Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 31(23): 38409-38418, 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-38017948

RESUMO

Interband cascade lasers (ICLs) are efficient and compact mid-infrared (3-5 µm) light sources with many applications. By enhancing the coupling coefficient and using a type-I ICL wafer, single-mode ICLs were demonstrated based on V-coupled cavity with significantly extended tuning range and with a side mode suppression ratio (SMSR) exceeding 35 dB in continuous wave operation near 3 µm. A V-coupled cavity ICL exhibited a wavelength tuning up to 67 nm at a fixed temperature, and the total tuning range exceeds 210 nm when the heat sink temperature is adjusted from 80 to 180 K. The realization of single-mode in such a wide temperature range with a tuning range exceeding 210 nm verified the advantage of V-coupled cavity ICLs for effective detection of multiple gas species. This is very different from the conventional distributed feedback (DFB) laser where the single-mode operation is restricted to a narrow temperature range, in which the match between the gain peak and the DFB grating period determined wavelength is required. Another V-coupled cavity ICL is tuned over 120 nm from 2997.56 nm to 3117.50 nm with the heat-sink temperature varied from 210 K to 240 K, over 100 K higher than the previously reported maximum operating temperature for V-coupled cavity ICLs.

2.
Appl Opt ; 58(25): 6906-6911, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31503663

RESUMO

A single-pass, compact, and low-power-consumption methane sensing system is presented, and its sensitivity is examined for a set of reference cells with pressures of 7.4, 74, and 740 Torr and the same methane concentration at laboratory temperature of 23°C. A GaSb-based continuous-wave distributed feedback tunable diode laser at 3270 nm and wavelength modulation spectroscopy were employed to collect 2f spectra in the ν3, R3 band of CH412. The collected 2f spectra were fitted to a modulated Voigt line profile model. An Allan-Werle variance analysis shows that the best detectivity, 4 ppbm, is obtained for the highest pressure cell. At pressures of 74 and 7.4 Torr the detectivities are 16 and 28 ppbm, respectively. For these low-pressure cells, further sensitivity improvements were achieved using a large modulation depth (m>2.2) at the expense of spectral resolution.

3.
Opt Express ; 21(1): 1317-23, 2013 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-23389025

RESUMO

We demonstrate index-coupled distributed-feedback diode lasers at 2.65 µm that are capable of tuning across strong absorption lines of HDO and other isotopologues of H2O. The lasers employ InGaAsSb/AlInGaAsSb multi-quantum-well structures grown by molecular beam epitaxy on GaSb, and single-mode emission is generated using laterally coupled second-order Bragg gratings etched alongside narrow ridge waveguides. We verify near-critical coupling of the gratings by analyzing the modal characteristics of lasers of different length. With an emission facet anti-reflection coating, 2-mm-long lasers exhibit a typical current threshold of 150 mA at 20 °C and are capable of emitting more than 25 mW in a single longitudinal mode, which is significantly higher than the output power reported for loss-coupled distributed-feedback lasers operating at similar wavelengths.

4.
ACS Sens ; 7(2): 564-572, 2022 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-35049276

RESUMO

A challenge for mobile measurement of fugitive methane emissions is the availability of portable sensors that feature high sensitivity and fast response times, simultaneously. A methane gas sensor to measure fugitive emissions was developed using a continuous-wave, thermoelectrically cooled, GaSb-based distributed feedback diode laser emitting at a wavelength of 3.27 µm to probe methane in its strong ν3 vibrational band. Direct absorption spectra (DAS) as well as wavelength-modulated spectra (WMS) of pressure-broadened R(3) manifold lines of methane were recorded through a custom-developed open-path multipass cell with an effective optical path length of 6.8 m. A novel metrological approach was taken to characterize the sensor response in terms of the linearity of different WMS metrics, namely, the peak-to-peak amplitude of the X2f component and the peak and/or the integrated area of the background-subtracted quadrature signal (i.e., Q(2f - 2f0)) and the background-subtracted 1f-normalized quadrature signal (i.e., Q(2f/1f - 2f0/1f0)). Comparison with calibration gas concentrations spanning 1.5 to 40 ppmv indicated that the latter WMS metric showed the most linear response, while fitting DAS provides a traceable reference. In the WMS mode, a sensitivity better than 1 ppbv was achieved at a 1 s integration time. The sensitivity and response time are well-suited to measure enhancements in ambient methane levels caused by fugitive emissions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA