Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
Clin Endocrinol (Oxf) ; 101(1): 23-31, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38291597

RESUMO

OBJECTIVE: Plasma copeptin is a relatively new biomarker for evaluation of arginine vasopressin (AVP) secretion. The aim of this study was to test the diagnostic performance of copeptin in patients with polyuria-polydipsia syndrome. DESIGN, PATIENTS AND MEASUREMENTS: This was a prospective study where 88 patients with polyuria-polydipsia syndrome were evaluated with a water deprivation test (WDT). Weight, urine osmolality, urine specific gravity, and plasma copeptin were collected at baseline, after 8 h, and at termination of the WDT when one of the following had been reached: (i) >3% weight reduction, (ii) urine specific gravity >1.017 or urine osmolality >600 mOsm/kg, or (iii) intolerable adverse symptoms. RESULTS: Of 88 patients (57 women), 21 (24%) were diagnosed with central diabetes insipidus (cDI), 5 (6%) with nephrogenic DI (nDI), and 62 (71%) with primary polydipsia (PP). Median (interquartile range) copeptin at baseline was 1.7 (1.4-2.5) pmol/L in cDI, 22 (18-65) pmol/L in nDI, and 2.7 (2-4) pmol/L in PP. After 8 h of WDT, the highest copeptin in patients with cDI was 4.0 pmol/L. In patients with PP: (i) 41 had urine osmolality <600 mOsm/kg, 7 (17%) of these had copeptin >4.0 pmol/L, (ii) 21 had urine osmolality ≥600 mOsm/kg, 14 (67%) of these had copeptin >4.0 pmol/L. CONCLUSIONS: Copeptin >4.0 pmol/L after an overnight WDT can be used to rule out cDI and copeptin ≥21 pmol/L at baseline to diagnose nDI. The diagnostic performance of copeptin in the context of the WDT is otherwise limited in the diagnostic work-up of patients with polyuria-polydipsia syndrome.


Assuntos
Glicopeptídeos , Polidipsia , Poliúria , Humanos , Glicopeptídeos/sangue , Feminino , Masculino , Estudos Prospectivos , Adulto , Poliúria/diagnóstico , Poliúria/sangue , Poliúria/urina , Polidipsia/diagnóstico , Polidipsia/sangue , Pessoa de Meia-Idade , Biomarcadores/sangue , Concentração Osmolar , Adulto Jovem , Privação de Água
2.
Eur Heart J ; 44(2): 100-112, 2023 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-36337034

RESUMO

The use of biomarkers is undisputed in the diagnosis of primary myocardial infarction (MI), but their value for identifying MI is less well studied in the postoperative phase following coronary artery bypass grafting (CABG). To identify patients with periprocedural MI (PMI), several conflicting definitions of PMI have been proposed, relying either on cardiac troponin (cTn) or the MB isoenzyme of creatine kinase, with or without supporting evidence of ischaemia. However, CABG inherently induces the release of cardiac biomarkers, as reflected by significant cTn concentrations in patients with uncomplicated postoperative courses. Still, the underlying (patho)physiological release mechanisms of cTn are incompletely understood, complicating adequate interpretation of postoperative increases in cTn concentrations. Therefore, the aim of the current review is to present these potential underlying mechanisms of cTn release in general, and following CABG in particular (Graphical Abstract). Based on these mechanisms, dissimilarities in the release of cTnI and cTnT are discussed, with potentially important implications for clinical practice. Consequently, currently proposed cTn biomarker cut-offs by the prevailing definitions of PMI might warrant re-assessment, with differentiation in cut-offs for the separate available assays and surgical strategies. To resolve these issues, future prospective studies are warranted to determine the prognostic influence of biomarker release in general and PMI in particular.


Assuntos
Ponte de Artéria Coronária , Infarto do Miocárdio , Humanos , Ponte de Artéria Coronária/efeitos adversos , Infarto do Miocárdio/etiologia , Troponina I , Troponina T , Biomarcadores
3.
Clin Chem Lab Med ; 61(3): 380-387, 2023 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-36424851

RESUMO

OBJECTIVES: Measurement of high-sensitivity (hs) cardiac troponin (cTn) T and I is widely studied for cardiac assessment of stable populations. Recent data suggest clinical and prognostic discrepancies between both hs-cTn. We aimed at reviewing published studies with respect to underlying causes and clinical implications. CONTENT: We summarized current evidence on release and clearance mechanisms of cTnT and I, and on preanalytical and assay-related issues potentially portending to differences in measured concentrations. We also performed a systematic review of outcome studies comparing both hs-cTn in the general population, patients with congestive heart failure, stable coronary artery disease and atrial fibrillation. SUMMARY AND OUTLOOK: For the interpretation of concentrations of hs-cTnT, stronger association with renal dysfunction compared to hs-cTnI should be considered. Hs-cTnT also appears to be a stronger indicator of general cardiovascular morbidity and all-cause mortality. Hs-cTnI concentrations tend to be more sensitive to coronary artery disease and ischemic outcomes. These findings apparently reflect variations in the mechanisms of cardiac affections resulting in cTn release. Whether these differences are of clinically relevance remains to be elucidated. However, having the option of choosing between either hs-cTn might represent an option for framing individualized cardiac assessment in the future.


Assuntos
Doença da Artéria Coronariana , Troponina T , Humanos , Doença da Artéria Coronariana/diagnóstico , Biomarcadores , Troponina I , Coração
4.
Clin Chem Lab Med ; 61(8): 1411-1419, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-36952681

RESUMO

The International Federation of Clinical Chemistry Committee on Clinical Applications of Cardiac Biomarkers (IFCC C-CB) provides educational documents to facilitate the interpretation and use of cardiac biomarkers in clinical laboratories and practice. Our aim is to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay. Measurements of cardiac troponin (cTn) have a prominent place in the clinical work-up of patients with suspected acute coronary syndrome. It is therefore important that clinical laboratories know how to recognize and assess analytical issues. Two emerging analytical issues resulting in falsely high cTn concentrations, often several fold higher than the upper reference limit (URL), are antibody-mediated assay interference due to long-lived cTn-antibody complexes, called macrotroponin, and crosslinking antibodies that are frequently referred to as heterophilic antibodies. We provide an overview of antibody-mediated cTn assay interference and provide recommendations on how to confirm the interference and interpret the results.


Assuntos
Infarto do Miocárdio , Humanos , Biomarcadores , Química Clínica , Anticorpos , Troponina
5.
Biochem Biophys Res Commun ; 594: 57-62, 2022 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-35074586

RESUMO

DNA-damaging agents, such as radiation and chemotherapy, are common in cancer treatment, but the dosing has proven to be challenging, leading to severe side effects in some patients. Hence, to be able to personalize DNA-damaging chemotherapy, it is important to develop fast and reliable methods to measure the resulting DNA damage in patient cells. Here, we demonstrate how single DNA molecule imaging using fluorescence microscopy can quantify DNA-damage caused by the topoisomerase II (TopoII) poison etoposide. The assay uses an enzyme cocktail consisting of base excision repair (BER) enzymes to repair the DNA damage caused by etoposide and label the sites using a DNA polymerase and fluorescently labeled nucleotides. Using this DNA-damage detection assay we find a large variation in etoposide induced DNA-damage after in vitro treatment of blood cells from healthy individuals. We furthermore used the TopoII inhibitor ICRF-193 to show that the etoposide-induced damage in DNA was TopoII dependent. We discuss how our results support a potential future use of the assay for personalized dosing of chemotherapy.


Assuntos
Dano ao DNA/efeitos dos fármacos , DNA Topoisomerases Tipo II/efeitos dos fármacos , DNA de Cadeia Simples/efeitos dos fármacos , DNA de Cadeia Simples/genética , Dicetopiperazinas/farmacologia , Etoposídeo/farmacologia , Imagem Individual de Molécula , Antineoplásicos Fitogênicos/farmacologia , DNA/efeitos dos fármacos , Reparo do DNA , Relação Dose-Resposta a Droga , Humanos , Leucócitos Mononucleares/efeitos dos fármacos , Microscopia de Fluorescência , Inibidores da Topoisomerase II/farmacologia
6.
Clin Chem ; 68(9): 1211-1218, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35802029

RESUMO

BACKGROUND: Few studies are available on how to optimize time points for sampling and how to estimate effects of analytical uncertainty when glomerular filtration rate (GFR) is calculated. METHODS: We explored the underlying regression mathematics of how analytical variation of a kidney filtration marker affects 1-compartment, slope-and-intercept GFR calculations, using 2 or 3 time points following a bolus injection, and used this to examine the results from 731 routine 3-point iohexol plasma clearance measurements. RESULTS: GFR calculations inflated analytical uncertainty if the time points were taken too late after the bolus injection and too close after each other. The uncertainty in GFR calculation was, however, the same as the analytical uncertainty if optimal time points were used. The middle of the 3 samples was of little value. The first sample should be taken as early as possible after the distribution phase. Sampling before the patient specific half-life of the kidney filtration marker resulted in an exponential error inflation whereas no error inflation was seen when sampling occurred later than 2 half-lives. Theoretical GFR uncertainty could be lowered 2.6-fold if individually optimized time points for sampling had been used in our 731 clearance measurements. Using Taylor expansions to approximate the moments of transformed random variables, the uncertainty of an individual GFR measurement could be calculated in a simple enough way to be applicable by laboratory software. CONCLUSIONS: We provide a theoretical foundation to select patient-optimal time points that may both limit errors and allow calculation of GFR uncertainty.


Assuntos
Iohexol , Nefropatias , Biomarcadores , Taxa de Filtração Glomerular , Humanos , Testes de Função Renal/métodos
7.
Clin Chem ; 68(8): 1022-1030, 2022 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-35716089

RESUMO

The International Federation of Clinical Chemistry Committee on Clinical Application of Cardiac Bio-Markers provides evidence-based educational documents to facilitate uniform interpretation and utilization of cardiac biomarkers in clinical laboratories and practice. The committee's goals are to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay in clinical practice. Measurement of high-sensitivity cardiac troponin (hs-cTn) assays is a cornerstone in the clinical evaluation of patients with symptoms and/or signs of acute cardiac ischemia. To define myocardial infarction, the Universal Definition of Myocardial Infarction requires patients who manifest with features suggestive of acute myocardial ischemia to have at least one cTn concentration above the sex-specific 99th percentile upper reference limit (URL) for hs-cTn assays and a dynamic pattern of cTn concentrations to fulfill the diagnostic criteria for MI. This special report provides an overview of how hs-cTn 99th percentile URLs should be established, including recommendations about prescreening and the number of individuals required in the reference cohort, how statistical analysis should be conducted, optimal preanalytical and analytical protocols, and analytical/biological interferences or confounds that can affect accurate determination of the 99th percentile URLs. This document also provides guidance and solutions to many of the issues posed.


Assuntos
Infarto do Miocárdio , Isquemia Miocárdica , Bioensaio , Biomarcadores , Química Clínica , Feminino , Humanos , Masculino , Infarto do Miocárdio/diagnóstico , Troponina/análise , Troponina T
8.
Biomarkers ; 27(5): 407-417, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35603440

RESUMO

PURPOSE: This review intends to illustrate basic principles on how to apply the Fourth Universal Definition of Myocardial Infarction (UDMI) for the diagnosis of peri-procedural myocardial infarction (MI) after percutaneous coronary interventions (PCI) in clinical practice. METHODS AND RESULTS: Review of routine case-based events. Increases in cardiac troponin (cTn) concentrations are common after elective PCI in patients with chronic coronary syndrome (CCS). Peri-procedural PCI-related MI (type 4a MI) in CCS patients should be diagnosed in cases of major peri-procedural acute myocardial injury indicated by an increase in cTn concentrations of >5-times the 99th percentile upper reference limit (URL) together with evidence of new peri-procedural myocardial ischaemia as demonstrated by electrocardiography (ECG), imaging, or flow-limiting peri-procedural complications in coronary angiography. Measurement of cTn baseline concentrations before elective PCI is useful. In patients presenting with acute MI undergoing PCI, peri-procedural increases in cTn concentrations are usually due to their index presentation and not PCI-related, apart from obvious major peri-procedural complications, such as persistent occlusion of a large side branch or no-reflow after stent implantation. CONCLUSION: The distinction between type 4a MI, PCI-related acute myocardial injury, and chronic myocardial injury can be challenging in individuals undergoing PCI. Careful integration of all available clinical data is essential for correct classification.


Assuntos
Cardiologia , Infarto do Miocárdio , Intervenção Coronária Percutânea , Biomarcadores , Angiografia Coronária/efeitos adversos , Humanos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/efeitos adversos
9.
Clin Chem ; 67(1): 107-113, 2021 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-33045044

RESUMO

BACKGROUND: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that emerged late in 2019 causing COVID-19 (coronavirus disease-2019) may adversely affect the cardiovascular system. Publications from Asia, Europe, and North America have identified cardiac troponin as an important prognostic indicator for patients hospitalized with COVID-19. We recognized from publications within the first 6 months of the pandemic that there has been much uncertainty on the reporting, interpretation, and pathophysiology of an increased cardiac troponin concentration in this setting. CONTENT: The purpose of this mini-review is: a) to review the pathophysiology of SARS-CoV-2 and the cardiovascular system, b) to overview the strengths and weaknesses of selected studies evaluating cardiac troponin in patients with COVID-19, and c) to recommend testing strategies in the acute period, in the convalescence period and in long-term care for patients who have become ill with COVID-19. SUMMARY: This review provides important educational information and identifies gaps in understanding the role of cardiac troponin and COVID-19. Future, properly designed studies will hopefully provide the much-needed evidence on the path forward in testing cardiac troponin in patients with COVID-19.


Assuntos
COVID-19/sangue , Troponina/sangue , Biomarcadores/sangue , COVID-19/complicações , COVID-19/epidemiologia , COVID-19/virologia , Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/complicações , Doenças Cardiovasculares/diagnóstico , Humanos , Pandemias , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
10.
Biomarkers ; 26(5): 410-416, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33906551

RESUMO

BACKGROUND: Elevated levels of high-sensitive cardiac troponin T (hs-cTnT) are linked to poor prognosis among emergency department (ED) patients. OBJECTIVE: Examine the effect of our ED risk assessment among patients with suspected acute coronary syndrome (ACS) and elevated baseline hs-cTnT levels. DESIGN: Observational cohort study of 16776 ED patients with chest pain or dyspnoea and a hs-cTnT sample analyzed at the time of the ED visit. Of these 1480 patients were sent home with elevated hs-cTnT levels (>14 ng/L). METHODS: Analysis of clinical and laboratory data from the local hospital and data from the National Board of Health and Welfare. RESULTS: Admitted patients had 11% and discharged patients had 1.2% 90-day mortality indicating effective risk assessment of patients with suspected ACS. However, if the suspected ACS patient presented with hs-cTnT between 14 and 22 ng/L, the 90-day mortality was 4.1% among discharged and 6.7% among admitted patients. Among discharged patients, an hs-cTnT level above 14 ng/L was a higher independent risk factor for 90-day mortality (HR 3.3, 95% CI 2.9-3.7, p < 0.001) than if the patient was triaged as a high-risk patient (HR 1.6, 95% CI 1.1-1.8, p < 0.001). CONCLUSIONS: Our ED risk assessment was less effective among patients presenting with elevated hs-cTnT levels.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Angina Pectoris/diagnóstico , Técnicas de Apoio para a Decisão , Serviço Hospitalar de Emergência , Alta do Paciente , Triagem , Troponina T/sangue , Síndrome Coronariana Aguda/sangue , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Angina Pectoris/sangue , Angina Pectoris/mortalidade , Angina Pectoris/terapia , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Admissão do Paciente , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Regulação para Cima
11.
Clin Chem ; 66(2): 333-341, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32040581

RESUMO

BACKGROUND: Although cardiac troponin I (cTnI) and troponin T (cTnT) form a complex in the human myocardium and bind to thin filaments in the sarcomere, cTnI often reaches higher concentrations and returns to normal concentrations faster than cTnT in patients with acute myocardial infarction (MI). METHODS: We compared the overall clearance of cTnT and cTnI in rats and in patients with heart failure and examined the release of cTnT and cTnI from damaged human cardiac tissue in vitro. RESULTS: Ground rat heart tissue was injected into the quadriceps muscle in rats to simulate myocardial damage with a defined onset. cTnT and cTnI peaked at the same time after injection. cTnI returned to baseline concentrations after 54 h, compared with 168 h for cTnT. There was no difference in the rate of clearance of solubilized cTnT or cTnI after intravenous or intramuscular injection. Renal clearance of cTnT and cTnI was similar in 7 heart failure patients. cTnI was degraded and released faster and reached higher concentrations than cTnT when human cardiac tissue was incubated in 37°C plasma. CONCLUSION: Once cTnI and cTnT are released to the circulation, there seems to be no difference in clearance. However, cTnI is degraded and released faster than cTnT from necrotic cardiac tissue. Faster degradation and release may be the main reason why cTnI reaches higher peak concentrations and returns to normal concentrations faster in patients with MI.


Assuntos
Infarto do Miocárdio/metabolismo , Troponina I/metabolismo , Troponina T/metabolismo , Animais , Biomarcadores/sangue , Insuficiência Cardíaca/sangue , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Miocárdio/metabolismo , Ratos , Ratos Endogâmicos WKY , Sarcômeros/metabolismo , Troponina I/sangue , Troponina T/sangue
12.
Biomarkers ; 25(4): 322-330, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32362195

RESUMO

Purpose: The Fourth Universal Definition of Myocardial Infarction (MI) has highlighted the different pathophysiological mechanisms that may lead to ischaemic and non-ischaemic myocardial injury and has emphasised that the diagnosis of myocardial infarction requires the presence of acute myocardial ischaemia in the setting of acute myocardial injury. This case based review intends to illustrate basic principles on how to apply this new, revised definition in clinical practice.Methods and Results: The distinction between different types of MIs (type 1 or type 2) and the delineation of MI from acute non-ischaemic myocardial injury may be challenging in individual patients, which is illustrated by presenting and discussing real-life routine cases.Conclusions: Type 1 MI is a consequence of coronary plaque rupture or erosion with intracoronary thrombus formation that is usually apparent on coronary angiography. Plausible triggering mechanisms causing myocardial oxygen supply/demand mismatch must be identified for the diagnosis of type 2 MI and its treatment should focus initially on management of the underlying disease attributable to acute myocardial ischaemia.


Assuntos
Infarto do Miocárdio/sangue , Isquemia Miocárdica/sangue , Troponina I/sangue , Troponina T/sangue , Síndrome Coronariana Aguda/sangue , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Eletrocardiografia , Feminino , Traumatismos Cardíacos/sangue , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/fisiopatologia , Humanos , Masculino , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Isquemia Miocárdica/diagnóstico por imagem , Miocárdio/patologia
13.
Biomarkers ; 23(8): 725-734, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29976112

RESUMO

Cardiac-specific troponins are elevated in blood following cardiac injury and are the preferred diagnostic biomarkers when acute myocardial infarction is suspected clinically. Cardiac troponin (cTn) elevations are also observed in clinical conditions without obvious connection to cardiac injury. Irrespective of the underlying condition, cTn elevation is linked to a poor prognosis, even if the elevation is stable over time. Here, we explore mechanisms that may lead to cTn elevations, including necrosis, apoptosis, necroptosis, cell wounds and decreased clearance. The aim is to broaden the perspective of how we interpret unexpected cTn elevations in patients. The cTn elevations may not be able to serve as direct proof of myocardial necrosis especially in the absence of a clear-cut reason for its release. Abbreviations: AMI: acute myocardial infarction; cTn: cardiac troponin; cTnI: cardiac troponin I; cTnT: cardiac troponin T; MLKL: mixed lineage kinase domain-like; TUNEL: terminal deoxynucleotidyl transferase nick end labeling.


Assuntos
Traumatismos Cardíacos/sangue , Infarto do Miocárdio/sangue , Troponina/sangue , Apoptose , Biomarcadores/sangue , Traumatismos Cardíacos/diagnóstico , Traumatismos Cardíacos/patologia , Humanos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/patologia , Necrose , Prognóstico , Troponina C/sangue , Troponina I/sangue , Troponina T/sangue
15.
Clin Chem Lab Med ; 60(3): 68-70, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35007413
16.
Exp Cell Res ; 344(1): 120-131, 2016 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-27108928

RESUMO

Radiotherapy of thyroid cancer with I-131 is abrogated by inherent loss of radioiodine uptake due to loss of sodium iodide symporter (NIS) expression in poorly differentiated tumor cells. It is also known that ionizing radiation per se down-regulates NIS (the stunning effect), but the mechanism is unknown. Here we investigated whether loss of NIS-mediated iodide transport may be elicited by DNA damage. Calicheamicin, a fungal toxin that specifically cleaves double-stranded DNA, induced a full scale DNA damage response mediated by the ataxia-telangiectasia mutated (ATM) kinase in quiescent normal thyrocytes. At sublethal concentrations (<1nM) calicheamicin blocked NIS mRNA expression and transepithelial iodide transport as stimulated by thyrotropin; loss of function occurred at a much faster rate than after I-131 irradiation. KU-55933, a selective ATM kinase inhibitor, partly rescued NIS expression and iodide transport in DNA-damaged cells. Prolonged ATM inhibition in healthy cells also repressed NIS-mediated iodide transport. ATM-dependent loss of iodide transport was counteracted by IGF-1. Together, these findings indicate that NIS, the major iodide transporter of the thyroid gland, is susceptible to DNA damage involving ATM-mediated mechanisms. This uncovers novel means of poor radioiodine uptake in thyroid cells subjected to extrinsic or intrinsic genotoxic stress.


Assuntos
Dano ao DNA , Simportadores/metabolismo , Aminoglicosídeos/farmacologia , Animais , Proteínas Mutadas de Ataxia Telangiectasia/antagonistas & inibidores , Proteínas Mutadas de Ataxia Telangiectasia/metabolismo , Transporte Biológico/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Eletrólitos/metabolismo , Epitélio/efeitos dos fármacos , Epitélio/metabolismo , Fator de Crescimento Insulin-Like I/farmacologia , Iodetos/metabolismo , Sus scrofa , Simportadores/genética , Glândula Tireoide/citologia , Tireotropina/farmacologia
20.
Nephrol Dial Transplant ; 31(7): 1182-9, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26410886

RESUMO

BACKGROUND: In organ transplanted patients, impaired renal function is of major prognostic importance and influences therapeutic decisions. Therefore, monitoring of renal function with glomerular filtration rate (GFR) is of importance, both before and after heart transplantation (HTx). The GFR can be measured directly (mGFR) or estimated (eGFR) with equations based on circulating creatinine or cystatin C levels. However, these equations have not been thoroughly validated in the HTx population. METHODS: We investigated the correlation, agreement and accuracy between mGFR (using (51)Cr-ethylenediaminetetraacetic acid or iohexol clearance) and three commonly used eGFR equations (Modification of Diet in Renal Disease, Cockcroft-Gault and Chronic Kidney Disease Epidemiology Collaboration) in a retrospective analysis of 416 HTx recipients followed between 1988 and 2012. Comparisons were performed prior to transplantation and at 1, 5 and 10 years of follow-up. RESULTS: The correlations between eGFR and mGFR were only moderate, with r-values ranging from 0.55 preoperatively to 0.82 during follow-up. Most importantly, the level of agreement between eGFR and mGFR was very low for all three estimates, with percentage errors ranging from 93.3 to 157.3%. Also, the percentage of patients with eGFR within 30% of mGFR (P30) rarely reached the National Kidney Foundation recommended minimum level of 75%. CONCLUSION: We argue that the accuracy and the precision of the most commonly used estimation equations for assessment of kidney function are unacceptably low and we believe that mGFR should be used liberally as the basis for clinical decision-making both before and after HTx when eGFR is subnormal.


Assuntos
Taxa de Filtração Glomerular , Rim/fisiopatologia , Insuficiência Renal/diagnóstico , Adolescente , Adulto , Idoso , Creatinina/sangue , Feminino , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Insuficiência Renal/sangue , Insuficiência Renal/mortalidade , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA