Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 153
Filtrar
1.
Pacing Clin Electrophysiol ; 47(5): 595-602, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38523591

RESUMO

BACKGROUND: Data are lacking on patient-reported outcomes (PRO) following cryoballoon ablation (CBA) versus radiofrequency ablation (RFA). We sought to evaluate QoL and clinical outcomes of cryoballoon pulmonary vein isolation only (CRYO-PVI-ONLY) versus RFA with PVI and posterior wall isolation (RF-PVI+PWI) in a large prospective PRO registry. METHODS: Patients who underwent AF ablation (2013-2016) at our institution were enrolled in an automated, prospectively maintained PRO registry. CRYO-PVI-ONLY patients were matched (1:1) with RF-PVI+PWI patients based on age, gender, and type of AF (paroxysmal vs. persistent). QoL and clinical outcomes were assessed using PRO surveys at baseline and at 1-year. The atrial fibrillation symptom severity scale (AFSSS) was the measure for QoL. Additionally, we assessed patient-reported clinical improvement, arrhythmia recurrence, and AF burden (as indicated by AF frequency and duration scores). RESULTS: A total of 296 patients were included (148 in each group, 72% paroxysmal). By PRO, a significant improvement in QoL was observed in the overall study population and was comparable between CRYO-PVI-ONLY and RF-PVI+PWI (baseline median AFSSS of 11.5 and 11; reduced to 2 and 4 at 1 year, respectively; p = 0.44). Similarly, the proportion of patients who reported improvement in their overall QoL and AF related symptoms was high and similar between the study groups [92% (CRYO-PVI-ONLY) vs. 92.8% (RF-PVI+PWI); p = 0.88]. Arrhythmia recurrence was significantly more common in the CRYO-PVI-ONLY group (39.7%) compared to RF-PVI+PWI (27.7 %); p = 0.03. Comparable results were observed in paroxysmal and persistent AF. CONCLUSION: CRYO-PVI-ONLY and RF-PVI+PWI resulted in comparable improvements in patient reported outcomes including QoL and AF burden; with RF-PVI+PWI being more effective at reducing recurrences.


Assuntos
Fibrilação Atrial , Criocirurgia , Medidas de Resultados Relatados pelo Paciente , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Masculino , Feminino , Criocirurgia/métodos , Fibrilação Atrial/cirurgia , Pessoa de Meia-Idade , Estudos Prospectivos , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Sistema de Registros , Qualidade de Vida , Idoso , Ablação por Radiofrequência/métodos
2.
J Cardiovasc Electrophysiol ; 34(3): 765-768, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36738138

RESUMO

Guidelines recommend using the CHA2DS2-VASc score to determine anticoagulation decisions in atrial fibrillation (AF) patients, including those who undergo pulmonary vein isolation (PVI), however this may not consistently occur in the real-world setting because of other clinical factors. We sought to evaluate the anticoagulation prescription rates patterns in AF patients 1 year PVI at our institution. Consecutive AF patients undergoing PVI in our prospective registry during 2014-2018 who were alive at 1-year post-PVI were studied. Anticoagulation prescription rates at this time-point were adjudicated, and correlated to CHA2DS2-VASc score, sex, and heart rhythm status at 1 year. Amongst 4596 patients undergoing PVI, mean age was 64.2 ± 10.0 years, 1328 (28.9%) were female, and based on CHA2DS2-VASc score anticoagulation was not indicated, can be considered and indicated in 872 (19.0%), 1183 (25.7%), and 2541 (55.3%) patients, respectively. At 1-year after PVI, 3504 (76.2%) patients were on anticoagulation, and 792 (17.2%) had recurrence of AF. Anticoagulation was continued in over half of AF patients without classic CHA2DS2-VASc indication particularly in those with AF recurrence and women, while they were mildly under-prescribed in those with indication, especially for those without AF recurrence and men. In a large real world cohort of patients after PVI, anticoagulation prescription is not solely depending on the CHA2DS2-VASc score and sex, but also heart rhythm status and other clinical or imaging factors.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Medição de Risco/métodos , Coagulação Sanguínea , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 34(12): 2493-2503, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37870157

RESUMO

INTRODUCTION: The prospective, nonrandomized, multicenter Q-FFICIENCY study demonstrated the safety and 12-month efficacy of paroxysmal atrial fibrillation (AF) ablation with the novel QDOT MICRO temperature-controlled, contact force-sensing, radiofrequency (RF) catheter. Participants underwent pulmonary vein isolation with very high-power short-duration (vHPSD) mode (90 W, ≤4 s) alone or combined with conventional-power temperature-controlled (CPTC) mode (25-50 W). This study aimed to assess quality-of-life (QOL) and healthcare utilization (HCU) benefits experienced by Q-FFICIENCY study participants. METHODS: Besides evaluating procedural efficiency, QOL and HCU were assessed through 12 months postablation via Atrial Fibrillation Effect on Quality-of-Life Tool (AFEQT) score, antiarrhythmic drug (AAD) use, and incidence of cardioversion and cardiovascular hospitalization. RESULTS: Of 191 participants enrolled, 166 were ablated with the new catheter. Compared to baseline, statistically significant, clinically meaningful improvements in composite and subcategories of AFEQT scores were observed at 3 months and sustained through 12 months (12-month increase, 29.3-44.2 points). Class I/III AAD use decreased from 97.6% (162/166) at baseline to 19.6% (31/158) during Months 6-12, representing a significant 79.9% reduction. The cardioversion rate significantly declined by 93.9% from 31.3% (12 months preablation) to 1.9% (evaluation period). One-year Kaplan-Meier estimates of freedom from all-cause and cardiovascular hospitalization were 80.9% (95% confidence interval [CI], 74.8%-86.9%) and 88.8% (95% CI, 84.0%-93.7%), respectively. CONCLUSIONS: Paroxysmal AF ablation with the novel temperature-controlled RF catheter in vHPSD mode, alone or with CPTC mode, led to clinically meaningful improvement in QOL and significant reduction in AAD use, cardioversion, and cardiovascular hospitalization.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Prospectivos , Qualidade de Vida , Temperatura , Resultado do Tratamento , Catéteres , Antiarrítmicos/uso terapêutico , Veias Pulmonares/cirurgia , Aceitação pelo Paciente de Cuidados de Saúde , Ablação por Cateter/efeitos adversos
4.
J Cardiovasc Electrophysiol ; 34(1): 54-61, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36259719

RESUMO

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) is frequently used for the purpose of rhythm control and improved quality of life (QoL). Although success rates are high, a significant proportion of patients require redo ablation. Data are scarce on patient-centered outcomes and QoL in patients undergoing redo AF ablation. We aimed to assess QoL and clinical outcomes using a large prospectively maintained patient-reported outcomes (PRO) registry. METHODS: All patients undergoing redo AF ablation (2013-2016) at our center were enrolled in a prospective registry for outcomes and assessed for QoL using automated PRO surveys (baseline, 3 and 6 months after ablation, every 6 months thereafter). Data were collected over 3 years of follow-up. The atrial fibrillation symptom severity scale (AFSSS) was used as the main measure for QoL. Additional variables included patient-reported improvement, AF burden, and AF-related healthcare utilization including emergency room (ER) visits and hospitalizations. RESULTS: A total of 848 patients were included (28% females, mean age 63.8, 51% persistent AF). By automated PRO, significant improvement in QoL was noted (baseline median AFSSS of 12 [5-18] and ranged between 2 and 4 on subsequent assessments; p < .0001), with ≥70%of patients reported remarkable improvement in their AF-related symptoms. The proportion of patients in AF at the time of baseline survey was 36%, and this decreased to <8% across all time points during follow-up (p < .0001). AF burden was significantly reduced (including frequency and duration of episodes; p < .0001), with an associated decrease in healthcare utilization after 6 months from the time of ablation (including ER visits and hospitalizations; p < .0001). The proportion of patients on anticoagulants or antiarrhythmics decreased on follow-up across all time points (p < .0001 for all variables). CONCLUSION: Most patients derive significant QoL benefit from redo AF ablation; with reduction of both AF burden and healthcare utilization.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Feminino , Humanos , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Qualidade de Vida , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Ablação por Cateter/efeitos adversos , Medidas de Resultados Relatados pelo Paciente
5.
J Cardiovasc Electrophysiol ; 34(8): 1648-1657, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493505

RESUMO

INTRODUCTION: Obesity is a well-known risk factor for atrial fibrillation (AF). We aim to evaluate the effect of baseline obesity on procedural complications, AF recurrence, and symptoms following catheter ablation (CA). METHODS: All consecutive patients undergoing AF ablation (2013-2021) at our center were enrolled in a prospective registry. The study included all consecutive patients with available data on body mass index (BMI). Primary endpoint was AF recurrence based on electrocardiographic documentation. Patients were categorized into five groups according to their baseline BMI. Patients survey at baseline and at follow-up were used to calculate AF symptom severity score (AFSS) as well as AF burden (mean of AF duration score and AF frequency score; scale 0: no AF to 10: continuous and 9 frequencies/durations in between). Patients were scheduled for follow-up visits with 12-lead electrocardiogram at 3, 6, and 12 months after ablation, and every 6 months thereafter. RESULTS: A total of 5841 patients were included (17% normal weight, 34% overweight, 27% Class I, 13% Class II, and 9% Class III obesity). Major procedural complications were low (1.5%) among all BMI subgroups. At 3 years AF recurrence was the highest in Class III obesity patients (48%) followed by Class II (43%), whereas Class I, normal, and overweight had similar results with lower recurrence (35%). In multivariable analyses, Class III obesity (BMI ≥ 40) was independently associated with increased risk for AF recurrence (hazard ratio, 1.30; confidence interval, 1.06-1.60; p = .01), whereas other groups had similar risk in comparison to normal weight. Baseline AFSS was lowest in normal weight, and highest in Obesity-III, median (interquartile range) 10 (5-16) versus 15 (10-21). In all groups, CA resulted in a significant improvement in their AFSS with a similar magnitude among the groups. At follow-up, AF burden was minimal and did not differ significantly between the groups. CONCLUSION: AF ablation is safe with a low complication rate across all BMI groups. Morbid obesity (BMI ≥ 40) was significantly associated with reduced AF ablation success. However, ablation resulted in improvement in QoL including reduction of the AFSS, and AF burden regardless of BMI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Qualidade de Vida , Sobrepeso/diagnóstico , Recidiva , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Obesidade/complicações , Obesidade/diagnóstico , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 33(9): 1994-2000, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35689504

RESUMO

INTRODUCTION: Pulmonary venous (PV) electrical recovery underlies most arrhythmia recurrences after atrial fibrillation (AF) ablation. Little is known about procedural profiles and outcomes of patients with electrically silent PVs upon redo ablation for AF. METHODS: In a prospectively maintained registry, we enrolled 838 consecutive patients (2013-2016) undergoing redo ablation procedures. Ablation procedures targeted the PVs, the PV antra, and non-PV sites at operators' discretion. Procedural profiles and clinical outcomes were assessed. The primary outcome was freedom from AF after a 3-month blanking period. The secondary outcome was improvement in quality of life. RESULTS: Most patients undergoing redo AF ablation (n = 684, 82%) had PV reconnection while the remaining 154 (18%) had electrically silent PVs. Patients with recurrent AF and electrically silent PVs were older (66 vs. 64 years, p = .02), had more prior ablation procedures (median 2 IQR 1-3 vs 1 IQR 1-2 p = .001), were more likely to have non-paroxysmal AF (62% vs. 49%, p = .004) and atrial flutter (48% vs. 29%, p = .001) and had significantly larger left atrial volumes (89 vs. 81 ml, p = .003). Patients with silent PVs underwent a more extensive non-PV ablation strategies with antral extension of prior ablation sets in addition to ablation of the roof, appendage, inferior to the right PVs, peri-mitral flutter lines, cavotricuspid isthmus lines and ablation in the coronary sinus. Upon one year of follow-up, patients with electrically silent PVs were less likely to remain free from recurrent atrial arrhythmias (64% vs. 76%, p = .008). Regardless of PV reconnection status, redo ablation resulted in improvement in quality of life. CONCLUSION: Rhythm control with extensive ablation allowed maintenance of sinus rhythm in about two thirds of patients with silent PVs during redo AF ablation procedures. Regardless of PV reconnection status, redo ablation resulted in improvement in quality of life. This remains a challenging group of patients, highlighting the need to better understand non-PV mediated AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Qualidade de Vida , Recidiva , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 33(2): 197-208, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34855270

RESUMO

BACKGROUND: Antiarrhythmic drugs (AADs) and catheter ablation are first line treatments of paroxysmal atrial fibrillation (PAF), however, there exists a paucity of data regarding the potential benefit of different catheter ablation technologies versus AADs as an early rhythm strategy. OBJECTIVE: To assess the safety and efficacy of cryoablation versus radiofrequency ablation (RFA) versus AADs as a first line therapy of PAF. METHODS: MEDLINE, Embase, Scopus and CENTRAL were searched to retrieve randomized clinical trials (RCTs) comparing cryoablation, RFA or AADs to one another as first line therapies for atrial fibrillation (AF). The primary outcome was overall freedom from arrhythmia recurrence (AF, atrial flutter [AFL], atrial tachycardia). Secondary outcomes included freedom from symptomatic arrhythmia recurrence, hospitalization, and serious adverse events. A random-effects Bayesian network meta-analysis was used to calculate odds ratios (OR) and 95% credible intervals (CrI). RESULTS: Six RCTs (N = 1212) met the inclusion criteria (605 AADs, 365 Cryoablation, and 245 RFA). Compared with AADs, overall recurrence was reduced with RFA (OR: 0.31; 95% CrI: 0.10-0.71) and cryoablation (OR: 0.39; 95% CrI: 0.16-1.00). Comparing ablation (cryoablation and RFA) with AADs in respect to freedom from symptomatic AF recurrence, neither cryoablation (OR: 0.35; 95% CrI: 0.06-1.96) nor RFA (OR: 0.34; 95% CrI: 0.07-1.27) resulted in statistically significant reductions individually compared to AADs, though pooled ablation with both technologies showed lower odds of arrhythmia recurrence (OR: 0.35; 95% CrI: 0.13-0.79). In terms of serious adverse events rates, neither cryoablation (OR: 0.77; 95% CrI: 0.44-1.39) nor RFA (OR: 1.45; 95% CrI: 0.67-3.23) were significantly different to AADs. RFA resulted in a statistically significant reduction in hospitalizations compared to AAD (OR: 0.08; 95% CrI: 0.01-0.99), whereas cryoablation did not (OR: 0.77; 95% CrI: 0.44-1.39). The surface under the cumulative ranking curve showed RFA to be the most effective treatment at reducing overall rates of recurrence, symptomatic recurrence and hospitalizations; whereas cryoablation was most likely to reduce serious adverse events. CONCLUSION: Cryoablation and RFA are both effective and safe first line therapies for AF compared to AADs, with RFA being the most effective at reducing recurrences.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Ablação por Radiofrequência , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Humanos , Metanálise em Rede , Recidiva , Resultado do Tratamento
8.
Rev Cardiovasc Med ; 23(3): 112, 2022 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-35345279

RESUMO

BACKGROUND: Catheter ablation is an effective treatment for atrial fibrillation (AF), primarily performed in patients who fail antiarrhythmic drugs. Whether early catheter ablation, as first-line therapy, is associated with improved clinical outcomes remains unclear. METHODS: Electronic databases (PubMed, Scopus, Embase) were searched until March 28th, 2021. Randomized controlled trials (RCTs) compared catheter ablation vs antiarrhythmic drug therapy as first-line therapy were included. The primary outcome of interest was the first documented recurrence of any atrial tachyarrhythmia (symptomatic or asymptomatic; AF, atrial flutter, and atrial tachycardia). Secondary outcomes included symptomatic atrial tachyarrhythmia (AF, atrial flutter, and atrial tachycardia) and serious adverse events. Unadjusted risk ratios (RR) were calculated from dichotomous data using Mantel Haenszel (M-H) random-effects with statistical significance considered if the confidence interval (CI) excludes one and p < 0.05. RESULTS: A total of six RCTs with 1212 patients (Ablation n = 609; Antiarrhythmic n = 603) were included. Follow- up period ranged from 1-2 years. Patients who underwent ablation were less likely to experience any recurrent atrial tachyarrhythmia when compared to patients receiving antiarrhythmic drugs (RR 0.63; 95% CI 0.55-0.73; p < 0.00001). Symptomatic atrial tachyarrhythmia was also lower in the ablation arm (RR 0.53; 95% CI 0.32-0.87; p = 0.01). No statistically significant differences were noted for overall any type of adverse events (RR 0.93; 95% CI 0.68-1.27; p = 0.64) and cardiovascular adverse events (RR 0.90; 95% CI 0.56-1.44; p = 0.65) respectively. CONCLUSIONS: Catheter ablation, as first-line therapy, was associated with a significantly lower rate of tachyarrhythmia recurrence compared to conventional antiarrhythmic drugs, with a similar adverse effect risk profile. These findings support a catheter ablation strategy as first-line therapy among patients with symptomatic paroxysmal atrial fibrillation.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Flutter Atrial/tratamento farmacológico , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Recidiva , Taquicardia/tratamento farmacológico , Taquicardia/etiologia , Taquicardia/cirurgia , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 32(7): 1909-1917, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33955116

RESUMO

BACKGROUND: Activation maps of scar-related atrial tachycardias (AT) can be challenging to interpret due to difficulty in inaccurate annotation of electrograms, and an arbitrarily predefined mapping window. A novel mapping software integrating vector data and applying an algorithmic solution taking into consideration global activation pattern has been recently described (Coherent™, Biosense Webster "Investigational"). OBJECTIVE: We aimed to assess the investigational algorithm to determine the mechanism of AT compared with the standard algorithm. METHODS: This study included patients who underwent ablation of scar-related AT using the Carto 3 and the standard activation algorithm. The mapping data were analyzed retrospectively using the investigational algorithm, and the mechanisms were evaluated by two independent electrophysiologists. RESULTS: A total of 77 scar-related AT activation maps were analyzed (89.6% left atrium, median tachycardia cycle length of 273 ms). Of those, 67 cases with a confirmed mechanism of arrhythmia were used to compare the activation software. The actual mechanism of the arrhythmia was more likely to be identified with the investigational algorithm (67.2% vs. 44.8%, p = .009). In five patients with dual-loop circuits, 3/5 (60%) were correctly identified by the investigational algorithm compared to 0/5 (0%) with the standard software. The reduced atrial voltage was prone to lead to less capable identification of mechanism (p for trend: .05). The investigational algorithm showed higher inter-reviewer agreement (Cohen's kappa .62 vs. .47). CONCLUSIONS: In patients with scar-related ATs, activation mapping algorithms integrating vector data and "best-fit" propagation solution may help in identifying the mechanism and the successful site of termination.


Assuntos
Ablação por Cateter , Cicatriz , Algoritmos , Cicatriz/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Taquicardia
10.
Circ Res ; 124(11): 1584-1597, 2019 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-31120815

RESUMO

The population of patients with heart failure continues to grow, which introduced significant challenges in clinical practice related to the management of cardiac arrhythmia and advanced heart failure syndromes. Device therapy has increasingly become essential in the management of life-threatening arrhythmia and clinical heart failure in this population. This review will discuss the use of cardiac implantable electronic devices in heart failure with primary focus on sudden cardiac death prevention and cardiac resynchronization, including published evidence and evolving technologies.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Dispositivos Eletrônicos Vestíveis , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Humanos , Prevenção Primária , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Prevenção Secundária , Resultado do Tratamento , Função Ventricular
11.
J Cardiovasc Electrophysiol ; 31(8): 1979-1986, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32510749

RESUMO

BACKGROUND: Morbid obesity is associated with prohibitively high arrhythmia recurrence rates following atrial fibrillation (AF) ablation. DESIGN: This was a single-center study comprising 239 patients with morbid obesity and symptomatic paroxysmal or persistent AF undergoing AF ablation compared to 239 patients with a body mass index less than 30 kg/m2 matched based on age, sex, ejection fraction, AF type, presence and type of heart failure, and left atrial volume index. METHODS: Our primary outcome of interest was arrhythmia recurrence. RESULTS: During a mean follow-up of 29 months, arrhythmia recurrence was observed in 65% of the morbidly obese cohort compared to 27% of the control group (P < .0001). Among those with morbid obesity, sleep apnea screening, and treatment (91% vs 40%; P < .0001), blood pressure control (62% vs 53%; P = .001), glycemic control (85% vs 56%; P = .004), and weight loss more than equal to 5% (33% vs 57% in those who lost less than 5% and 83% in those who gained weight, P < .0001) were associated with lower arrhythmia recurrence. Recurrent arrhythmia was observed in one (4%) patient who accomplished all four goals, compared to 36% who achieved 3 of 4, 85% who modified 2 of 4%, and 97% of those who modified zero or one risk-factor. Risk-factor modification (RFM) was also associated with substantial reductions in the need for repeat ablation or direct-current cardioversion and arrhythmia-related hospitalization (P < .0001). CONCLUSION: RFM through pragmatic noninvasive means such as blood pressure and glycemic control, sleep apnea screening and treatment, and weight loss is associated with substantially lower rates of recurrent arrhythmia among morbidly obese patients undergoing AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Obesidade Mórbida , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Humanos , Obesidade Mórbida/complicações , Obesidade Mórbida/diagnóstico , Obesidade Mórbida/cirurgia , Recidiva , Fatores de Risco , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 31(5): 1182-1186, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32108406

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is indicated in patients with medically refractory heart failure and wide QRS duration. While much is known about predictors of left ventricular (LV) remodeling after CRT implantation and short-term mortality, limited data exist on long-term outcomes after CRT placement. METHODS: We retrospectively reviewed all patients undergoing CRT implantation at our center between 2003 and 2008 and examined mortality using institutional electronic records, social security death index, and online obituary search. We included only patients with preimplant echoes with LV ejection fraction (LVEF) 35% or below. Variable selection was performed using stepwise regression and models were compared using goodness-of-fit criteria. A final model was validated with the bootstrap regression method. RESULTS: Out of the 877 CRT patients undergoing implantation during this time, 287 (32.7%) survived longer than 10 years. Significant (P < .05) predictors of survival in our multivariate model were age, left ventricular diastolic diameter, sex, presence of nonischemic vs ischemic cardiomyopathy, QRS duration, atrial fibrillation, BNP levels, and creatinine levels at the time of CRT implantation. A model using the odds ratios from these variables had a receiver operating curve with an area under the curve score of 0.816 (standard error, 0.019) at predicting survival or freedom from LVAD or heart transplant for longer than 10 years after CRT implantation. The specificity for factors 3 or above and 5 or above was 68% and 77%, respectively. CONCLUSION: A large proportion of patients are still alive 10 years after CRT implantation. Variables at the time of CRT implant can help provide prognostic information to patients and electrophysiologists to determine the long-term benefit and survival of patients after CRT implantation.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sobreviventes , Fatores de Tempo , Resultado do Tratamento
13.
J Card Fail ; 26(3): 227-232, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31881279

RESUMO

INTRODUCTION: Cardiac resynchronization therapy (CRT) has been shown to improve survival in patients with systolic heart failure, wide QRS duration, and left-bundle-branch-block. However, CRT outcomes stratified by right ventricular (RV) function at implant have not been well studied. METHODS: We retrospectively reviewed patients at Cleveland Clinic who underwent CRT implantation (n = 777) from 2003 to 2011 with a diagnosis of heart failure, echocardiography with both pre-CRT left ventricular ejection fraction (LVEF) ≤35% and available post-CRT echocardiography at 6 months post-implant. CRT response was defined as LVEF improvement ≥5%. Patients were separated into 2 groups: normal or mild RV dysfunction (n = 570) labeled Normal RV; moderate to severe dysfunction (n = 207) labeled RV DYSFXN based on qualitative echocardiography assessment. Survival was calculated as time from CRT implant to death, left ventricular assist device implant, or heart transplant. RESULTS: CRT response was significantly higher in patients with Normal RV (67%) compared with patients with RV DYSFXN (56%; P = .006). Kaplan-Meier analysis showed that CRT patients with Normal RV had significantly greater survival compared with patients with RV DYSFXN (P < .001). In multivariable Cox regression accounting for a priori covariates, RV DYSFXN was associated with worse survival (HR 1.41 [95% CI: 1.14-1.75], P = .002) and lower CRT response (HR 0.66 [95% CI: 0.44-0.97], P = .03). CONCLUSION: Baseline RV dysfunction at CRT implant is an important predictor of worsened left ventricular remodeling and survival in CRT patients.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Direita , Insuficiência Cardíaca/terapia , Humanos , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/terapia , Função Ventricular Esquerda
14.
Europace ; 22(2): 259-264, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32031230

RESUMO

AIMS: Atrial fibrillation (AF) occurs in as many as 70% of patients with transthyretin cardiac amyloidosis (ATTR CA). The aim of our study was to investigate the impact of AF ablation on freedom from recurrent arrhythmia, hospitalization for AF or heart failure (HF), and mortality. METHODS AND RESULTS: This was a retrospective observational cohort study of 72 patients with ATTR CA and AF, of whom 24 underwent AF ablation and were matched in a 2:1 manner based on age, gender, ATTR CA stage, New York Heart Association functional class, ejection fraction, and date of AF diagnosis with 48 patients with ATTR CA and AF undergoing medical management. During a mean follow-up of 39 ± 26 months, 10 (42%) patients remained free of recurrent arrhythmia following ablation. Ablation was significantly more effective in those with Stage I or II ATTR CA, with 9/14 (64%) patients with Stage I or II ATTR CA remaining free of recurrent arrhythmia compared to only 1/10 (10%) patients with Stage III disease (P = 0.005). Death occurred in 7 (29%) patients in the ablation group compared to 36 (75%) in the non-ablation arm (P = 0.01). Rates of ischaemic stroke were similar in both groups. Ablation was associated with a significant reduction in the frequency of hospitalization for HF/arrhythmia (1.7 ± 2.4 hospitalizations vs. 4 ± 3.5, P = 0.005). On Cox proportional hazards analyses, ablation was associated with improved survival (hazard ratio 0.38, 95% confidence intervals 0.17-0.86; P = 0.02). CONCLUSION: Atrial fibrillation ablation is associated with reduced mortality in ATTR CA and is most effective when performed earlier during the disease process.


Assuntos
Amiloidose , Fibrilação Atrial , Isquemia Encefálica , Ablação por Cateter , Acidente Vascular Cerebral , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos de Coortes , Humanos , Pré-Albumina , Resultado do Tratamento
15.
Pacing Clin Electrophysiol ; 43(7): 720-729, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32452039

RESUMO

BACKGROUND: Programmed long AV delays and intrinsic long first degree AV block may increase risk for competitive atrial pacing (CAP) in devices without CAP avoidance algorithms. METHODS: Patients identified with CAP-induced mode switch episodes were followed clinically from September 2013 to August 2019. Attempts to avoid CAP included shortening of postventricular atrial refractory period (PVARP) or postventricular atrial blanking period (PVAB), or change to AAI or DDI modes. After observing associations with sensor-driven pacing, rate response was inactivated in a subset. RESULTS: Among 23 patients identified with CAP (22 St Jude Medical [Abbott]; one Boston Scientific Corporation devices), atrial fibrillation (AF) was induced in 12 (52%), lasting 10 seconds to 28 hours and 32 minutes. In one patient with an ICD CAP-induced AF with rapid ventricular rates that triggered a shock, inducing ventricular fibrillation, syncope, and another shock. Changing AV delays and shortening of PVARP failed to resolve CAP. After noting that all had CAP during sensor-driven pacing, rate response was inactivated in seven, resolving further device-induced AF in the three of seven that had prior CAP-induced AF. In two patients with intact AV conduction, AAI(R) pacing resolved further documentation of CAP. CONCLUSIONS: CAP predominantly occurs during sensor-driven atrial pacing that competes with intrinsic atrial events falling in PVARP. Inactivation of the activity sensor or change to atrial-based pacing modes (AAI/R) appears to effectively prevent induction of device-induced atrial proarrhythmia. Ultimately, a corrective algorithm is needed to avoid CAP-induced proarrhythmia.


Assuntos
Algoritmos , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Desfibriladores Implantáveis , Átrios do Coração/fisiopatologia , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
16.
Pacing Clin Electrophysiol ; 43(1): 118-122, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31782195

RESUMO

BACKGROUND: Advancement of digital technology now allows patients to have access to data from their cardiac implantable electronic devices (CIEDs). However, patients' understanding regarding CIED data and perceived personal usability remain unclear. The present study is a prospective survey to examine patients' understanding of their CIEDs and their perception of what is important. METHODS: We screened 400 patients between July and December 2018 who presented to our outpatient clinic for a CIED interrogation. Patients received a one-page questionnaire asking baseline demographics, their perception about their own knowledge about their device, and multiple-choice questions in seven basic categories: type of CIED, original indication, functionality, manufacturer, number of active leads, estimated battery life, and number of shocks received. We compared these answers to their interrogation reports to assess accuracy. We also asked participants what they would like to be aware of regarding their CIED. RESULTS: From this cohort, 344 of 400 (86%) (62.9 ± 12.8 years and 64 % males) agreed to take the survey and were included in the analysis. At baseline, 63.2% agreed or strongly agreed that they were knowledgeable about their devices. The overwhelming majority of patients demonstrated CIED knowledge deficits in at least one content area (n = 294, 86%), or more than two content areas (n = 176, 51%). Patients agreed or strongly agreed that they had a desire to have information regarding each of the following: battery life (84%), activity level (79%), heart rate trend (75%), and ventricular arrhythmias (74%). CONCLUSION: There is a large discrepancy in patients' level of knowledge regarding their CIEDs and their wish to know more details. Future technologies should satisfy providers' goals to educate their patients with basic information and fulfill patients' desire to obtain more data from their CIEDs.


Assuntos
Acesso à Informação , Atitude Frente a Saúde , Desfibriladores Implantáveis/psicologia , Marca-Passo Artificial/psicologia , Pacientes/psicologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Inquéritos e Questionários
17.
J Cardiovasc Electrophysiol ; 30(11): 2427-2432, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31515942

RESUMO

BACKGROUND: The aim of our study was to investigate outcomes of patients with ATTR (amyloidosis and transthyretin) CA (cardiac amyloidosis) and implantable devices with respect to left ventricular ejection fraction (LVEF), mitral regurgitation (MR), New York Heart Association (NYHA) functional class, and mortality. METHODS: This was a retrospective observational cohort study of 78 patients with ATTR CA and implantable devices. During a mean follow-up of 42 months we investigated the impact of right ventricular (RV) pacing burden and biventricular (BiV) pacing on LVEF, MR severity, NYHA functional class, and mortality. RESULTS: Worsening MR occurred in 11% of patients with a RV pacing % <40% compared to 62% of those with a RV pacing burden >40% (P = .002). Similarly, worsening LVEF occurred in 26% of patients who were RV paced <40% and 89% of those who were RV paced >40% of the time (P < .0001) and worsening in NYHA functional class occurred in 22% and 89%, respectively (P < .0001). Improvement in LVEF, NYHA functional class, and MR severity occurred in 78%, 67%, and 67%, respectively, in those with BiV devices. Death occurred in 67% of patients in the cardiac resynchronization therapy group compared to 68% of those with a RV pacing burden <40% and 92% of those with a RV pacing burden >40%. CONCLUSION: A higher RV pacing burden is associated with deleterious remodeling and congestive heart failure in patients with ATTR CA, whereas BiV pacing is associated with improvements in LVEF, NYHA class, and degree of MR. BiV pacing should be considered in patients with ATTR CA and an indication for pacing. However, further larger prospective studies will need to be performed.


Assuntos
Neuropatias Amiloides Familiares/terapia , Estimulação Cardíaca Artificial , Cardiomiopatias/terapia , Hemodinâmica , Insuficiência da Valva Mitral/fisiopatologia , Valva Mitral/fisiopatologia , Marca-Passo Artificial , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Neuropatias Amiloides Familiares/complicações , Neuropatias Amiloides Familiares/mortalidade , Neuropatias Amiloides Familiares/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/mortalidade , Terapia de Ressincronização Cardíaca , Dispositivos de Terapia de Ressincronização Cardíaca , Cardiomiopatias/complicações , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Tomada de Decisão Clínica , Bases de Dados Factuais , Progressão da Doença , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/mortalidade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Direita
18.
J Cardiovasc Electrophysiol ; 30(10): 1979-1983, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31211474

RESUMO

INTRODUCTION: In patients with chronic systolic heart failure and frequent right ventricular pacing (RVP), upgrade to cardiac resynchronization therapy (CRT) has become common practice despite a lack of randomized clinical trials. We aimed to evaluate long term outcomes in patients upgraded to CRT from chronic RVP compared with de novo CRT implants. METHODS AND RESULTS: We reviewed medical charts on consecutive patients with a left ventricular ejection fraction (LVEF) ≤ 35% and a QRSd ≥ 120 ms undergoing CRT. Survival free of left ventricular assist device (LVAD) and a heart transplant was compared amongst patients on the basis of pre-CRT QRS morphology. Improvement in LVEF was also compared across groups. A total of 1260 patients met inclusion criteria of whom 233 were upgraded from chronic RVP. Over a mean follow up 6.5 ± 4.0 years there were 821 endpoints (27 LVAD, 30 heart transplants, and 764 deaths). In a multivariate Cox regression model, upgraded patients had worse outcomes (HR 1.3(1.1-1.7) P = .007) compared with those with native LBBB and similar outcomes to patients with non-LBBB(HR 0.96(0.76-1.21) P = .7). The survival curve for chronic RVP parallels native LBBB for approximately 2.5 years before dropping sharply. Patients with chronic RVP derive similar improvements in LVEF compared with those with LBBB and superior improvements compared with those with non-LBBB. CONCLUSIONS: Despite achieving similar levels of LVEF improvement, patients with systolic heart failure with chronic RVP undergoing upgrade to CRT have inferior long term outcomes compared with patients with native LBBB. Long term outcomes with CRT in patients with chronic RVP, RBBB, and IVCD are similar.


Assuntos
Bloqueio de Ramo/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca Sistólica/terapia , Função Ventricular Direita , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Doença Crônica , Progressão da Doença , Feminino , Insuficiência Cardíaca Sistólica/diagnóstico , Insuficiência Cardíaca Sistólica/fisiopatologia , Transplante de Coração , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
19.
Am J Transplant ; 18(12): 3021-3028, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29607624

RESUMO

We performed a retrospective review of 402 consecutive patients who underwent heart transplantation at our institution between January 2009 and March 2017. A retained cardiovascular implantable electronic device (CIED) fragment was identified after transplantation in 49 of the 301 patients (16.2%) with CIED at baseline. Patients with retained fragments had leads with longer dwell times (median 2596 [1982, 3389] vs 1384 [610, 2202] days, P < .001), higher prevalence of previously abandoned leads (14.3% vs 2.8%, P = .003), and dual-coil defibrillator leads (98% vs 81%, P = .001) compared with patients without retained fragments. Five patients (10%) with retained CIED fragments underwent magnetic resonance imaging without adverse events. There was no difference in overall mortality between patients with and without CIED fragments (12% vs 11%, P = .81) Patients with retained fragments located in the superior vena cava had significantly higher fluoroscopic times (3.3 vs 2.9 minutes, P = .024) during subsequent endomyocardial biopsies. In a competing risk analysis, presence of a retained CIED fragment was associated with upper extremity deep venous thrombosis (sub hazard ratio [HR] 2.19, 95% confidence interval [CI] 1.17-4.10, P = .014) but not bloodstream infection after adjusting for potential confounders. In summary, retained CIED fragments are common after heart transplantation, and are associated with longer radiation exposure during biopsy procedures and upper extremity deep venous thrombosis.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Corpos Estranhos/complicações , Rejeição de Enxerto/etiologia , Cardiopatias/cirurgia , Transplante de Coração/efeitos adversos , Exposição à Radiação/efeitos adversos , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Prognóstico , Estudos Retrospectivos , Fatores de Risco
20.
J Cardiovasc Electrophysiol ; 29(4): 551-558, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29369441

RESUMO

INTRODUCTION: Management of persistent atrial fibrillation (PersAF) remains challenging, and many patients are left on medical therapy after a failed first ablation. In patients with recurrent symptomatic arrhythmias after PersAF ablation, we aimed to compare outcomes of repeat ablation and medical therapy versus medical therapy alone. METHODS AND RESULTS: All 682 consecutive patients with recurrent symptomatic arrhythmia after a first ablation for PersAF at our institution (2005-2012) were included. Repeat ablation with continuation of medical therapy was performed in 364 patients (Group 1) and 318 were only medically managed (Group 2). The outcome of interest was freedom from arrhythmia recurrence beyond a 3-month blanking period. Separate analyses were performed to assess this endpoint totally off antiarrhythmics (primary endpoint) or alternatively with/without use of antiarrhythmics (secondary endpoint). Over a median follow-up of 26 months, 41.5% of Group 1 patients met the primary endpoint and remained free from arrhythmia recurrence off antiarrhythmics (vs. 14.5% in Group 2, P < 0.0001). At last follow-up, antiarrhythmics continued to be required for rhythm control in 40.1% and 46.2% of patients in Groups 1 and 2, respectively (P < 0.0001). The secondary endpoint was met in 60.2% versus 32.1% of patients in Groups 1 and 2, respectively (P < 0.0001). In multivariable Cox analyses, repeat ablation was associated with significant reduction in arrhythmia recurrences compared to medical therapy alone (HR 0.48, 95% CI 0.35-0.65, P < 0.0001). CONCLUSION: In patients with recurrent symptomatic arrhythmia after ablation of PersAF, repeat ablation was associated with significant reduction in arrhythmia recurrences compared to routine medical therapy alone.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Reoperação , Potenciais de Ação , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Terapia Combinada , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Recidiva , Sistema de Registros , Reoperação/efeitos adversos , Medição de Risco , Fatores de Risco , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA