Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Herz ; 44(6): 477-482, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31187193

RESUMO

Chronic obstructive pulmonary disease (COPD) primarily affects the lungs; however, cardiovascular conditions are among the most common extrapulmonary comorbidities. Besides shared risk factors such as cigarette smoking, pathophysiological connections between the lung and the heart have been identified as mediators of reduced cardiac output. Recent research has focused on hyperinflation of the lung as a pulmonary cause for heart dysfunction. Hyperinflation is a typical lung abnormality seen in COPD; it is characterized by increased residual volume, intrathoracic gas volume, and total lung capacity while vital capacity is decreased. The degree of hyperinflation with airway obstruction is inversely related to left ventricular filling, stroke volume, and cardiac output. The underlying mechanisms are assumed to be compression of the pulmonary veins and thus reduced preload of the left heart as well as decreased pulmonary microvascular blood flow due to compression of the pulmonary vasculature. Treatment with a dual bronchodilator antagonizes this detrimental lung-heart unbalance effectively: Pulmonary blood flow, left ventricular end-diastolic volume, and stroke volume increase in COPD patients without cardiac abnormalities. Similar effects, yet less pronounced, were reported with single bronchodilator therapy. Future work needs to investigate whether these promising findings can be reproduced in COPD patients with cardiovascular diseases.


Assuntos
Broncodilatadores , Doença Pulmonar Obstrutiva Crônica , Volume Sistólico , Coração/fisiopatologia , Humanos , Testes de Função Respiratória
2.
Clin Exp Allergy ; 47(11): 1445-1455, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28696503

RESUMO

BACKGROUND: Subcutaneous allergen immunotherapy with grass pollen allergoids has been proven to be effective and safe in the treatment of patients with allergic rhinoconjunctivitis. Based on the extensive cross-reactivity among Pooideae species, it has been suggested that grass pollen extracts could be prepared from a single species, rather than from a multiple species mixture. OBJECTIVE: To find the optimal dose of a Phleum pratense (P. pratense) allergoid preparation and compare its efficacy and safety to a 6-grass pollen allergoid preparation. METHODS: In this double-blind, placebo-controlled study (EudraCT: 2011-000674-58), three doses of P. pratense allergoid (1800 therapeutic units (TU), standard-dose 6000 TU and 18 000 TU) were compared with placebo and the marketed 6-grass pollen allergoid (6000 TU). In a pre-seasonal dosing regimen, 102 patients were randomized to five treatment groups and received nine subcutaneous injections. The primary efficacy endpoint was the change in weal size (late-phase reaction [LPR]) in response to the intracutaneous testing (ICT) before and after treatment, comparing the active allergoids to placebo. Secondary outcomes were the change in Total Nasal Symptom Score (TNSS) assessed in the allergen exposure chamber (AEC), the changes in P. pratense-serum-specific IgG4 and the incidence of adverse events (AEs). RESULTS: All three doses of the P. pratense and the 6-grass pollen allergoid preparations were significantly superior to placebo for the primary outcome, whereas there were no significant differences in the change in TNSS. Compared to the standard-dose, the high-dose of P. pratense did not produce any additional significant benefit, but showed a slight increase in AEs. Yet this increase in AEs was lower than for the 6-grass pollen preparation. CONCLUSIONS & CLINICAL RELEVANCE: The standard-dose of the new P. pratense allergoid was comparable to the marketed 6-grass pollen preparation at equal dose for the parameters measured.


Assuntos
Alérgenos/imunologia , Relação Dose-Resposta Imunológica , Phleum/efeitos adversos , Extratos Vegetais/imunologia , Pólen/imunologia , Rinite Alérgica Sazonal/imunologia , Rinite Alérgica Sazonal/terapia , Adolescente , Adulto , Idoso , Alergoides , Dessensibilização Imunológica/efeitos adversos , Dessensibilização Imunológica/métodos , Feminino , Alemanha , Humanos , Imunoglobulina E/imunologia , Imunoglobulina G/imunologia , Masculino , Pessoa de Meia-Idade , Extratos Vegetais/administração & dosagem , Rinite Alérgica Sazonal/diagnóstico , Imunoterapia Sublingual , Resultado do Tratamento , Adulto Jovem
3.
Allergy ; 72(7): 1035-1042, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28122133

RESUMO

BACKGROUND: Allergen exposure chambers (AECs) are clinical facilities allowing for controlled exposure of subjects to allergens in an enclosed environment. AECs have contributed towards characterizing the pathophysiology of respiratory allergic diseases and the pharmacological properties of new therapies. In addition, they are complementary to and offer some advantages over traditional multicentre field trials for evaluation of novel therapeutics. To date, AEC studies conducted have been monocentric and have followed protocols unique to each centre. Because there are technical differences among AECs, it may be necessary to define parameters to standardize the AECs so that studies may be extrapolated for driving basic immunological research and for marketing authorization purposes by regulatory authorities. METHODS: For this task force initiative of the European Academy of Allergy and Clinical Immunology (EAACI), experts from academia and regulatory agencies met with chamber operators to list technical, clinical and regulatory unmet needs as well as the prerequisites for clinical validation. RESULTS: The latter covered the validation process, standardization of challenges and outcomes, intra- and interchamber variability and reproducibility, in addition to comparability with field trials and specifics of paediatric trials and regulatory issues. CONCLUSION: This EAACI Position Paper aims to harmonize current concepts in AECs and to project unmet needs with the intent to enhance progress towards use of these facilities in determining safety and efficacy of new therapeutics in the future.


Assuntos
Alérgenos/imunologia , Dessensibilização Imunológica/métodos , Ambiente Controlado , Exposição por Inalação , Dessensibilização Imunológica/normas , Dessensibilização Imunológica/tendências , Política de Saúde , Humanos , Hipersensibilidade/imunologia , Hipersensibilidade/terapia , Exposição por Inalação/efeitos adversos , Reprodutibilidade dos Testes
5.
Allergy ; 71(12): 1693-1700, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27255590

RESUMO

BACKGROUND: Efficacy testing of immunotherapy in field studies is often hampered by variation of airborne allergens. Standardized allergen exposure in challenge chamber settings might be an alternative. Therefore, we developed a universal technique to create an atmosphere loaded with allergen particles of adjustable size from aqueous solutions of licensed allergen extracts. OBJECTIVE: The aim of this study was to apply this technique and test the safety and efficacy of challenges with house dust mite (HDM) allergen in the Fraunhofer allergen challenge chamber. METHODS: Aerosol particles carrying HDM allergen were produced by spray-drying of an aqueous solution containing HDM allergen and lactose. In a monocenter, placebo-controlled, single-blind, dose-escalation pilot study, 18 subjects with perennial allergic rhinitis and sensitization to HDM were exposed to HDM allergen for 4 h at either 250, 500, 1000 SQE/m3 or lactose alone (0 SQE/m3 ) 7 days apart. The dose of 500 SQE/m³ was repeated to investigate reproducibility. Total nasal symptom score (TNSS) was the primary endpoint. RESULTS: Exposure to HDM increased TNSS (mean ± SD) to 3.4 ± 1.8, 3.3 ± 2.1, and 3.6 ± 2.0 at 250, 500 and 1000 SQE/m3 , respectively, while lactose alone did not change TNSS (0.7 ± 0.6). The results were reproducible at 500 SQE/m3 . Pulmonary function and adverse event frequency did not change with escalation of allergen dose. CONCLUSION: This HDM allergen particle generation is safe, specific and reproducible and can therefore be used for efficacy testing of immunotherapy and for basic clinical research.


Assuntos
Antígenos de Dermatophagoides/imunologia , Imunização , Pyroglyphidae/imunologia , Adulto , Animais , Antígenos de Dermatophagoides/administração & dosagem , Antígenos de Dermatophagoides/efeitos adversos , Dessensibilização Imunológica , Expiração , Feminino , Humanos , Imunização/métodos , Imunoglobulina E/imunologia , Masculino , Pessoa de Meia-Idade , Mucosa Nasal/imunologia , Mucosa Nasal/metabolismo , Óxido Nítrico/metabolismo , Testes de Função Respiratória , Rinite Alérgica/diagnóstico , Rinite Alérgica/imunologia , Rinite Alérgica/terapia , Fatores de Risco , Adulto Jovem
6.
Allergy ; 70(10): 1288-99, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26011647

RESUMO

BACKGROUND: Genomewide association studies identified ORMDL3 as a plausible asthma candidate gene. ORMDL proteins regulate sphingolipid metabolism and ceramide homeostasis and participate in lymphocyte activation and eosinophil recruitment. Strong sequence homology between the three ORMDL genes and ORMDL protein conservation among different species suggest that they may have shared functions. We hypothesized that if single nucleotide polymorphisms (SNPs) in ORMDL3 alter its gene expression and play a role in asthma, variants in ORMDL1 and ORMDL2 might also be associated with asthma. METHODS: Asthma associations of 44 genotyped SNPs were determined in at least 1303 subjects (651 asthmatics). ORMDL expression was evaluated in peripheral blood mononuclear cells (PBMC) from 55 subjects (eight asthmatics) before and after allergen stimulation, and in blood (n = 60, 5 asthmatics). Allele-specific cis-effects on ORMDL expression were assessed. Interactions between human ORMDL proteins were determined in living cells. RESULTS: Sixteen SNPs in all three ORMDLs were associated with asthma (14 in ORMDL3). Baseline expression of ORMDL1 (P = 1.7 × 10(-6) ) and ORMDL2 (P = 4.9 × 10(-5) ) was significantly higher in PBMC from asthmatics, while induction of ORMDLs upon stimulation was stronger in nonasthmatics. Disease-associated alleles (rs8079416, rs4795405, rs3902920) alter ORMDL3 expression. ORMDL proteins formed homo- and heterooligomers and displayed similar patterns of interaction with SERCA2 and SPT1. CONCLUSIONS: Polymorphisms in ORMDL genes are associated with asthma. Asthmatics exhibit increased ORMDL levels, suggesting that ORMDLs contribute to asthma. Formation of heterooligomers and similar interaction patterns with proteins involved in calcium homeostasis and sphingolipid metabolism could indicate shared biological roles of ORMDLs, influencing airway remodeling and hyperresponsiveness.


Assuntos
Asma/genética , Regulação da Expressão Gênica , Estudos de Associação Genética , Predisposição Genética para Doença , Proteínas de Membrana/genética , Mutação , Fatores Etários , Alelos , Asma/imunologia , Asma/metabolismo , Estudos de Casos e Controles , Mapeamento Cromossômico , Epistasia Genética , Feminino , Genótipo , Humanos , Desequilíbrio de Ligação , Masculino , Proteínas de Membrana/metabolismo , Família Multigênica , Razão de Chances , Polimorfismo de Nucleotídeo Único , Ligação Proteica
7.
Pulm Pharmacol Ther ; 35: 50-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26545873

RESUMO

Segmental endotoxin challenge with lipopolysaccharide (LPS) can be used as a pharmacodynamic model to safely induce a transient airway inflammation in the peripheral lung of healthy subjects and to test the anti-inflammatory efficacy of investigational new drugs. In contrast to whole lung LPS challenge only a fraction of the dose is required that can be precisely administered to a specific lung region and a vehicle challenged segment as an intra-subject control can be included. The aim of this study was to assess the intra- and inter-individual variability of the response to segmental LPS challenge for the appropriate design and power calculation of future clinical trials. Two cohorts with 10 subjects each underwent two segmental LPS challenges within five weeks. The inflammatory response was evaluated in bronchoalveolar lavage (BAL) fluid at 6 (cohort 1) and 24 h (cohort 2) both in the LPS and in a vehicle challenged segment, as well as in plasma for up to 26 h post LPS challenge. While the cytokine response was more pronounced at 6 h, the influx of neutrophils and monocytes dominated at 24 h; e.g. neutrophils increased from a median (inter-quartile range, IQR) of 0.14 (0.16) and 0.09 (0.08)x10(4) cells/mL BAL fluid at baseline to 10.2 (17.1) and 19.3 (15.9)x10(4) cells/mL 24 h after the two separate challenges. The within-subject variability was higher than the between-subject variability for most of the markers. However, sample size estimations based on the variability of outcome variables found lower or equal numbers with cross-over designs compared to parallel group designs for cellular markers at 24 h and cytokine variables at 6 h. The segmental LPS challenge model was safe. Future study designs have to balance between burden to the study subjects (4 versus 2 bronchoscopies), variability (within-versus between-subject), and the desired outcome variable (cells versus chemo/cytokine).


Assuntos
Endotoxinas/toxicidade , Lipopolissacarídeos/toxicidade , Pneumonia/induzido quimicamente , Pneumonia/patologia , Adulto , Biomarcadores/sangue , Líquido da Lavagem Broncoalveolar , Broncoscopia , Quimiocinas/sangue , Estudos de Coortes , Citocinas/sangue , Feminino , Voluntários Saudáveis , Humanos , Masculino , Monócitos/efeitos dos fármacos , Neutrófilos/efeitos dos fármacos , Reprodutibilidade dos Testes , Testes de Função Respiratória
8.
Int J Clin Pract ; 69(1): 72-80, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25496316

RESUMO

BACKGROUND: Tiotropium is generally well tolerated; however, there has been debate whether antimuscarinics, particularly tiotropium administered via Respimat(®) Soft Mist(™) Inhaler, may induce cardiac arrhythmias in a vulnerable subpopulation with cardiovascular comorbidity. The aim of this study was to provide evidence of the cardiac safety of tiotropium maintenance therapy. METHODS: Combined analysis of Holter electrocardiogram (ECG) data from clinical trials of tiotropium in chronic obstructive pulmonary disease (COPD). Trials in the Boehringer Ingelheim clinical trials database conducted between 2003 and 2012, involving tiotropium HandiHaler(®) 18 µg and/or tiotropium Respimat(®) (1.25-, 2.5-, 5.0- and 10-µg doses) were reviewed. All trials involving Holter-ECG monitoring during this period were included in the analysis. Men and women aged ≥ 40 years with a smoking history of ≥ 10 pack-years, and a clinical diagnosis of COPD were included. Holter ECGs were evaluated for heart rate (HR), supraventricular premature beats (SVPBs), ventricular premature beats (VPBs) and pauses. Quantitative and categorical end-points were derived for each of the Holter monitoring days. RESULTS: Four trials (n = 727) were included in the analysis. Respimat(®) (1.25-10 µg) or HandiHaler(®) (18 µg) was not associated with changes in HR, SVPBs, VPBs and pauses compared with placebo or the pretreatment baseline period. In terms of cardiac arrhythmia end-points, there was no evidence for an exposure-effect relationship. CONCLUSIONS: In this analysis, tiotropium maintenance therapy administered using Respimat(®) (1.25-10 µg) or HandiHaler(®) (18 µg) once daily for periods of up to 48 weeks was well tolerated with no increased risk of cardiac arrhythmia in patients with COPD.


Assuntos
Coração/efeitos dos fármacos , Segurança do Paciente , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Ensaios Clínicos Controlados Aleatórios como Assunto , Brometo de Tiotrópio/efeitos adversos , Adulto , Idoso , Eletrocardiografia/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Antagonistas Muscarínicos/efeitos adversos , Brometo de Tiotrópio/farmacologia , Brometo de Tiotrópio/uso terapêutico
9.
Nat Commun ; 14(1): 5000, 2023 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-37591992

RESUMO

Single Pulse All Optical Switching represents the ability to reverse the magnetization of a nanostructure using a femtosecond single laser pulse without any applied field. Since the first switching experiments carried out on GdFeCo ferrimagnets, this phenomena has been only recently extended to a few other materials, MnRuGa alloys and Tb/Co multilayers with a very specific range of thickness and composition. Here, we demonstrate that single pulse switching can be obtained for a large range of rare earth-transition metal multilayers, making this phenomenon much more general. Surprisingly, the threshold fluence for switching is observed to be independent of the laser pulse duration. Moreover, at high laser intensities, concentric ring domain structures are induced. These striking features contrast to those observed in Gd based materials pointing towards a different reversal mechanism. Concomitant with the demonstration of an in-plane magnetization reorientation, a precessional reversal mechanism explains all the observed features.

10.
J Breath Res ; 18(1)2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37604132

RESUMO

Exhaled breath contains numerous volatile organic compounds (VOCs) known to be related to lung disease like asthma. Its collection is non-invasive, simple to perform and therefore an attractive method for the use even in young children. We analysed breath in children of the multicenter All Age Asthma Cohort (ALLIANCE) to evaluate if 'breathomics' have the potential to phenotype patients with asthma and wheeze, and to identify extrinsic risk factors for underlying disease mechanisms. A breath sample was collected from 142 children (asthma: 51, pre-school wheezers: 55, healthy controls: 36) and analysed using gas chromatography-mass spectrometry (GC/MS). Children were diagnosed according to Global Initiative for Asthma guidelines and comprehensively examined each year over up to seven years. Forty children repeated the breath collection after 24 or 48 months. Most breath VOCs differing between groups reflect the exposome of the children. We observed lower levels of lifestyle-related VOCs and higher levels of the environmental pollutants, especially naphthalene, in children with asthma or wheeze. Naphthalene was also higher in symptomatic patients and in wheezers with recent inhaled corticosteroid use. No relationships with lung function or TH2 inflammation were detected. Increased levels of naphthalene in asthmatics and wheezers and the relationship to disease severity could indicate a role of environmental or indoor air pollution for the development or progress of asthma. Breath VOCs might help to elucidate the role of the exposome for the development of asthma. The study was registered at ClinicalTrials.gov (NCT02496468).

11.
Rev Med Suisse ; 8(323): 51-6, 2012 Jan 11.
Artigo em Francês | MEDLINE | ID: mdl-22303741

RESUMO

Several preliminary studies suggest that prophylactic administration of probiotics reduces the incidence of necrotizing enterocolitis (NEC) in preterm infants, and several neonatology units have introduced this treatment under strict surveillance. Nonetheless, breast milk feeding remains the mainstay of NEC prevention. The beta-blocker propranolol, known for its effectiveness on cutaneous hemangiomas, is also proving useful for the treatment of subglottic or visceral hemangiomas. Following the decrease in severe bacterial infections thanks to widespread vaccinations, the McCarthy clinical score has regained importance in the prediction of the risk of bacterial infection in febrile infants. It is easy to use, economical, and has a diagnostic value comparable to laboratory tests. The new WHO growth charts have been introduced in Switzerland in 2011 to take into account the increasing regional and ethnic variations in our country. Any significant change in growth velocity should prompt an evaluation of the need of further investigations.


Assuntos
Agonistas Adrenérgicos beta/uso terapêutico , Doenças do Prematuro/prevenção & controle , Neoplasias/tratamento farmacológico , Probióticos/uso terapêutico , Infecções Bacterianas/complicações , Infecções Bacterianas/diagnóstico , Aleitamento Materno , Enterocolite Necrosante/prevenção & controle , Febre/microbiologia , Gráficos de Crescimento , Hemangioma/tratamento farmacológico , Humanos , Lactente , Recém-Nascido , Neoplasias Laríngeas/tratamento farmacológico , Neoplasias do Mediastino/tratamento farmacológico , Pediatria/tendências , Propranolol/uso terapêutico , Fatores de Risco , Neoplasias Cutâneas/tratamento farmacológico , Suíça , Resultado do Tratamento , Organização Mundial da Saúde
12.
Pneumologie ; 65(8): 465-70, 2011 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-21437859

RESUMO

BACKGROUND: Volatile organic compounds (VOCs) can be used as biomarkers in exhaled air. VOC profiles can be detected by an array of nanosensors of an electronic nose. These profiles can be analysed using bioinformatics. It is, however, not known whether different devices of the same model measure identically and to which extent different set-ups and the humidity of the inhaled air influence the VOC profile. METHODS: Three different measuring set-ups were designed and three healthy control subjects were measured with each of them, using four devices of the same model (Cyranose 320™, Smiths Detection). The exhaled air was collected in a plastic bag. Either ambient air was used as reference (set-up Leipzig), or the reference air was humidified (100% relative humidity) (set-up Marburg and set-up Munich). In the set-up Marburg the subjects inhaled standardised medical air (Aer medicinalis Linde, AGA AB) out of a compressed air bottle through a demand valve; this air (after humidification) was also used as reference. In the set-up Leipzig the subjects inhaled VOC-filtered ambient air, in the set-up Munich unfiltered room air. The data were evaluated using either the real-time data or the changes in resistance as calculated by the device. RESULTS: The results were clearly dependent on the set-up. Apparently, humidification of the reference air could reduce the variance between devices, but this result was also dependent on the evaluation method used. When comparing the three subjects, the set-ups Munich and Marburg mapped these in a similar way, whereas not only the signals but also the variance of the set-up Leipzig were larger. CONCLUSION: Measuring VOCs with an electronic nose has not yet been standardised and the set-up significantly affects the results. As other researchers use further methods, it is currently not possible to draw generally accepted conclusions. More systematic tests are required to find the most sensitive and reliable but still feasible set-up so that comparability is improved.


Assuntos
Poluentes Ocupacionais do Ar/análise , Técnicas Biossensoriais/instrumentação , Testes Respiratórios/instrumentação , Compostos Orgânicos Voláteis/análise , Adulto , Gráficos por Computador , Desenho de Equipamento , Feminino , Humanos , Umidade , Masculino , Microcomputadores , Pessoa de Meia-Idade , Sensibilidade e Especificidade
13.
Pneumologie ; 65(7): 401-5, 2011 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-21412705

RESUMO

Non-invasive pulmonary diagnostics is a promising and interesting field in respiratory medicine. Beside exhaled breath condensate, there is an increasing interest in alternative and faster techniques such as electronic noses (EN). EN aim to mimic or improve the sense of smelling. Different types of EN have been employed in research so far. In addition to ion mobility spectrometry and mass spectrometry, ENs that consist of various biopolymer sensors for the sensing of volatile organic compounds (VOCs) have been tested. VOCs bind to the sensors depending on size, structure, hydrogen binding and polarity. This leads to physical alterations, e. g., swelling resulting in a change of resistance. The smell print represents composite patterns in contrast to single compounds, and the distinction between different categories is achieved by pattern recognition algorithms. Other types of EN like mass spectrometry and ion mobility spectrometry are capable of identifying even single analyte fractions provided that their characteristics have been saved in data repositories. The non-invasive nature, onsite availability and relatively cheap sampling are advantages of ENs that underly the increasing interest in their use for medical purposes. Some promising results have already been published. This review aims to describe the state of the art in brief form.


Assuntos
Materiais Biomiméticos , Técnicas Biossensoriais , Testes Respiratórios/instrumentação , Gases/análise , Pneumopatias/diagnóstico , Olfato , Compostos Orgânicos Voláteis/análise , Biomarcadores/análise , Humanos , Pneumopatias/metabolismo
14.
Clin Exp Allergy ; 40(7): 998-1006, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20412138

RESUMO

BACKGROUND: Efficacy testing of drugs in seasonal allergic rhinitis (SAR) is often disturbed by seasonal variations of environmental allergens, and assessment of onset and duration of action is hardly possible under natural conditions. Allergen provocation in an environmental challenge chamber (ECC) can be of added value in this respect. However, the specificity, sensitivity, and reproducibility of outcome measures under both settings are unclear. OBJECTIVE: The aim of this study was to investigate and compare the diagnostic value (specificity, sensitivity, and reproducibility) of clinical end-points and biomarkers both following allergen provocation in an ECC and under natural conditions. METHODS: Sixty adult patients with SAR to grass and 60 healthy subjects were exposed twice to grass pollen in an ECC and observed twice during the pollen season. Symptoms, nasal flow, as well as exhaled and nasal nitric oxide (NO) were investigated. RESULTS: The total nasal symptom score (TNSS) in the ECC had the best reproducibility (intraclass correlation coefficient ICC=0.86) and sensitivity/specificity [area under receiver operating characteristic curve (AUC)=0.99] of all measures. Symptoms in season also had good sensitivity/specificity but were far less reproducible. Nasal flow in the ECC had good sensitivity/specificity but reproducibility was limited. NO measurements showed good reproducibility but sensitivity/specificity were limited, except for exhaled NO in season (AUC=0.75). CONCLUSION: The high reproducibility and sensitivity/specificity in the ECC suggests that TNSS is a valuable outcome measure. While exhaled NO can be considered to monitor airway inflammation, nasal NO appears to be unspecific.


Assuntos
Biomarcadores/análise , Óxido Nítrico/análise , Poaceae/imunologia , Pólen/imunologia , Rinite Alérgica Sazonal/diagnóstico , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Toxicol Appl Pharmacol ; 246(3): 107-15, 2010 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-20434477

RESUMO

Prediction of lung innate immune responses is critical for developing new drugs. Well-established immune modulators like lipopolysaccharides (LPS) can elicit a wide range of immunological effects. They are involved in acute lung diseases such as infections or chronic airway diseases such as COPD. LPS has a strong adjuvant activity, but its pyrogenicity has precluded therapeutic use. The bacterial lipopeptide MALP-2 and its synthetic derivative BPPcysMPEG are better tolerated. We have compared the effects of LPS and BPPcysMPEG on the innate immune response in human precision-cut lung slices. Cytokine responses were quantified by ELISA, Luminex, and Meso Scale Discovery technology. The initial response to LPS and BPPcysMPEG was marked by coordinated and significant release of the mediators IL-1ß, MIP-1ß, and IL-10 in viable PCLS. Stimulation of lung tissue with BPPcysMPEG, however, induced a differential response. While LPS upregulated IFN-γ, BPPcysMPEG did not. This traces back to their signaling pathways via TLR4 and TLR2/6. The calculated exposure doses selected for LPS covered ranges occurring in clinical studies with human beings. Correlation of obtained data with data from human BAL fluid after segmental provocation with endotoxin showed highly comparable effects, resulting in a coefficient of correlation >0.9. Furthermore, we were interested in modulating the response to LPS. Using dexamethasone as an immunosuppressive drug for anti-inflammatory therapy, we found a significant reduction of GM-CSF, IL-1ß, and IFN-γ. The PCLS-model offers the unique opportunity to test the efficacy and toxicity of biological agents intended for use by inhalation in a complex setting in humans.


Assuntos
Citocinas/imunologia , Imunidade Inata/imunologia , Fatores Imunológicos/imunologia , Pulmão/imunologia , Adulto , Anti-Inflamatórios/imunologia , Quimiocina CCL4/imunologia , Feminino , Fator Estimulador de Colônias de Granulócitos e Macrófagos/imunologia , Humanos , Interferon gama/imunologia , Interleucina-10/imunologia , Interleucina-1beta/imunologia , Lipopeptídeos/imunologia , Lipopolissacarídeos/imunologia , Masculino , Polietilenoglicóis , Receptores Toll-Like/imunologia
16.
Int J Clin Pharmacol Ther ; 47(2): 71-7, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19203562

RESUMO

UNLABELLED: Antihistamines and nasal decongestants are well-established therapeutics in allergic rhinitis. However, no data are available which directly compare the effect size of the single substances with their combination in a single study including placebo (PLA) treatment. OBJECTIVE: The aim of this study was to evaluate the effect of a combination of cetirizine (CET) and pseudoephedrine (PSE) and to compare it to treatment with CET or PSE alone and to PLA during grass pollen allergen challenge in an environmental challenge chamber (ECC). MATERIAL AND METHODS: In a randomized, double-blind, placebo-controlled, four-way crossover study the effect of a combination of 10 mg CET with 120 mg PSE (CET + PSE) versus CET or PSE alone or PLA on symptoms, nasal flow, and nasal secretions was investigated in 49 patients with intermittent allergic rhinitis. Subjects underwent four 6-h pollen exposures in an ECC with administration of the drugs after 2 h. RESULTS: The induction of nasal symptoms, nasal secretion and nasal obstruction (measured as nasal flow) during the first 2 h of pollen exposure was highly reproducible at the 4 consecutive exposures. The symptom of nasal obstruction was significantly reduced after treatment with CET + PSE compared to the treatment with CET or PSE alone or PLA (p < 0.0001). Furthermore, the combination treatment significantly reduced the total nasal symptom score (TNSS) and visual analogue scale score (VAS) compared to the single treatments or PLA. Nasal flow was significantly increased after treatment with CET + PSE and PSE and nasal secretions were significantly reduced by CET + PSE and CET without significant additional improvement of the combination therapy. CONCLUSION: The combination treatment with CET and PSE is more effective than treatment with single substances in subjects with allergic rhinitis.


Assuntos
Cetirizina/uso terapêutico , Antagonistas não Sedativos dos Receptores H1 da Histamina/uso terapêutico , Pseudoefedrina/uso terapêutico , Rinite Alérgica Sazonal/tratamento farmacológico , Adulto , Cetirizina/administração & dosagem , Estudos Cross-Over , Método Duplo-Cego , Combinação de Medicamentos , Sinergismo Farmacológico , Feminino , Antagonistas não Sedativos dos Receptores H1 da Histamina/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Descongestionantes Nasais/administração & dosagem , Descongestionantes Nasais/uso terapêutico , Obstrução Nasal/tratamento farmacológico , Obstrução Nasal/etiologia , Pólen/imunologia , Pseudoefedrina/administração & dosagem , Rinite Alérgica Sazonal/imunologia , Adulto Jovem
17.
Rev Med Suisse ; 5(191): 402-4, 406-8, 2009 Feb 18.
Artigo em Francês | MEDLINE | ID: mdl-19331096

RESUMO

A cleft can be labial, labial-maxillary, unilateral or bilateral labial-maxillary-palatal, or isolated palatal. A multidisciplinary team includes several specialists who will handle the diverse problems of children born with a cleft. This team will follow the child through each developmental stage and assemble an optimal treatment plan, thus reducing the onus on the family. Depending on the type of cleft and the age of the child, feeding, speech, ORL, dental, orthodontic, esthetic and possibly also psychological problems will be taken care of. This is why cleft treatment starts at the time it is diagnosed, before or after birth, and ends when the child is fully grown. It requires a complete interdisciplinary team and the collaboration with obstetricians and geneticians.


Assuntos
Fenda Labial/cirurgia , Fissura Palatina/cirurgia , Adolescente , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Procedimentos Cirúrgicos Otorrinolaringológicos , Equipe de Assistência ao Paciente , Procedimentos de Cirurgia Plástica , Adulto Jovem
18.
Eur Respir J ; 31(1): 21-8, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17928308

RESUMO

Primary graft dysfunction, characterised by intra-alveolar oedema, is a major obstacle in pulmonary transplantation. The present study evaluates the potential of keratinocyte growth factor (palmiferin; DeltaN23-KGF) for the prevention of oedema in lung transplants. Intratracheal instillation of 5 mg x kg(-1) DeltaN23-KGF was performed in Lewis rats on days 3 and 2 before explantation. Control animals obtained an equivalent volume of vehicle. Left lungs were isogeneically transplanted and the graft recipients were sacrificed 1 day later for stereological analysis of intra-alveolar oedema and bronchoalveolar lavage. The total protein and phospholipid content, as well as surfactant proteins, were measured. Surfactant activity was analysed with a pulsating bubble surfactometer. In grafts from control treated donors, the fraction of intra-alveolar oedema amounted to 3.4+/-1.1% of the total parenchymal volume. Treatment of donor lungs with DeltaN23-KGF reduced oedema to a fraction of 1.6+/-0.8%. In the lavage fluid of pulmonary grafts from DeltaN23-KGF-treated donors, the total protein content was decreased compared with vehicle-treated lung transplants, whereas phospholipids did not differ. The protein fraction contained increased amounts of surfactant protein-C after DeltaN23-KGF treatment and surfactant function was improved. Treatment of donor lungs with palifermin protects against intra-alveolar oedema formation upon transplantation. This effect appears to be mediated by an improved surfactant homeostasis.


Assuntos
Edema/patologia , Fator 7 de Crescimento de Fibroblastos/metabolismo , Transplante de Pulmão/métodos , Pulmão/patologia , Animais , Lavagem Broncoalveolar , Líquido da Lavagem Broncoalveolar , Edema/prevenção & controle , Homeostase , Pulmão/metabolismo , Masculino , Modelos Biológicos , Peptídeos/química , Fosfolipídeos/química , Alvéolos Pulmonares/metabolismo , Ratos , Ratos Endogâmicos Lew
19.
J Breath Res ; 12(3): 036023, 2018 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-29771243

RESUMO

INTRODUCTION: Chronic lung allograft dysfunction with its clinical correlative of bronchiolitis obliterans syndrome (BOS) remains the major limiting factor for long-term graft survival. Currently there are no established methods for the early diagnosis or prediction of BOS. To assess the feasibility of breath collection as a non-invasive tool and the potential of breath volatile organic compounds (VOC) for the early detection of BOS, we compared the breath VOC composition between transplant patients without and different stages of BOS. METHODS: 75 outpatients (25 BOS stage 0, 25 BOS stage 1 + 2, 25 BOS stage 3) after bilateral lung transplantation were included. Exclusion criteria were active smoking, oxygen therapy and acute infection. Patients inhaled room air through a VOC and sterile filter and exhaled into an aluminum reservoir tube. Breath was loaded directly onto Tenax® TA adsorption tubes and was subsequently analyzed by gas-chromatography/mass-spectrometry. RESULTS: The three groups were age and gender matched, but differed with respect to time since transplantation, the spectrum of underlying disease, and treatment regimes. Relative to patients without BOS, BOS stage 3 patients showed a larger number of different VOCs, and more pronounced differences in the level of VOCs as compared to BOS stage 1 + 2 patients. Logistic regression analysis found no differences between controls and BOS 1 + 2, but four VOCs (heptane, isopropyl-myristate, ethyl-acetate, ionone) with a significant contribution to the discrimination between controls and BOS stage 3. A combination of these four VOCs separated these groups with an area under the curve of 0.87. CONCLUSION: Breath sample collection using our reservoir sampler in the clinical environment was feasible. Our results suggest that breath VOCs can discriminate severe BOS. However, convincing evidence for VOCs with a potential to detect early onset BOS is lacking.


Assuntos
Aloenxertos/fisiopatologia , Testes Respiratórios/métodos , Transplante de Pulmão , Transplantados , Compostos Orgânicos Voláteis/análise , Fatores de Confusão Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Fumar/efeitos adversos
20.
Respir Res ; 7: 32, 2006 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-16504044

RESUMO

BACKGROUND: The loss of alveolar walls is a hallmark of emphysema. As fibroblasts play an important role in the maintenance of alveolar structure, a change in fibroblast phenotype could be involved in the pathogenesis of this disease. In a previous study we found a reduced in vitro proliferation rate and number of population doublings of parenchymal lung fibroblasts from patients with emphysema and we hypothesized that these findings could be related to a premature cellular aging of these cells. In this study, we therefore compared cellular senescence markers and expression of respective genes between lung fibroblasts from patients with emphysema and control patients without COPD. METHODS: Primary lung fibroblasts were obtained from 13 patients with moderate to severe lung emphysema (E) and 15 controls (C) undergoing surgery for lung tumor resection or volume reduction (n = 2). Fibroblasts (8E/9C) were stained for senescence-associated beta-galactosidase (SA-beta-Gal). In independent cultures, DNA from lung fibroblasts (7E/8C) was assessed for mean telomere length. Two exploratory 12 k cDNA microarrays were used to assess gene expression in pooled fibroblasts (3E/3C). Subsequently, expression of selected genes was evaluated by quantitative PCR (qPCR) in fibroblasts of individual patients (10E/9C) and protein concentration was analyzed in the cell culture supernatant. RESULTS: The median (quartiles) percentage of fibroblasts positive for SA-beta-Gal was 4.4 (3.2;4.7) % in controls and 16.0 (10.0;24.8) % in emphysema (p = 0.001), while telomere length was not different. Among the candidates for differentially expressed genes in the array (factor > or = 3), 15 were upregulated and 121 downregulated in emphysema. qPCR confirmed the upregulation of insulin-like growth factor-binding protein (IGFBP)-3 and IGFBP-rP1 (p = 0.029, p = 0.0002), while expression of IGFBP-5, -rP2 (CTGF), -rP4 (Cyr61), FOSL1, LOXL2, OAZ1 and CDK4 was not different between groups. In line with the gene expression we found increased cell culture supernatant concentrations of IGFBP-3 (p = 0.006) in emphysema. CONCLUSION: These data support the hypothesis that premature aging of lung fibroblasts occurs in emphysema, via a telomere-independent mechanism. The upregulation of the senescence-associated IGFBP-3 and -rP1 in emphysema suggests that inhibition of the action of insulin and insulin-like growth factors could be involved in the reduced in vitro-proliferation rate.


Assuntos
Senescência Celular , Enfisema/patologia , Fibroblastos/patologia , Pulmão/patologia , Biomarcadores , Enfisema/genética , Enfisema/fisiopatologia , Enfisema/cirurgia , Regulação da Expressão Gênica , Humanos , Técnicas In Vitro , Pulmão/citologia , Pulmão/fisiologia , Pulmão/fisiopatologia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Reação em Cadeia da Polimerase , Alvéolos Pulmonares/patologia , Valores de Referência , Testes de Função Respiratória , Telômero/patologia , Telômero/ultraestrutura , beta-Galactosidase/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA