Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Oral Implants Res ; 33(12): 1233-1244, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36184914

RESUMO

OBJECTIVES: Long-term follow-up observations of zirconia implants are rare. This study aimed at evaluating the clinical performance of two-piece zirconia implants in the posterior jaws over 9 years. MATERIALS AND METHODS: Sixty partially edentulous patients were treated with two-piece zirconia implants. In eight no primary stability could be achieved. Fifty-two patients received the final restoration (i.e., cemented fibreglass abutments and all-ceramic crowns). After 2 years, 2 implants failed and 4 dropouts were recorded. The remaining 46 patients with one target implant each were recalled at 9 years. Besides implant survival, clinical parameters at the implant level (plaque index-PI, bleeding on probing-BOP, probing depth-PD, mucosal recession-MR) were recorded and compared with previously collected data. Mechanical and technical complications were assessed. RESULTS: Thirty patients responded. The mean observation period was of 111.1 ± 2.2 months. One implant was lost. Data recorded from the remaining 29 implants were analysed. PI values increased overtime. Mean BOP and PD remained unchanged during follow-up. No additional cases of peri-implantitis were recorded over the 10 diagnosed during the first 2 years of follow-up. No significant changes in mean MR values were detected over time, with 65% of the all included implants exhibiting no recession at 9 years and all the others, but one, a maximum MR of 1 mm. Three technical and 6 mechanical complications occurred in 7 patients between 2- and 9-years (6.9% and 20.7%, respectively, at patient level). CONCLUSION: Within the limitations of the present study, a high survival rate was registered. Albeit frequent mechanical and technical complications, two-piece zirconia implants could represent a valid solution for the replacement of single teeth in the posterior jaws.


Assuntos
Implantes Dentários , Humanos , Estudos de Coortes
2.
Skeletal Radiol ; 41(5): 531-7, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-21701952

RESUMO

OBJECTIVE: To evaluate multidetector CT volumetry in the assessment of bone defect healing in comparison to histopathological findings in an animal model. MATERIALS AND METHODS: In 16 mini-pigs, a circumscribed tibial bone defect was created. Multidetector CT (MDCT) of the tibia was performed on a 64-row scanner 42 days after the operation. The extent of bone healing was estimated quantitatively by MDCT volumetry using a commercially available software programme (syngo Volume, Siemens, Germany).The volume of the entire defect (including all pixels from -100 to 3,000 HU), the nonconsolidated areas (-100 to 500 HU), and areas of osseous consolidation (500 to 3,000 HU) were assessed and the extent of consolidation was calculated. Histomorphometry served as the reference standard. RESULTS: The extent of osseous consolidation in MDCT volumetry ranged from 19 to 92% (mean 65.4 ± 18.5%). There was a significant correlation between histologically visible newly formed bone and the extent of osseous consolidation on MDCT volumetry (r = 0.82, P < 0.0001). A significant negative correlation was detected between osseous consolidation on MDCT and histological areas of persisting defect (r = -0.9, P < 0.0001). CONCLUSION: MDCT volumetry is a promising tool for noninvasive monitoring of bone healing, showing excellent correlation with histomorphometry.


Assuntos
Tomografia Computadorizada Multidetectores/métodos , Osteogênese/fisiologia , Tíbia/diagnóstico por imagem , Tíbia/fisiopatologia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Cicatrização/fisiologia , Animais , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Masculino , Suínos , Tíbia/patologia , Fraturas da Tíbia/patologia
3.
Acad Radiol ; 19(3): 320-5, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22173320

RESUMO

RATIONALE AND OBJECTIVES: To evaluate cone beam computed tomography (CBCT) for monitoring of tibial bone defect healing in comparison to histopathological findings. MATERIALS AND METHODS: Circumscribed tibial bone defects were created in 16 mini-pigs and imaging of the tibia was performed on day 42 using a modern CBCT scanner with flat panel detector (PaX-Duo3D, Vatech, Korea). The extent of osseous consolidation including remaining calcium phosphate granules was measured quantitatively by a CBCT volumetry tool using commercially available software (Osirix Imaging software, Pixmeo, Geneva, Switzerland). Volumes of the entire defect (including all pixels), areas of osseous consolidation (density values >2350) and nonmineralized areas (density values <2350) of the defect were determined. The extent of bone regeneration was determined and correlated with the histomorphometrical reference standard. Independently, a visual semiquantitative CBCT-score was applied (4-point scale) to assess bone defect healing. RESULTS: The extent of osseous consolidation in CBCT volumetry ranged from 14% to 92% (mean, 63.4 ± 17.6%). There was a significant positive correlation between histologically visible newly formed bone and the extent of bone regeneration on CBCT volumetry (r = 0.74-0.79, P < .001). The visual score matched with the volumetric results in 75% of the cases. CONCLUSION: CBCT volumetry allows for reliable, noninvasive quantitative monitoring of bone defect healing and correlates significantly with histological findings. CBCT is a promising technique for imaging of peripheral bones suggesting further evaluation in clinical trials.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Consolidação da Fratura/fisiologia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Animais , Suínos , Porco Miniatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA