Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Acta Ophthalmol ; 102(5): e705-e711, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38334238

RESUMO

PURPOSE: To evaluate the performance of intraocular lens (IOL) calculation formulas and the effect of anterior chamber depth (ACD), axial length (AL) and lens thickness (LT) on the prediction accuracy in shallow ACD eyes. METHODS: This retrospective, consecutive case-series study included 648 eyes of 648 patients with an ACD < 3.0 mm who underwent phacoemulsification and IOL implantation. Eleven formulas were evaluated: Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) 2.0, Hill-Radial Basis Function (RBF) 3.0, Hoffer QST, Kane, Olsen, Pearl-DGS and traditional formulas (Haigis, Hoffer Q, Holladay 1 and SRK/T). Subgroup analysis was performed based on ACD, AL and LT. RESULTS: Overall, the Hoffer QST and Kane showed no systematic bias. The Kane, EVO 2.0, Hill-RBF 3.0 and Hoffer QST had relatively lower mean absolute error and higher percentages of prediction error within ±0.5 D. For the ACD of 2.5-3.0 mm and AL < 22.0 mm subgroup, the Pearl-DGS exhibited the lowest MAE (0.45 D) and MedAE (0.41 D). Most formulas had a significant myopic bias (-0.43 to -0.18 D, p < 0.05) in the LT < 4.3 mm subgroup and a significant hyperopic bias (0.09-0.29 D, p < 0.05) in the LT ≥ 5.1 mm subgroup. CONCLUSION: The Kane and Hoffer QST were recommended for shallow ACD eyes. In eyes with an ACD between 2.5 and 3.0 mm and a short AL, the Pearl-DGS showed excellent performance. Clinicians need to fine-tune the target refraction according to LT in shallow ACD eyes.


Assuntos
Câmara Anterior , Comprimento Axial do Olho , Biometria , Lentes Intraoculares , Refração Ocular , Humanos , Câmara Anterior/diagnóstico por imagem , Estudos Retrospectivos , Masculino , Feminino , Biometria/métodos , Idoso , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Facoemulsificação , Reprodutibilidade dos Testes , Acuidade Visual/fisiologia , Óptica e Fotônica , Implante de Lente Intraocular , Idoso de 80 Anos ou mais
2.
Biomater Res ; 28: 0021, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38828365

RESUMO

With the high incidence rate, distinctive implant characteristic and unique infection pattern, peri-implantitis (PI) requires a specially designed implant animal model for the researches on the pathogenesis and treatments. Previous small-animal PI models exhibit variability in implant site selection, design, and surgical procedures resulting in unnecessary tissue damage and less effectivity. Herein, a quantitative-analysis-based standardized rat model for transmucosal PI-related research was proposed. After dissecting the anatomic structures of the rat maxilla, we determined that placing the implant anterior to the molars in the rat maxilla streamlined the experimental period and enhanced animal welfare. We standardized the model by controlling the rat strain, gender, and size. The customized implant and a series of matched surgical instruments were appropriately designed. A clear, step-by-step surgical process was established. These designs ensured the success rate, stability, and replicability of the model. Each validation method confirmed the successful construction of the model. This study proposed a quantitative-analysis-based standardized transmucosal PI rat model with improved animal welfare and reliable procedures. This model could provide efficient in vivo insights to study the pathogenesis and treatments of PI and preliminary screening data for further large-animal and clinical trials.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA