Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Sensors (Basel) ; 24(2)2024 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-38257438

RESUMO

Layer-by-layer (LbL) immobilization of DNA aptamers in the realm of electrochemical detection of heavy metal ions (HMIs) offers an enhancement in specificity, sensitivity, and low detection limits by leveraging the cross-reactivity obtained from multiple interactions between immobilized aptamers and developed material surfaces. In this research, we present a LbL approach for the immobilization of thiol- and amino-modified DNA aptamers on a Ag-incorporated cobalt-succinate metal-organic framework (MOF) (Ag@Co-Succinate) to achieve a cross-reactive effect on the electrochemical behavior of the sensor. The solvothermal method was utilized to synthesize Ag@Co-Succinate, which was also characterized through various techniques to elucidate its structure, morphology, and presence of functional groups, confirming its suitability as a host matrix for immobilizing both aptamers. The Ag@Co-Succinate aptasensor exhibited extraordinary sensitivity and selectivity towards Hg(II) ions in electrochemical detection, attributed to the unique binding properties of the immobilized aptamers. The exceptional limit of detection of 0.3 nM ensures the sensor's suitability for trace-level Hg(II) detection in various environmental and analytical applications. Furthermore, the developed sensor demonstrated outstanding repeatability, highlighting its potential for long-term and reliable monitoring of Hg(II).


Assuntos
Aptâmeros de Nucleotídeos , Mercúrio , Estruturas Metalorgânicas , Ácido Succínico , Succinatos , Íons
2.
Chemphyschem ; 24(16): e202300264, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37318900

RESUMO

The complexes of G-quadruplex forming DNA thrombin binding aptamers (TBA) and polyamidoamine dendrimers (PAMAM) were studied with the aim to form a model targeted drug delivery system. Hydrodynamic diameter, zeta potential and melting temperature (Tm ) were investigated by dynamic light scattering and UV-VIS spectrophotometry. Non-covalent adsorption by means of electrostatic interaction between positively charged amino groups of dendrimers (+) and negatively charged phosphate groups of aptamers (-) has driven the formation of aggregates. The size of complexes was in the range of 0.2-2 µm and depended on the type of dispersant, charge ratio (+/-) and temperature. Raising the temperature increased the polydispersity, new smaller size distributions were observed indicating the G-quadruplex unfolding. The melting transition temperature of TBA aptamer was affected by the presence of amino-terminated PAMAM rather than carboxylated succinic acid PAMAM-SAH dendrimer, thus supporting the electrostatic nature of interaction that disturbed denaturation of target-specific quadruplex aptamer structure.


Assuntos
Aptâmeros de Nucleotídeos , Dendrímeros , Dendrímeros/química , Difusão Dinâmica da Luz , Espectrofotometria
3.
Methods ; 197: 54-62, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33677061

RESUMO

Biosensing atomic force microscopy (AFM) offers the unique feature to determine the energy landscape of a bimolecular interaction at the real single molecule level. Furthermore, simultaneous and label-free mapping of molecular recognition and the determination of sample topography at the nanoscale gets possible. A prerequisite and one of the major parts in biosensing AFM are the bio-functionalized AFM tips. In the past decades, different approaches for tip functionalization have been developed. Using these functionalization strategies, several biological highly relevant interactions at the single molecule level have been explored. For the most common approach, the use of a heterobifunctional poly(ethylenglycol) crosslinker, a broad range of linkers for different chemical coupling strategies is available. Nonetheless, the time consuming functionalization protocol as well as the broad distribution of rupture length reduces the possibility of automation and may reduce the accuracy of the results. Here we present a stable and fast forward approach based on tetra-functional DNA tetrahedra. A fast functionalization and a sharp defined distribution of rupture length gets possible with low effort and high success rate. We tested the performance on the classical avidin biotin system by using tetrahedra with three disulfide legs for stable and site directed coupling to gold coated tips and a biotinylated end at the fourth vertex. A special advantage appears when working with a DNA aptamer as sensing molecule. In this case, the fourth strand can be extended by a certain DNA sequence complementary to the linkage part of an aptamer. This AFM tip functionalization protocol was applied on thrombin using DNA aptamers directed against the fibrinogen binding side of human thrombin.


Assuntos
Aptâmeros de Nucleotídeos , Avidina , Aptâmeros de Nucleotídeos/metabolismo , Avidina/química , Avidina/metabolismo , Biotina/química , DNA , Humanos , Microscopia de Força Atômica/métodos
4.
Sensors (Basel) ; 23(18)2023 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-37765843

RESUMO

Aptamers are short oligonucleotides designed to possess high binding affinity towards specific target compounds (ions, molecules, or cells). Due to their function and unique advantages, aptamers are considered viable alternatives to antibodies as biorecognition elements in bioassays and biosensors. On the other hand, paper-based devices (PADs) have emerged as a promising and powerful technology for the fabrication of low-cost analytical tools, mainly intended for on-site and point-of-care applications. The present work aims to provide a comprehensive overview of paper-based aptasensors. The review describes the fabrication methods and working principles of paper-based devices, the properties of aptamers as bioreceptors, the different modes of detection used in conjunction with aptasensing PADs, and representative applications for the detection of ions, small molecules, proteins, and cells. The future challenges and prospects of these devices are also discussed.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Anticorpos
5.
Analyst ; 147(3): 461-470, 2022 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-34989356

RESUMO

Proteolysis of milk proteins, such as caseins, caused by milk proteases, can change the organoleptic and nutritional characteristics of milk, and therefore it is essential to monitor this enzymatic activity. We used trypsin as a model protease because of its role as a biomarker for pancreatitis. The aim of this work was to demonstrate the detection of proteolysis of ß-casein by trypsin using a multiharmonic quartz crystal microbalance (QCM) biosensor. The ß-casein layer was deposited from a 0.1 mg mL-1 solution on a hydrophobic surface consisting of a self-assembled monolayer of 1-dodecanethiol on the gold electrode of the QCM. The addition of an increasing concentration of trypsin leads to the removal of the casein layer due to proteolysis, and correlates with an increase in the resonant frequency of the QCM. We investigated the effect of trypsin concentrations (0.3-20 nM) on the kinetics of the proteolysis of ß-casein and demonstrated that the frequency increase is proportional to the protease concentration. Consequently, an inverse Michaelis-Menten model was used to estimate the Michaelis-Menten constant (KM = 0.38 ± 0.02 nM) and the limit of detection (LOD = 0.16 ± 0.02 nM). The thickness, mass and viscoelastic properties of the protein adlayer after its formation and following the proteolytic cleavage were evaluated by means of multi-harmonic analysis. We found that ß-casein is preferably adsorbed on the hydrophobic surfaces as an asymmetrical double layer, of which the innermost layer was found to be denser and thinner (about 2.37 nm) and the outermost layer was found to be less tightly bound and thicker (about 3.5 nm).


Assuntos
Caseínas , Técnicas de Microbalança de Cristal de Quartzo , Acústica , Adsorção , Animais , Leite , Tripsina
6.
Sensors (Basel) ; 22(5)2022 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-35270999

RESUMO

Milk is a significant foodstuff around the world, being produced and consumed in large quantities. The safe consumption of milk requires that the liquid has an acceptably low level of microbial contamination and has not been subjected to spoiling. Bacterial safety limits in milk vary by country but are typically in the thousands per mL of sample. To rapidly determine if samples contain an unsafe level of bacteria, an aptamer-based sensor specific to Escherichia coli bacteria was developed. The sensor is based on an ultra-high frequency electromagnetic piezoelectric acoustic sensor device (EMPAS), with the aptamer being covalently bound to the sensor surface by the anti-fouling linker, MEG-Cl. The sensor is capable of the selective measurement of E. coli in PBS and in cow's milk samples down to limits of detection of 35 and 8 CFU/mL, respectively, which is well below the safe limits for commercial milk products. This sensing system shows great promise for the milk industry for the purpose of rapid verification of product safety.


Assuntos
Incrustação Biológica , Leite , Animais , Bactérias , Incrustação Biológica/prevenção & controle , Escherichia coli , Som
7.
Sensors (Basel) ; 22(10)2022 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-35632093

RESUMO

Antibiotics are often used in human and veterinary medicine for the treatment of bacterial diseases. However, extensive use of antibiotics in agriculture can result in the contamination of common food staples such as milk. Consumption of contaminated products can cause serious illness and a rise in antibiotic resistance. Conventional methods of antibiotics detection such are microbiological assays chromatographic and mass spectroscopy methods are sensitive; however, they require qualified personnel, expensive instruments, and sample pretreatment. Biosensor technology can overcome these drawbacks. This review is focused on the recent achievements in the electrochemical biosensors based on nucleic acid aptamers for antibiotic detection. A brief explanation of conventional methods of antibiotic detection is also provided. The methods of the aptamer selection are explained, together with the approach used for the improvement of aptamer affinity by post-SELEX modification and computer modeling. The substantial focus of this review is on the explanation of the principles of the electrochemical detection of antibiotics by aptasensors and on recent achievements in the development of electrochemical aptasensors. The current trends and problems in practical applications of aptasensors are also discussed.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Antibacterianos , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Cromatografia , Inocuidade dos Alimentos , Humanos
8.
Langmuir ; 37(4): 1542-1550, 2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33475368

RESUMO

The unavailability of effective and safe human immunodeficiency virus (HIV) vaccines incites several approaches for development of the efficient antigen/adjuvant vaccination composite. In this study, three different dendronized gold nanoparticles (AuNPs 13-15) were investigated for a complexation ability with gp160 synthetic peptides derived from an HIV envelope. It has been shown that HIV peptides interacted with nanoparticles as evident from the changes in their secondary structures, restricted the mobility of the attached fluorescence dye, and enhanced peptide helicity confirmed by the fluorescence polarization and circular dichroism results. Transmission electron microscopy visualized complexes as cloud-like structures with attached nanoparticles. AuNP 13-15 nanoparticles bind negatively charged peptides depending on the number of functional groups; the fastest saturation and peptide retardation were observed for the most dendronized nanoparticle as indicated from dynamic light scattering, laser Doppler velocimetry, and agarose gel electrophoresis experiments. Dendronized gold nanoparticles can be considered one of the potential HIV peptide-based vaccination platforms.


Assuntos
HIV-1 , Nanopartículas Metálicas , Ouro , Proteína gp160 do Envelope de HIV , Humanos , Microscopia Eletrônica de Transmissão , Peptídeos
9.
Sensors (Basel) ; 21(16)2021 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-34451028

RESUMO

A multiharmonic quartz crystal microbalance (QCM) has been applied to study the viscoelastic properties of the aptamer-based sensing layers at the surface of a QCM transducer covered by neutravidin following interaction with bacteria Listeria innocua. Addition of bacteria in the concentration range 5 × 103-106 CFU/mL resulted in a decrease of resonant frequency and in an increase of dissipation. The frequency decrease has been lower than one would expect considering the dimension of the bacteria. This can be caused by lower penetration depth of the acoustics wave (approximately 120 nm) in comparison with the thickness of the bacterial layer (approximately 500 nm). Addition of E. coli at the surface of neutravidin as well as aptamer layers did not result in significant changes in frequency and dissipation. Using the Kelvin-Voight model the analysis of the viscoelastic properties of the sensing layers was performed and several parameters such as penetration depth, Γ, viscosity coefficient, η, and shear modulus, µ, were determined following various modifications of QCM transducer. The penetration depth decreased following adsorption of the neutravidin layer, which is evidence of the formation of a rigid protein structure. This value did not change significantly following adsorption of aptamers and Listeria innocua. Viscosity coefficient was higher for the neutravidin layer in comparison with the naked QCM transducer in a buffer. However, a further increase of viscosity coefficient took place following attachment of aptamers suggesting their softer structure. The interaction of Listeria innocua with the aptamer layer resulted in slight decrease of viscosity coefficient. The shearing modulus increased for the neutravidin layer and decreased following aptamer adsorption, while a slight increase of µ was observed after the addition of Listeria innocua.


Assuntos
Escherichia coli , Técnicas de Microbalança de Cristal de Quartzo , Adsorção , Listeria , Propriedades de Superfície , Viscosidade
10.
Int J Mol Sci ; 22(5)2021 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-33800897

RESUMO

Neutrophil-mediated innate host defense mechanisms include pathogen elimination through bacterial phagocytosis, which activates the 5-lipoxygenase (5-LOX) product synthesis. Here, we studied the effect of synthetic oligodeoxyribonucleotides (ODNs), which mimic the receptor-recognized sites of bacterial (CpG-ODNs) and genomic (G-rich ODNs) DNAs released from the inflammatory area, on the neutrophil functions after cell stimulation with Salmonella typhimurium. A possible mechanism for ODN recognition by Toll-like receptor 9 (TLR9) and RAGE receptor has been proposed. We found for the first time that the combination of the magic peptide LRR11 from the leucine-rich repeat (LRR) of TLR9 with the CpG-ODNs modulates the uptake and signaling from ODNs, in particular, dramatically stimulates 5-LOX pathway. Using thickness shear mode acoustic method, we confirmed the specific binding of CpG-ODNs, but not G-rich ODN, to LRR11. The RAGE receptor has been shown to play an important role in promoting ODN uptake. Thus, FPS-ZM1, a high-affinity RAGE inhibitor, suppresses the synthesis of 5-LOX products and reduces the uptake of ODNs by neutrophils; the inhibitor effect being abolished by the addition of LRR11. The results obtained revealed that the studied peptide-ODN complexes possess high biological activity and can be promising for the development of effective vaccine adjuvants and antimicrobial therapeutics.


Assuntos
Araquidonato 5-Lipoxigenase/metabolismo , Leucotrienos/biossíntese , Neutrófilos/metabolismo , Fragmentos de Peptídeos/farmacologia , Receptor Toll-Like 9/fisiologia , Benzamidas/farmacologia , Cálcio/metabolismo , Ilhas de CpG , Ativação Enzimática/efeitos dos fármacos , Humanos , Cinética , Neutrófilos/efeitos dos fármacos , Oligodesoxirribonucleotídeos/síntese química , Oligodesoxirribonucleotídeos/farmacologia , Proteínas Opsonizantes , Espécies Reativas de Oxigênio/metabolismo , Receptor para Produtos Finais de Glicação Avançada/antagonistas & inibidores , Salmonella typhimurium
11.
Sensors (Basel) ; 20(19)2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-33003538

RESUMO

This review is focused on the application of surface and volume-sensitive acoustic methods for the detection of milk proteases such as trypsin and plasmin. While trypsin is an important protein of human milk, plasmin is a protease that plays an important role in the quality of bovine, sheep and goat milks. The increased activity of plasmin can cause an extensive cleavage of ß-casein and, thus, affect the milk gelation and taste. The basic principles of surface-sensitive acoustic methods, as well as high-resolution ultrasonic spectroscopy (HR-US), are presented. The current state-of-the-art examples of the application of acoustic sensors for protease detection in real time are discussed. The application of the HR-US method for studying the kinetics of the enzyme reaction is demonstrated. The sensitivity of the acoustics biosensors and HR-US methods for protease detection are compared.


Assuntos
Caseínas , Leite/enzimologia , Peptídeo Hidrolases/metabolismo , Acústica , Animais , Bovinos , Fibrinolisina/metabolismo , Cabras , Ovinos
12.
Sensors (Basel) ; 20(17)2020 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-32839389

RESUMO

The determination of antibiotics in food is important due to their negative effect on human health related to antimicrobial resistance problem, renal toxicity, and allergic effects. We propose an impedimetric aptasensor for the determination of kanamycin A (KANA), which was assembled on the glassy carbon electrode by the deposition of carbon black in a chitosan matrix followed by carbodiimide binding of aminated aptamer mixed with oligolactide derivative of thiacalix[4]arene in a cone configuration. The assembling was monitored by cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy. In the presence of the KANA, the charge transfer resistance of the inner interface surprisingly decreased with the analyte concentration within 0.7 and 50 nM (limit of detection 0.3 nM). This was attributed to the partial shielding of the negative charge of the aptamer and of its support, a highly porous 3D structure of the surface layer caused by a macrocyclic core of the carrier. The use of electrostatic assembling in the presence of cationic polyelectrolyte decreased tenfold the detectable concentration of KANA. The aptasensor was successfully tested in the determination of KANA in spiked milk and yogurt with recoveries within 95% and 115%.

13.
Sensors (Basel) ; 20(23)2020 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-33291498

RESUMO

Metal-organic frameworks (MOFs) offer a unique variety of properties and morphology of the structure that make it possible to extend the performance of existing and design new electrochemical biosensors. High porosity, variable size and morphology, compatibility with common components of electrochemical sensors, and easy combination with bioreceptors make MOFs very attractive for application in the assembly of electrochemical aptasensors. In this review, the progress in the synthesis and application of the MOFs in electrochemical aptasensors are considered with an emphasis on the role of the MOF materials in aptamer immobilization and signal generation. The literature information of the use of MOFs in electrochemical aptasensors is classified in accordance with the nature and role of MOFs and a signal mode. In conclusion, future trends in the application of MOFs in electrochemical aptasensors are briefly discussed.

14.
Chemphyschem ; 20(4): 545-554, 2019 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-30552789

RESUMO

By using the thickness shear mode acoustics method (TSM) and single-molecule force spectroscopy (SMFS) we studied the interactions between DNA aptamers (sgc8c) specific to the protein tyrosine kinase 7 (PTK7), which is localized in the membranes of leukemia lymphoblastics (MOLT-4), and lymphocyte (Jurkat) cell lines, as well with PTK7-negative U266 myeloid leukemia cells. The TSM method allowed the development of a highly sensitive, label-free biosensor for the detection leukemia cells with a limit of detection of (195±20) cells/mL. SMFS approved the high selectivity of the sgc8c aptamers to the PTK7 receptors at the cell surface and allowed determining the binding probability of the aptamers to the PTK7 receptors at different cell lines.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , DNA/química , Leucemia/diagnóstico , Acústica , Moléculas de Adesão Celular/química , Linhagem Celular Tumoral , Humanos , Leucemia/sangue , Limite de Detecção , Receptores Proteína Tirosina Quinases/química
15.
Chemphyschem ; 20(23): 3177-3180, 2019 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-31639248

RESUMO

Herein, we report ultrasound-propelled graphene-oxide coated gold nanowire motors, functionalized with fluorescein-labeled DNA aptamers (FAM-AIB1-apt), for qualitative detection of overexpressed AIB1 oncoproteins in MCF-7 breast cancer cells. The movement of nanomotors under the ultrasound field facilitated intracellular uptake and resulted in a faster aptamer binding with the target protein and thus faster fluorescence recovery. The propulsion behavior of the aptamer functionalized nanomotors greatly enhanced the fluorescence intensity compared to static conditions. The new aptamer@nanomotor-based strategy offers considerable potential for further development of sensing methodologies towards diagnosis of breast cancer.


Assuntos
Aptâmeros de Nucleotídeos/metabolismo , Fluoresceína/química , Aptâmeros de Nucleotídeos/química , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Feminino , Ouro/química , Humanos , Células MCF-7 , Microscopia Eletrônica de Varredura , Nanotecnologia/instrumentação , Nanotecnologia/métodos , Nanofios/química , Sonicação
16.
Sensors (Basel) ; 19(3)2019 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-30678376

RESUMO

A DNA sensor has been proposed on the platform of glassy carbon electrode modified with native DNA implemented between two electropolymerized layers of polyaniline. The surface layer was assembled by consecutive stages of potentiodynamic electrolysis, DNA drop casting, and second electrolysis, which was required for capsulation of the DNA molecules and prevented their leaching into the solution. Surface layer assembling was controlled by cyclic voltammetry, electrochemical impedance spectroscopy, atomic force, and scanning electron microscopy. For doxorubicin measurement, the DNA sensor was first incubated in the Methylene blue solution that amplified signal due to DNA intercalation and competition with the doxorubicin molecules for the DNA binding sites. The charge transfer resistance of the inner layer interface decreased with the doxorubicin concentration in the range from 1.0 pM to 0.1 µM (LOD 0.6 pM). The DNA sensor was tested for the analysis of spiked artificial urine samples and showed satisfactory recovery in concentration range of 0.05⁻10 µM. The DNA sensor developed can find application in testing of antitumor drugs and some other DNA damaging factors.


Assuntos
DNA/química , Doxorrubicina/química , Técnicas Eletroquímicas/métodos , Compostos de Anilina/química , Técnicas Biossensoriais/métodos , Espectroscopia Dielétrica/métodos
17.
Sensors (Basel) ; 19(22)2019 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-31739501

RESUMO

DNA sensors were assembled by consecutive deposition of thiacalix[4]arenes bearing oligolactic fragments, poly(ethylene imine), and DNA onto the glassy carbon electrode. The assembling of the layers was monitored with scanning electron microscopy, cyclic voltammetry and electrochemical impedance spectroscopy. The configuration of the thiacalix[4]arene core determined self-assembling of the polymeric species to the nano/micro particles with a size of 70-350 nm. Depending on the granulation, the coatings show the accumulation of a variety of DNA quantities, charges, and internal pore volumes. These parameters were used to optimize the DNA sensors based on these coatings. Thus, doxorubicin was determined to have limits of detection of 0.01 nM (cone configuration), 0.05 nM (partial cone configuration), and 0.10 nM (1,3-alternate configuration of the macrocycle core). Substitution of native DNA with aptamer specific to aflatoxin M1 resulted in the detection of the toxin in the range of 20 to 200 ng/L (limit of detection 5 ng/L). The aptasensor was tested in spiked milk samples and showed a recovery of 80 and 85% for 20 and 50 ng/L of the aflatoxin M1, respectively.


Assuntos
Aflatoxina M1/isolamento & purificação , Técnicas Biossensoriais , DNA/química , Poliésteres/química , Aflatoxina M1/química , Animais , Aptâmeros de Nucleotídeos/química , Carbono/química , Bovinos , Espectroscopia Dielétrica , Ouro/química , Humanos , Microscopia Eletrônica de Varredura , Leite/química , Leite/microbiologia
18.
Analyst ; 143(15): 3686-3692, 2018 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-29978167

RESUMO

Graphene oxide (GO), a partially oxidized two-dimensional allotrope of carbon, is an attractive nanocarrier for cancer diagnostics and therapy. The nanometer-sized GO is known to permeate cell membranes. Herein we studied the cellular uptake pathways of GO nanoflakes by cancer and non-cancerous cell lines. By employing confocal Raman imaging, we were able to track the GO cellular uptake in living cells (C33 and MDCK) without any additional fluorescent or plasmonic labels. This specific progress in label-free Raman imaging of GO facilitates the monitoring of nanoflakes at the cellular level.


Assuntos
Grafite/metabolismo , Microscopia Confocal , Nanopartículas/metabolismo , Análise Espectral Raman , Animais , Linhagem Celular Tumoral , Cães , Humanos , Células Madin Darby de Rim Canino , Oxirredução , Óxidos
19.
Gen Physiol Biophys ; 37(5): 597-601, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30307406

RESUMO

The commercial solution of fourth generation (G4) of poly-amidoamine (PAMAM) dendrimers contains methanol, which is toxic for human body. Our differential scanning calorimetry (DSC) study of dendrimers confirmed the existence of this threat. The recommendation is done on how to prepare dendrimer solutions for practical and safely use in gene delivery. DSC have been also used to study the thermodynamic properties of DNA/dendrimer complexes (dendriplexes). We showed that up to DNA/dendrimer ratio 43 ± 3 (w/w) the solution was homogeneous, but stable aggregates were formed at higher PAMAM content. DSC experiments performed with homogeneous solution of dendriplexes revealed existence of the pH-dependent melting curves that contain several endothermic peaks associated with melting of GC-rich regions.


Assuntos
DNA/metabolismo , Dendrímeros/metabolismo , DNA/química , Dendrímeros/toxicidade , Quadruplex G/efeitos dos fármacos , Modelos Moleculares , Termodinâmica
20.
Sensors (Basel) ; 18(12)2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30513767

RESUMO

We performed a comparative analysis of the sensitivity of aptamer-based biosensors for detection mycotoxin aflatoxin M1 (AFM1) depending on the method of immobilization of DNA aptamers and method of the detection. Label-free electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) for ferrocene labeled neutravidin layers were used for this purpose. Amino-modified DNA aptamers have been immobilized at the surface of polyamidoamine dendrimers (PAMAM) of fourth generation (G4) or biotin-modified aptamers were immobilized at the neutravidin layer chemisorbed at gold surface. In the first case the limit of detection (LOD) has been determined as 8.47 ng/L. In the second approach the LOD was similar 8.62 ng/L, which is below of allowable limits of AFM1 in milk and milk products. The aptasensors were validated in a spiked milk samples with good recovery better than 78%. Comparative analysis of the sensitivity of immuno- and aptasensors was also performed and showed comparable sensitivity.


Assuntos
Aflatoxina M1/isolamento & purificação , Técnicas Biossensoriais/métodos , Espectroscopia Dielétrica , Leite/química , Aflatoxina M1/química , Animais , Aptâmeros de Nucleotídeos/química , Aptâmeros de Nucleotídeos/genética , Avidina/química , Bovinos , Ouro/química , Humanos , Limite de Detecção , Oxirredução
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA