Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 29(Pt 3): 843-852, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35511016

RESUMO

X-ray nano-tomography with phase contrast (nanoCT) using synchrotron radiation is a powerful tool to non-destructively investigate 3D material properties at the nanoscale. In large bone lesions, such as severe bone fractures, bone cancer or other diseases, bone grafts substituting the lost bone might be necessary. Such grafts can be of biological origin or be composed of a synthetic bone substitute. The long-term functioning of artificial bone substitutes depends on many factors. Synchrotron nanoCT imaging has great potential to contribute to further the understanding of integration of implants into bone tissue by imaging the spatial interaction between bone tissue and implant, and by accessing the interface between implant material and bone tissue. With this aim, a methodology for evaluating the image quality is presented for in-line phase contrast nanoCT images of bone scaffold samples. A PMMA-embedded tricalcium phosphate scaffold was used with both a closed and an open porosity structure and bone ingrowths as a representative system of three known materials. Parameters such as spatial resolution and signal-to-noise ratio were extracted and used to explore and quantitatively compare the effects of implementation choices in the imaging setup, such as camera technology and imaging energy, on the resulting image quality. Increasing the X-ray energy from 17.5 keV to 29.6 keV leads to a notable improvement in image quality regardless of the camera technology used, with the two tested camera setups performing at a comparable level when the recorded intensity was kept constant.


Assuntos
Materiais Biocompatíveis , Tomografia Computadorizada por Raios X , Osso e Ossos/diagnóstico por imagem , Imageamento Tridimensional/métodos , Microscopia de Contraste de Fase , Síncrotrons
2.
J Mater Sci Mater Med ; 33(6): 54, 2022 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-35691951

RESUMO

Particles released from cobalt-chromium-molybdenum (CoCrMo) alloys are considered common elicitors of chronic inflammatory adverse effects. There is a lack of data demonstrating particle numbers, size distribution and elemental composition of bone marrow resident particles which would allow for implementation of clinically relevant test strategies in bone marrow models at different degrees of exposure. The aim of this study was to investigate metal particle exposure in human periprosthetic bone marrow of three types of arthroplasty implants. Periprosthetic bone marrow sections from eight patients exposed to CoCrMo particles were analyzed via spatially resolved and synchrotron-based nanoscopic X-ray fluorescence imaging. These analyses revealed lognormal particle size distribution patterns predominantly towards the nanoscale. Analyses of particle numbers and normalization to bone marrow volume and bone marrow cell number indicated particle concentrations of up to 1 × 1011 particles/ml bone marrow or 2 × 104 particles/bone marrow cell, respectively. Analyses of elemental ratios of CoCrMo particles showed that particularly the particles' Co content depends on particle size. The obtained data point towards Co release from arthroprosthetic particles in the course of dealloying and degradation processes of larger particles within periprosthetic bone marrow. This is the first study providing data based on metal particle analyses to be used for future in vitro and in vivo studies of possible toxic effects in human bone marrow following exposure to arthroprosthetic CoCrMo particles of different concentration, size, and elemental composition. Graphical abstract.


Assuntos
Cobalto , Molibdênio , Ligas , Medula Óssea , Cromo , Humanos , Metais , Síncrotrons , Vitálio
3.
Int J Mol Sci ; 22(22)2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34830451

RESUMO

Background: Magnesium (Mg) is one of the most promising materials for human use in surgery due to material characteristics such as its elastic modulus as well as its resorbable and regenerative properties. In this study, HF-coated and uncoated novel bioresorbable magnesium fixation screws for maxillofacial and dental surgical applications were investigated in vitro and in vivo to evaluate the biocompatibility of the HF coating. Methods: Mg alloy screws that had either undergone a surface treatment with hydrofluoric-acid (HF) or left untreated were investigated. In vitro investigation included XTT, BrdU and LDH in accordance with the DIN ISO 10993-5/-12. In vivo, the screws were implanted into the tibia of rabbits. After 3 and 6 weeks, degradation, local tissue reactions and bony integration were analyzed histopathologically and histomorphometrically. Additionally, SEM/EDX analysis and synchrotron phase-contrast microtomography (µCT) measurements were conducted. The in vitro analyses revealed that the Mg screws are cytocompatible, with improved results when the surface had been passivated with HF. In vivo, the HF-treated Mg screws implanted showed a reduction in gas formation, slower biodegradation and a better bony integration in comparison to the untreated Mg screws. Histopathologically, the HF-passivated screws induced a layer of macrophages as part of its biodegradation process, whereas the untreated screws caused a slight fibrous tissue reaction. SEM/EDX analysis showed that both screws formed a similar layer of calcium phosphates on their surfaces and were surrounded by bone. Furthermore, the µCT revealed the presence of a metallic core of the screws, a faster absorbing corrosion front and a slow absorbing region of corroded magnesium. Conclusions: Overall, the HF-passivated Mg fixation screws showed significantly better biocompatibility in vitro and in vivo compared to the untreated screws.


Assuntos
Regeneração Óssea/efeitos dos fármacos , Parafusos Ósseos/efeitos adversos , Regeneração Tecidual Guiada , Magnésio/farmacologia , Animais , Regeneração Óssea/genética , Linhagem Celular , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Humanos , Ácido Fluorídrico/química , Ácido Fluorídrico/farmacologia , Magnésio/efeitos adversos , Teste de Materiais , Camundongos , Procedimentos Cirúrgicos Ortognáticos/tendências , Osteoblastos/efeitos dos fármacos
4.
Anal Chem ; 92(21): 14432-14443, 2020 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-32970419

RESUMO

Degradation of the implant surface and particle release/formation as an inflammation catalyst mechanism is an emerging concept in dental medicine that may help explain the pathogenesis of peri-implantitis. The aim of the present study was a synchrotron-based characterization of micro- and nanosized implant-related particles in inflamed human tissues around titanium and ceramic dental implants that exhibited signs of peri-implantitis. Size, distribution, and chemical speciation of the exogenous micro- and nanosized particle content were evaluated using synchrotron µ-X-ray fluorescence spectroscopy (XRF), nano-XRF, and µ-X-ray absorption near-edge structure (XANES). Titanium particles, with variable speciation, were detected in all tissue sections associated with titanium implants. Ceramic particles were found in five out of eight tissue samples associated with ceramic implants. Particles ranged in size from micro- to nanoscale. The local density of both titanium and ceramic particles was calculated to be as high as ∼40 million particles/mm3. µ-XANES identified titanium in predominantly two different chemistries, including metallic and titanium dioxide (TiO2). The findings highlight the propensity for particle accumulation in the inflamed tissues around dental implants and will help in guiding toxicological studies to determine the biological significance of such exposures.


Assuntos
Cerâmica/efeitos adversos , Implantes Dentários/efeitos adversos , Microesferas , Nanopartículas , Peri-Implantite/induzido quimicamente , Peri-Implantite/metabolismo , Titânio/efeitos adversos , Cerâmica/química , Cerâmica/metabolismo , Humanos , Tamanho da Partícula , Titânio/química , Titânio/metabolismo
5.
Contact Dermatitis ; 82(2): 73-82, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31626330

RESUMO

BACKGROUND: Red tattoos are prone to allergic reactions. The identity of the allergen(s) is mostly unknown. OBJECTIVES: Chemical analysis of human skin biopsies from chronic allergic reactions in red tattoos to identify culprit pigment(s) and metals. MATERIAL AND METHODS: One hundred four dermatome biopsies were analyzed by matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-MS/MS) for identification of commonly used organic pigments. Metal concentrations were assessed by inductively coupled plasma (ICP)-MS and x-ray fluorescence (XRF). Fourteen patients had cross-reactions in other red tattoos. RESULTS: In total, the identified pigments were mainly azo Pigment Red (P.R.) 22 (35%), P.R. 210 (24%), P.R. 170 (12%), P.R. 5 (0.9%), P.R. 112 (0.9%), and Pigment Orange (P.O.) 13 (11%). P.R. 122 (0.9%) and Pigment Violet (P.V.) 23 (8%) were also common. P.R. 22, P.R. 170, and P.R. 210 also dominated in patients with cross-reactions. In 22% of the biopsies, no red pigment was detected. Element analysis indicated the presence of the sensitizers nickel and chromium. CONCLUSIONS: P.R. 22, P.R. 170, and P.R. 210 were identified as the prevailing pigments behind chronic allergic reactions in red tattoos. The epitope causing the reaction might be a pigment-degradation product. Metal contamination may derive from different sources, and its role in red tattoo allergy cannot be ascertained.


Assuntos
Corantes/efeitos adversos , Dermatite Alérgica de Contato/etiologia , Pigmentos Biológicos/efeitos adversos , Tatuagem/efeitos adversos , Adulto , Alérgenos/efeitos adversos , Feminino , Humanos , Tinta , Masculino , Espectrometria de Massas em Tandem
6.
Part Fibre Toxicol ; 16(1): 33, 2019 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-31451117

RESUMO

BACKGROUND: Allergic reactions to tattoos are amongst the most common side effects occurring with this permanent deposition of pigments into the dermal skin layer. The characterization of such pigments and their distribution has been investigated in recent decades. The health impact of tattoo equipment on the extensive number of people with inked skin has been the focus of neither research nor medical diagnostics. Although tattoo needles contain high amounts of sensitizing elements like nickel (Ni) and chromium (Cr), their influence on metal deposition in skin has never been investigated. RESULTS: Here, we report the deposition of nano- and micrometer sized tattoo needle wear particles in human skin that translocate to lymph nodes. Usually tattoo needles contain nickel (6-8%) and chromium (15-20%) both of which prompt a high rate of sensitization in the general population. As verified in pig skin, wear significantly increased upon tattooing with the suspected abrasive titanium dioxide white when compared to carbon black pigment. Additionally, scanning electron microscopy of the tattoo needle revealed a high wear after tattooing with ink containing titanium dioxide. The investigation of a skin biopsy obtained from a nickel sensitized patient with type IV allergy toward a tattoo showed both wear particles and iron pigments contaminated with nickel. CONCLUSION: Previously, the virtually inevitable nickel contamination of iron pigments was suspected to be responsible for nickel-driven tattoo allergies. The evidence from our study clearly points to an additional entry of nickel to both skin and lymph nodes originating from tattoo needle wear with an as yet to be assessed impact on tattoo allergy formation and systemic sensitization.


Assuntos
Cromo/farmacocinética , Corantes/toxicidade , Hipersensibilidade/etiologia , Linfonodos/efeitos dos fármacos , Níquel/farmacocinética , Pele/efeitos dos fármacos , Tatuagem/efeitos adversos , Animais , Corantes/farmacocinética , Humanos , Hipersensibilidade/imunologia , Hipersensibilidade/metabolismo , Técnicas In Vitro , Tinta , Linfonodos/imunologia , Linfonodos/metabolismo , Nanopartículas/metabolismo , Nanopartículas/toxicidade , Agulhas , Tamanho da Partícula , Pele/imunologia , Pele/metabolismo , Suínos , Distribuição Tecidual , Titânio/farmacocinética , Titânio/toxicidade
7.
Contact Dermatitis ; 77(6): 397-405, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28795428

RESUMO

BACKGROUND: Allergic reactions to tattoos are not uncommon. However, identification of the culprit allergen(s) remains challenging. OBJECTIVES: We present a patient with papulo-nodular infiltration of 20-year-old tattoos associated with systemic symptoms that disappeared within a week after surgical removal of metal osteosynthesis implants from his spine. We aimed to explore the causal relationship between the metal implants and the patient's clinical presentation. METHODS: Metal implants and a skin biopsy of a reactive tattoo were analysed for elemental contents by inductively coupled plasma mass spectrometry and synchrotron-based X-ray fluorescence (XRF) spectroscopy. RESULTS: Nickel (Ni) and chromium (Cr) as well as high levels of titanium (Ti) and aluminium were detected in both the skin biopsy and the implants. XRF analyses identified Cr(III), with Cr(VI) being absent. Patch testing gave negative results for Ni and Cr. However, patch tests with an extract of the implants and metallic Ti on the tattooed skin evoked flare-up of the symptoms. CONCLUSION: The patient's hypersensitivity reaction and its spontaneous remission after removal of the implants indicate that Ti, possibly along with some of the other metals detected, could have played a major role in this particular case of tattoo-related allergy.


Assuntos
Placas Ósseas/efeitos adversos , Dermatite Alérgica de Contato/etiologia , Próteses e Implantes/efeitos adversos , Tatuagem/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Testes do Emplastro , Fraturas da Coluna Vertebral/cirurgia , Vértebras Torácicas/cirurgia
8.
Anal Chem ; 88(7): 3826-35, 2016 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-26959687

RESUMO

Here, we show results on X-ray absorption near edge structure spectroscopy in both transmission and X-ray fluorescence full-field mode (FF-XANES) at the calcium K-edge on human bone tissue in healthy and diseased conditions and for different tissue maturation stages. We observe that the dominating spectral differences originating from different tissue regions, which are well pronounced in the white line and postedge structures are associated with polarization effects. These polarization effects dominate the spectral variance and must be well understood and modeled before analyzing the very subtle spectral variations related to the bone tissue variations itself. However, these modulations in the fine structure of the spectra can potentially be of high interest to quantify orientations of the apatite crystals in highly structured tissue matrices such as bone. Due to the extremely short wavelengths of X-rays, FF-XANES overcomes the limited spatial resolution of other optical and spectroscopic techniques exploiting visible light. Since the field of view in FF-XANES is rather large the acquisition times for analyzing the same region are short compared to, for example, X-ray diffraction techniques. Our results on the angular absorption dependence were verified by both site-matched polarized Raman spectroscopy, which has been shown to be sensitive to the orientation of bone building blocks and by mathematical simulations of the angular absorbance dependence. As an outlook we further demonstrate the polarization based assessment of calcium-containing crystal orientation and specification of calcium in a beta-tricalcium phosphate (ß-Ca3(PO4)2 scaffold implanted into ovine bone. Regarding the use of XANES to assess chemical properties of Ca in human bone tissue our data suggest that neither the anatomical site (tibia vs jaw) nor pathology (healthy vs necrotic jaw bone tissue) affected the averaged spectral shape of the XANES spectra.


Assuntos
Cálcio/química , Osso Cortical/química , Minerais/química , Espectroscopia por Absorção de Raios X , Fosfatos de Cálcio/química , Simulação por Computador , Fluorescência , Humanos , Análise Espectral Raman , Raios X
9.
Anal Chem ; 86(14): 6924-30, 2014 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-24905420

RESUMO

The decorated black- and red-figured Athenian vases (sixth and fifth century BC) and the plain black-glazed ware represent a milestone in our material culture due to their aesthetic and technological value; the Attic black glaze is of particular interest since it is a highly resistant potash-alumino-silicate glass, colored by magnetite nanocrystals (<200 nm). This study presents a new methodological approach for correlating the iron oxidation state in the black glaze layer with the manufacturing process by means of conventional and confocal X-ray absorption near edge spectroscopy (XANES). The enhanced surface sensitivity of confocal XANES is combined with conventional XANES resulting in higher counting rates to reliably evaluate the iron oxidation state (Fe(3+)/ΣFe) of the surface layer. A detailed description of the new evaluation procedure is presented. The three-stage firing process was retraced by correlating selected attic black-glazed (BG) specimens from different periods (Archaic, Classical, Hellenistic) with laboratory reproductions. The modern BG specimens serving as reference samples were produced by following the three-stage firing process (i.e., under oxidizing-reducing-oxidizing (ORO) conditions) at different top temperatures, using clay suspensions of different particle size produced with treatment of raw illitic clays from Attica.

10.
J Microsc ; 255(3): 158-68, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25040055

RESUMO

The architectural properties of the osteocyte cell network provide a valuable basis for understanding the mechanisms of bone remodelling, mineral homeostasis, ageing and pathologies. Recent advances in synchrotron microtomography enable unprecedented three-dimensional imaging of both the bone lacunar network and the extracellular matrix. Here, we investigate the three-dimensional morphological properties of osteocyte lacunae in human healthy and bisphosphonate-related osteonecrotic jaw bone based on synchrotron X-ray computed tomography images, with a spatial isotropic voxel size of 300 nm. Bisphosphonate-related osteonecrosis of the jaw is a relatively new disease with increasing incidence, which remains poorly understood. A step forward in elucidating this malady is to assess whether, and how, the morphology of the osteocyte lacunar network is modified in the affected jaw tissue. We evaluate thousands of cell lacunae from five specimens of which three originate from patients diagnosed with bisphosphonate-associated osteonecrosis. In this exploratory study, we report three-dimensional quantitative results on lacunar volumes (296-502 µm(3)), shape (approximated by an ellipsoidal shape with principal axes a > b > c, such that a = 2.2b and a = 4c) and spatial distribution (i.e., 50% of the mineralized matrix volume is located within 12 µm to the closest lacunar boundary) at submicron resolution on such specimens. We observe that the average lacunar volumes of the bisphosphonate-related osteonecrotic jaw specimens were within the range of volumes found in the two specimens originating from healthy donors and conclude that lacunar volumes are not the key element in the course of bisphosphonate-related osteonecrotic jaw. In three out of five specimens we observe lacunar volume sizes in segmented osteons to be significantly different compared to lacunar volumes in the adjacent tissue regions. Furthermore, we quantify the number of lacunae containing small dense objects (on average 9%). In contrast to lacunar morphology we report the lacunar density (16,000-50,000 per mm(3)) to be different in jaw bone tissue compared to what has been reported in femoral sites.


Assuntos
Osso e Ossos/citologia , Osso e Ossos/patologia , Arcada Osseodentária/citologia , Arcada Osseodentária/patologia , Osteócitos/citologia , Osteócitos/patologia , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Imageamento Tridimensional/métodos , Pessoa de Meia-Idade , Síncrotrons , Tomografia Computadorizada por Raios X/métodos , Microtomografia por Raio-X/métodos
11.
Dent Mater ; 40(6): 930-940, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38724334

RESUMO

OBJECTIVES: An increasing number of CAD/CAM (computer-aided design/computer-aided manufacturing) hybrid materials have been introduced to the dental market in recent years. In addition, CAD/CAM hybrid materials for additive manufacturing (AM) are becoming more attractive in digital dentistry. Studies on material microstructures using micro-computed tomography (µ-CT) combined with scanning electron microscopy (SEM) have only been available to a limited extent so far. METHODS: One CAD/CAM three-dimensional- (3D-) printable hybrid material (VarseoSmile Crown plus) and two CAD/CAM millable hybrid materials (Vita Enamic; Voco Grandio), as well as one direct composite material (Ceram.x duo), were included in the present study. Cylindrical samples with a diameter of 2 mm were produced from each material and investigated by means of synchrotron radiation µ-CT at a voxel size of 0.65 µm. Different samples from the same materials, obtained by cutting and polishing, were investigated by SEM. RESULTS: The 3D-printed hybrid material showed some agglomerations and a more irregular distribution of fillers, as well as a visible layered macrostructure and a few spherical pores due to the printing process. The CAD/CAM millable hybrid materials revealed a more homogenous distribution of ceramic particles. The direct composite material showed multiple air bubbles and microstructural irregularities based on manual processing. SIGNIFICANCE: The µ-CT and SEM analysis of the materials revealed different microstructures even though they belong to the same class of materials. It could be shown that µ-CT and SEM imaging are valuable tools to understand microstructure and related mechanical properties of materials.


Assuntos
Desenho Assistido por Computador , Materiais Dentários , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Microtomografia por Raio-X , Materiais Dentários/química , Resinas Compostas/química , Impressão Tridimensional , Cerâmica/química
12.
ACS Biomater Sci Eng ; 10(1): 563-574, 2024 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-38108141

RESUMO

Cobalt-chromium-molybdenum (CoCrMo) alloys are routinely used in arthroplasty. CoCrMo wear particles and ions derived from arthroplasty implants lead to macrophage-driven adverse local tissue reactions, which have been linked to an increased risk of periprosthetic joint infection after revision arthroplasty. While metal-induced cytotoxicity is well characterized in human macrophages, direct effects on their functionality have remained elusive. Synchrotron radiation X-ray microtomography and X-ray fluorescence mapping indicated that peri-implant tissues harvested during aseptic revision of different arthroplasty implants are exposed to Co and Cr in situ. Confocal laser scanning microscopy revealed that macrophage influx is predominant in patient tissue. While in vitro exposure to Cr3+ had only minor effects on monocytes/macrophage phenotype, pathologic concentrations of Co2+ significantly impaired both, monocyte/macrophage phenotype and functionality. High concentrations of Co2+ led to a shift in macrophage subsets and loss of surface markers, including CD14 and CD16. Both Co2+ and Cr3+ impaired macrophage responses to Staphylococcus aureus infection, and particularly, Co2+-exposed macrophages showed decreased phagocytic activity. These findings demonstrate the immunosuppressive effects of locally elevated metal ions on the innate immune response and support further investigations, including studies exploring whether Co2+ and Cr3+ or CoCrMo alloys per se expose the patients to a higher risk of infections post-revision arthroplasty.


Assuntos
Cobalto , Infecções Estafilocócicas , Humanos , Cobalto/toxicidade , Cromo/toxicidade , Staphylococcus aureus , Macrófagos/patologia , Íons/farmacologia , Ligas , Infecções Estafilocócicas/patologia
13.
Heliyon ; 10(8): e29719, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38681575

RESUMO

The gadolinium-based contrast agent DOTA-Gd is clinically used in combination with local anesthetics for direct magnetic resonance arthrography. It remains unclear whether gadolinium uptake into cartilage is influenced by co-administration of bupivacaine or ropivacaine and whether DOTA-Gd alters their chondrotoxicity. Gadolinium quantification of chondrogenic spheroids revealed enhanced gadolinium uptake after simultaneous exposure to local anesthetics. Analyses of the spatial gadolinium distribution using synchrotron X-ray-fluorescence scanning indicates gadolinium exposed chondrocytes. In vitro exposure to DOTA-Gd does not alter viability and proliferation of human chondrocytes and the chondrotoxic potential of the anesthetics. Reduced viability induced by ropivacaine was found to be reversible, while exposure to bupivacaine leads to irreversible cell death. Our data suggest that ropivacaine is more tolerable than bupivacaine and that DOTA-Gd exposure does not alter the cytotoxicity of both anesthetics. Enhanced gadolinium uptake into cartilage due to co-administration of anesthetics should find attention.

14.
Front Bioeng Biotechnol ; 11: 1264409, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38026873

RESUMO

In musculoskeletal surgery, the treatment of large bone defects is challenging and can require the use of bone graft substitutes to restore mechanical stability and promote host-mediated regeneration. The use of bone allografts is well-established in many bone regenerative procedures, but is associated with low rates of ingrowth due to pre-therapeutic graft processing. Cold physical plasma (CPP), a partially ionized gas that simultaneously generates reactive oxygen (O2) and nitrogen (N2) species, is suggested to be advantageous in biomedical implant processing. CPP is a promising tool in allograft processing for improving surface characteristics of bone allografts towards enhanced cellularization and osteoconduction. However, a preclinical assessment regarding the feasibility of pre-therapeutic processing of allogeneic bone grafts with CPP has not yet been performed. Thus, this pilot study aimed to analyze the bone morphology of CPP processed allografts using synchrotron radiation-based microcomputed tomography (SR-µCT) and to analyze the effects of CPP processing on human bone cell viability and function. The analyzes, including co-registration of pre- and post-treatment SR-µCT scans, revealed that the main bone morphological properties (total volume, mineralized volume, surface area, and porosity) remained unaffected by CPP treatment if compared to allografts not treated with CPP. Varying effects on cellular metabolic activity and alkaline phosphatase activity were found in response to different gas mixtures and treatment durations employed for CPP application. It was found that 3 min CPP treatment using a He + 0.1% N2 gas mixture led to the most favourable outcome regarding a significant increase in bone cell viability and alkaline phosphatase activity. This study highlights the promising potential of pre-therapeuthic bone allograft processing by CPP prior to intraoperative application and emphasizes the need for gas source and treatment time optimization for specific applications.

15.
Front Bioeng Biotechnol ; 11: 1169385, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37691907

RESUMO

Introduction: Autologous bone transplantation is successfully used in reconstructive surgery of large/critical-sized bone defects, whereby the microvascular free fibula flap is still regarded as the gold standard for the reconstruction of such defects in the head and neck region. Here, we report the morphological and lacunar properties of patient-paired bone samples from eight patients from the jaw (AB; recipient site) and the fibula (FB; donor site) on the micron length-scale using Synchrotron µ-CT. Insights into differences and similarities between these bone structures could offer a better understanding of the underlying mechanism for successful surgical outcomes and might clear the path for optimized, nature-inspired bone scaffold designs. Methods: Spatial vessel-pore arrangements, bone morphology, fluid-simulation derived permeability tensor, osteocyte lacunar density, and lacunar morphology are compared. Results: The orientation of the vessel system indicates a homogenous vessel orientation for AB and FB. The average mineral distance (50%) to the closest vessel boundary is higher in AB than in FB (the mean is 96 µm for AB vs. 76 µm for FB; p = 0.021). Average osteocyte lacunar density is found to be higher in AB than in FB (mean 22,874 mm3 vs. 19,376 mm3 for FB; p = 0.038), which might compensate for the high distance from the mineral to the nearest vessel. No significant differences in lacunar volume are found between paired AB and FB. Discussion: A comparable vessel network and similar distribution of vessel porosity between AB and FB may allow the FB graft to exhibit a high regeneration potential when connected to AB, and this might correlate with a high osteoinductive and osteoconductive potential of FB when connected to AB. Since widely used and potent synthetic bone grafts exist, new insight into the bone structure of well-established autologous bone grafts, such as the free fibula flap, could help to improve the performance of such materials and therefore the design of 3D scaffolds.

16.
J Comput Assist Tomogr ; 36(4): 469-76, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22805679

RESUMO

OBJECTIVE: Contrast between not fully mineralized tissues is weak and limits conventional computed tomography (CT). An automated grayscale histogram-based analysis features could improve the sensitivity to tissue alterations during early bone healing. MATERIALS AND METHODS: Tissue formation in a rat osteotomy model was analyzed using in vivo micro-CT and classified histologically (mineralized, cartilage, and connective tissues). A conventional threshold-based method including manual contouring was compared to a novel moment-based method: after removing the background peak, the histograms of each slice were characterized by their moments and analyzed as a function of the position along the long bone axis. RESULTS: The threshold-based method could differentiate between the mineralized and connective tissue (R = 0.73). The moment-based approach yielded a clear distinction between all 3 groups with a classification accuracy up to R = 0.93. CONCLUSIONS: The moment-based evaluation outperforms the conventional threshold-based CT analysis in sensitivity to the healing stage, user independence, and time consumption.


Assuntos
Osso e Ossos/diagnóstico por imagem , Cicatrização , Microtomografia por Raio-X/métodos , Algoritmos , Análise de Variância , Animais , Osso e Ossos/cirurgia , Osteotomia , Projetos Piloto , Ratos , Ratos Sprague-Dawley
17.
Materials (Basel) ; 15(9)2022 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-35591440

RESUMO

For the surgical technique of guided bone regeneration (GBR), the choice of available barrier membranes has until recently not included an option that is mechanically strong, durable, synthetic and resorbable. The most commonly used resorbable membranes are made from collagen, which are restricted in their mechanical strength. The purpose of this study is to evaluate the degradation and regeneration potential of a magnesium membrane compared to a collagen membrane. In eighteen beagle dogs, experimental bone defects were filled with bovine xenograft and covered with either a magnesium membrane or collagen membrane. The health status of the animals was regularly monitored and recorded. Following sacrifice, the hemimandibles were prepared for micro-CT (µ-CT) analysis. Complications during healing were observed in both groups, but ultimately, the regenerative outcome was similar between groups. The µ-CT parameters showed comparable results in both groups in terms of new bone formation at all four time points. In addition, the µ-CT analysis showed that the greatest degradation of the magnesium membranes occurred between 1 and 8 weeks and continued until week 16. The proportion of new bone within the defect site was similar for both treatment groups, indicating the potential for the magnesium membrane to be used as a viable alternative to collagen membranes. Overall, the new magnesium membrane is a functional and safe membrane for the treatment of defects according to the principles of GBR.

18.
Materials (Basel) ; 15(12)2022 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-35744169

RESUMO

Nowadays, the most commonly used fixation systems are non-resorbable, but new resorbable magnesium alloy fixation screws have been introduced recently. Therefore, the aim of this study was to compare the magnesium fixation screw and the commonly used non-resorbable titanium screw in an animal model. Four 3-wall defect sites were covered with collagen membranes in the mandible of twenty beagle dogs (two sites on the left and two on the right). Each membrane was fixed with either four magnesium screws or four titanium screws. Post-operative follow-up revealed the expected observations such as transient inflammation and pain. Both groups showed a good healing response, with no differences between groups. Micro-CT analysis showed no significant difference between groups in terms of BV/TV or soft tissue volume. The void volume in the magnesium fixation screw group continued to decrease on average between the different timepoints, but not significantly. Furthermore, a gradual progression of the degradation process of the magnesium screws was observed in the same group. Magnesium screws and titanium screws showed equal performance in tissue regeneration according to GBR principles. An additional advantage of magnesium screws is their resorbable nature, which eliminates the need for a second surgical step to remove the screws.

19.
Front Bioeng Biotechnol ; 10: 862395, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35782504

RESUMO

In oral- and maxillofacial bone augmentation surgery, non-vascularized grafts from the iliac crest demonstrate better clinical performance than alveolar bone grafts. The underlying mechanisms are not fully understood but are essential for the enhancement of bone regeneration scaffolds. Synchrotron Radiation µ-CT at a pixel size of 2.3 µm was used to characterize the gross morphology and the vascular and osteocyte lacuna porosity of patient-matched iliac crest/alveolar bone samples. The results suggest a difference in the spatial distribution of the vascular pore system. Fluid simulations reveal the permeability tensor to be more homogeneous in the iliac crest, indicating a more unidirectional fluid flow in alveolar bone. The average distance between bone mineral and the closest vessel pore boundary was found to be higher in alveolar bone. At the same time, osteocyte lacunae density is higher in alveolar bone, potentially compensating for the longer average distance between the bone mineral and vessel pores. The present study comprehensively quantified and compared the 3D microarchitecture of intraindividual human alveolar and iliac bone. The identified difference in pore network architecture may allow a bone graft from the iliac crest to exhibit higher regeneration potential due to an increased capacity to connect with the surrounding pore network of the residual bone. The results may contribute to understanding the difference in clinical performance when used as bone grafts and are essential for optimization of future scaffold materials.

20.
J Hazard Mater ; 430: 128356, 2022 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-35149499

RESUMO

Despite the increasing attention given to the impacts of nanoplastics in terrestrial environments, there is limited data about the effects on plants, and the quantitative information on uptake. In the present study, wheat plants grown in hydroponics were exposed to Pd-doped nanoplastics. This allowed us to quantify nanoplastics uptake and translocation to the shoots. Visualization of nanoplastics in roots was performed with synchrotron micro X-ray fluorescence (µXRF). Nanoplastics accumulated on the root epidermis, especially at the root tip and in root maturation zones. A close relationship between plant roots, rhizodeposits and nanoplastics behaviour was shown. Reinforcement of the cell wall in roots was evidenced using Fourier transform infrared spectroscopy (FTIR) and synchrotron-computed microtomography (µCT). Synchrotron-computed nanotomography (nanoCT) evidenced the presence of globular structures but they could not be identified as nanoplastics since they were observed both in the control and treated roots. By utilizing the inorganic tracer in the doped-nanoplastics, this study paves the road for elucidating interactions in more complex systems by using an integrative approach combining classical phytotoxicity markers with advanced nanometrology techniques.


Assuntos
Microplásticos , Plântula , Transporte Biológico , Hidroponia , Microplásticos/toxicidade , Raízes de Plantas/química , Triticum
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA