Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 182
Filtrar
1.
Int J Cancer ; 155(11): 2047-2057, 2024 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-39023303

RESUMO

The purpose of this study was to determine if dual-energy CT (DECT) vital iodine tumor burden (ViTB), a direct assessment of tumor vascularity, allows reliable response assessment in patients with GIST compared to established CT criteria such as RECIST1.1 and modified Choi (mChoi). From 03/2014 to 12/2019, 138 patients (64 years [32-94 years]) with biopsy proven GIST were entered in this prospective, multi-center trial. All patients were treated with tyrosine kinase inhibitors (TKI) and underwent pre-treatment and follow-up DECT examinations for a minimum of 24 months. Response assessment was performed according to RECIST1.1, mChoi, vascular tumor burden (VTB) and DECT ViTB. A change in therapy management could be because of imaging (RECIST1.1 or mChoi) and/or clinical progression. The DECT ViTB criteria had the highest discrimination ability for progression-free survival (PFS) of all criteria in both first line and second line and thereafter treatment, and was significantly superior to RECIST1.1 and mChoi (p < .034). Both, the mChoi and DECT ViTB criteria demonstrated a significantly early median time-to-progression (both delta 2.5 months; both p < .036). Multivariable analysis revealed 6 variables associated with shorter overall survival: secondary mutation (HR = 4.62), polymetastatic disease (HR = 3.02), metastatic second line and thereafter treatment (HR = 2.33), shorter PFS determined by the DECT ViTB criteria (HR = 1.72), multiple organ metastases (HR = 1.51) and lower age (HR = 1.04). DECT ViTB is a reliable response criteria and provides additional value for assessing TKI treatment in GIST patients. A significant superior response discrimination ability for median PFS was observed, including non-responders at first follow-up and patients developing resistance while on therapy.


Assuntos
Tumores do Estroma Gastrointestinal , Inibidores de Proteínas Quinases , Humanos , Tumores do Estroma Gastrointestinal/tratamento farmacológico , Tumores do Estroma Gastrointestinal/patologia , Tumores do Estroma Gastrointestinal/mortalidade , Pessoa de Meia-Idade , Masculino , Feminino , Idoso , Inibidores de Proteínas Quinases/uso terapêutico , Estudos Prospectivos , Adulto , Idoso de 80 Anos ou mais , Neoplasias Gastrointestinais/tratamento farmacológico , Neoplasias Gastrointestinais/patologia , Tomografia Computadorizada por Raios X/métodos , Critérios de Avaliação de Resposta em Tumores Sólidos , Carga Tumoral/efeitos dos fármacos , Intervalo Livre de Progressão , Resultado do Tratamento
2.
Urol Int ; : 1-8, 2024 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-39217986

RESUMO

INTRODUCTION: Multiparametric MRI (mpMRI) is gold standard for the primary diagnostic work-up of clinically significant prostate cancer (csPCa). The aim of this study was to assess the benefit of the perfusion sequence and the non-inferiority of an MRI without contrast administration (bpMRI) compared to mpMRI while taking clinical parameters into account. METHODS: In this retrospective, non-interventional study we examined MRI data from 355 biopsy-naïve patients, performed on a 3T MRI system, evaluated by a board-certified radiologist with over 10 years of experience with subsequent mpMRI-TRUS fusion biopsy. DISCUSSION: Only 16/355 (4.5%) patients benefited from dynamic contrast enhanced. In only 3/355 (0.8%) patients, csPCa would have been missed in bpMRI. BpMRI provided sensitivity and specificity (81.4%; 79.4%) comparable to mpMRI (75.2%; 81.8%). Additionally, bpMRI and mpMRI were independent predictors for the presence of csPCa, individually (OR: 15.36; p < 0.001 vs. 12.15; p = 0.006) and after accounting for established influencing factors (OR: 12.81; p < 0.001 vs. 6.50; p = 0.012). When clinical parameters were considered, a more balanced diagnostic performance between sensitivity and specificity was found for mpMRI and bpMRI. Overall, PSA density showed the highest diagnostic performance (area under the curve = 0.81) for the detection of csPCa. CONCLUSION: The premise of the study was confirmed. Therefore, bpMRI should be adopted as soon as existing limitations have been lifted by prospective multi-reader studies.

3.
AJR Am J Roentgenol ; 218(4): 659-669, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34668385

RESUMO

BACKGROUND. CT-based criteria for assessing the gastrointestinal stromal tumor (GIST) response to tyrosine kinase inhibitor (TKI) therapy are limited in part because tumor attenuation is influenced by treatment-related changes including hemorrhage and calcification. The iodine concentration may be less impacted by such changes. OBJECTIVE. The purpose of this study was to determine whether the dual-energy CT (DECT) vital iodine tumor burden (TB) allows improved differentiation between treatment responders and nonresponders among patients with metastatic GIST who are undergoing TKI therapy compared with established CT and PET/CT criteria. METHODS. An anthropomorphic phantom with spherical inserts mimicking GIST lesions of varying iodine concentrations and having nonenhancing central necrotic cores underwent DECT to determine a threshold iodine concentration. Forty patients (25 women and 15 men; median age, 57 years) who were treated with TKI for metastatic GIST were retrospectively evaluated. Patients underwent baseline and follow-up DECT and FDG PET/CT. Response assessment was performed using RECIST 1.1, modified Choi (mChoi) criteria, vascular tumor burden (VTB) criteria, DECT vital iodine TB criteria, and European Organization for Research and Treatment of Cancer (EORTC) PET criteria. DECT vital iodine TB criteria used the same percentage changes as RECIST 1.1 response categories. Progression-free survival was compared between responders and nonresponders for each response criterion by use of Cox proportional hazard ratios and Harrell C-indexes (i.e., concordance indexes). RESULTS. The phantom experiment identified a threshold of 0.5 mg/mL to differentiate vital from nonvital tissue. With use of the DECT vital iodine TB, median progression-free survival was significantly different between responders and nonresponders (623 vs 104 days; p < .001).. For nonresponders versus responders, the hazard ratio for disease progression for DECT vital iodine TB was 6.9 versus 7.6 for EORTC PET criteria, 3.3 for VTB criteria, 2.3 for RECIST 1.1, and 2.1 for mChoi criteria. The C-index was 0.74 for EORTC PET criteria, 0.73 for DECT vital iodine TB criteria, 0.67 for VTB criteria, 0.61 for RECIST 1.1, and 0.58 for mChoi criteria. The C-index was significantly greater for DECT vital iodine TB criteria than for RECIST 1.1 (p = .02) and mChoi criteria (p = .002), but it was not different from that for VTB and EORTC PET criteria (p > .05). CONCLUSION. DECT vital iodine TB criteria showed performance comparable to that of EORTC PET criteria and outperformed RECIST 1.1 and mChoi criteria for response assessment of metastatic GIST treated with TKI therapy. CLINICAL IMPACT. DECT vital iodine TB could help guide early management decisions in patients receiving TKI therapy.


Assuntos
Tumores do Estroma Gastrointestinal , Iodo , Segunda Neoplasia Primária , Feminino , Fluordesoxiglucose F18 , Tumores do Estroma Gastrointestinal/diagnóstico por imagem , Tumores do Estroma Gastrointestinal/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Carga Tumoral
4.
Radiology ; 291(2): 381-390, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30860450

RESUMO

Background Dual-energy (DE) CT allows reconstruction of virtual noncontrast (VNC) images from a single-phase contrast agent-enhanced examination, potentially reducing the need for multiphasic CT to characterize renal lesions. However, data regarding diagnostic performance of VNC images for the characterization of renal lesions are limited. Purpose To determine whether renal mass CT performed by using VNC images allows for reliable identification of renal lesions and differentiation of contrast-enhanced from unenhanced lesions, compared with unenhanced images. Materials and Methods This is a retrospective study of 293 patients (105 women [mean age, 65 years; age range, 18-91 years] and 188 men [mean age, 66 years; age range, 23-90 years] with 379 renal lesions [craniocaudal diameter, 1.0-4.0 cm]) who underwent a single-energy unenhanced CT examination followed by a nephrographic-phase DE CT between June 2013 and October 2017 by using one of four different DE CT platforms from two vendors. VNC images were calculated by using vendor-specific algorithms. Each lesion was classified in a blinded and independent fashion by using the VNC or unenhanced image in combination with the nephrographic images. Attenuation measurements were obtained on the VNC, unenhanced, and nephrographic images. Unenhanced images and pathologic or imaging follow-up for more than 24 months served as reference standard. Results There was strong overall agreement between VNC and unenhanced images for renal lesion characterization (Cramer V = 0.85). VNC images yielded a high diagnostic performance (area under the receiver operating characteristic curve, 0.91; 95% confidence interval: 0.86, 0.95) for facilitation of differentiation of contrast-enhanced from unenhanced renal lesions. However, there was a reduction in diagnostic performance for depicting contrast-enhanced renal lesions by using VNC compared with unenhanced images (area under the receiver operating characteristic curve, 0.91 [95% confidence interval: 0.86, 0.95] vs 0.96 [95% confidence interval: 0.93, 0.99]; P < .001). Mean absolute difference between the VNC and unenhanced attenuation was 9.2 HU ± 8.7. Conclusion Virtual noncontrast images enabled accurate renal lesion characterization, albeit with a reduction in diagnostic performance for contrast-enhanced lesion characterization. © RSNA, 2019 Online supplemental material is available for this article.


Assuntos
Neoplasias Renais/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hematúria/diagnóstico por imagem , Humanos , Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Adulto Jovem
5.
Blood ; 129(4): 415-419, 2017 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-27903529

RESUMO

Microvascular endothelial cells (ECs) display a high degree of phenotypic and functional heterogeneity among different organs. Organ-specific ECs control their tissue microenvironment by angiocrine factors in health and disease. Liver sinusoidal endothelial cells (LSECs) are uniquely differentiated to fulfill important organ-specific functions in development, under homeostatic conditions, and in regeneration and liver pathology. Recently, Bmp2 has been identified by us as an organ-specific angiokine derived from LSECs. To study angiocrine Bmp2 signaling in the liver, we conditionally deleted Bmp2 in LSECs using EC subtype-specific Stab2-Cre mice. Genetic inactivation of hepatic angiocrine Bmp2 signaling in Stab2-Cre;Bmp2fl/fl (Bmp2LSECKO) mice caused massive iron overload in the liver and increased serum iron levels and iron deposition in several organs similar to classic hereditary hemochromatosis. Iron overload was mediated by decreased hepatic expression of hepcidin, a key regulator of iron homeostasis. Thus, angiocrine Bmp2 signaling within the hepatic vascular niche represents a constitutive pathway indispensable for iron homeostasis in vivo that is nonredundant with Bmp6. Notably, we demonstrate that organ-specific angiocrine signaling is essential not only for the homeostasis of the respective organ but also for the homeostasis of the whole organism.


Assuntos
Proteína Morfogenética Óssea 2/genética , Células Endoteliais/metabolismo , Hemocromatose/genética , Hepcidinas/genética , Homeostase/genética , Ferro/metabolismo , Fígado/metabolismo , Animais , Proteína Morfogenética Óssea 2/deficiência , Proteína Morfogenética Óssea 6/genética , Proteína Morfogenética Óssea 6/metabolismo , Capilares/metabolismo , Capilares/patologia , Moléculas de Adesão Celular Neuronais/genética , Moléculas de Adesão Celular Neuronais/metabolismo , Células Endoteliais/patologia , Feminino , Regulação da Expressão Gênica , Hemocromatose/metabolismo , Hemocromatose/patologia , Hepatócitos/metabolismo , Hepatócitos/patologia , Hepcidinas/metabolismo , Integrases/genética , Integrases/metabolismo , Fígado/irrigação sanguínea , Fígado/patologia , Masculino , Camundongos , Camundongos Transgênicos , Comunicação Parácrina , Transdução de Sinais , Transcrição Gênica
6.
Lancet Oncol ; 18(12): e754-e766, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29208441

RESUMO

Lung cancer screening with low-dose CT can save lives. This European Union (EU) position statement presents the available evidence and the major issues that need to be addressed to ensure the successful implementation of low-dose CT lung cancer screening in Europe. This statement identified specific actions required by the European lung cancer screening community to adopt before the implementation of low-dose CT lung cancer screening. This position statement recommends the following actions: a risk stratification approach should be used for future lung cancer low-dose CT programmes; that individuals who enter screening programmes should be provided with information on the benefits and harms of screening, and smoking cessation should be offered to all current smokers; that management of detected solid nodules should use semi-automatically measured volume and volume-doubling time; that national quality assurance boards should be set up to oversee technical standards; that a lung nodule management pathway should be established and incorporated into clinical practice with a tailored screening approach; that non-calcified baseline lung nodules greater than 300 mm3, and new lung nodules greater than 200 mm3, should be managed in multidisciplinary teams according to this EU position statement recommendations to ensure that patients receive the most appropriate treatment; and planning for implementation of low-dose CT screening should start throughout Europe as soon as possible. European countries need to set a timeline for implementing lung cancer screening.


Assuntos
Detecção Precoce de Câncer/normas , Neoplasias Pulmonares/diagnóstico , Programas de Rastreamento/normas , Guias de Prática Clínica como Assunto , Tomografia Computadorizada por Raios X/métodos , Europa (Continente) , Feminino , Humanos , Incidência , Neoplasias Pulmonares/epidemiologia , Masculino
7.
Radiology ; 282(1): 74-83, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27399326

RESUMO

Purpose To prospectively evaluate the accuracy of left ventricle (LV) analysis with a two-dimensional real-time cine true fast imaging with steady-state precession (trueFISP) magnetic resonance (MR) imaging sequence featuring sparse data sampling with iterative reconstruction (SSIR) performed with and without breath-hold (BH) commands at 3.0 T. Materials and Methods Ten control subjects (mean age, 35 years; range, 25-56 years) and 60 patients scheduled to undergo a routine cardiac examination that included LV analysis (mean age, 58 years; range, 20-86 years) underwent a fully sampled segmented multiple BH cine sequence (standard of reference) and a prototype undersampled SSIR sequence performed during a single BH and during free breathing (non-BH imaging). Quantitative analysis of LV function and mass was performed. Linear regression, Bland-Altman analysis, and paired t testing were performed. Results Similar to the results in control subjects, analysis of the 60 patients showed excellent correlation with the standard of reference for single-BH SSIR (r = 0.93-0.99) and non-BH SSIR (r = 0.92-0.98) for LV ejection fraction (EF), volume, and mass (P < .0001 for all). Irrespective of breath holding, LV end-diastolic mass was overestimated with SSIR (standard of reference: 163.9 g ± 58.9, single-BH SSIR: 178.5 g ± 62.0 [P < .0001], non-BH SSIR: 175.3 g ± 63.7 [P < .0001]); the other parameters were not significantly different (EF: 49.3% ± 11.9 with standard of reference, 48.8% ± 11.8 with single-BH SSIR, 48.8% ± 11 with non-BH SSIR; P = .03 and P = .12, respectively). Bland-Altman analysis showed similar measurement errors for single-BH SSIR and non-BH SSIR when compared with standard of reference measurements for EF, volume, and mass. Conclusion Assessment of LV function with SSIR at 3.0 T is noninferior to the standard of reference irrespective of BH commands. LV mass, however, is overestimated with SSIR. © RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Suspensão da Respiração , Técnicas de Imagem de Sincronização Cardíaca , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Disfunção Ventricular Esquerda/fisiopatologia
8.
Eur Radiol ; 27(5): 2047-2054, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27572809

RESUMO

OBJECTIVES: To evaluate detectability and quantification of coronary calcifications for CT with a tin filter for spectral shaping. METHODS: Phantom inserts with 100 small and 9 large calcifications, and a moving artificial artery with 3 calcifications (speed 0-30 mm/s) were placed in a thorax phantom simulating different patient sizes. The phantom was scanned in high-pitch spiral mode at 100 kVp with tin filter (Sn100 kVp), and at a reference of 120 kVp, with electrocardiographic (ECG) gating. Detectability and quantification of calcifications were analyzed for standard (130 HU) and adapted thresholds. RESULTS: Sn100 kVp yielded lower detectability of calcifications (9 % versus 12 %, p = 0.027) and lower Agatston scores (p < 0.008), irrespective of calcification, patient size and speed. Volume scores of the moving calcifications for Sn100 kVp at speed 10-30 mm/s were lower (p < 0.001), while mass scores were similar (p = 0.131). For Sn100 kVp with adapted threshold of 117 HU, detectability (p = 1.000) and Agatston score (p > 0.206) were similar to 120 kVp. Spectral shaping resulted in median dose reduction of 62.3 % (range 59.0-73.4 %). CONCLUSIONS: Coronary calcium scanning with spectral shaping yields lower detectability of calcifications and lower Agatston scores compared to 120 kVp scanning, for which a HU threshold correction should be developed. KEY POINTS: • Sn100kVp yields lower detectability and lower Agatston scores compared to 120kVp • Adapted HU threshold for Sn100kVp provides Agatston scores comparable to 120kVp • Sn100 kVp considerably reduces dose in calcium scoring versus 120 kVp.


Assuntos
Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Estudos de Viabilidade , Humanos , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
9.
Eur Radiol ; 27(6): 2292-2297, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27686566

RESUMO

OBJECTIVES: To investigate the relationship between image quality and patient size at 100 kilovoltage (kV) compared to 120 kV ECG-gated Triple-Rule-Out CT angiography (TRO-CTA). METHODS: We retrospectively included 73 patients (age 64 ± 14 years) who underwent retrospective ECG-gated chest CTA. 40 patients were scanned with 100 kV while 33 patients with 120 kV. Body mass index (BMI), patients' chest circumference (PC) and thoracic surface area (TSA) were recorded. Quantitative image quality was assessed as vascular attenuation in the ascending aorta (AA), pulmonary trunk (PA) and left coronary artery (LCA) and the signal-to-noise ratio (SNR) in the AA. RESULTS: There was no significant difference in BMI (26.0 ± 4.6 vs. 28.0 ± 6.7 kg/m2), PC (103 ± 7 vs. 104 ± 10 cm2) and TSA (92 ± 15 vs. 91 ± 19 cm2) between 100 kV and 120 kV group. Mean vascular attenuation was significantly higher in the 100 kV compared to the 120 kV group (AA 438 vs. 354 HU, PA 460 vs. 349 HU, LCA 370 vs. 299 HU all p < 0.001). SNR was not significantly different, even after adjusting for patient size. Radiation dose was significantly lower in the 100 kV group (10.7 ± 4.1 vs. 20.7 ± 10.7 mSv; p < 0.001). CONCLUSIONS: 100 kV TRO-CTA is feasible in normal-to-overweight patients while maintaining image quality and achieving substantial dose reduction. KEY POINTS: • 100 kV protocols result in a significantly lower radiation dose. • Mean vascular attenuation is significantly higher using 100 kV. • SNR and CNR are not significantly different between 100 kV and 120 kV. • 100 kV CTA is feasible regardless of patient size while maintaining image quality.


Assuntos
Angiografia por Tomografia Computadorizada/normas , Sobrepeso/diagnóstico por imagem , Aorta/diagnóstico por imagem , Índice de Massa Corporal , Tamanho Corporal , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários/diagnóstico por imagem , Eletrocardiografia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído
10.
Eur Radiol ; 27(10): 4110-4119, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28289942

RESUMO

OBJECTIVES: To evaluate the effect of structured reports (SRs) in comparison to non-structured narrative free text (NRs) shoulder MRI reports and potential effects of both types of reporting on completeness, readability, linguistic quality and referring surgeons' satisfaction. METHODS: Thirty patients after trauma or with suspected degenerative changes of the shoulder were included in this study (2012-2015). All patients underwent shoulder MRI for further assessment and possible surgical planning. NRs were generated during clinical routine. Corresponding SRs were created using a dedicated template. All 60 reports were evaluated by two experienced orthopaedic shoulder surgeons using a questionnaire that included eight questions. RESULTS: Eighty per cent of the SRs were fully complete without any missing key features whereas only 45% of the NRs were fully complete (p < 0.001). The extraction of information was regarded to be easy in 92% of the SRs and 63% of the NRs. The overall quality of the SRs was rated better than that of the NRs (p < 0.001). CONCLUSIONS: Structured reporting of shoulder MRI improves the readability as well as the linguistic quality of radiological reports, and potentially leads to a higher satisfaction of referring physicians. KEY POINTS: • Structured MRI reports of the shoulder improve readability. • Structured reporting facilitates information extraction. • Referring physicians prefer structured reports to narrative free text reports. • Structured MRI reports of the shoulder can reduce radiologist re-consultations.


Assuntos
Relatório de Pesquisa/normas , Ombro/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Melhoria de Qualidade , Radiologia/normas , Encaminhamento e Consulta , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA