Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Oncologist ; 23(4): 403-409, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29317553

RESUMO

BACKGROUND: Evaluation of adverse events (AEs) in pivotal registration trials and ongoing postmarketing surveillance is important for all biologics, including biosimilars. A combined analysis of two pivotal registration studies was performed to strengthen evidence on safety for biosimilar filgrastim EP2006 in patients with breast cancer receiving myelosuppressive chemotherapy, a sensitive clinical setting to confirm biosimilarity of filgrastim. MATERIALS AND METHODS: Data were combined from two phase III studies of biosimilar filgrastim EP2006. The U.S. registration study was a randomized, double-blind comparison of biosimilar and reference filgrastim in women aged ≥18 years with breast cancer, receiving (neo)adjuvant treatment with TAC (docetaxel + doxorubicin + cyclophosphamide). The European Union registration study was a single-arm, open-label study of biosimilar filgrastim in women aged ≥18 years with breast cancer receiving doxorubicin + docetaxel. Patients received filgrastim as a subcutaneous injection on day 2 of each cycle for <14 days or until the absolute neutrophil count reached 10 × 109/L after the expected nadir. Results were combined for cycles 1-4. RESULTS: A total of 277 patients received biosimilar filgrastim EP2006. Patients had a mean (± standard deviation) age of 51.1 (± 10.8) years, and 78.7% of patients had stage II or III breast cancer. A total of 46 (20.6%) patients receiving biosimilar filgrastim had AEs considered filgrastim-related. The most frequently reported filgrastim-related AEs were musculoskeletal or connective tissue disorders (15.2%), including bone pain (7.2%). One death (due to pulmonary embolism) occurred of a patient receiving biosimilar filgrastim (not considered filgrastim-related). No patient developed antidrug antibodies during the study. CONCLUSION: Biosimilar filgrastim has a safety profile consistent with previous filgrastim studies and is effective in preventing febrile neutropenia in patients with breast cancer. IMPLICATIONS FOR PRACTICE: The biosimilar filgrastim EP2006 (Zarzio, Zarxio, biosimilar filgrastim-sndz) has been approved in Europe since 2009 and in the U.S. since 2015. This combined analysis of two phase III studies provides additional clinical evidence that the biosimilar filgrastim EP2006 has a safety profile consistent with previous studies of reference filgrastim and supports large postmarketing studies of EP2006 in Europe. Strengthening the evidence for biosimilar filgrastim can help improve acceptance of biosimilars and increase patient access to biologics.


Assuntos
Medicamentos Biossimilares/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Filgrastim/uso terapêutico , Fármacos Hematológicos/uso terapêutico , Neutropenia/prevenção & controle , Adulto , Idoso , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Medicamentos Biossimilares/efeitos adversos , Neoplasias da Mama/patologia , Ensaios Clínicos Fase III como Assunto , Método Duplo-Cego , Feminino , Filgrastim/efeitos adversos , Fármacos Hematológicos/efeitos adversos , Humanos , Pessoa de Meia-Idade , Terapia Neoadjuvante , Estadiamento de Neoplasias , Neutropenia/induzido quimicamente , Segurança , Resultado do Tratamento
2.
Clin Nephrol ; 89 (2018)(1): 1-9, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29168688

RESUMO

AIMS: To assess real-world effectiveness and safety of intravenous (IV) HX575, a biosimilar epoetin-α, in hemodialysis (HD) patients. MATERIALS AND METHODS: This prospective, observational, pharmacoepidemiological study of adult HD patients treated with IV HX575 for renal anemia for up to 24 months was conducted in 114 centers in 10 European countries. Of 2,086 enrolled subjects (safety sample), 2,023 had ≥ 1 follow-up visit (effectiveness sample). RESULTS: Most (59.3%) patients were male, median age was 68 years. At enrollment, most (82.5%) had been treated with an erythropoiesis-stimulating agent, and 73.0% had adequate iron stores. At baseline, mean (± standard deviation) baseline hemoglobin (Hb) was 11.09 (± 1.14) g/dL and HX575 dose 106.5 (± 78.7) international units (IU)/kg/week; at month 24, Hb was 11.25 (± 1.19) g/dL and HX575 dose 113.0 (± 102.5) IU/kg/week. Variations in mean HX575 dose and Hb over the study were not statistically significant. As to safety, 140 patients (6.7%) experienced ≥ 1 adverse event; of these, 19 events (16 patients; 0.8%) were related to HX575 treatment, 148 (108 patients; 5.2%) were reported as serious, including 12 events in 11 patients (0.5%) stated to be related. No cases of anti-epoetin antibodies or pure red cell aplasia were reported. CONCLUSIONS: MONITOR-CKD5 confirmed the real-world effectiveness and safety profile of IV biosimilar HX575. HD patients treated for up to 24 months showed stable dosing patterns and Hb outcomes. The safety profile of HX575 is likewise comparable to reference epoetin-α.
.


Assuntos
Anemia , Epoetina alfa , Hematínicos , Falência Renal Crônica , Diálise Renal , Idoso , Anemia/complicações , Anemia/tratamento farmacológico , Medicamentos Biossimilares , Epoetina alfa/administração & dosagem , Epoetina alfa/uso terapêutico , Feminino , Hematínicos/administração & dosagem , Hematínicos/uso terapêutico , Hemoglobinas/análise , Humanos , Falência Renal Crônica/complicações , Falência Renal Crônica/terapia , Masculino , Estudos Prospectivos
3.
Eur Heart J ; 34(10): 775-81, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22390914

RESUMO

AIMS: Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. METHODS AND RESULTS: In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. CONCLUSION: In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Angiografia por Ressonância Magnética/efeitos adversos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
4.
J Cardiovasc Magn Reson ; 14: 61, 2012 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-22938651

RESUMO

BACKGROUND: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. METHODS: In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. RESULTS: The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1-3 vessel disease and p = 0.015, n = 140 in MVD). CONCLUSION: In this large multicenter, multivendor study the diagnostic performance of perfusion-CMR to detect CAD was superior to perfusion SPECT in the entire population and in sub-groups. Perfusion-CMR can be recommended as an alternative for SPECT imaging. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT00977093.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Circulação Coronária , Imagem Cinética por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doença da Artéria Coronariana/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
5.
Magn Reson Med ; 66(6): 1731-8, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21702061

RESUMO

Myocardial perfusion images can be affected by the dark rim artifact. This study aimed to evaluate the effects of the spatial resolution and heart rate on the transmural extent of the artifact. Six pigs under anesthesia were scanned at 1.5T using an echo-planar imaging/fast gradient echo sequence with a nonselective saturation preparation pulse. Three short-axis slices were acquired every heart beat during the first pass of a contrast agent bolus. Two different in-plane spatial resolutions (2.65 and 3.75 mm) and two different heart rates (normal and tachycardia) were used, generating a set of four perfusion scans. The percentage drop of signal in the subendocardium compared to the epicardium and the transmural extent of the artifact were extracted. Additionally, the signal-to-noise and the contrast-to-noise ratios were evaluated. The signal drop as well as the width of the dark rim artifact increased with decreased spatial resolution and with increased heart rates. No significant slice-to-slice variability was detected for signal drop and width of the rim within the four considered groups. signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) ratios decreased with increasing spatial resolution. In conclusion, low spatial and temporal resolution could be correlated with increased extent of the dark-rim artifact and with lower SNR and CNR.


Assuntos
Artefatos , Frequência Cardíaca/fisiologia , Coração/anatomia & histologia , Coração/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Animais , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA