Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Biomimetics (Basel) ; 8(1)2023 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-36810403

RESUMO

Drug-eluting stents (DES) demonstrated superior efficacy when compared to bare metal stents and plain-old balloon angioplasty and are nowadays used in almost all percutaneous revascularization procedures. The design of the stent platforms is constantly improving to maximize its efficacy and safety. Constant development of DES includes adoption of new materials used for scaffold production, new design types, improved overexpansion abilities, new polymers coating and, finally, improved antiproliferative agents. Especially nowadays, with the immense number of available DES platforms, it is crucial to understand how different aspects of stents impact the effect of their implantation, as subtle differences between various stent platforms could impact the most important issue-clinical outcomes. This review discusses the current status of coronary stents and the impact of stent material, strut design and coating techniques on cardiovascular outcomes.

2.
J Cardiovasc Dev Dis ; 10(9)2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37754828

RESUMO

Robots are defined as programmable machines that can perform specified tasks. Medical robots are emerging solutions in the field of cardiology leveraging recent technological innovations of control systems, sensors, actuators, and imaging modalities. Robotic platforms are successfully applied for percutaneous coronary intervention, invasive cardiac electrophysiology procedures as well as surgical operations including minimally invasive aortic and mitral valve repair, coronary artery bypass procedures, and structural heart diseases. Furthermore, machines are used as staff-assisting tools to support nurses with repetitive clinical duties i.e., food delivery. High precision and resolution allow for excellent maneuverability, enabling the performance of medical procedures in challenging anatomies that are difficult or impossible using conventional approaches. Moreover, robot-assisted techniques protect operators from occupational hazards, reducing exposure to ionizing radiation, and limiting risk of orthopedic injuries. Novel automatic systems provide advantages for patients, ensuring device stability with optimized utilization of fluoroscopy. The acceptance of robotic technology among healthcare providers as well as patients paves the way for widespread clinical application in the field of cardiovascular medicine. However, incorporation of robotic systems is associated with some disadvantages including high costs of installation and expensive disposable instrumentations, the need for large operating room space, and the necessity of dedicated training for operators due to the challenging learning curve of robotic-assisted interventional systems.

3.
Postepy Kardiol Interwencyjnej ; 19(4): 359-366, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38187482

RESUMO

Introduction: Indications for transcatheter aortic valve implantation (TAVI) continue to expand. Very often TAVI must be done in large annuli. Implantation of the bigger prostheses is often associated with more procedural problems, which may affect the outcomes. Aim: To compare the outcomes of TAVI procedures using the self-expandable Medtronic Evolut R 34 with the smaller Evolut R or Evolut Pro 23, 26 or 29. Material and methods: We analysed 87 patients who received self-expandable Medtronic Evolut R and Pro valves. Group I consisted of 59 (67.81%) patients with Evolut 23, 26 or 29, and group II consisted of 28 (32.18%) patients who received an Evolut 34 valve. Results: EuroSCORE II was 5.59 in group I vs 7.87 in group II (p = 0.02). The oversizing rate was higher in group II: 24.1% vs. 18.5% (p < 0.001). The procedure and fluoroscopy times were longer in group II: 209 vs. 187 min (p = 0.03), 44 vs. 27 min (p = 0.01). Moderate paravalvular leak was found more frequently in group II: 5 v 1 (p = 0.04). There was less device success in group II: 22 (78.57%) vs. 57 (96.6%) (p = 0.05). Early safety criteria were similar in both groups: 52 (88.1%) and 24 (92.3%) (p = 0.56). 30-day mortality was similar: 4 (6.7%) vs. 0 in group I and II respectively (p = 0.16). Conclusions: TAVI procedures in patients requiring an Evolut R 34 prosthesis are more challenging than in those who need smaller valves. Paravalvular leaks are more frequently observed after TAVI with Evolut R 34, which results in lower device success.

4.
Arch Rheumatol ; 37(4): 495-503, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36879576

RESUMO

Objectives: This study aims to assess variables concerning arterial stiffness including carotid-femoral pulse wave velocity, carotid-radial pulse wave velocity, ankle-brachial index, and the advancement of atherosclerosis development. Patients and methods: Between October 2016 and December 2020, a total of 43 consecutive patients with systemic lupus erythematosus (SLE) (4 males, 39 females; mean age: 57±8 years; range, 42 to 65 years) were prospectively included in the study. All data were compared between the group treated with glucocorticoids and that not treated with these agents. Results: The study group consisted of 43 patients with SLE, while 22 (51%) patients were treated with glucocorticoids. The mean duration of SLE was 12.3±5.3 years. Patients treated with glucocorticoids had lower values of ankle-brachial index compared to those who were not treated with glucocorticoids (p=0.041), although the values were within the range. A similar situation was reported for the carotid-femoral artery pulse wave velocity (p=0.032). However, carotid-radial artery pulse wave velocity was not significantly different between both groups (p=0.12). Conclusion: Properly selected therapy is important in the prevention of CVD.

5.
Cardiol Res Pract ; 2020: 7025329, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33204527

RESUMO

Systemic lupus erythematosus is a rare autoimmune disease. It leads to an increased production of proinflammatory molecules that accelerates atherogenesis and could cause an endothelium dysfunction. The aim of the study was to assess cardiovascular risk factors such as BMI and lipid profile as well as left ventricular ejection fraction among patients with SLE, and a correlation of these factors with duration of the disease. Materials and Methods. The researched group consisted of patients with SLE, being under control of the outpatient clinic of cardiology. This group included 38 patients among whom 34 were women (56.17 ± 11.05 years) and 4 were men (65.50 ± 9.22 years). The control group consisted of 19 healthy women (53.31 ± 11.94 years) and 2 healthy men (38.51 ± 7.53 years). Measurements were taken in the same conditions by trained medical staff. Results. Excessive body weight (BMI >25 kg/m2) was more frequent in the SLE group, but it was not statistically significant (55.26% vs. 52.38%, p=0.6159). LVEF values were lower in their searched group, and this factor showed statistical significance (53.92% ± 6.46 vs. 58.67% ± 4.69, p=0.0044). Thickness of the IMT was higher and statistically important among patients with SLE, both in left (1.22 ± 0.27 mm vs. 0.7 ± 0.21 mm, p=0.0001) and right common carotid artery (1.16 ± 0.26 mm vs. 0.59 ± 0.15 mm, p=0.0001), compared to the controls. Conclusions. Patients with SLE are at greater risk of developing cardiovascular diseases as the illness progresses. The activity of the disease according to the SLEDAI-2K scale may have an impact on the LVEF values which was significantly decreased in the group with active disease, but further thorough investigation is required to fully evaluate the impact of individual components of the disease and its treatment on the CVD development and mortality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA