Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiol ; 80(4): 365-372, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35725947

RESUMO

BACKGROUND: Patients with heart failure (HF) often complain of sleep discomfort. Previous reports described that difficulty initiating sleep increased the cardiovascular risk in the general population. However, the association between difficulty initiating sleep and cardiac function in patients with HF remains unclear. This study aimed to investigate the associations between difficulty initiating sleep and clinical characteristics and cardiac function in patients with HF. METHODS: Eighty-seven patients with HF who underwent overnight polysomnography for suspected sleep-disordered breathing were included. Patients were divided into two groups of the longer sleep latency (SL) group (SL ≥14 min, n = 44) and the shorter SL group (SL <14 min, n = 43). The median value of SL was defined as the time from lights-off to falling asleep. We compared the patients' characteristics, laboratory data, and polysomnographic and echocardiographic indices between the two groups. RESULTS: The patients' median age was 67 years, and 85.1 % were men. There was lower beta blocker use [25 (56.8 %) vs. 34 (79.1 %), p = 0.046] and a higher peak mitral early filling velocity to mitral annular velocity ratio (E/e') [16.5 (14.2-21.7) vs. 13.7 (10.9-16.2), p = 0.005] in the longer SL group than in the shorter SL group. In multivariate logistic analysis, E/e' (odds ratio: 1.10, 95 % confidence interval: 1.01 to 1.19; p = 0.032) and systolic blood pressure before sleeping (odds ratio: 1.05, 95 % confidence interval: 1.00 to 1.10; p = 0.033) were significantly associated with a longer SL in patients with HF. CONCLUSIONS: Increased left atrial pressure suggested by increased E/e' and increased systolic blood pressure before sleeping is independently associated with difficulty initiating sleep in patients with HF. Management of these hemodynamic imbalances is required to improve difficulty initiating sleep in patients with HF.


Assuntos
Pressão Atrial , Insuficiência Cardíaca , Idoso , Ecocardiografia , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Valva Mitral , Sono , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia
2.
Laryngoscope Investig Otolaryngol ; 2(6): 390-394, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29299513

RESUMO

Objectives: To clarify the usefulness of ultrasonography for detecting hypopharyngeal cancer. Study Design: Cross-sectional study. Methods: The study included 95 patients who underwent pre-treatment ultrasonography. We evaluated the usefulness of ultrasonography for detecting primary hypopharyngeal carcinoma of each T stage and subsite, and for assessing extrahypopharyngeal invasion. Additionally, we determined the efficacy of color Doppler for evaluating primary hypopharyngeal carcinoma. Results: The patients comprised 93 men and 2 women with a mean age of 67.5 years. The T stage (primary tumors) was T1 in 29 patients, T2 in 22, T3 in 9, and T4 in 35. Primary sites with a T stage over T3 were detected using ultrasonography in 17 patients.Regarding primary subsites, postcricoid tumors were assessed most easily (64%), while posterior wall tumors were the most difficult to assess (25%). In 15 of 17 patients, the evaluation of extrahypopharyngeal invasion by ultrasonography matched up precisely with computed tomography findings. In addition, abnormally increased blood flow in primary hypopharyngeal cancers was recognized by color Doppler, and could be used to predict subsites. Conclusions: Cancers at T3 and T4 hypopharyngeal primary tumors and their extrahypopharyngeal invasion were detectable using ultrasonography. Furthermore, ultrasonography was useful for assessing postcricoid tumors that were difficult to observe by flexible laryngoscopy. Level of Evidence: 4.

3.
Yonago Acta Med ; 59(4): 255-261, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28070162

RESUMO

BACKGROUND: The therapeutic effect of chemotherapy for liver metastases is currently determined by changes in tumor diameter depicted on computed tomography (CT) and magnetic resonance imaging, but it cannot accurately determine if there is central necrosis. Furthermore, due to the risk of radiation exposure and high cost, frequent examination using these methods places a heavy burden on patients. Meanwhile, real-time observation of blood flow and vessel morphology within tumors has become possible by contrast-enhanced ultrasonography (CEUS). However, use of CEUS in evaluating the therapeutic effect of anticancer chemotherapy has rarely been investigated. This study investigated whether changes in the time-intensity curve (TIC) of CEUS are useful indicators of the therapeutic effect of chemotherapy. METHODS: Five patients with liver metastases who had undergone CEUS before and after chemotherapy were included in this study. The TIC of each time point was prepared to examine whether the following five TIC parameters serve as indicators of the therapeutic effect of chemotherapy: peak intensity, time to wash-in, time to peak intensity, slope of wash-in, and area under the curve. In each parameter, rate of change (ROC) was calculated by the expression [(values before chemotherapy minus those after chemotherapy)/those before chemotherapy × 100(%)]. RESULTS: (i) Among the five TIC parameters tested, ROC of the slope of wash-in and the area under the curve reflected the therapeutic effect of chemotherapy better than the remaining three parameters. (ii) TIC parameters after one cycle of chemotherapy were examined in two of five patients, and changes in the slope of wash-in and the area under the curve were in good agreement with the computed tomography findings indicative of the therapeutic effect after the fourth chemotherapy cycle. CONCLUSION: The findings of this study suggest that ROC of the slope of wash-in and the area under the curve of the TIC are useful in evaluating the therapeutic effect of chemotherapy. Furthermore, there is a possibility that TIC analysis may enable early prediction of the therapeutic effect.

4.
Yonago Acta Med ; 59(2): 163-8, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27493488

RESUMO

BACKGROUND: Breast ultrasound findings regarding tumor margins are crucial in judging whether a tumor is malignant or benign. However, the relationships between the margins and clinicopathological characteristics remain largely unknown. In this study, we examined the clinicopathological characteristics of patients with invasive ductal carcinoma whose ultrasound images showed either well-defined and rough or indistinct margins. METHODS: Of all consecutive patients diagnosed with invasive ductal carcinoma at the Division of Breast and Endocrine Surgery of Tottori University Hospital from January 2012 to December 2014, 122 patients whose ultrasound images showed either "well-defined and rough" or "indistinct" tumor margins were included in this study. Mammography and ultrasound images taken at the initial examination were reviewed. Patients were divided into two groups based on ultrasound findings of the tumor margins: the "well-defined and rough group" and the "indistinct group." The relationships among ultrasound findings, mammography findings and clinicopathological findings were investigated in the two groups. RESULTS: The well-defined and rough group was more likely to contain solid-tubular carcinoma, while the indistinct group was more likely to contain scirrhous carcinoma. The MIB-1 index was higher in the well-defined and rough group than in the indistinct group. Additionally, the proportion of patients with nuclear grade 3, estrogen receptor-negative/progesterone receptor-negative, and triple-negative breast cancer was greater in the well-defined and rough group than in the indistinct group. CONCLUSION: Invasive ductal carcinomas with well-defined and rough margins on ultrasound were likely to be malignant and proliferative than those with indistinct margins.

5.
Yonago Acta Med ; 59(2): 169-73, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27493489

RESUMO

BACKGROUND: Attention deficit disorder/hyperactivity disorder (ADHD) is a pathological condition that is not fully understood. In this study, we investigated electroencephalographic (EEG) power differences between children with ADHD and healthy control children. METHODS: EEGs were recorded as part of routine medical care received by 80 children with ADHD aged 4-15 years at the Department of Pediatric Neurology in Tottori University Hospital. Additionally, we recorded in 59 control children aged 4-15 years after obtaining informed consent. Specifically, awake EEG signals were recorded from each child using the international 10-20 system, and we used ten 3-s epochs on the EEG power spectrum to calculate the powers of individual EEG frequency bands. RESULTS: The powers of different EEG bands were significantly higher in the frontal brain region of those in the ADHD group compared with the control group. In addition, the power of the beta band in the ADHD group was significantly higher in all brain regions, except for the occipital region, compared with control children. With regard to developmental changes, the power of the alpha band in the occipital region showed an age-dependent decrease in both groups, with slightly lower power in the ADHD group. Additionally, the intergroup difference decreased in children aged 11 years or older. As with the alpha band in the occipital region, the beta band in the frontal region showed an age-dependent decrease in both groups. Unlike the alpha band, the power of the beta band was higher in the ADHD group than in the control group for children of all ages. CONCLUSION: The observed intergroup differences in EEG power may provide insight into the brain function of children with ADHD.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA