Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Ann Acad Med Singap ; 35(4): 266-9, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16710498

RESUMO

INTRODUCTION: Posterior segment involvement has been described to be associated with central nervous system involvement in sarcoidosis as a result of direct sarcoid tissue infiltration or mass effect of a cerebral lesion. However, isolated intermediate uveitis occurring concurrently with central nervous system involvement prior to extensive systemic disease is rare. CLINICAL PICTURE: We describe a patient with neuro-ophthalmic manifestations of intermediate uveitis and an enhancing basal ganglia lesion at initial presentation, in the absence of extensive systemic disease. TREATMENT: He was treated with high-dose systemic steroids which was progressively tailed down over 6 months. OUTCOME: There was prompt resolution of vitritis with good preservation of visual acuity. CONCLUSION: The difficulties of the initial diagnosis of sarcoidosis and the indications for initiation of steroid therapy are illustrated. We use this case to emphasise the need for a high clinical suspicion of sarcoidosis in the presence of similar unusual and seemingly unrelated combinations of neurological manifestations so as to facilitate the prompt institution of appropriate treatment when indicated.


Assuntos
Gânglios da Base/fisiopatologia , Isquemia Encefálica/diagnóstico , Sarcoidose/diagnóstico , Uveíte/diagnóstico , Adulto , Angiografia , Gânglios da Base/diagnóstico por imagem , Isquemia Encefálica/complicações , Comorbidade , Diagnóstico Diferencial , Humanos , Imageamento por Ressonância Magnética , Masculino , Sarcoidose/complicações , Fatores de Tempo , Tomografia Computadorizada por Raios X , Uveíte/complicações
2.
Invest Ophthalmol Vis Sci ; 52(12): 8884-90, 2011 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-21828152

RESUMO

PURPOSE: To determine the interobserver and intraobserver measurement reproducibility of cornea parameters of both normal eyes and eyes with bullous keratopathy (BK) obtained with the Zhongshan Assessment Program (ZAP) on anterior segment optical coherence tomography (AS-OCT) images. METHODS: A comparative study was carried out on 24 healthy volunteers and 25 subjects with BK. AS-OCT images were independently analyzed by two examiners. Parameters examined: anterior chamber depth (ACD), central corneal thickness (CCT), posterior corneal curvature (PCC), and posterior corneal arc length (PCAL). Interobserver and intraobserver reproducibility of these parameters was calculated in terms of limits of agreement (mean of differences ± 1.96SD of differences). RESULTS: In the normal group, both horizontal and vertical ACD were successfully measured in 23 of 24 (96%) images. The mean bias for two measurements by two different observers ranged from 0.003 to 0.117 mm for ACD, PCC, and PCAL measurements and from 0.013 to 2.25 µm for CCT measurements, and there were no differences between the two observers (P > 0.05). Mean bias for two measurements by the same grader ranged from 0.005 to 0.327 mm for ACD, PCC, and PCAL measurements and 1.46 to 2.53 µm for CCT measurements. There was no difference between the two observations (P > 0.05). Similar results were found in the BK group. CONCLUSIONS: There was high inter- and intraobserver reproducibility for normal and pathologic corneas using the ZAP software. The ZAP software may serve as a new investigatory tool for accurately evaluating the anterior segment and corneal parameters for corneal procedures.


Assuntos
Segmento Anterior do Olho/patologia , Vesícula/patologia , Córnea/patologia , Doenças da Córnea/patologia , Tomografia de Coerência Óptica/normas , Adulto , Câmara Anterior/anatomia & histologia , Diagnóstico por Computador/normas , Diagnóstico por Computador/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Software/normas , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/estatística & dados numéricos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA