases with inconsistent PET versus clinical data. Diagnostic change was not biased by the clinicians' beliefs about AD pathogenesis. CONCLUSIONS: This work supports an unbiased interpretation of amyloid PET across different beliefs about the pathogenic role of amyloid, and a belief-independent reluctance to change diagnosis in cases where change is expected and recommended.


Assuntos
Amiloide/metabolismo , Atitude do Pessoal de Saúde , Médicos/psicologia , Tomografia por Emissão de Pósitrons/psicologia , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/metabolismo , Diagnóstico Diferencial , Humanos , Itália , Projetos Piloto , Proteínas tau/metabolismo
9.
Eur J Nucl Med Mol Imaging ; 42(12): 1920-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26227534

RESUMO

PURPOSE: IQ-SPECT, an add-on to general purpose cameras based on multifocal collimation, can reduce myocardial perfusion imaging (MPI) acquisition times to one-fourth that of standard procedures (to 12 s/view). In a phantom study, a reduction of the acquisition time to one-eighth of the standard time (to 6 s/view) was demonstrated as feasible. It remains unclear whether such a reduction could be extended to clinical practice. METHODS: Fifty patients with suspected or diagnosed CAD underwent a 2-day stress-rest (99m)Tc-sestamibi MPI protocol. Two consecutive SPECT acquisitions (6 and 12 s/view) were performed. Electrocardiogram-gated images were reconstructed with and without attenuation correction (AC). Polar maps were generated and visually scored by two blinded observers for image quality and perfusion in 17 segments. Global and regional summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) were determined. Left ventricular volumes and ejection fraction were calculated based on automated contour detection. RESULTS: Image quality was scored higher with the 12 s/view acquisition, both with and without AC. Summed scores were statistically comparable between the 6 s/view and the 12 s/view acquisition, both globally and in individual coronary territories (e.g. in images with AC, SSS were 6.6 ± 8.3 and 6.2 ± 8.2 with 6 s and 12 s/view, respectively, p = 0.10; SRS were 3.9 ± 5.6 and 3.5 ± 5.3, respectively, p = 0.19; and SDS were 2.8 ± 5.7 and 2.6 ± 5.7, respectively, p = 0.59). Both acquisitions allowed MPI-based diagnosis of CAD in 25 of the 50 patients (with AC). Calculated end-diastolic volume (EDV) and end-systolic volume (ESV) were modestly higher with the 6 s/view acquisition than with the 12 s/view acquisition (EDV +4.8 ml at rest and +3.7 ml after stress, p = 0.003; ESV +4.1 ml at rest and +2.6 ml after stress, p = 0.01), whereas the ejection fraction did not differ (-1.2 % at rest, p = 0.20, and -0.9 % after stress, p = 0.27). CONCLUSION: Image quality and LV functional parameters obtained with a one-eighth acquisition time were statistically comparable to the previously validated one-fourth time protocol using IQ-SPECT. Shorter acquisition times without loss of diagnostic accuracy provide improved patient comfort and streamlined departmental efficiency.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
10.
J Nucl Cardiol ; 22(1): 57-65, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25273670

RESUMO

BACKGROUND: We have recently validated a quarter-time protocol in Myocardial Perfusion Imaging named IQ-SPECT, whose basic principle is to implement a multifocal collimator; However, in clinical practice, it may sometimes be difficult to center the heart in the region of highest magnification of the multifocal collimators (the so-called sweet spot). We therefore aimed to evaluate whether a heart mispositioning may affect results in MPI. METHODS: We simulated a rest study with an anthropomorphic phantom with an in vivo distribution of 400 MBq [(99m)Tc]tetrofosmin, with and without a transmural defect (TD). For each set of images, we performed 5 acquisitions, one with a correct centering and with other 4 degrees of mispositioning. Raw data and reconstructed images were evaluated qualitatively and quantitatively, including no corrections, correction for attenuation, for scatter or for both. We assessed polar plot uniformity, LV wall thickness, and TD and cavity contrast. RESULTS: Images obtained either with a correct heart centering or with mild misposition showed no differences, both qualitatively and quantitatively. Those obtained with major mispositioning differed in uniformity and TD contrast depending on correction parameters. CONCLUSION: This is the first study investigating how a heart mispositioning can affect diagnostic accuracy with IQ-SPECT system. Mild-to-moderate mispositioning (≤2.5 cm) is unlikely to significantly affect results.


Assuntos
Imagem de Perfusão do Miocárdio , Posicionamento do Paciente , Tomografia Computadorizada de Emissão de Fóton Único , Antropometria , Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Processamento de Imagem Assistida por Computador , Movimento (Física) , Compostos Organofosforados , Compostos de Organotecnécio , Imagens de Fantasmas , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA