Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 148(1): 35-46, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37199171

RESUMO

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Flutter Atrial/etiologia , Sistema de Registros , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
2.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38647070

RESUMO

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Técnicas de Sutura , Humanos , Fibrilação Atrial/cirurgia , Feminino , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Técnicas de Sutura/efeitos adversos , Idoso , Resultado do Tratamento , Alemanha , Fatores de Tempo , Dispositivos de Oclusão Vascular , Deambulação Precoce , Técnicas Hemostáticas/instrumentação
3.
Catheter Cardiovasc Interv ; 101(3): 610-619, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36682074

RESUMO

BACKGROUND: Left atrial appendage closure (LAAC) has emerged as an alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF). OAC treatment has been proven feasible in mild-to-moderate chronic kidney disease (CKD). In contrast, the optimal antithrombotic management of AF patients with end-stage renal disease (ESRD) is unknown and LAAC has not been proven in these patients in prospective randomized clinical trials. OBJECTIVES: The objective of this study is to evaluate safety and efficacy of LAAC in patients with ESRD. METHODS: Patients undergoing LAAC were collected in a German multicenter real-world observational registry. A composite endpoint consisting of the occurrence of ischemic stroke/transient ischemic attack, systemic embolism, and/or major clinical bleeding was assessed. Patients with ESRD were compared with propensity score-matched patients without severe CKD. ESRD was defined as a glomerular filtration rate < 15 ml/min/1.73 m2 or chronic hemodialysis treatment. RESULTS: A total of 604 patients were analyzed, including 57 with ESRD and 57 propensity-matched patients. Overall, 596 endocardial and 8 epicardial LAAC procedures were performed. Frequency of major complications was 7.0% (42/604 patients) in the overall cohort, 8.8% (5/57 patients) in patients with ESRD, and 10.5% (6/57 patients) in matched controls (p = 0.75). The estimated event-free survival of the combined endpoint after 500 days was 90.7 ± 4.5% in patients with ESRD and 90.2 ± 5.5% in matched controls (p = 0.33). CONCLUSIONS: LAAC had comparable procedural safety and clinical efficacy in patients with ESRD and patients without severe CKD.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Falência Renal Crônica , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Apêndice Atrial/diagnóstico por imagem , Estudos Prospectivos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Sistema de Registros , Anticoagulantes/efeitos adversos
4.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37589146

RESUMO

AIMS: Catheter ablation with a cryoballoon (CB) provides effective and durable pulmonary vein (PV) isolation (PVI) associated with encouraging clinical outcome data. The novel POLARx CB incorporates unique features, which may translate into improved safety, efficacy, and outcomes. The ICE-AGE-1 study aimed to assess the efficacy, safety, and 1-year clinical follow-up of the POLARx CB in comparison to the Arctic Front Advance Pro CB (AF-CB4). METHODS AND RESULTS: A total of 103 consecutive patients with paroxysmal or persistent atrial fibrillation (AF) who underwent POLARx-based PVI (POLARx group) were prospectively enrolled and were compared to 102 consecutive patients previously treated with the AF-CB4 (AF-CB4 group). The mean age was 68.7 ± 10.2 (POLARx) and 65.7 ± 12 (AF-CB4, P = 0.0551) years. A total of 412 (POLARx) and 404 (AF-CB4) PVs were identified. All PVs, except for one PV in the POLARx group, were successfully isolated. A significant difference regarding the mean minimal CB temperature reached using the POLARx CB (-56.1 ± 8.3°C) and AF-CB4 (-46.9 ± 10.1°C) was observed (P < 0.0001). Real-time PVI was visualized in 71% of PVs in the POLARx group and 46% of them in the AF-CB4 group (P < 0.001). The mean procedure time was comparable: 54.5 ± 17.1 min for POLARx and 59.4 ± 18.6 min for AF-CB4 (P = 0.0509). No differences were observed in terms of periprocedural complications. There were comparable rates in freedom of AF or atrial tachycardia recurrence after 12 months, beyond a 90-day long blanking period: 78.9% in the POLARx group vs. 77.2% in the AF-CB4 group (P = 0.804). CONCLUSION: The novel POLARx CB showed similar safety, efficacy, and 1-year recurrence-free survival rates compared to the AF-CB4. A higher rate of real-time electrical PV recordings and significantly lower balloon temperatures were observed using the POLARx as compared to AF-CB4.


Assuntos
Ablação por Cateter , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Lactente , Veias Pulmonares/cirurgia , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Temperatura
5.
Europace ; 25(2): 600-609, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36504238

RESUMO

AIMS: Accessory pathway (AP) ablation is a standard procedure for the treatment of Wolff-Parkinson-White syndrome (WPW). Twelve-lead electrocardiogram (ECG)-based delta wave analysis is essential for predicting ablation sites. Previous algorithms have shown to be complex, time-consuming, and unprecise. We aimed to retrospectively develop and prospectively validate a new, simple ECG-based algorithm considering the patients' heart axis allowing for exact localization of APs in patients undergoing ablation for WPW. METHODS AND RESULTS: Our multicentre study included 211 patients undergoing ablation of a single manifest AP due to WPW between 2013 and 2021. The algorithm was developed retrospectively and validated prospectively by comparing its efficacy to two established ones (Pambrun and Arruda). All patients (32 ± 19 years old, 47% female) underwent successful pathway ablation. Prediction of AP-localization was correct in 197 patients (93%) (sensitivity 92%, specificity 99%, PPV 96%, and NPV 99%). Our algorithm was particularly useful in correctly localizing antero-septal/-lateral (sensitivity and specificity 100%) and posteroseptal (sensitivity 98%, specificity 92%) AP in proximity to the tricuspid valve. The accuracy of EASY-WPW was superior compared to the Pambrun (93% vs. 84%, P = 0.003*) and the Arruda algorithm (94% vs. 75%, P < 0.001*). A subgroup analysis of children (n = 58, 12 ± 4 years old, 55% female) revealed superiority to the Arruda algorithm (P < 0.001*). The reproducibility of our algorithm was excellent (Ï°>0.8; P < 0.001*). CONCLUSION: The novel EASY-WPW algorithm provides reliable and accurate pre-interventional ablation site determination in WPW patients. Only two steps are necessary to locate left-sided AP, and three steps to determine right-sided AP.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndrome de Wolff-Parkinson-White , Humanos , Adulto , Criança , Feminino , Adolescente , Adulto Jovem , Pessoa de Meia-Idade , Masculino , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirurgia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Ablação por Cateter/métodos , Feixe Acessório Atrioventricular/diagnóstico , Feixe Acessório Atrioventricular/cirurgia , Eletrocardiografia/métodos , Algoritmos
6.
Pacing Clin Electrophysiol ; 46(2): 161-168, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36588339

RESUMO

BACKGROUND: Catheter ablation is an effective treatment for atrial fibrillation (AF,) but arrhythmia recurrence occurs in a relevant number of patients. Mechanisms of late occurring arrhythmias after ablation procedures are not fully understood. We analyzed electrophysiological mechanisms of early and late arrhythmia recurrences in patients who underwent radiofrequency-based catheter ablation of AF. METHODS AND RESULTS: Consecutive patients who underwent repeat ablation procedures after initial pulmonary vein isolation (PVI) for symptomatic arrhythmia recurrence were analyzed. A total of 110 consecutive patients who underwent catheter ablation for paroxysmal (79%) or persistent AF (21%) were included. Forty-seven patients suffered from early arrhythmia recurrence (group #1: 3-24 months), 29 patients from mid-term arrhythmia recurrences (group #2: 2-5 years), and 34 patients from late arrhythmia recurrences (group #3: > 5 years). Electrical PV reconnection was found in 98% in group #1, 72% in group #2 and 56% in group #3 (p < .001). Mode of arrhythmia recurrence was organized tachycardia in 25%, 28%, and 65% of patients in groups #1, #2, and #3 (p = .001), respectively. Patients with late arrhythmia recurrence had more pronounced left atrial low voltage as compared to patients with early arrhythmia recurrence based on two published scoring system. CONCLUSION: Electrical PV reconnection was found in the majority of patients with early AF recurrence after PVI. In patients with late arrhythmia recurrences this mechanism may play an inferior role, with many patients presenting without PV reconnection, but with LA structural alterations. Thus, early and late occurring arrhythmia recurrence after catheter ablation may be the same symptom of different diseases.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Recidiva , Átrios do Coração , Resultado do Tratamento , Ablação por Cateter/métodos
7.
Herz ; 48(3): 212-217, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37277617

RESUMO

Arrhythmic manifestations of COVID-19 include atrial arrhythmias such as atrial fibrillation or atrial flutter, sinus node dysfunction, atrioventricular conduction abnormalities, ventricular tachyarrhythmias, sudden cardiac arrest, and cardiovascular dysautonomias including the so-called long COVID syndrome. Various pathophysiological mechanisms have been implicated, such as direct viral invasion, hypoxemia, local and systemic inflammation, changes in ion channel physiology, immune activation, and autonomic dysregulation. The development of atrial or ventricular arrhythmias in hospitalized COVID-19 patients has been shown to portend a higher risk of in-hospital death. Management of these arrhythmias should be based on published evidence-based guidelines, with special consideration of the acuity of COVID-19 infection, concomitant use of antimicrobial and anti-inflammatory drugs, and the transient nature of some rhythm disorders. In view of new SARS-CoV­2 variants that may evolve, the development and use of newer antiviral and immunomodulator drugs, and the increasing adoption of vaccination, clinicians must remain vigilant for other arrhythmic manifestations that may occur in association with this novel but potentially deadly disease.


Assuntos
Fibrilação Atrial , COVID-19 , Humanos , Incidência , Síndrome de COVID-19 Pós-Aguda , Mortalidade Hospitalar , SARS-CoV-2 , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle
8.
Herz ; 48(4): 292-300, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35397659

RESUMO

BACKGROUND: Polymer-free and carrier-free drug-coated stents (DCS) represent a novel therapeutic option for the treatment of coronary artery disease. The objective of this pilot registry is to evaluate the safety and efficacy of DCS implantation in bifurcation lesions. METHODS: Overall, 23 consecutive patients with 24 lesions received a Biolimus A9-coated DCS for coronary bifurcation lesions. Patients were examined with quantitative coronary angiography (QCA) and optical coherence tomography (OCT) at 3-6 months of follow-up. RESULTS: A total of 23 patients with 24 bifurcation lesions were included in this study. Nine (33.3%) lesions of eight patients revealed angiographical target lesion failure due to in-stent restenosis (ISR). In total, 19 patients with 20 bifurcation lesions were suitable for OCT analysis. A total of 2936 struts were analyzed and 14 struts (0.47%) were classified as malapposed. The mean luminal area (mm2) was not different in lesions with ISR vs. lesions with no ISR (5.07 ± 2.0 vs. 5.73 ± 1.34, p = 0.39) at follow-up. Lesions with ISR showed higher mean neointimal burden (27.11 ± 10.59 vs. 13.93 ± 9.16%, respectively; p = 0.009). All of the patients who presented with significant ISR required percutaneous re-intervention. CONCLUSIONS: We observed a high rate of DCS ISR in bifurcation lesions, possibly related to increased inflammation and neoatherosclerosis. The small size of the study warrants careful interpretation of our results. Larger trials are necessary to expand knowledge of these findings.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Tomografia de Coerência Óptica , Vasos Coronários , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Angiografia Coronária , Sistema de Registros , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/terapia
9.
J Cardiovasc Electrophysiol ; 33(8): 1678-1686, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35615939

RESUMO

INTRODUCTION: Focal Impulse and Rotor Modulation (FIRM) guided catheter ablation aiming at stable rotors has been investigated as a treatment option in patients with atrial fibrillation (AF). The objective of this study was to compare the safety and efficacy of FIRM-guided ablation with second-generation cryoballoon pulmonary vein isolation (CB2-PVI) in paroxysmal AF. METHODS: Consecutive patients (n = 22, mean age 60 ± 11 years, 59.1% of males) who were treated with a stand-alone FIRM-guided ablation were included in this retrospective single-center study. Procedural data and arrhythmia-free survival at 12 months were compared with n = 86 consecutive patients (mean age 62 ± 13 years, 62.4% of males) who received de-novo CB2-PVI. RESULTS: Median procedure duration was significantly longer in the FIRM group than in the CB2-PVI group (152 [IQR 120-176] minutes vs. 122 [110-145] minutes; p = .031). One patient (1.2%) in the CB2-PVI group and five patients (22.7%) in the FIRM group had vascular access complications. Atrial tachyarrhythmias recurred in 15 patients in the FIRM group and 11 in the CB2-PVI group. Kaplan-Meier estimation of single-procedure arrhythmia-free survival at 12 months was 25% (95% confidence interval [CI] 6%-44%) in the FIRM group and 87% (95% CI 78%-96%) in the CB2-PVI group (p < .001). Repeat ablations were performed in 14/20 (70.0%) patients in the FIRM group and in 12/85 (14.1%) in the CB2-PVI group (p < .001). CONCLUSION: De novo ablation of AF using FIRM-guided AF ablation results in shorter arrhythmia-free survival after 12 months compared to CB2-PVI and a need for repeat ablation in the majority of patients to achieve stable sinus rhythm.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 33(9): 2003-2012, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35761754

RESUMO

INTRODUCTION: Arrhythmia recurrence after pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) is common and often linked to pulmonary vein reconnection. In patients with arrhythmia recurrences despite durable PVI the optimal ablation approach is unclear. The purpose of the present study was to analyze efficacy of extended ablation maneuvers in these patients and predictors of procedural success. METHODS: Consecutive patients with durable PVI undergoing repeat ablation procedures were prospectively enrolled. Patients underwent substrate modification with creation of linear lesions and/or mechanism-specific atrial tachycardia (AT) ablation. Three dimensional-mapping images were analyzed for the presence of left atrial (LA) low-voltage areas according to published scoring systems. RESULTS: Seventy-four patients were analyzed. Mode of recurrence after durable PVI was AF in 27 patients (36.5%) and AT in 47 patients (63.5%). Linear lesion ablation was performed in 60 patients (81.1%). Twenty-four patients (32.4%) were treated for focal AT mechanisms. Mean follow-up was 565 ± 342 days. Estimated arrhythmia-free survival after 24 months was significantly higher in patients with AT than in patients with AF as mode of recurrence after durable PVI (42.9 ± 8.2% vs. 24.7 ± 8.5%, p = .023) and in patients without compared to patients with marked LA low-voltage areas (40.5 ± 9.2% vs. 22.8 ± 8.5%, p = .041). The mode of recurrence after durable PVI was the only independent predictor of further arrhythmia recurrence after repeat ablation. CONCLUSION: Arrhythmia-free survival following repeat ablation procedures in patients with durable PVI highly depends on mode of arrhythmia recurrence and the presence of LA low-voltage areas.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 33(6): 1096-1103, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35304790

RESUMO

BACKGROUND: Cryoballoon (CB)-based pulmonary vein isolation (PVI) has proven to be as effective as radiofrequency-based ablation. Different ablation protocols took the individual time-to-isolation (TTI) into account aiming at shorter but equally or even more effective freeze cycles. The current study sought to assess the impact of the TTI on PVI durability in patients undergoing a repeat procedure for recurrence of atrial tachyarrhythmia (ATA). METHODS AND RESULTS: In 205 patients with ATA recurrence after previous CB-based PVI, a total of 806 pulmonary veins (PVs) were identified. A total of 126 out of 806 PVs (16%) were previously treated with a TTI-guided ablation (Protocol #1; TTI + 120 s), in 92/806 (11%) PVs TTI was only monitored (m) but fixed freeze cycles were applied (Protocol #2; mTTI) and in 588/806 (73%) a fixed freeze cycle was applied without mTTI. There was no difference in the PV-reconduction rate between the groups (p = .23). The right inferior pulmonary vein (RIPV) showed overall significantly higher reconduction rates compared to the other PVs (RIPV-left inferior PV p < .003, -left superior PV p < .001, -right superior PV p < .013). Twenty-one patients (10%) were demonstrated to have only electrical reconduction of the RIPV, while all other PVs were still electrically isolated. CONCLUSIONS: The TTI-based CB ablation protocol did not show significant differences regarding PV-reconduction rates compared to the other ablation protocols.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
12.
Europace ; 24(6): 921-927, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34907431

RESUMO

AIMS: Cryoballoon (CB) based pulmonary vein isolation (PVI) is a widely used technique for treatment of atrial fibrillation (AF); however the ideal energy dosing has not yet been standardized. This was a single-centre randomized clinical trial aiming at assessing the safety, acute efficacy, and clinical outcome of an individualized vs. a fixed CB ablation protocol using the fourth-generation CB (CB4) guided by pulmonary vein (PV) potential recordings and CB temperature. METHODS AND RESULTS: Patients were randomized in a 1:1 fashion to two different dosing protocols: INDI-FREEZE group (individualized protocol): freeze-cycle duration of time to effect plus 90 s or interruption of the freeze-cycle and repositioning CB if a CB temperature of -30°C was not within 40 s. Control group (fixed protocol): freeze-cycle duration of 180 s. No-bonus freeze-cycle was applied in either patient group. The primary endpoint was freedom from atrial tachyarrhythmia at 12 months. Secondary end points included procedural parameters and complications. A total of 100 patients with paroxysmal AF were prospectively enrolled. No difference was seen in the primary endpoint [INDI-FREEZE group: 38/47 (81%) vs. control group: 40/47, (85%), P = 0.583]. The total freezing time was significantly shorter in the INDI-FREEZE group (157 ± 56 s vs. 212 ± 83 s, P < 0.001), while procedure duration (57.9 ± 17.9 min vs. 63.2 ± 20.2 min, P = 0.172) was similar. No differences were seen in the minimum CB and oesophageal temperatures as well as in periprocedural complications. CONCLUSION: Compared to the fixed protocol, the individualized approach provides a similar safety profile and clinical outcome, while reducing the total freezing time.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Congelamento , Humanos , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
13.
Pacing Clin Electrophysiol ; 45(9): 1024-1031, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35822917

RESUMO

BACKGROUND: Perimitral flutter and atrial fibrillation may occur in patients with prior surgical mitral valve (MV) repair or replacement and can be challenging for percutaneous catheter ablation. This study sought to determine the feasibility, acute success and durability of catheter ablation of atrial fibrillation or atrial tachycardia by way of a mitral isthmus line (MIL) or an anterior line (AL). METHODS: A total of 81 patients (49 males, mean age 62±11 years) with prior MV replacement (n = 30) or reconstruction (n = 51) underwent creation of a MIL (34) and/or an AL (72). RESULTS: Acute bidirectional block of the MIL was successfully achieved in 24/34 cases and of the AL in 64/72 patients. Patients of the control group without prior MV surgery were matched 1:1 with the valve group. In the AL control subgroup, acute bidirectional block was achieved in 65/72 patients. Acute blockage in the MIL control subgroup could be achieved in 31/34 patients. The MIL valve subgroup showed the worst results in terms of durability, whereas a similar trend emerged in the control group and the AL valve subgroup (probability of failure in MIL valve subgroup 2.224 vs. MIL control subgroup 0.605 [Hazard Ratio (HR) = 0.27, 95% confidence interval (CI), 0.11-0.65), P = .004]; probability of failure in AL valve subgroup 0.844 vs. AL control subgroup 1.03 [HR = 1.22 (95% CI, 0.66-2.26), P = .523]). CONCLUSIONS: Percutaneous creation of MIL and AL is feasible and safe in patients with prior MV replacement/repair and associated with moderate acute and long-term success rates to achieve bidirectional block.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Idoso , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Resultado do Tratamento
14.
Circulation ; 141(13): 1057-1067, 2020 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-32000514

RESUMO

BACKGROUND: Catheter ablation for ventricular tachycardia (VT) reduces the recurrence of VT in patients with implantable cardioverter-defibrillators (ICDs). The appropriate timing of VT ablation and its effects on mortality and heart failure progression remain a matter of debate. In patients with life-threatening arrhythmias necessitating ICD implantation, we compared outcomes of preventive VT ablation (undertaken before ICD implantation to prevent ICD shocks for VT) and deferred ablation after 3 ICD shocks for VT. METHODS: The BERLIN VT study (Preventive Ablation of Ventricular Tachycardia in Patients With Myocardial Infarction) was a prospective, open, parallel, randomized trial performed at 26 centers. Patients with stable ischemic cardiomyopathy, a left ventricular ejection fraction between 30% and 50%, and documented VT were randomly assigned 1:1 to a preventive or deferred ablation strategy. The primary outcome was a composite of all-cause death and unplanned hospitalization for either symptomatic ventricular arrhythmia or worsening heart failure. Secondary outcomes included sustained ventricular tachyarrhythmia and appropriate ICD therapy. We hypothesized that preventive ablation strategy would be superior to deferred ablation strategy in the intention-to-treat population. RESULTS: During a mean follow-up of 396±284 days, the primary end point occurred in 25 (32.9%) of 76 patients in the preventive ablation group and 23 (27.7%) of 83 patients in the deferred ablation group (hazard ratio, 1.09 [95% CI, 0.62-1.92]; P=0.77). On the basis of prespecified criteria for interim analyses, the study was terminated early for futility. In the preventive versus deferred ablation group, 6 versus 2 patients died (7.9% versus 2.4%; P=0.18), 8 versus 2 patients were admitted for worsening heart failure (10.4% versus 2.3%; P=0.062), and 15 versus 21 patients were hospitalized for symptomatic ventricular arrhythmia (19.5% versus 25.3%; P=0.27). Among secondary outcomes, the proportions of patients with sustained ventricular tachyarrhythmia (39.7% versus 48.2%; P=0.050) and appropriate ICD therapy (34.2% versus 47.0%; P=0.020) were numerically reduced in the preventive ablation group. CONCLUSIONS: Preventive VT ablation before ICD implantation did not reduce mortality or hospitalization for arrhythmia or worsening heart failure during 1 year of follow-up compared with the deferred ablation strategy. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02501005.


Assuntos
Cardiomiopatias/complicações , Ablação por Cateter/métodos , Desfibriladores Implantáveis/normas , Taquicardia Ventricular/terapia , Idoso , Cardiomiopatias/cirurgia , Feminino , Humanos , Masculino , Estudos Prospectivos
15.
J Cardiovasc Electrophysiol ; 32(6): 1553-1560, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33760304

RESUMO

BACKGROUND: The second-generation cryoballoon (CB2) provides effective and durable pulmonary vein isolation (PVI) associated with encouraging clinical outcome. The novel fourth-generation cryoballoon (CB4) incorporates a 40% shorter distal tip. This design change may translate into an increased rate of PVI real-time signal recording, facilitating an individualized ablation strategy using the time to effect (TTE). METHODS AND RESULTS: Three hundred consecutive patients with paroxysmal or persistent atrial fibrillation were prospectively enrolled. The first 150 consecutive patients underwent CB2 based PVI (CB2 group) and the last 150 consecutive patients were treated with the CB4 (CB4 group). A total of 594/594 (100%, CB4) and 589/594 (99.2%, CB2) pulmonary veins (PVs) were successfully isolated utilizing the CB4 and CB2, respectively (p = .283). The real-time PVI visualization rate was 47% (CB4) and 39% (CB2; p = .005) and the mean freeze cycle duration 200 ± 90 s (CB4) and 228 ± 110 s (CB2; p < .001), respectively. The total procedure time did not differ between the groups (CB4: 64 ± 32 min) and (CB2: 62 ± 29 min, p = .370). No differences in periprocedural complications were detected. CONCLUSIONS: A higher rate of real-time electrical PV recordings are seen using the CB4 as compared to CB2, which may facilitate an individualized ablation strategy using the TTE.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
16.
Int Heart J ; 62(1): 65-71, 2021 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-33455982

RESUMO

Left atrial (LA) fibrosis is associated with a poor outcome after atrial fibrillation (AF) ablation. This study examined the extent of low-voltage areas in patients with recurrence of atrial tachyarrhythmia (ATA) after CB-based pulmonary vein isolation (PVI).Sixty patients (mean age 67 ± 10 years, n = 32 female; n = 34 paroxysmal AF) who received radiofrequency redo-procedure due to recurrence of ATA within 6 months after CB-based PVI were included. A point-by point 3D-map was performed, and low-voltage sites were delineated based on bipolar voltage < 0.5 mV. The extent of fibrosis was categorized as stage A (0-10% of the LA wall), stage B (10-30%), stage C (30-50%), and stage D (> 50%).The median area of LA low-voltage sites was 28.9 (9; 50.3) cm2, corresponding to 17.4 (6; 30.6) % of the LA wall surface. 17/60 (28.3%) patients were categorized as fibrosis stage A, 21/60 (35%) as stage B, 18/60 (30%) as stage C, and 4/60 (6.7%) as stage D. Patient age and LA diameter were associated with more pronounced LA fibrosis; the extent of LA fibrosis was significantly higher in patients with LA tachycardia (LAT) during redo-procedures (P < 0.01), and ablation of linear lesions was more often performed (P < 0.01).In patients after CB2-based PVI, expanded LA tissue fibrosis was associated with the occurrence of LAT and more extensive LA ablation during redo-procedures.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Fibrose/complicações , Átrios do Coração/patologia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Feminino , Fibrose/classificação , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Taquicardia Supraventricular/epidemiologia , Taquicardia Supraventricular/etiologia , Resultado do Tratamento
17.
Europace ; 22(9): 1358-1366, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32743641

RESUMO

AIMS: Left atrial appendage (LAA) electrical isolation (LAAEI) in addition to pulmonary vein isolation is an emerging catheter-based therapy to treat symptomatic atrial fibrillation. Previous studies found high incidences of LAA thrombus formation after LAAEI. This study sought to analyse therapeutic strategies aiming at the resolution of LAA thrombi and prevention of thromboembolism. METHODS AND RESULTS: Left atrial appendage electrical isolation was conducted via creation of left atrial linear lesions or cryoballoon ablation. Follow-up including transoesophageal echocardiography was conducted. In patients with LAA thrombus, oral anticoagulation (OAC) was adjusted until thrombus resolution was documented. Percutaneous LAA closure (LAAC) under use of a cerebral protection device was conducted in case of medically refractory LAA thrombi. Left atrial appendage thrombus was documented in 54 of 239 analysed patients who had undergone LAAEI. Thrombus resolution was documented in 39/51 patients (72.2%) with available follow-up after adjustment of OAC. Twenty-nine patients underwent LAAC and 10 patients were kept on OAC after LAAEI. No thromboembolic events or further LAA thrombi were documented after 553 ± 443 days of follow-up in these patients. Persistent LAA thrombi despite adaption of OAC was documented in 12/51 patients. One patient remained on OAC until the end of follow-up, while LAAC with a cerebral protection device was performed in 11 patients in the presence of LAA thrombus without complications. CONCLUSION: Left atrial appendage thrombus formation is common after LAAEI. Adjustment of OAC leads to LAA thrombus resolution in most patients. Left atrial appendage closure in the presence of LAA thrombi might be a feasible option in case of failed medical treatment.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Tromboembolia , Trombose , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Humanos , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Trombose/diagnóstico por imagem , Trombose/prevenção & controle , Resultado do Tratamento
18.
Europace ; 22(8): 1240-1251, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32500141

RESUMO

AIMS: The aim of this study was to analyse tamponades following electrophysiological procedures regarding frequency and mortality in a high-volume centre and to identify independent predictors for severe tamponades. METHODS AND RESULTS: We performed a retrospective study on 34 982 consecutive patients undergoing diagnostic electrophysiological studies or catheter ablation of cardiac arrhythmias. The combined endpoint was defined as severe tamponade. Criteria for severe tamponade included surgical repair, repeat pericardiocentesis, cardiopulmonary resuscitation, intrahospital death or death during follow-up, and thrombo-embolic events or complications due to therapeutic management. Multivariate analysis was performed to identify independent predictors for severe tamponade. A total of 226 tamponades were identified. Overall frequency of tamponades was 0.6%. Procedures requiring epicardial approach had the highest rate of tamponades (9.4%). Twenty-nine patients with tamponade underwent surgery (12.8% of all tamponades and 21.4% of tamponades during epicardial procedures). Overall tamponade-related mortality was 0.03% (9 deaths). Fifty-six patients (24.8%) experienced severe tamponade. Independent risk factors for severe tamponades were endocardial ablation of ventricular tachycardia, epicardial approach, balloon device ablation, high aspiration volume during pericardiocentesis and structural heart disease. CONCLUSION: The frequency of tamponades is strongly dependent on the type of procedure performed. Overall tamponade-related mortality was low but significantly higher in patients undergoing epicardial procedures. Surgical backup should be considered for patients undergoing complex ventricular tachycardia ablation and left atrial ablation procedures.


Assuntos
Tamponamento Cardíaco , Ablação por Cateter , Eletrofisiologia Cardíaca , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Pericardiocentese/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
19.
Circ J ; 84(6): 902-910, 2020 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-32307357

RESUMO

BACKGROUND: The second-generation cryoballoon (CB2) has demonstrated high procedural efficacy and convincing clinical success rates for pulmonary vein isolation (PVI). Nevertheless, data on the impact of different ablations protocols on durability are limited. The aim was to comparing the durability of PVI following 3 different ablation strategies in patients with recurrence of atrial fibrillation or atrial tachycardia undergoing repeat procedures.Methods and Results:In 192 patients, a total of 751 PVs were identified. All PVs were successfully isolated during index PVI. Thirty-one out of 192 (16%) patients were treated with a bonus-freeze protocol (group 1), 67/192 (35%) patients with a no bonus-freeze protocol (group 2), and 94/192 (49%) patients with a time-to-effect-guided protocol (group 3). Persistent PVI was documented in 419/751 (55.8%) PVs, and in 41/192 (21%) patients, all PVs were persistently isolated. The total rate of PV reconnection was not significantly different between the groups (P=0.134) and the comparison of individual PVs revealed no differences (P-values for RSPV: 0.424, RIPV: 0.541, LSPV: 0.788, LIPV: 0.346, LCPV: 0.865). The procedure times were significantly reduced by omitting the bonus-freeze and applying individualized application times (group 1: 123.4±31.5 min, group 2: 112.9±39.8 min, group 3: 86.67±28.4 min, P<0.001). CONCLUSIONS: Comparing 3 common ablation protocols, no differences for durable PVI were detected. Procedure times were significantly reduced by omitting the bonus-freeze cycle and by applying individualized application times.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Frequência Cardíaca , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
20.
Pacing Clin Electrophysiol ; 43(10): 1115-1125, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32794580

RESUMO

BACKGROUND: Catheter ablation of atrial fibrillation (AF) in patients with pulmonary lobectomy or pneumectomy is challenging due to anatomical alterations. After lung resection, electrically active pulmonary vein (PV) stumps remain and need to be localized for PV isolation (PVI). The present study aims to describe clinical challenges of PVI in patients with pulmonary lobectomy or pneumectomy. METHODS: We performed a retrospective study on 19 patients with previous pulmonary lobectomy or pneumectomy undergoing catheter ablation for AF in three German hospitals. RESULTS: Nineteen patients with paroxysmal, persistent, or longstanding-persistent AF and history of pulmonary lobectomy (n = 11) or pneumectomy (n = 8) were enrolled. Catheter ablation was performed as radiofrequency (RF) ablation using 3D mapping, robotic RF ablation, or by using balloon devices. Decent anatomical changes were observed in patients with lobectomy while cardiac rotation and mediastinal shifting was dominant in patients with pneumectomy. Visualization of all PVs including PV stumps by PV angiography was possible in 10 of 19 patients (52.6%). PV spikes were observed in all identified PV remnants. In nine patients (47.4%), at least one PV remnant could not be identified and electrical isolation was not performed. During 24 months follow-up, patients with incomplete PVI had a significantly shorter arrhythmia-free survival than patients with complete PVI (76.2% [95% Confidence interval (CI) 47.2-100.0%] vs 40.0% [95% CI 5.6-74.1%], P = .043). CONCLUSION: In patients with AF and previous lobectomy or pneumectomy, identification and isolation of all PVs are challenging but crucial for ablation success. Additional imaging techniques may be necessary to achieve complete PVI.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Pneumonectomia , Veias Pulmonares/cirurgia , Idoso , Anticoagulantes/administração & dosagem , Fibrilação Atrial/diagnóstico por imagem , Ablação por Cateter/instrumentação , Ecocardiografia Transesofagiana , Mapeamento Epicárdico , Feminino , Alemanha , Humanos , Masculino , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA