Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Cell ; 179(6): 1409-1423.e17, 2019 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-31778655

RESUMO

The evolution of flight in feathered dinosaurs and early birds over millions of years required flight feathers whose architecture features hierarchical branches. While barb-based feather forms were investigated, feather shafts and vanes are understudied. Here, we take a multi-disciplinary approach to study their molecular control and bio-architectural organizations. In rachidial ridges, epidermal progenitors generate cortex and medullary keratinocytes, guided by Bmp and transforming growth factor ß (TGF-ß) signaling that convert rachides into adaptable bilayer composite beams. In barb ridges, epidermal progenitors generate cylindrical, plate-, or hooklet-shaped barbule cells that form fluffy branches or pennaceous vanes, mediated by asymmetric cell junction and keratin expression. Transcriptome analyses and functional studies show anterior-posterior Wnt2b signaling within the dermal papilla controls barbule cell fates with spatiotemporal collinearity. Quantitative bio-physical analyses of feathers from birds with different flight characteristics and feathers in Burmese amber reveal how multi-dimensional functionality can be achieved and may inspire future composite material designs. VIDEO ABSTRACT.


Assuntos
Adaptação Fisiológica , Plumas/anatomia & histologia , Plumas/fisiologia , Voo Animal/fisiologia , Animais , Evolução Biológica , Aves/anatomia & histologia , Moléculas de Adesão Celular/metabolismo , Citoesqueleto/metabolismo , Derme/anatomia & histologia , Células-Tronco/citologia , Fatores de Tempo , Transcriptoma/genética , Via de Sinalização Wnt/genética
2.
BMC Musculoskelet Disord ; 25(1): 350, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702748

RESUMO

BACKGROUND: Metacarpal shaft fracture is a common type of hand fracture. Numerous studies have explored fixing transverse fractures in the midshaft of the metacarpal bone. However, this section of the metacarpal bone is often susceptible to high-energy injury, resulting in comminuted fracture or bone loss. In such cases, wedge-shaped bone defects can develop in the metacarpal shaft, increasing the difficulty of performing fracture fixation. Notably, the research on this type of fracture fixation is limited. This study compared the abilities of four fixation methods to fix metacarpal shaft fractures with wedge-shaped bone defects. METHODS: In total, 28 artificial metacarpal bones were used. To create wedge-shaped bone defects, an electric saw was used to create metacarpal shaft fractures at the midshaft of each bone. The artificial metacarpal bones were then divided into four groups for fixation. The bones in the first group were fixed with a dorsal locked plate (DP group), those in the second group were fixed with a volar locked plate (VP group), and those in the third group were fixed by combining dorsal and volar locked plates (DP + VP group), and those in the fourth group were fixed with two K-wires (2 K group). Cantilever bending tests were conducted using a material testing machine to measure yielding force and stiffness. The four groups' fixation capabilities were then assessed through analysis of variance and Tukey's test. RESULTS: The DP + VP group (164.1±44.0 N) achieved a significantly higher yielding force relative to the 2 K group (50.7 ± 8.9 N); the DP group (13.6 ± 3.0 N) and VP group (12.3 ± 1.0 N) did not differ significantly in terms of yielding force, with both achieving lower yielding forces relative to the DP + VP group and 2 K group. The DP + VP group (19.8±6.3 N/mm) achieved the highest level of stiffness, and the other three groups did not differ significantly in terms of stiffness (2 K group, 5.4 ± 1.1 N/mm; DP group, 4.0 ± 0.9 N/mm; VP group, 3.9 ± 1.9 N/mm). CONCLUSIONS: The fixation method involving the combined use of dorsal and volar locked plates (DP + VP group) resulted in optimal outcomes with respect to fixing metacarpal shaft fractures with volar wedge bone defects.


Assuntos
Placas Ósseas , Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Ósseas , Ossos Metacarpais , Ossos Metacarpais/lesões , Ossos Metacarpais/cirurgia , Humanos , Fenômenos Biomecânicos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia
3.
BMC Oral Health ; 23(1): 324, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-37231447

RESUMO

OBJECTIVE: This study proposed a new classification method of bone quantity and quality at the dental implant site using cone-beam computed tomography (CBCT) image analysis, classifying cortical and cancellous bones separately and using CBCT for quantitative analysis. METHODS: Preoperative CBCT images were obtained from 128 implant patients (315 sites). First, measure the crestal cortical bone thickness (in mm) and the cancellous bone density [in grayscale values (GV) and bone mineral density (g/cm3)] at the implant sites. The new classification for bone quality at the implant site proposed in this study is a "nine-square division" bone classification system, where the cortical bone thickness is classified into A: > 1.1 mm, B:0.7-1.1 mm, and C: < 0.7 mm, and the cancellous bone density is classified into 1: > 600 GV (= 420 g/cm3), 2:300-600 GV (= 160 g/cm3-420 g/cm3), and 3: < 300 GV (= 160 g/cm3). RESULTS: The results of the nine bone type proportions based on the new jawbone classification were as follows: A1 (8.57%,27/315), A2 (13.02%), A3 (4.13%), B1 (17.78%), B2 (20.63%), B3 (8.57%) C1 (4.44%), C2 (14.29%), and C3 (8.57%). CONCLUSIONS: The proposed classification can complement the parts overlooked in previous bone classification methods (bone types A3 and C1). TRIAL REGISTRATION: The retrospective registration of this study was approved by the Institutional Review Board of China Medical University Hospital, No. CMUH 108-REC2-181.


Assuntos
Implantes Dentários , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Arcada Osseodentária , Tomografia Computadorizada de Feixe Cônico , Densidade Óssea
4.
Biomed Eng Online ; 21(1): 6, 2022 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-35090461

RESUMO

BACKGROUND: Menopause-induced decline in estrogen levels in women is a main factor leading to osteoporosis. The objective of this study was to investigate the effect of intermittent parathyroid hormone (PTH) on bone structural parameters of the femoral neck in ovariectomized rats, in addition to correlations of maximum fracture force. METHODS: Fifteen female Wister rats were divided into three groups: (1) control group; (2) ovariectomized (OVX) group; and (3) OVX + PTH group. All rats were then killed and the femurs extracted for microcomputed tomography scanning to measure volumetric bone mineral density (vBMD) and bone structural parameters of the femoral neck. Furthermore, the fracture forces of femoral neck were measured using a material testing system. RESULTS: Compared with the control and OVX + PTH groups, the OVX group had significantly lower aBMD, bone parameter, and mechanical strength values. A comparison between OVX and OVX + PTH groups indicated that PTH treatment increased several bone parameters. However, the OVX + PTH groups did not significantly differ with the control group with respect to the bone structural parameters, except for trabecular bone thickness of cancellous bone, which was greater. In addition, among the bone structural parameters, the CSA and BSI of cortical bone were significantly correlated with the maximum fracture force of the femoral neck, with correlations of, respectively, 0.682 (p = 0.005) and 0.700 (p = 0.004). CONCLUSION: Intermittent PTH helped treat ovariectomy-induced osteoporosis of cancellous bone and cortical bone in the femoral necks of rats. The ability of the femoral neck to resist fracture was highly correlated with the two parameters, namely cross-sectional area (CSA) and bone strength index (= vBMD × CSA), of cortical bone in the femoral neck and was less correlated with aBMD or other bone structural parameters.


Assuntos
Colo do Fêmur , Osteoporose , Animais , Feminino , Colo do Fêmur/diagnóstico por imagem , Humanos , Osteoporose/tratamento farmacológico , Osteoporose/etiologia , Ovariectomia , Hormônio Paratireóideo , Ratos , Ratos Sprague-Dawley , Ratos Wistar , Microtomografia por Raio-X
5.
J Oral Maxillofac Surg ; 80(4): 775-783, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34968419

RESUMO

PURPOSE: Reconstruction plates are frequently used to treat mandibular segmental defects. The aim of this study is to compare the biomechanical performance of a 3-dimensional-printed self-designed titanium alloy reconstruction plate with that of the traditional reconstruction plate in mandible reconstruction. The analyzed parameters of the self-designed reconstruction plate, including plate length (100 mm and 125 mm), plate thickness (2.1, 2.4, and 2.7 mm), and bone mass (100, 75, and 50%), were also evaluated. METHODS: An artificial mandible with anatomical geometry was used to develop the self-designed reconstructed plate. Both in vitro experiments and finite element simulations were performed for the biomechanical comparison of the self-designed and traditional reconstruction plates. In finite element analysis, 3 major muscle forces of mandible movement were set as the loading condition, and the displacement of the condyle was fixed in all directions as the boundary condition. RESULTS: The biomechanical performances (stresses in the plate and strains in bone) of the self-designed reconstruction plate were superior to those of the traditional plate. Factorial analysis indicated that plate length and thickness had significant effects on decreasing stresses of the plate and mandibular bone. CONCLUSIONS: The self-designed reconstruction plate might have a benefit to reduce the stresses/strains in plate itself and surrounding bone.


Assuntos
Mandíbula , Reconstrução Mandibular , Fenômenos Biomecânicos , Placas Ósseas , Análise de Elementos Finitos , Humanos , Mandíbula/cirurgia , Reconstrução Mandibular/métodos , Impressão Tridimensional , Estresse Mecânico
6.
J Formos Med Assoc ; 121(4): 796-801, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34535377

RESUMO

BACKGROUND/PURPOSE: Incisor liability is the discrepancy in the sum of the mesiodistal crown width between the primary and permanent incisors. Incisor liability affects the integrity and eruption of the permanent incisors during the transition from the primary to permanent dentition. This study investigated the incisor liability in the primary dentition of Taiwanese children. METHODS: The digital periapical films of 203 upper arches of 105 boys and 98 girls and 195 lower arches of 119 boys and 76 girls aged between 3 and 6 years were selected in this retrospective study. The mesiodistal crown widths of the primary and permanent incisors were measured using the medical imaging software for both arches. Differences in incisor liability values were statistically analyzed. RESULTS: The mean ± standard deviation of the incisor liability values were 8.32 ± 1.88 and 6.91 ± 1.13 mm for the upper and lower arches, respectively, in all children. The incisor liability was closely related with the total crown widths of the permanent incisors for upper and lower arches. The incisor liability values were higher among boys than girls for the upper but not lower arch. CONCLUSION: Incisor liability differs depending on ethnicity. In Taiwanese children, incisor liability was closely related with the crown widths of the permanent incisors. The incisor liability values of boys were higher than those of girls in the upper arch but not the lower arch.


Assuntos
Incisivo , Erupção Dentária , Povo Asiático , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Estudos Retrospectivos
7.
Medicina (Kaunas) ; 58(3)2022 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-35334612

RESUMO

Background and Objectives: Hepatitis C virus (HCV) is a major cause of liver disease worldwide. People who inject drugs (PWIDs) constitute the majority of patients with HCV infection in the United States and Central Asia. There are several obstacles to treating HCV infection in PWIDs because PWIDs are often accompanied by concurrent infection, low compliance, substance abuse, and risky behavior. The aim of the study is to compare the efficacies of direct-acting antiviral (DAA) therapy for HCV infection in PWIDs and those without opioid injection. Materials and Methods: In this retrospective cohort study, we included 53 PWIDs with HCV infections treated on site in a methadone program and 106 age- and sex-matched patients with HCV infections who had no history of opioid injection (ratio of 1:2). All eligible subjects received anti-HCV treatment by DAA agents in our hospital from March 2018 to December 2020. The charts of these patients were carefully reviewed for demographic data, types of DAA agents, and treatment outcomes. The primary outcome measure was sustained virological response (SVR). Results: PWIDs and non-drug users had different HCV genotype profiles (p = 0.013). The former had higher proportions of genotype 3 (18.9% vs. 7.5%) and genotype 6 (24.5% vs. 14.2%) than the latter. The two patient groups had comparable rates of complete drug refilling (100.0% vs. 91.1%) and frequency of loss to follow-up (3.8% vs. 0.9%). However, PWIDs had a lower SVR rate of DAA treatment than non-drug users (92.2% vs. 99.0%; p = 0.04). Further analysis showed that both human immunodeficiency virus (HIV) coinfection and history of PWID were risk factors associated with treatment failure. The subjects with coinfection with HIV had lower SVR rates than those without HIV infection (50.0% vs. 96.5%; p = 0.021). Conclusions: PWIDs with HCV infections have higher proportions of HCV genotype 3 and genotype 6 than non-drug users with infections. DAA therapy can achieve a high cure rate (>90%) for HCV infection in PWID, but its efficacy in PWID is lower than that in non-drug users.


Assuntos
Usuários de Drogas , Infecções por HIV , Hepatite C Crônica , Hepatite C , Abuso de Substâncias por Via Intravenosa , Antivirais/uso terapêutico , Infecções por HIV/complicações , Hepacivirus/genética , Hepatite C/complicações , Hepatite C/tratamento farmacológico , Hepatite C Crônica/complicações , Humanos , Estudos Retrospectivos , Abuso de Substâncias por Via Intravenosa/complicações , Abuso de Substâncias por Via Intravenosa/tratamento farmacológico
8.
BMC Musculoskelet Disord ; 22(1): 146, 2021 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-33546670

RESUMO

BACKGROUND: Metacarpal shaft fracture is a common fracture in hand trauma injuries. Surgical intervention is indicated when fractures are unstable or involve considerable displacement. Current fixation options include Kirschner wire, bone plates, and intramedullary headless screws. Common complications include joint stiffness, tendon irritation, implant loosening, and cartilage damage. OBJECTIVE: We propose a modified fixation approach using headless compression screws to treat transverse or short-oblique metacarpal shaft fracture. MATERIALS AND METHODS: We used a saw blade to model transverse metacarpal neck fractures in 28 fresh porcine metacarpals, which were then treated with the following four fixation methods: (1) locked plate with five locked bicortical screws (LP group), (2) regular plate with five bicortical screws (RP group), (3) two Kirschner wires (K group), and (4) a headless compression screw (HC group). In the HC group, we proposed a novel fixation model in which the screw trajectory was oblique to the long axis of the metacarpal bone. The entry point of the screw was in the dorsum of the metacarpal neck, and the exit point was in the volar cortex of the supracondylar region; thus, the screw did not damage the articular cartilage. The specimens were tested using a modified three-point bending test on a material testing system. The maximum fracture forces and stiffness values of the four fixation types were determined by observing the force-displacement curves. Finally, the Kruskal-Wallis test was adopted to process the data, and the exact Wilcoxon rank sum test with Bonferroni adjustment was performed to conduct paired comparisons among the groups. RESULTS: The maximum fracture forces (median ± interquartile range [IQR]) of the LP, RP, HC, and K groups were 173.0 ± 81.0, 156.0 ± 117.9, 60.4 ± 21.0, and 51.8 ± 60.7 N, respectively. In addition, the stiffness values (median ± IQR) of the LP, HC, RP, and K groups were 29.6 ± 3.0, 23.1 ± 5.2, 22.6 ± 2.8, and 14.7 ± 5.6 N/mm, respectively. CONCLUSION: Headless compression screw fixation provides fixation strength similar to locked and regular plates for the fixation of metacarpal shaft fractures. The headless screw was inserted obliquely to the long axis of the metacarpal bone. The entry point of the screw was in the dorsum of the metacarpal neck, and the exit point was in the volar cortex of the supracondylar region; therefore the articular cartilage iatrogenic injury can be avoidable. This modified fixation method may prevent tendon irritation and joint cartilage violation caused by plating and intramedullary headless screw fixation.


Assuntos
Fraturas Ósseas , Ossos Metacarpais , Animais , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Ossos Metacarpais/diagnóstico por imagem , Ossos Metacarpais/cirurgia , Suínos
9.
BMC Musculoskelet Disord ; 22(1): 431, 2021 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-33971840

RESUMO

BACKGROUND: Metacarpal shaft fractures are a common type of hand fracture. Despite providing strong fixation strength, plate fixation has numerous shortcomings. Concerning internal fixation with Kirschner wires (K-wires), although this approach is frequently used to treat metacarpal shaft fractures, the lack of functional stability may result in fixation failure. OBJECTIVE: To evaluate the effect of figure-of-eight cerclage wire on fixation for transverse metacarpal shaft fractures using two K-wires. MATERIALS AND METHODS: We used a saw blade to create transverse metacarpal shaft fractures in 14 fourth-generation artificial third metacarpal bones (Sawbones, Vashon, WA, USA), which were assigned to groups undergoing fixation with two K-wires (KP) or with two K-wires and figure-of-eight cerclage wire (KP&F8). All specimens were subjected to material testing, specifically cantilever bending tests. The maximum fracture force and stiffness of the two fixation types were determined on the basis of the force-displacement data. The Mann-Whitney U test was used to compare between-group differences in maximum fracture force and stiffness. RESULTS: The maximum fracture force of the KP group (median ± interquartile range = 97.30 ± 29.70 N) was significantly lower than that of the KP&F8 group (153.2 ± 69.50 N, p < 0.05; Figure 5a), with the median of the KP&F8 group exceeding that of the KP group by 57.5%. Similarly, stiffness was significantly lower in the KP group (18.14 ± 9.84 N/mm) than in the KP&F8 group (38.25 ± 23.49 N/mm; p < 0.05; Figure 5b), with the median of the KP&F8 group exceeding that of the KP group by 110.9%. CONCLUSION: The incorporation of a figure-of-eight cerclage wire increased the maximum fracture force and stiffness by 57.5 and 110.9%, respectively, compared with those achieved in standard two K-wire fixation. Therefore, hand surgeons are advised to consider the proposed approach to increase fixation strength.


Assuntos
Fraturas Ósseas , Ossos Metacarpais , Placas Ósseas , Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Ossos Metacarpais/diagnóstico por imagem , Ossos Metacarpais/cirurgia
10.
Clin Oral Investig ; 25(10): 5661-5670, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33665683

RESUMO

OBJECTIVE: The study objective was to investigate four common occlusal modes by using the finite element (FE) method and to conduct a biomechanical analysis of the periodontal ligament (PDL) and surrounding bone when orthodontic force is applied. MATERIALS AND METHODS: A complete mandibular FE model including teeth and the PDL was established on the basis of cone-beam computed tomography images of an artificial mandible. In the FE model, the left and right mandibular first premolars were not modeled because both canines required distal movement. In addition, four occlusal modes were simulated: incisal clench (INC), intercuspal position (ICP), right unilateral molar clench (RMOL), and right group function (RGF). The effects of these four occlusal modes on the von Mises stress and strain of the canine PDLs and bone were analyzed. RESULTS: Occlusal mode strongly influenced the distribution and value of von Mises strain in the canine PDLs. The maximum von Mises strain values on the canine PDLs were 0.396, 1.811, 0.398, and 1.121 for INC, ICP, RMOL, and RGF, respectively. The four occlusal modes had smaller effects on strain distribution in the cortical bone, cancellous bone, and miniscrews. CONCLUSION: Occlusal mode strongly influenced von Mises strain on the canine PDLs when orthodontic force was applied. CLINICAL RELEVANCE: When an FE model is used to analyze the biomechanical behavior of orthodontic treatments, the effect of muscle forces caused by occlusion must be considered.


Assuntos
Ligamento Periodontal , Técnicas de Movimentação Dentária , Dente Pré-Molar/diagnóstico por imagem , Fenômenos Biomecânicos , Simulação por Computador , Análise de Elementos Finitos , Ligamento Periodontal/diagnóstico por imagem , Estresse Mecânico
11.
BMC Oral Health ; 21(1): 543, 2021 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-34674692

RESUMO

BACKGROUND: Many types of titanium plates were used to treat subcondylar fracture clinically. However, the efficacy of fixation in different implant positions and lengths of the bone plate has not been thoroughly investigated. Therefore, the primary purpose of this study was to use finite element analysis (FEA) to analyze the biomechanical effects of subcondylar fracture fixation with miniplates at different positions and lengths so that clinicians were able to find a better strategy of fixation to improve the efficacy and outcome of treatment. METHODS: The CAD software was used to combine the mandible, miniplate, and screw to create seven different FEA computer models. These models with subcondylar fracture were fixed with miniplates at different positions and of different lengths. The right unilateral molar clench occlusal mode was applied. The observational indicators were the reaction force at the temporomandibular joint, von Mises stress of the mandibular bone, miniplate and screw, and the sliding distance on the oblique surface of the fracture site at the mandibular condyle. RESULTS: The results showed the efficacy of fixation was better when two miniplates were used comparing to only one miniplates. Moreover, using longer miniplates for fixation had better results than the short one. Furthermore, fixing miniplates at the posterior portion of subcondylar region would have a better fixation efficacy and less sliding distance (5.46-5.76 µm) than fixing at the anterolateral surface of subcondylar region (6.10-7.00 µm). CONCLUSION: Miniplate fixation, which was placed closer to the posterior margin, could effectively reduce the amount of sliding distance in the fracture site, thereby achieving greater stability. Furthermore, fixation efficiency was improved when an additional miniplate was placed at the anterior margin. Our study suggested that the placement of miniplates at the posterior surface and the additional plate could effectively improve stability.


Assuntos
Fraturas Mandibulares , Placas Ósseas , Fixação de Fratura , Fixação Interna de Fraturas , Humanos , Côndilo Mandibular/cirurgia , Fraturas Mandibulares/cirurgia
12.
J Formos Med Assoc ; 119(10): 1514-1523, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31883628

RESUMO

BACKGROUND/PURPOSE: Impact of the implant shape on the biomechanical performance of all-on-four treatment of dental implant is still unclear. This study evaluated the all-on-four treatment with four osseointegrated implants in terms of the biomechanical effects of implant design and loading position on the implant and surrounding bone by using both in vitro strain gauge tests and three-dimensional (3D) finite element (FE) analyses. METHODS: Both in vitro and 3D FE models were constructed with placing NobelSpeedy and NobelActive implants as well as a titanium framework in an edentulous jawbone based on the concept of all-on-four treatment. Three types of loads were applied: at the central incisor area (loading position 1) and at the molar regions with (loading position 2) and without (loading position 3) the denture cantilever. For the in vitro tests, the principal bone strains were recorded by rosette strain gauges and statistically evaluated using Wilcoxon's rank-sum test. The 3D FE simulations analyzed the peak von-Mises stresses in the implant and surrounding cortical bone. RESULTS: The peak stress and strain in the surrounding bone were typically 36-62% (3D FE analysis) and 47-57% (in vitro test) (p < 0.001)higher for loading position 3 than for loading positions 1 and 2. Between those two implant designs, the bone strains and bone stresses did not differ significantly. CONCLUSION: For all-on-four treatment with four osseointegrated dental implants, altering the implant design does not appear to affect the biomechanical performance of the entire treatment, especially in terms of the stresses and strains in the surrounding bone.


Assuntos
Mandíbula , Fenômenos Biomecânicos , Implantes Dentários , Análise do Estresse Dentário , Dentaduras , Análise de Elementos Finitos , Humanos , Técnicas In Vitro , Mandíbula/cirurgia , Estresse Mecânico
13.
BMC Med Imaging ; 19(1): 10, 2019 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-30674282

RESUMO

BACKGROUND: In this study, we explored how various preprocessing approaches can be employed to enhance the capability of dental CBCT to accurately estimate trabecular bone microarchitectural parameters. METHODS: In total, 30 bovine vertebrae cancellous bone specimens were used for in study. Voxel resolution 18-µm micro-computed tomography (micro-CT) and 100-µm dental CBCT were used to scan each specimen. Micro-CT images were used to calculate trabecular bone microarchitectural parameters; the results were set as the gold standard. Subsequently, before the dental CBCT images were converted into binary images to calculate trabecular bone microarchitectural parameters, three preprocessing approaches were used to process the dental CBCT images. For Group 1, no preprocessing approach was applied. For Group 2, images were sharpened and despeckable noises were removed. For Group 3, the function of local thresholding was added to Group 2 to form Group 3. For Group 4, the air pixels was removed from Group 3 to form Group 4. Subsequently, all images were imported into a software package to estimate trabecular bone microarchitectural parameters (bone volume fraction (BV/TV), trabecular thickness (TbTh), trabecular number (TbN), and trabecular separation (TbSp)). Finally, a paired t-test and a Pearson correlation test were performed to compare the capability of micro-CT with the capability of dental CBCT for estimating trabecular bone microarchitectural parameters. RESULTS: Regardless of whether dental CBCT images underwent image preprocessing (Groups 1 to 4), the four trabecular bone microarchitectural parameters measured using dental CBCT images were significantly different from those measured using micro-CT images. However, after three image preprocessing approaches were applied to the dental CBCT images (Group 4), the BV/TV obtained using dental CBCT was highly positively correlated with that obtained using micro-CT (r = 0.87, p < 0.001); the correlation coefficient was greater than that of Group 1 (r = -0.15, p = 0.412), Group 2 (r = 0.16, p = 0.386), and Group 3 (r = 0.47, p = 0.006). After dental CBCT images underwent image preprocessing, the efficacy of using dental CBCT for estimating TbN and TbSp was enhanced. CONCLUSIONS: Image preprocessing approaches can be used to enhance the efficacy of using dental CBCT for predicting trabecular bone microarchitectural parameters.


Assuntos
Osso Esponjoso/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/veterinária , Arcada Osseodentária/diagnóstico por imagem , Animais , Bovinos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Sensibilidade e Especificidade , Microtomografia por Raio-X
14.
J Formos Med Assoc ; 118(6): 1047-1054, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30391109

RESUMO

BACKGROUND/PURPOSE: Type 1 diabetes mellitus (T1DM) is a chronic autoimmune disease affecting oral health. Evidence shows possible association between T1DM and periodontal diseases (PDs). We conducted a nationwide population-based study in Taiwan, with a 14-year follow-up to investigate the risk of PDs in T1DM patients. METHODS: We used data from the National Health Insurance Research Database in Taiwan. The T1DM cohort was identified with newly diagnosed T1DM from 1998 to 2011. The non-T1DM cohort was frequency matched with the T1DM cohort. Participants comprised 4248 patients in the T1DM cohort and 16992 persons in the non-T1DM cohort. RESULTS: The T1DM patients showed an increased risk of PDs compared to non-T1DM individuals [adjusted hazard ratio (aHR) = 1.45]. T1DM patients who visited the emergency room more than twice per year had a higher aHR of 13.0 for developing PDs. The aHR for PDs was 13.2 in the T1DM patients who had been hospitalized more than twice per year. CONCLUSION: T1DM patients are at higher risk of developing PDs than non-T1DM individuals. Our results further showed that the number of T1DM interventions; that is, annual emergency visits and hospitalizations were associated with increased the risk of developing PDs.


Assuntos
Diabetes Mellitus Tipo 1/complicações , Doenças Periodontais/epidemiologia , Adolescente , Adulto , Criança , Bases de Dados Factuais , Feminino , Humanos , Incidência , Masculino , Análise Multivariada , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Taiwan/epidemiologia , Adulto Jovem
15.
J Formos Med Assoc ; 117(7): 598-604, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28811069

RESUMO

BACKGROUND/PURPOSE: Spaced primary dentition plays a critical role in the eruption of permanent teeth and the establishment of ideal occlusion. A lack of these spaces in deciduous dentition may result in disproportionate jaw and tooth sizes. Additionally, spaced primary dentition is significantly affected by ethnic factors. However, few of these studies have been conducted in Asia. The purpose of this study was to investigate the prevalence of spaced primary dentition in Taiwan. METHODS: One hundred and forty-seven 3- to 6-year-old Taiwanese children (58 girls and 89 boys) were recruited for a cross-sectional study. Primate and interdental spaces were recorded by intraoral photos. The prevalence of spaced dentition was evaluated. The interpersonal agreement of spaced dentition between the upper and lower arches was also assessed. RESULTS: Most of the subjects had spaced primary dentition. The prevalence of primate space was 83.7% in the upper arch and 61.2% in the lower arch, whereas the prevalence of interdental space was 44.2% in the upper arch and 53.1% in the lower arch. The prevalence rates of interdental space and upper primate space were significantly higher in boys than in girls. Interdental spaces of the lower arch increased with age. CONCLUSION: Ethnic factors can affect the ratio of spaced dentition. Most of the 3- to 6-year-old Taiwanese children have spaced dentition. The boys have higher incidence of spaced dentition than the girls. Furthermore, primate space is more frequently found in the upper arch than in the lower arch, whereas interdental space is reversed.


Assuntos
Arco Dental/anatomia & histologia , Dente Decíduo/anatomia & histologia , Fatores Etários , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Masculino , Odontometria , Prevalência , Fatores Sexuais , Taiwan , Erupção Dentária
16.
BMC Musculoskelet Disord ; 18(1): 171, 2017 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-28438150

RESUMO

BACKGROUND: Intermittent parathyroid hormone (PTH) can be used to treat osteoporosis of the spine and hip. However, whether it can be used to treat osteoporosis of the mandible is unclear. The purpose of this study was to explore the influence of applying intermittent PTH to ovariectomized rats on the trabecular bone microarchitecture of the mandible and femoral head. METHODS: Eighteen female rats were divided into three groups: the healthy group, ovariectomized (OVX) group, and OVX + PTH group. The OVX group and OVX + PTH group had an OVX at 8 weeks of age. The OVX + PTH group received intermittent PTH therapy for 12 weeks. The mandibles and femurs of all rats were removed at 20 weeks and were then scanned using microcomputed tomography (micro-CT). RESULTS: From the micro-CT analysis, the trabecular bone microarchitecture of the mandible and femoral head are offered as follows: (1) The bone volume fraction and trabecular thickness in the OVX group were lower than those in the healthy group. (2) The bone volume fraction and trabecular thickness in the OVX + PTH group approximated those in the healthy group. CONCLUSION: The conclusions of this study regarding the trabecular bone microarchitecture of the mandible and femoral head are offered as follows: (1) The BV/TV and TbTh in the OVX group were lower than those in the healthy group. (2) The BV/TV and TbTh in the OVX + PTH group approximated those in the healthy group, therefore, intermittent PTH displayed high efficacy for treating femoral or mandibular deterioration of bone microstructure resulting from loss of ovarian function. Osteoporosis of the femur or mandible in the rats was ameliorated by intermittent PTH therapy.


Assuntos
Cabeça do Fêmur/efeitos dos fármacos , Cabeça do Fêmur/diagnóstico por imagem , Mandíbula/efeitos dos fármacos , Mandíbula/diagnóstico por imagem , Ovariectomia/efeitos adversos , Hormônio Paratireóideo/administração & dosagem , Animais , Feminino , Ovariectomia/tendências , Ratos , Ratos Wistar , Microtomografia por Raio-X/métodos
17.
J Formos Med Assoc ; 116(8): 582-590, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28551316

RESUMO

BACKGROUND/PURPOSE: This study investigated the effects of three three-dimensional (3D) bone-to-implant contact (BIC) parameters-potential BIC area (pBICA), BIC area (BICA), and 3D BIC percentage (3D BIC%; defined as BICA divided by pBICA)-in relation to the implant diameter on primary implant stability, as well as their correlations were also evaluated. METHODS: Dental implants with diameters of 3.75, 4, 5, and 6 mm and artificial bone specimens were scanned by microcomputed tomography to construct 3D models for calculating pBICA, BICA, and 3D BIC%. Indexes of the primary implant stability including the insertion torque value (ITV), Periotest value (PTV), and implant stability quotient (ISQ) were measured after implants with various diameters were placed into bone specimens. The Kruskal-Wallis test, Wilcoxon rank-sum test with Bonferroni adjustment, and Spearman correlations were all performed as statistical and correlation analyses. RESULTS: The implant diameter significantly influenced pBICA and BICA, but not 3D BIC%. ITV and PTV were more sensitive to implant diameter than was ISQ. The coefficients of determination were high (>0.92) for the correlations between pBICA (or BICA) and indexes of the primary implant stability. CONCLUSION: This study revealed how the implant diameter and the three-dimensional (3D) BIC influence the primary stabilities of dental implant. ITV and PTV were more sensitively influenced by the implant diameter than ISQ. The pBICA and BICA seem to be more important than 3D BIC % for using wider implant in treatment plan, since those two parameters are highly predictive of variations in the primary stability of dental implant.


Assuntos
Implantes Dentários , Análise do Estresse Dentário , Humanos , Microtomografia por Raio-X
18.
BMC Oral Health ; 17(1): 132, 2017 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-29157247

RESUMO

BACKGROUND: The influences of potential bone-to-implant contact (BIC) area (pBICA), BIC area (BICA), and three dimensional (3D) BIC percentage (3D BIC%; defined as BICA divided by pBICA) in relation to the implant length on initial implant stability were studied. Correlations between these parameters were also evaluated. METHODS: Implants with lengths of 8.5, 10, 11.5, and 13 mm were placed in artificial bone specimens to measure three indexes of the initial implant stability: insertion torque value (ITV), Periotest value (PTV), and implant stability quotient (ISQ). The implants and bone specimens were also scanned by microcomputed tomography, and the obtained images were imported into Mimics software to reconstruct the 3D models and calculate the parameters of 3D bone-to-implant contact including pBICA, BICA, and 3D BIC%. The Kruskal-Wallis test, Wilcoxon rank-sum test with Bonferroni adjustment, and Spearman correlations were applied for statistical and correlation analyses. RESULTS: The implant length affected ITV more than PTV and ISQ, and significantly affected pBICA, BICA, and 3D BIC%. A longer implant increased pBICA and BICA but decreased 3D BIC%. The Spearman coefficients were high (>0.78) for the correlations between the three 3D BIC parameters and the three indexes of the initial implant stability. CONCLUSIONS: pBICA, BICA, and 3D BIC% are useful when deciding on treatment plans related to various implant lengths, since these 3D BIC parameters are predictive of the initial implant stability.


Assuntos
Osso e Ossos/diagnóstico por imagem , Implantes Dentários , Análise do Estresse Dentário , Desenho de Prótese , Humanos , Imageamento Tridimensional , Modelos Dentários , Microtomografia por Raio-X
20.
J Formos Med Assoc ; 115(9): 794-800, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27013111

RESUMO

BACKGROUND/PURPOSE: Small-diameter dental implants are associated with a higher risk of implant failure. This study used both three-dimensional finite-element (FE) simulations and in-vitro experimental tests to analyze the stresses and strains in both the implant and the surrounding bone when using one-piece (NobelDirect) and two-piece (NobelReplace) small-diameter implants, with the aim of understanding the underlying biomechanical mechanisms. METHODS: Six experimental artificial jawbone models and two FE models were prepared for one-piece and two-piece 3.5-mm diameter implants. Rosette strain gauges were used for in-vitro tests, with peak values of the principal bone strain recorded with a data acquisition system. Implant stability as quantified by Periotest values (PTV) were also recorded for both types of implants. Experimental data were analyzed statistically using Wilcoxon's rank-sum test. In FE simulations, the peak value and distribution of von-Mises stresses in the implant and bone were selected for evaluation. RESULTS: In in-vitro tests, the peak bone strain was 42% lower for two-piece implants than for one-piece implants. The PTV was slightly lower for one-piece implants (PTV = -6) than for two-piece implants (PTV = -5). In FE simulations, the stresses in the bone and implant were about 23% higher and 12% lower, respectively, for one-piece implants than those for two-piece implants. CONCLUSION: Due to the higher peri-implant bone stresses and strains, one-piece implants (NobelDirect) might be not suitable for use as small-diameter implants.


Assuntos
Implantes Dentários/classificação , Análise do Estresse Dentário/métodos , Maxila/diagnóstico por imagem , Estresse Mecânico , Fenômenos Biomecânicos , Dente Suporte , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA