Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Mol Diagn ; 24(4): 320-336, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35121140

RESUMO

Previous studies have described reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for the rapid detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in nasopharyngeal/oropharyngeal swab and saliva samples. This multisite clinical evaluation describes the validation of an improved sample preparation method for extraction-free RT-LAMP and reports clinical performance of four RT-LAMP assay formats for SARS-CoV-2 detection. Direct RT-LAMP was performed on 559 swabs and 86,760 saliva samples and RNA RT-LAMP on extracted RNA from 12,619 swabs and 12,521 saliva samples from asymptomatic and symptomatic individuals across health care and community settings. For direct RT-LAMP, overall diagnostic sensitivity (DSe) was 70.35% (95% CI, 63.48%-76.60%) on swabs and 84.62% (95% CI, 79.50%-88.88%) on saliva, with diagnostic specificity of 100% (95% CI, 98.98%-100.00%) on swabs and 100% (95% CI, 99.72%-100.00%) on saliva, compared with quantitative RT-PCR (RT-qPCR); analyzing samples with RT-qPCR ORF1ab CT values of ≤25 and ≤33, DSe values were 100% (95% CI, 96.34%-100%) and 77.78% (95% CI, 70.99%-83.62%) for swabs, and 99.01% (95% CI, 94.61%-99.97%) and 87.61% (95% CI, 82.69%-91.54%) for saliva, respectively. For RNA RT-LAMP, overall DSe and diagnostic specificity were 96.06% (95% CI, 92.88%-98.12%) and 99.99% (95% CI, 99.95%-100%) for swabs, and 80.65% (95% CI, 73.54%-86.54%) and 99.99% (95% CI, 99.95%-100%) for saliva, respectively. These findings demonstrate that RT-LAMP is applicable to a variety of use cases, including frequent, interval-based direct RT-LAMP of saliva from asymptomatic individuals who may otherwise be missed using symptomatic testing alone.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/análise , RNA Viral/genética , SARS-CoV-2/genética , Saliva , Sensibilidade e Especificidade
2.
Viruses ; 13(11)2021 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-34834993

RESUMO

Epizootic haemorragic disease (EHD) is an important disease of white-tailed deer and can cause a bluetongue-like illness in cattle. A definitive diagnosis of EHD relies on molecular assays such as real-time RT-qPCR or conventional PCR. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a cost-effective, specific, and sensitive technique that provides an alternative to RT-qPCR. We designed two sets of specific primers targeting segment-9 of the EHD virus genome to enable the detection of western and eastern topotypes, and evaluated their performance in singleplex and multiplex formats using cell culture isolates (n = 43), field specimens (n = 20), and a proficiency panel (n = 10). The limit of detection of the eastern and western RT-LAMP assays was estimated as ~24.36 CT and as ~29.37 CT in relation to real-time RT-qPCR, respectively, indicating a greater sensitivity of the western topotype singleplex RT-LAMP. The sensitivity of the western topotype RT-LAMP assay, relative to the RT-qPCR assay, was 72.2%, indicating that it could be theoretically used to detect viraemic cervines and bovines. For the first time, an RT-LAMP assay was developed for the rapid detection of the EHD virus that could be used as either a field test or high throughput screening tool in established laboratories to control the spread of EHD.


Assuntos
Vírus da Doença Hemorrágica Epizoótica/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Infecções por Reoviridae/diagnóstico , Infecções por Reoviridae/virologia , Animais , Bluetongue/virologia , Bovinos , Primers do DNA/genética , Cervos , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real , Transcrição Reversa , Sensibilidade e Especificidade
3.
J Virol Methods ; 289: 114048, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33358911

RESUMO

We describe the optimisation of a simplified sample preparation method which permits rapid and direct detection of SARS-CoV-2 RNA within saliva, using reverse-transcription loop-mediated isothermal amplification (RT-LAMP). Treatment of saliva samples prior to RT-LAMP by dilution 1:1 in Mucolyse™, followed by dilution in 10 % (w/v) Chelex© 100 Resin and a 98 °C heat step for 2 min enabled detection of SARS-CoV-2 RNA in positive saliva samples. Using RT-LAMP, SARS-CoV-2 RNA was detected in as little as 05:43 min, with no amplification detected in 3097 real-time reverse transcription PCR (rRT-PCR) negative saliva samples from staff tested within a service evaluation study, or for other respiratory pathogens tested (n = 22). Saliva samples can be collected non-invasively, without the need for skilled staff and can be obtained from both healthcare and home settings. Critically, this approach overcomes the requirement for, and validation of, different swabs and the global bottleneck in obtaining access to extraction robots and reagents to enable molecular testing by rRT-PCR. Such testing opens the possibility of public health approaches for effective intervention during the COVID-19 pandemic through regular SARS-CoV-2 testing at a population scale, combined with isolation and contact tracing.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , SARS-CoV-2/isolamento & purificação , Saliva/virologia , Manejo de Espécimes/métodos , Humanos , RNA Viral/análise
4.
J Infect ; 82(1): 117-125, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33271166

RESUMO

The COVID-19 pandemic has illustrated the importance of simple, rapid and accurate diagnostic testing. This study describes the validation of a new rapid SARS-CoV-2 RT-LAMP assay for use on extracted RNA or directly from swab offering an alternative diagnostic pathway that does not rely on traditional reagents that are often in short supply during a pandemic. Analytical specificity (ASp) of this new RT-LAMP assay was 100% and analytical sensitivity (ASe) was between 1 × 101 and 1 × 102 copies per reaction when using a synthetic DNA target. The overall diagnostic sensitivity (DSe) and specificity (DSp) of RNA RT-LAMP was 97% and 99% respectively, relative to the standard of care rRT-PCR. When a CT cut-off of 33 was employed, above which increasingly evidence suggests there is a low risk of patients shedding infectious virus, the diagnostic sensitivity was 100%. The DSe and DSp of Direct RT-LAMP (that does not require RNA extraction) was 67% and 97%, respectively. When setting CT cut-offs of ≤33 and ≤25, the DSe increased to 75% and 100%, respectively, time from swab-to-result, CT < 25, was < 15 min. We propose that RNA RT-LAMP could replace rRT-PCR where there is a need for increased sample throughput and Direct RT-LAMP as a near-patient screening tool to rapidly identify highly contagious individuals within emergency departments and care homes during times of increased disease prevalence ensuring negative results still get laboratory confirmation.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/análise , SARS-CoV-2/genética , Técnicas de Laboratório Clínico/métodos , Humanos , Programas de Rastreamento/métodos , Reação em Cadeia da Polimerase em Tempo Real , Saliva/virologia , Sensibilidade e Especificidade
5.
Clin Microbiol Infect ; 27(9): 1348.e1-1348.e7, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33901668

RESUMO

OBJECTIVES: Rapid, high throughput diagnostics are a valuable tool, allowing the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in populations so as to identify and isolate people with asymptomatic and symptomatic infections. Reagent shortages and restricted access to high throughput testing solutions have limited the effectiveness of conventional assays such as quantitative RT-PCR (RT-qPCR), particularly throughout the first months of the coronavirus disease 2019 pandemic. We investigated the use of LamPORE, where loop-mediated isothermal amplification (LAMP) is coupled to nanopore sequencing technology, for the detection of SARS-CoV-2 in symptomatic and asymptomatic populations. METHODS: In an asymptomatic prospective cohort, for 3 weeks in September 2020, health-care workers across four sites (Birmingham, Southampton, Basingstoke and Manchester) self-swabbed with nasopharyngeal swabs weekly and supplied a saliva specimen daily. These samples were tested for SARS-CoV-2 RNA using the Oxford Nanopore LamPORE system and a reference RT-qPCR assay on extracted sample RNA. A second retrospective cohort of 848 patients with influenza-like illness from March 2020 to June 2020 were similarly tested from nasopharyngeal swabs. RESULTS: In the asymptomatic cohort a total of 1200 participants supplied 23 427 samples (3966 swab, 19 461 saliva) over a 3-week period. The incidence of SARS-CoV-2 detection using LamPORE was 0.95%. Diagnostic sensitivity and specificity of LamPORE was >99.5% (decreasing to approximately 98% when clustered estimation was used) in both swab and saliva asymptomatic samples when compared with the reference RT-qPCR test. In the retrospective symptomatic cohort, the incidence was 13.4% and the sensitivity and specificity were 100%. CONCLUSIONS: LamPORE is a highly accurate methodology for the detection of SARS-CoV-2 in both symptomatic and asymptomatic population settings and can be used as an alternative to RT-qPCR.


Assuntos
COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Pandemias , SARS-CoV-2/isolamento & purificação , COVID-19/virologia , Estudos de Coortes , Proteínas do Nucleocapsídeo de Coronavírus/genética , Humanos , Limite de Detecção , Sequenciamento por Nanoporos , Nasofaringe/virologia , Poliproteínas/genética , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , SARS-CoV-2/genética , Saliva/virologia , Sensibilidade e Especificidade , Proteínas Virais/genética
6.
Pathogens ; 9(4)2020 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-32326039

RESUMO

Real-time PCR (rPCR) is a widely accepted diagnostic tool for the detection and quantification of nucleic acid targets. In order for these assays to achieve high sensitivity and specificity, primer and probe-template complementarity is essential; however, mismatches are often unavoidable and can result in false-negative results and errors in quantifying target sequences. Primer and probe sequences therefore require continual evaluation to ensure they remain fit for purpose. This paper describes the development of a linear model and associated computational tool (GoPrime) designed to predict the performance of rPCR primers and probes across multiple sequence data. Empirical data were generated using DNA oligonucleotides (n = 90) that systematically introduced variation in the primer and probe target regions of a diagnostic assay routinely used to detect foot-and-mouth disease virus (FMDV); an animal virus that exhibits a high degree of sequence variability. These assays revealed consistent impacts of patterns of substitutions in primer and probe-sites on rPCR cycle threshold (CT) and limit of detection (LOD). These data were used to populate GoPrime, which was subsequently used to predict rPCR results for DNA templates (n = 7) representing the natural sequence variability within FMDV. GoPrime was also applicable to other areas of the FMDV genome, with predictions for the likely targets of a FMDV-typing assay consistent with published experimental data. Although further work is required to improve these tools, including assessing the impact of primer-template mismatches in the reverse transcription step and the broader impact of mismatches for other assays, these data support the use of mathematical models for rapidly predicting the performance of rPCR primers and probes in silico.

7.
J Virol Methods ; 274: 113730, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31513860

RESUMO

Peste des petits ruminants (PPR) is a viral disease of small ruminants that is caused by the PPR virus (PPRV) and is a significant burden on subsistence farmers across the developing world. Loop-mediated isothermal amplification (LAMP) provides cost-effective, rapid, specific and sensitive detection of nucleic acid and has been demonstrated to have field application for a range of viruses. We describe the development of a novel PPRV RT-LAMP assay utilising carefully-selected primers (targeting the N-gene) allowing for the detection of all known PPRV lineages in < 20 min. The assay was evaluated in comparison with a "gold standard" real-time RT-PCR assay using more than 200 samples, comprising samples from recent PPRV outbreaks, experimentally-infected goats, well-characterised cell culture isolates and samples collected from uninfected animals. The RT-LAMP assay demonstrated 100% diagnostic specificity and greater than 97% diagnostic sensitivity in comparison with the real-time RT-PCR assay. The limit of detection was between 0.3 and 0.8 log10 TCID50 ml-1 equating to a CT value of 31.52 to 33.48. In experimentally-infected animals, the RT-LAMP could detect PPRV as early as 4 days post infection (dpi) - before clinical signs were observed at 7 dpi. The RT-LAMP assay can support the global PPR eradication campaign.


Assuntos
Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Peste dos Pequenos Ruminantes/diagnóstico , Vírus da Peste dos Pequenos Ruminantes/isolamento & purificação , Animais , Primers do DNA/genética , Doenças das Cabras/diagnóstico , Cabras , Vírus da Peste dos Pequenos Ruminantes/genética , Sensibilidade e Especificidade , Fatores de Tempo
8.
J Virol Methods ; 249: 102-110, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28837842

RESUMO

This study describes the first multiway comparison of portable isothermal assays for the detection of foot-and-mouth disease virus (FMDV), benchmarked against real-time reverse transcription RT-PCR (rRT-PCR). The selected isothermal chemistries included reverse transcription loop-mediated isothermal amplification (RT-LAMP) and reverse transcription recombinase polymerase amplification (RT-RPA). The analytical sensitivity of RT-LAMP was comparable to rRT-PCR (101 RNA copies), while RT-RPA was one log10 less sensitive (102 RNA copies). Diagnostic performance was evaluated using a panel of 35 samples from FMDV-positive cattle and eight samples from cattle infected with other vesicular viruses. Assay concordance for RT-LAMP and RT-RPA was 86-98% and 67-77%, respectively, when compared to rRT-PCR, with discordant samples consistently having high rRT-PCR cycle threshold values (no false-positives were detected for any assay). In addition, a hierarchy of sample preparation methods, from robotic extraction to simple dilution of samples, for epithelial suspensions, serum and oesophageal-pharyngeal (OP) fluid were evaluated. Results obtained for RT-LAMP confirmed that FMDV RNA can be detected in the absence of RNA extraction. However, simple sample preparation methods were less encouraging for RT-RPA, with accurate results only obtained when using RNA extraction. Although the evaluation of assay performance is specific to the conditions tested in this study, the compatibility of RT-LAMP chemistry with multiple sample types, both in the presence and absence of nucleic acid extraction, provides advantages over alternative isothermal chemistries and alternative pen-side diagnostics such as antigen-detection lateral-flow devices. These characteristics of RT-LAMP enable the assay to be performed over a large diagnostic detection window, providing a realistic means to rapidly confirm positive FMD cases close to the point of sampling.


Assuntos
Doenças dos Bovinos/diagnóstico , Vírus da Febre Aftosa/isolamento & purificação , Febre Aftosa/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Reação em Cadeia da Polimerase em Tempo Real , Animais , Bovinos , Doenças dos Bovinos/virologia , Primers do DNA/genética , Vírus da Febre Aftosa/genética , RNA Viral/genética , Sensibilidade e Especificidade , Temperatura
9.
Genome Announc ; 4(2)2016 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-27081129

RESUMO

We report nine full-genome sequences of vesicular stomatitis virus obtained by Illumina next-generation sequencing of RNA, isolated from either cattle epithelial suspensions or cell culture supernatants. Seven of these viral genomes belonged to the New Jersey serotype/species (clade III), while two isolates belonged to the Indiana serotype/species.

10.
J Virol Methods ; 234: 123-31, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27118518

RESUMO

Vesicular stomatitis (VS) is endemic in Central America and northern regions of South America, where sporadic outbreaks in cattle and pigs can cause clinical signs that are similar to foot-and-mouth disease (FMD). There is therefore a pressing need for rapid, sensitive and specific differential diagnostic assays that are suitable for decision making in the field. RT-LAMP assays have been developed for vesicular diseases such as FMD and swine vesicular disease (SVD) but there is currently no RT-LAMP assay that can detect VS virus (VSV), nor are there any multiplex RT-LAMP assays which permit rapid discrimination between these 'look-a-like' diseases in situ. This study describes the development of a novel RT-LAMP assay for the detection of VSV focusing on the New Jersey (VSNJ) serotype, which has caused most of the recent VS cases in the Americas. This RT-LAMP assay was combined in a multiplex format combining molecular lateral-flow devices for the discrimination between FMD and VS. This assay was able to detect representative VSNJV's and the limit of detection of the singleplex and multiplex VSNJV RT-LAMP assays were equivalent to laboratory based real-time RT-PCR assays. A similar multiplex RT-LAMP assay was developed to discriminate between FMDV and SVDV, showing that FMDV, SVDV and VSNJV could be reliably detected within epithelial suspensions without the need for prior RNA extraction, providing an approach that could be used as the basis for a rapid and low cost assay for differentiation of FMD from other vesicular diseases in the field.


Assuntos
Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Estomatite Vesicular/diagnóstico , Vírus da Estomatite Vesicular New Jersey/isolamento & purificação , Animais , Bovinos/virologia , Doenças dos Bovinos/diagnóstico , Doenças dos Bovinos/virologia , América Central , Febre Aftosa/virologia , RNA Viral/genética , Sensibilidade e Especificidade , América do Sul , Suínos/virologia , Doenças dos Suínos/diagnóstico , Doenças dos Suínos/virologia , Doença Vesicular Suína/virologia , Temperatura , Estomatite Vesicular/virologia , Vírus da Estomatite Vesicular New Jersey/classificação , Vírus da Estomatite Vesicular New Jersey/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA