1.
Ear Hear ; 34(5): 592-600, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23598772

RESUMO

OBJECTIVES: The aim of this research is to describe the development of an adaptive Australian Sentence Test in Noise and to validate the test in terms of test-retest reliability and efficiency using data obtained from its clinical application. DESIGN: The relative intelligibility of 1264 Bamford-Kowal-Bench (BKB)-like sentences in the presence of competing four-talker babble was assessed with cochlear implant recipients. Intensity adjustments to the babble segments were made to reduce intersentence variability. Computer software was developed to administer an adaptive speech reception threshold (SRT) test using these adjusted sentence/babble pairs and test-retest SRT data from a separate group of 23 cochlear implant recipients was analyzed, comparing different SRT calculation and test stopping rules. RESULTS: The adjusted sentence/babble pairs were used in clinical studies to obtain an SRT by presenting 32 sentences. Analysis of test-retest pairs of SRT data from 23 recipients indicated that a psychometric fit SRT calculation rule provided better reliability than did the Hearing in Noise Test (HINT) calculation rule, or rules based on mean turns. This rule, using the morpheme correct scores for each sentence, gave a standard deviation for a single SRT of 0.76 dB. Further analyses revealed that the test could be shortened to 20 sentences with an increase of 0.19 dB in variability, while reducing the median test time by approximately 2 min. CONCLUSIONS: This article reports validation data for a new Australian Sentence Test In Noise. When 20 BKB-like sentences are used with a psychometric fit calculation rule, a standard deviation of approximately 1 dB is obtained in approximately 3 min 36 sec.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva/reabilitação , Percepção da Fala , Teste do Limiar de Recepção da Fala/métodos , Idoso , Idoso de 80 Anos ou mais , Austrália , Humanos , Pessoa de Meia-Idade , Ruído , Fonética , Psicoacústica , Reprodutibilidade dos Testes , Estudos Retrospectivos , Teste do Limiar de Recepção da Fala/normas
2.
J Acoust Soc Am ; 133(4): 2412-20, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23556606

RESUMO

Cochlear implant users have limited ability to understand speech in noisy conditions. Signal processing methods to address this issue that use multiple microphones typically use beamforming to perform noise reduction. However, the effectiveness of the beamformer is diminished as the number of interfering noises increases and the acoustic environment becomes more diffuse. A multi-microphone noise reduction algorithm that aims to address this issue is presented in this study. The algorithm uses spatial filtering to estimate the signal-to-noise ratio (SNR) and attenuates time-frequency elements that have poor SNR. The algorithm was evaluated by measuring intelligibility of speech embedded in 4-talker babble where the interfering talkers were spatially separated and changed location during the test. Twelve cochlear implant users took part in the evaluation, which demonstrated a significant mean improvement of 4.6 dB (standard error 0.4, P < 0.001) in speech reception threshold compared to an adaptive beamformer. The results suggest that a substantial improvement in performance can be gained for cochlear implant users in noisy environments where the noise is spatially separated from the target speech.


Assuntos
Algoritmos , Implante Coclear/instrumentação , Implantes Cocleares , Correção de Deficiência Auditiva/instrumentação , Ruído/efeitos adversos , Mascaramento Perceptivo , Pessoas com Deficiência Auditiva/reabilitação , Processamento de Sinais Assistido por Computador , Percepção da Fala , Estimulação Acústica , Idoso , Análise de Variância , Audiometria da Fala , Limiar Auditivo , Compreensão , Correção de Deficiência Auditiva/métodos , Estimulação Elétrica , Humanos , Pessoa de Meia-Idade , Pessoas com Deficiência Auditiva/psicologia , Razão Sinal-Ruído , Inteligibilidade da Fala
3.
Ear Hear ; 33(4): e13-23, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22555182

RESUMO

OBJECTIVES: This study tested a combination of algorithms designed to improve cochlear implant performance in noise. A noise reduction (NR) algorithm, based on signal to noise ratio estimation was evaluated in combination with several directional microphone algorithms available in the Cochlear CP810 sound processor. DESIGN: Fourteen adult unilateral cochlear implant users participated in the study. Evaluation was conducted using word recognition in quiet, sentence recognition in noise, and subjective feedback via questionnaire after a period of take-home use. Music appreciation was also evaluated in a controlled listening task. The sentence recognition task measured speech reception threshold for 50% morphemes correct. The interfering maskers were speech-weighted noise and competing talkers, which were spatially separated from the target speech. In addition, the locations of the noise maskers changed during the test in an effort to replicate relevant real-world listening conditions. SmartSound directionality settings Standard, Zoom, and Beam (used in the SmartSound programs Everyday, Noise, and Focus, respectively) were all evaluated with and without NR. RESULTS: Microphone directionality demonstrated a consistent benefit in sentence recognition in all noise conditions tested. The group average speech reception threshold benefit over the Standard setting was 3.7 dB for Zoom and 5.3 dB for Beam. Addition of the NR algorithm further improved sentence recognition by 1.3 dB when the noise maskers were speech-weighted noise. There was an overall group preference for the NR algorithm in noisy environments. Group mean word recognition in quiet, preference in quiet conditions, and music appreciation were all unaffected by the NR algorithm. CONCLUSIONS: Multimicrophone directionality was effective in improving speech understanding in spatially separated noisy conditions. The single-channel NR algorithm further enhanced speech intelligibility in speech-weighted noise for cochlear implant users while maintaining equivalent performance in quiet situations and when listening to music.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Perda Auditiva/cirurgia , Ruído , Processamento de Sinais Assistido por Computador , Percepção da Fala , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Audiometria da Fala , Humanos , Pessoa de Meia-Idade , Teste do Limiar de Recepção da Fala
4.
J Acoust Soc Am ; 131(1): 327-36, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22280595

RESUMO

Noise reduction in cochlear implants has achieved significant speech perception improvements through spectral subtraction and signal-to-noise ratio based noise reduction techniques. Current methods use gain functions derived through mathematical optimization or motivated by normal listening psychoacoustic experiments. Although these gain functions have been able to improve speech perception, recent studies have indicated that they are not optimal for cochlear implant noise reduction. This study systematically investigates cochlear implant recipients' speech perception and listening preference of noise reduction with a range of gain functions. Results suggest an advantageous gain function and show that gain functions currently used for noise reduction are not optimal for cochlear implant recipients. Using the cochlear implant optimised gain function, a 27% improvement over the current advanced combination encoder (ACE) stimulation strategy in speech weighted noise and a 7% improvement over current noise reduction strategies were observed in babble noise conditions. The optimized gain function was also most preferred by cochlear implant recipients. The CI specific gain function derived from this study can be easily incorporated into existing noise reduction strategies, to further improve listening performance for CI recipients in challenging environments.


Assuntos
Implantes Cocleares , Surdez/fisiopatologia , Mascaramento Perceptivo/fisiologia , Razão Sinal-Ruído , Percepção da Fala/fisiologia , Estimulação Acústica , Idoso , Análise de Variância , Limiar Auditivo/fisiologia , Surdez/reabilitação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Medida da Produção da Fala
5.
J Clin Med ; 11(10)2022 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-35629065

RESUMO

BACKGROUND: To assess the performance of cochlear implant users, speech comprehension benefits are generally measured in controlled sound room environments of the laboratory. For field-based assessment of preference, questionnaires are generally used. Since questionnaires are typically administered at the end of an experimental period, they can be inaccurate due to retrospective recall. An alternative known as ecological momentary assessment (EMA) has begun to be used for clinical research. The objective of this study was to determine the feasibility of using EMA to obtain in-the-moment responses from cochlear implant users describing their technology preference in specific acoustic listening situations. METHODS: Over a two-week period, eleven adult cochlear implant users compared two listening programs containing different sound processing technologies during everyday take-home use. Their task was to compare and vote for their preferred program. RESULTS: A total of 205 votes were collected from acoustic environments that were classified into six listening scenes. The analysis yielded different patterns of voting among the subjects. Two subjects had a consistent preference for one sound processing technology across all acoustic scenes, three subjects changed their preference based on the acoustic scene, and six subjects had no conclusive preference for either technology. CONCLUSION: Results show that EMA is suitable for quantifying real-world self-reported preference, showing inter-subject variability in different listening environments. However, there is uncertainty that patients will not provide sufficient spontaneous feedback. One improvement for future research is a participant forced prompt to improve response rates.

6.
Ear Hear ; 32(3): 382-90, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21206365

RESUMO

OBJECTIVE: The aim of this study was to investigate whether a real-time noise reduction algorithm provided speech perception benefit for Cochlear™ Nucleus® cochlear implant recipients in the laboratory. DESIGN: The noise reduction algorithm attenuated masker-dominated channels. It estimated the signal-to-noise ratio of each channel on a short-term basis from a single microphone input, using a recursive minimum statistics method. In this clinical evaluation, the algorithm was implemented in two programs (noise reduction programs 1 [NR1] and 2 [NR2]), which differed in their level of noise reduction. These programs used advanced combination encoder (ACE™) channel selection and were compared with ACE without noise reduction in 13 experienced cochlear implant subjects. An adaptive speech reception threshold (SRT) test provided the signal-to-noise ratio for 50% sentence intelligibility in three different types of noises: speech-weighted, cocktail party, and street-side city noise. RESULTS: In all three noise types, mean SRTs for both NR programs were significantly better than those for ACE. The greatest improvement occurred for speech-weighted noise; the SRT benefit over ACE was 1.77 dB for NR1 and 2.14 dB for NR2. There were no significant differences in speech perception scores between the two NR programs. Subjects reported no degradation in sound quality with the experimental programs. CONCLUSIONS: The noise reduction algorithm was successful in improving sentence perception in speech-weighted noise, as well as in more dynamic types of background noise. The algorithm is currently being trialed in a behind-the-ear processor for take-home use.


Assuntos
Algoritmos , Implantes Cocleares , Estimulação Elétrica/métodos , Perda Auditiva/terapia , Percepção da Fala , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Ruído , Mascaramento Perceptivo , Fonética , Inteligibilidade da Fala
7.
PLoS One ; 8(9): e75662, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24086605

RESUMO

Noise reduction is often essential for cochlear implant (CI) recipients to achieve acceptable speech perception in noisy environments. Most noise reduction algorithms applied to audio signals are based on time-frequency representations of the input, such as the Fourier transform. Algorithms based on other representations may also be able to provide comparable or improved speech perception and listening quality improvements. In this paper, a noise reduction algorithm for CI sound processing is proposed based on the wavelet transform. The algorithm uses a dual-tree complex discrete wavelet transform followed by shrinkage of the wavelet coefficients based on a statistical estimation of the variance of the noise. The proposed noise reduction algorithm was evaluated by comparing its performance to those of many existing wavelet-based algorithms. The speech transmission index (STI) of the proposed algorithm is significantly better than other tested algorithms for the speech-weighted noise of different levels of signal to noise ratio. The effectiveness of the proposed system was clinically evaluated with CI recipients. A significant improvement in speech perception of 1.9 dB was found on average in speech weighted noise.


Assuntos
Implantes Cocleares , Ruído/prevenção & controle , Percepção da Fala/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Humanos , Pessoa de Meia-Idade , Razão Sinal-Ruído , Fala/fisiologia
8.
Int J Audiol ; 45(11): 619-29, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17118905

RESUMO

Previous investigation of an experimental, wearable frequency-compression hearing aid revealed improvements in speech perception for a group of listeners with moderately sloping audiograms (Simpson et al, 2005). In the frequency-compression hearing aid, high frequencies (above 1600 Hz) were amplified in addition to being lowered in frequency. Lower frequencies were amplified without frequency shifting. In the present study, an identical frequency-compression scheme was evaluated in a group of seven subjects, all of whom had steeply sloping hearing losses. No significant differences in group mean scores were found between the frequency-compression device and a conventional hearing instrument for understanding speech in quiet. Testing in noise showed improvements for the frequency-compression scheme for only one of the five subjects tested. Subjectively, all but one of the subjects preferred the sound quality of the conventional hearing instruments. In conclusion, the experimental frequency-compression scheme provided only limited benefit to these listeners with steeply sloping hearing losses.


Assuntos
Audiometria de Tons Puros/métodos , Auxiliares de Audição , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/terapia , Adulto , Idoso , Limiar Auditivo/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Inquéritos e Questionários
9.
Int J Audiol ; 44(5): 281-92, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-16028791

RESUMO

The performance of an experimental frequency compression hearing device was evaluated using tests of speech understanding in quiet. The device compressed frequencies above a programmable cut-off, resulting in those parts of the input signal being shifted to lower frequencies. Below the cut-off, signals were amplified without frequency shifting. Subjects were experienced hearing aid users with moderate-to-severe sensorineural hearing loss and sloping audiograms. Their recognition of monosyllabic words was tested using the experimental device in comparison with conventional hearing aids. Of the 17 subjects, eight showed a significant score improvement (p < 0.05), whereas one subject showed a significant score decrease. Some of the improvements may have resulted from the better audibility provided in the high frequencies by the experimental device in comparison with the conventional aids. However, a subsequent study found that increasing the high-frequency gain in the conventional aids did not produce equivalent perceptual benefits.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial/reabilitação , Percepção da Fala , Estimulação Acústica , Idoso , Idoso de 80 Anos ou mais , Testes com Listas de Dissílabos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento