Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Anal Bioanal Chem ; 416(8): 1857-1865, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38319357

RESUMO

Phosphatidylinositols and their phosphorylated derivatives, known as phosphoinositides, are crucial in cellular processes, with their abnormalities linked to various diseases. Thus, identifying and measuring phosphoinositide levels in tissues are crucial for understanding their contributions to cellular processes and disease development. One powerful technique for mapping the spatial distribution of molecules in biological samples is matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). This technique allows for the simultaneous detection and analysis of multiple lipid classes in situ, making it invaluable for unbiased lipidomic studies. However, detecting phosphoinositides with MALDI-MSI is challenging due to their relatively low abundance in tissues and complex matrix effects. Addressing this, our study focused on optimizing matrix selection and thickness for better detection of phosphatidylinositols and their phosphorylated forms in mouse kidney tissues. Various matrices were assessed, including 9AA, DAN, CMBT, and DHA, adjusting their coating to improve ionization efficiency. Our results demonstrate that DAN, DHA, and CMBT matrices produced high-intensity chemical images of phosphatidylinositol distributions within kidney sections. These matrices, particularly DAN, DHA, and CMBT, allowed the identification of even low-abundance phosphoinositides, through tentative identifications. Notably, DAN and DHA served as optimal candidates due to their prominent detection and ability to map a majority of phosphatidylinositol species, while CMBT showed potential detection capability for phosphatidylinositol triphosphate compounds. These findings not only provide valuable insights for future research on the involvement of phosphoinositides in kidney pathophysiology, but also propose the use of the identified optimal matrices, particularly DAN and DHA, as the preferred choices for enhanced detection and mapping of these lipid species in future studies.


Assuntos
Diagnóstico por Imagem , Fosfatidilinositóis , Animais , Camundongos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Rim , Lasers
2.
Rapid Commun Mass Spectrom ; 37(16): e9594, 2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37430447

RESUMO

RATIONALE: Sublimation is a solvent-free technique used to apply a uniform matrix coating over a large sample plate, improving the matrix's purity and enhancing the analyte signal. Although the 5-chloro-2-mercaptobenzothiazole (CMBT) matrix was introduced years ago, there are no reports of its application via sublimation. We investigated the experimental parameters that are optimal for CMBT matrix sublimation on mouse kidney samples. We also evaluated the stability of the sublimed CMBT matrix under a vacuum environment. Using kidney samples prepared with a sublimated CMBT matrix, we conducted matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) analysis of specific phospholipids (phosphatidylcholine and phosphatidylglycerol in the positive ion mode and phosphatidylinositol in the negative ion mode). We also explored various spatial resolutions (50, 20, and 10 µm) and performed sequential MALDI-hematoxylin and eosin (H&E) staining. METHODS: The CMBT matrix was applied to kidney samples using a sublimation apparatus connected to a vacuum pump to achieve a pressure of 0.05 Torr. The matrix was then subjected to different temperatures and sublimation times to determine the optimal conditions for matrix application. Subsequently, a Q-Exactive mass spectrometer equipped with a Spectroglyph MALDI ion source was employed for MALDI-MSI experiments. Standard protocols were followed for H&E staining after MALDI analysis. RESULTS: A matrix thickness of 0.15 mg/cm2 yielded high-quality images. The sublimated matrix exhibited minimal loss after approximately 20 h of exposure to a vacuum of 7 Torr, indicating its stability under these conditions. Ion images were successfully obtained at spatial resolutions of 50, 20, and 10 µm. Furthermore, orthogonal histological information was obtained through sequential MALDI-H&E staining. CONCLUSIONS: We demonstrate that samples prepared for MALDI-MSI using sublimation to apply the CMBT matrix yield high-quality mass spectrometric images of mouse kidney sections. We also provide data for the impact of various experimental parameters on image quality (e.g., temperature, time, matrix thickness, and spatial resolution).


Assuntos
Rim , Compostos de Sulfidrila , Animais , Camundongos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Amarelo de Eosina-(YS) , Lasers
3.
Rapid Commun Mass Spectrom ; 35(8): e9053, 2021 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-33474774

RESUMO

RATIONALE: We developed a model case study to evaluate three internal standard (IS) application strategies (methods I-III) using the psycholeptic phenobarbital (PB) and the isotopically labelled IS phenobarbital-D5 (PB-D5) from in vitro dosed tissues of the golden apple snail (Pomacea diffusa) by desorption electrospray ionization mass spectrometry imaging (DESI-MSI). METHODS: In method I, the IS was deposited as microspots on top of 10 µm thick snail tissues; in method II, a thin IS film was applied; and in method III, the IS was spiked into the DESI solvent spray. DESI-MSI analyses were performed using a Thermo LTQ mass spectrometer equipped with a custom-built DESI source and two-dimensional moving stage. PB (m/z 231) and PB-D5 (m/z 236) were monitored in selected ion monitoring mode between m/z 227 and 239. RESULTS: The analytical performance of two IS strategies (methods I and II) in DESI-MSI was evaluated based on an intra- and inter-day precision assay, an accuracy assessment, and statistical analysis. In the inter-day DESI-MSI assay, method I exhibited better precision (6.5%-7.4%) than method II (10.7%-17.6%) between 10 and 100 ng/µL. In the accuracy assessment, PB quality controls of 75 ng/µL were back-calculated as 71 ± 4 and 83 ± 9 ng/µL, resulting in relative errors of -5% and 11% for methods I and II, respectively. Method III did not work under the experimental design and was not evaluated. CONCLUSIONS: Three IS application strategies were investigated and compared for a routine quantitative DESI-MSI approach. Methods I and II were not statistically significantly different as shown by a Bland-Altman plot, suggesting that these two methods can be used interchangeably. However, method III requires further research for future quantitative DESI-MSI analyses.

4.
Phytochem Anal ; 31(6): 711-721, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32291820

RESUMO

INTRODUCTION: Lauraceae alkaloids are a structurally diverse class of plant specialised secondary metabolites that play an important role in modern pharmacotherapy, being useful as well as model compounds for the development of synthetic analogues. However, alkaloids characterisation is challenging due to low concentrations, the complexity of plant extracts, and long processes for accurate structural determinations. OBJECTIVE: The use of high-performance thin layer chromatography coupled with desorption electrospray ionisation multistage mass spectrometry (HPTLC DESI-MSn ) as a fast tool to identify alkaloids present in Ocotea spixiana extract and evaluate the extract's acaricide activity. METHODS: Ocotea spixiana twigs were extracted by conventional liquid-liquid partitioning. HPTLC analysis of the ethyl acetate extract was performed to separate isobaric alkaloids prior to DESI-MSn analysis, performed from MS3 up to MS7 . The extract's acaricide activity against Rhipicephalus microplus was evaluated by in vitro (larval immersion test) and in silico tests. RESULTS: HPTLC-DESI-MSn analysis was performed to identify a total of 13 aporphine and four benzylisoquinoline-type alkaloids reported for the first time in O. spixiana. In vitro evaluation of the extract and the alkaloid boldine showed significant activity against R. microplus larvae. It was established in silico that boldine had important intermolecular interactions with R. microplus acetylcholinesterase enzyme. CONCLUSION: The present study demonstrated that HPTLC-DESI-MSn is a useful analytical tool to identify isoquinoline alkaloids in plant extracts. The acaricide activity of the O. spixiana ethyl acetate extract can be correlated to the presence of alkaloids.


Assuntos
Acaricidas , Alcaloides , Aporfinas , Benzilisoquinolinas , Ocotea , Acaricidas/farmacologia , Alcaloides/farmacologia , Aporfinas/farmacologia , Extratos Vegetais/farmacologia , Espectrometria de Massas em Tandem
5.
Rapid Commun Mass Spectrom ; 33 Suppl 3: 27-53, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29698560

RESUMO

Ambient mass spectrometry (AMS)-based techniques are performed under ambient conditions in which the ionization and desorption occur in the open environment allowing the direct analysis of molecules with minimal or no sample preparation. A selected group of AMS techniques demonstrate imaging capabilities that can provide information about the localization of molecules on complex sample surfaces such as biological tissues. 2D, 3D, and multimodal imaging have unlocked an array of applications to systematically address complex problems in many areas of research such as drug monitoring, natural products, forensics, and cancer diagnostics. In the present review, we summarize recent advances in the field with respect to the implementation of new ambient ionization techniques and current applications in the last 5 years. In more detail, we mainly focus on imaging applications in topics related to animal whole bodies and tissues, single cells, cancer diagnostics and biomarkers, microbial cultures and co-cultures, plant and natural product metabolomics, and forensic applications. Finally, we discuss new areas of research, future perspectives, and the overall direction that the field may take in the years to come.

6.
Rapid Commun Mass Spectrom ; 31(12): 983-990, 2017 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-28370721

RESUMO

RATIONALE: Thermochromic ink pens are widely accessible worldwide and have gained popularity among the general public. These pens are very useful to undo mistakes while writing important documents or exams. They are also, however, misused in committing crimes such as counterfeiting checks or wills. Thus, the forensics community is in need of techniques that will allow these forgeries to be detected rapidly, reliably and conveniently. METHODS: Thermochromic ink compounds were investigated using Desorption Electrospray Ionization (DESI) coupled with an LTQ mass spectrometer and Thin-Layer Chromatography (TLC). Tandem mass spectrometric analysis was conducted using Electrospray Ionization (ESI) coupled with an Orbitrap LTQ mass spectrometer performing Collision-Induced Dissociation (CID) for identification of ink traces. RESULTS: Chemical marker ions characteristic of the state of ink (visible or invisible) were identified and mapped in ink traces by the use of DESI-MS imaging. These ions can be employed by forensic experts as fingerprint markers in forged documents. The marker ions were also characterised by conducting tandem mass spectrometry using paper spray in an Orbitrap LTQ mass spectrometer. CONCLUSIONS: Specific chemical components yielding ions of m/z 400, 405, 615 and 786 were distinguished as only being apparent in the invisible and reappeared state of the ink. The absence of these compounds in the original state of the ink enabled their recognition as useful chemical determinants in detecting forgery. DESI-MSI was thus shown to be a very useful, convenient and reliable technique for detecting forgery in paper documents due to its fast and reproducible mode of analysis, with no sample preparation and minimal damage to the document under investigation. Copyright © 2017 John Wiley & Sons, Ltd.

7.
Clin Chem ; 62(1): 111-23, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26555455

RESUMO

BACKGROUND: There is a clinical need for new technologies that would enable rapid disease diagnosis based on diagnostic molecular signatures. Ambient ionization mass spectrometry has revolutionized the means by which molecular information can be obtained from tissue samples in real time and with minimal sample pretreatment. New developments in ambient ionization techniques applied to clinical research suggest that ambient ionization mass spectrometry will soon become a routine medical tool for tissue diagnosis. CONTENT: This review summarizes the main developments in ambient ionization techniques applied to tissue analysis, with focus on desorption electrospray ionization mass spectrometry, probe electrospray ionization, touch spray, and rapid evaporative ionization mass spectrometry. We describe their applications to human cancer research and surgical margin evaluation, highlighting integrated approaches tested for ex vivo and in vivo human cancer tissue analysis. We also discuss the challenges for clinical implementation of these tools and offer perspectives on the future of the field. SUMMARY: A variety of studies have showcased the value of ambient ionization mass spectrometry for rapid and accurate cancer diagnosis. Small molecules have been identified as potential diagnostic biomarkers, including metabolites, fatty acids, and glycerophospholipids. Statistical analysis allows tissue discrimination with high accuracy rates (>95%) being common. This young field has challenges to overcome before it is ready to be broadly accepted as a medical tool for cancer diagnosis. Growing research in new, integrated ambient ionization mass spectrometry technologies and the ongoing improvements in the existing tools make this field very promising for future translation into the clinic.


Assuntos
Biomarcadores Tumorais/análise , Técnicas de Laboratório Clínico , Neoplasias/diagnóstico , Neoplasias/metabolismo , Espectrometria de Massas por Ionização por Electrospray , Humanos
8.
Anal Chem ; 87(6): 3286-93, 2015 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-25710577

RESUMO

This work illustrates reactive desorption electrospray ionization mass spectrometry (DESI-MS) with a stable dication on biological tissues. Rat brain and zebra fish tissues were investigated with reactive DESI-MS in which the dictation forms a stable bond with biological tissue fatty acids and lipids. Tandem mass spectrometry (MS/MS) was used to characterize the dication (DC9) and to identify linked lipid-dication compounds formed. The fragment m/z 85 common to both DC9 fragmentation and DC9-lipid fragmentation was used to confirm that DC9 is indeed bonded with the lipids. Lipid signals in the range of m/z 250-350 and phosphoethanolamines (PE) m/z 700-800 observed in negative ion mode were also detected in positive ion mode with reactive DESI-MS with enhanced signal intensity. Reactive DESI-MS imaging in positive ion mode of rat brain and zebra fish tissues allowed enhanced detection of compounds commonly observed in the negative ion mode.


Assuntos
Imagem Molecular/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Encéfalo/citologia , Encéfalo/metabolismo , Metabolismo dos Lipídeos , Ratos , Peixe-Zebra/metabolismo
9.
Anal Chem ; 87(24): 12298-305, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26637047

RESUMO

Direct analysis of microbial cocultures grown on agar media by desorption electrospray ionization mass spectrometry (DESI-MS) is quite challenging. Due to the high gas pressure upon impact with the surface, the desorption mechanism does not allow direct imaging of soft or irregular surfaces. The divots in the agar, created by the high-pressure gas and spray, dramatically change the geometry of the system decreasing the intensity of the signal. In order to overcome this limitation, an imprinting step, in which the chemicals are initially transferred to flat hard surfaces, was coupled to DESI-MS and applied for the first time to fungal cocultures. Note that fungal cocultures are often disadvantageous in direct imaging mass spectrometry. Agar plates of fungi present a complex topography due to the simultaneous presence of dynamic mycelia and spores. One of the most devastating diseases of cocoa trees is caused by fungal phytopathogen Moniliophthora roreri. Strategies for pest management include the application of endophytic fungi, such as Trichoderma harzianum, that act as biocontrol agents by antagonizing M. roreri. However, the complex chemical communication underlying the basis for this phytopathogen-dependent biocontrol is still unknown. In this study, we investigated the metabolic exchange that takes place during the antagonistic interaction between M. roreri and T. harzianum. Using imprint-DESI-MS imaging we annotated the secondary metabolites released when T. harzianum and M. roreri were cultured in isolation and compared these to those produced after 3 weeks of coculture. We identified and localized four phytopathogen-dependent secondary metabolites, including T39 butenolide, harzianolide, and sorbicillinol. In order to verify the reliability of the imprint-DESI-MS imaging data and evaluate the capability of tape imprints to extract fungal metabolites while maintaining their localization, six representative plugs along the entire M. roreri/T. harzianum coculture plate were removed, weighed, extracted, and analyzed by liquid chromatography-high-resolution mass spectrometry (LC-HRMS). Our results not only provide a better understanding of M. roreri-dependent metabolic induction in T. harzianum, but may seed novel directions for the advancement of phytopathogen-dependent biocontrol, including the generation of optimized Trichoderma strains against M. roreri, new biopesticides, and biofertilizers.


Assuntos
4-Butirolactona/análogos & derivados , Agaricales/metabolismo , Produtos Biológicos/análise , Produtos Biológicos/metabolismo , Butanos/metabolismo , Cicloexanonas/metabolismo , Lactonas/metabolismo , Metabolismo Secundário , Trichoderma/metabolismo , 4-Butirolactona/química , 4-Butirolactona/isolamento & purificação , 4-Butirolactona/metabolismo , Agaricales/crescimento & desenvolvimento , Agaricales/patogenicidade , Produtos Biológicos/química , Produtos Biológicos/isolamento & purificação , Butanos/química , Butanos/isolamento & purificação , Técnicas de Cocultura , Cicloexanonas/química , Cicloexanonas/isolamento & purificação , Lactonas/química , Lactonas/isolamento & purificação , Espectrometria de Massas por Ionização por Electrospray , Trichoderma/crescimento & desenvolvimento , Trichoderma/patogenicidade
10.
Anal Chem ; 87(15): 7683-9, 2015 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-26138213

RESUMO

Mapping intratumoral heterogeneity such as vasculature and margins is important during intraoperative applications. Desorption electrospray ionization mass spectrometry (DESI-MS) has demonstrated potential for intraoperative tumor imaging using validated MS profiles. The clinical translation of DESI-MS into a universal label-free imaging technique thus requires access to MS profiles characteristic to tumors and healthy tissues. Here, we developed contrast agent mass spectrometry imaging (CA-MSI) that utilizes a magnetic resonance imaging (MRI) contrast agent targeted to disease sites, as a label, to reveal tumor heterogeneity in the absence of known MS profiles. Human breast cancer tumors grown in mice were subjected to CA-MSI using Gadoteridol revealing tumor margins and vasculature from the localization of [Gadoteridol+K](+) and [Gadoteridol+Na](+) adducts, respectively. The localization of the [Gadoteridol+K](+) adduct as revealed through DESI-MS complements the in vivo MRI results. DESI-MS imaging is therefore possible for tumors for which no characteristic MS profiles are established. Further DESI-MS imaging of the flux of the contrast agent through mouse kidneys was performed indicating secretion of the intact label.


Assuntos
Neoplasias da Mama/diagnóstico , Meios de Contraste , Espectrometria de Massas por Ionização por Electrospray , Animais , Neoplasias da Mama/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Camundongos
11.
Anal Chem ; 87(24): 12071-9, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26561279

RESUMO

A picosecond infrared laser (PIRL) is capable of cutting through biological tissues in the absence of significant thermal damage. As such, PIRL is a standalone surgical scalpel with the added bonus of minimal postoperative scar tissue formation. In this work, a tandem of PIRL ablation with electrospray ionization (PIR-LAESI) mass spectrometry is demonstrated and characterized for tissue molecular imaging, with a limit of detection in the range of 100 nM for reserpine or better than 5 nM for verapamil in aqueous solution. We characterized PIRL crater size using agar films containing Rhodamine. PIR-LAESI offers a 20-30 µm vertical resolution (∼3 µm removal per pulse) and a lateral resolution of ∼100 µm. We were able to detect 25 fmol of Rhodamine in agar ablation experiments. PIR-LAESI was used to map the distribution of endogenous methoxykaempferol glucoronide in zebra plant (Aphelandra squarrosa) leaves producing a localization map that is corroborated by the literature. PIR-LAESI was further used to image the distribution inside mouse kidneys of gadoteridol, an exogenous magnetic resonance contrast agent intravenously injected. Parallel mass spectrometry imaging (MSI) using desorption electrospray ionization (DESI) and matrix assisted laser desorption ionization (MALDI) were performed to corroborate PIR-LAESI images of the exogenous agent. We further show that PIR-LAESI is capable of desorption ionization of proteins as well as phospholipids. This comparative study illustrates that PIR-LAESI is an ion source for ambient mass spectrometry applications. As such, a future PIRL scalpel combined with secondary ionization such as ESI and mass spectrometry has the potential to provide molecular feedback to guide PIRL surgery.


Assuntos
Lasers , Espectrometria de Massas por Ionização por Electrospray , Animais , Raios Infravermelhos , Rim/citologia , Rim/cirurgia , Limite de Detecção , Camundongos , Camundongos SCID
12.
Rapid Commun Mass Spectrom ; 29(16): 1530-4, 2015 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-26212168

RESUMO

RATIONALE: Citrus aurantium L. is a plant belonging to the Rutaceae family, whose extracts are extensively used in weight management products and as thermogenic agents. Here we present two methodologies to analyse the extracts obtained from the peels of Citrus aurantium L. that usually require multiple sample preparation and detection steps. METHODS: Polar compounds of the crude extract from the peels of Citrus aurantium L. (Rutaceae) were investigated by direct infusion electrospray ionization mass spectrometry (ESI-MS) and high-performance thin-layer chromatography (HPTLC) coupled to desorption electrospray ionization mass spectrometry (DESI-MS). ESI-MS was performed in both positive and negative ion modes. Molecular imaging of the HPTLC plates was used for the direct analysis of the phytocompounds present in the crude extract from the peels of Citrus aurantium L. by DESI-MS imaging. RESULTS: Characteristic mass spectra with many diagnostic ions were obtained from the extract analysis, allowing a fast and reliable identification of these species. Tandem mass spectrometry (MS/MS) was employed to confirm the identity of specific metabolites. CONCLUSIONS: HPTLC/DESI-MS imaging is a relatively fast, versatile, and efficient technique for natural product analysis, since many more ions are observed than with the direct infusion ESI-MS. The MS/MS technique provided information about the component structures, revealing the presence of important bioactive components. The application of DESI-MS imaging may contribute to the improvement identification and characterization of pharmacologically active compounds in phytochemistry.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Citrus/química , Frutas/química , Compostos Fitoquímicos/análise , Extratos Vegetais/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Compostos Fitoquímicos/química
13.
Anal Chem ; 86(23): 11722-6, 2014 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-25369204

RESUMO

In desorption electrospray ionization mass spectrometry (DESI-MS), the type of surface in addition to low gas and solvent flow rates help to avoid the "splashing of solvent" or "washing effect", by which samples are promptly removed from the surface by the spray. These effects operate on smooth surfaces and generally result in unstable signals as the spray moves over the spot. The aim of this work is to compare the performance of functionalized porous silicon surfaces (pSi) for small molecules analysis with regard to the stability of the signal and the limits of detection (LODs) observed in DESI-MS. The results showed that functional groups, like 1-decene and heptadecafluoro-1,1,2,2-tetrahydrodecyl trimethoxysilane, on pSi surface provides a good alternative for dried spot analysis by DESI-MS, improving stability of the signal and the LODs. This improvement is possible because the dual process containing the weak sample-surface interactions of the hydrophobic characteristic of the functional groups and increasing the surface area of interaction between the sample and the thin solvent film created by the DESI spray, resulting in more effective dissolution of the analyte in the spray solvent without fast removal of the sample.

14.
Mass Spectrom Rev ; 32(3): 218-43, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22996621

RESUMO

Mass spectrometry imaging (MSI) has emerged as an important tool in the last decade and it is beginning to show potential to provide new information in many fields owing to its unique ability to acquire molecularly specific images and to provide multiplexed information, without the need for labeling or staining. In MSI, the chemical identity of molecules present on a surface is investigated as a function of spatial distribution. In addition to now standard methods involving MSI in vacuum, recently developed ambient ionization techniques allow MSI to be performed under atmospheric pressure on untreated samples outside the mass spectrometer. Here we review recent developments and applications of MSI emphasizing the ambient ionization techniques of desorption electrospray ionization (DESI), laser ablation electrospray ionization (LAESI), probe electrospray ionization (PESI), desorption atmospheric pressure photoionization (DAPPI), femtosecond laser desorption ionization (fs-LDI), laser electrospray mass spectrometry (LEMS), infrared laser ablation metastable-induced chemical ionization (IR-LAMICI), liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS), nanospray desorption electrospray ionization (nano-DESI), and plasma sources such as the low temperature plasma (LTP) probe and laser ablation coupled to flowing atmospheric-pressure afterglow (LA-FAPA). Included are discussions of some of the features of ambient MSI for example the ability to implement chemical reactions with the goal of providing high abundance ions characteristic of specific compounds of interest and the use of tandem mass spectrometry to either map the distribution of targeted molecules with high specificity or to provide additional MS information on the structural identification of compounds. We also describe the role of bioinformatics in acquiring and interpreting the chemical and spatial information obtained through MSI, especially in biological applications for tissue diagnostic purposes. Finally, we discuss the challenges in ambient MSI and include perspectives on the future of the field.


Assuntos
Espectrometria de Massas/métodos , Imagem Molecular/métodos , Animais , Desenho de Equipamento , Medicina Legal/instrumentação , Medicina Legal/métodos , Humanos , Espectrometria de Massas/instrumentação , Imagem Molecular/instrumentação
15.
Rapid Commun Mass Spectrom ; 28(19): 2084-8, 2014 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-25156598

RESUMO

RATIONALE: To demonstrate the potential use of zebra fish (Danio rerio) as a model vertebrate organism by producing two-dimensional ion images of the whole zebra fish, and being able to distinguish particular areas of interest such as the brain, spinal cord, and stomach region using a desorption electrospray ionization (DESI) ion source coupled to a linear ion trap. METHODS: Imaging experiments are performed on 45 µm sagittal slices of zebra fish (Danio rerio), which are thaw-mounted onto microscope glass slides. The slides are then analyzed using a solvent of acetonitrile/dimethylformamide (50:50) (ACN/DMF), with a solvent flow rate of 1.5 µL/min; data are acquired in negative ion mode. Raw mass spectrum data files are converted into a readable file for Biomap. The images produced are then analyzed for ion distributions. RESULTS: We are able to create clear, distinct, chemical intensity images of the brain, spinal cord, and stomach based on lipid content as well as bile salt. The identities of these compounds were confirmed by tandem mass spectrometric (MS/MS) experiments and comparisons with literature. CONCLUSIONS: Imaging of whole zebra fish is possible using ambient ionization techniques such as DESI. Analyses are fast and reliable. For most of the compounds observed, the identification by MS/MS can be performed directly from the fish tissue sample.


Assuntos
Imagem Molecular/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Imagem Corporal Total/métodos , Peixe-Zebra , Animais , Biomarcadores/química , Masculino
16.
J Mass Spectrom ; 59(2): e5000, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38263874

RESUMO

This study describes a novel application for sandpaper spray ionization mass spectrometry (SPS-MS), to examine the surface of maple tree (Acer sp.) leaves. By comparing mass spectrometry fingerprints, healthy leaves from those infected with powdery mildew and Rhytisma acerinum were distinguished. Leaves were grated with sandpaper, cut into triangles, and placed before the mass spectrometer, with the addition of a methanol-formic acid solution. Multivariate statistical analysis categorized the samples into three groups. Overall, SPS-MS effectively analyzed leaves with infectious microorganisms, potentially aiding in the creation of fungal identification databanks.


Assuntos
Acer , Fungos , Bases de Dados Factuais , Espectrometria de Massas , Metanol
17.
J Mass Spectrom ; 58(7): e4956, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37401101

RESUMO

Paper spray mass spectrometry (PS-MS) is an ambient ionization technique that allows for rapid and direct mass spectrometry analysis for a wide range of chemical compounds due to its portability, little to no sample preparation, and cost-effective materials. As applications with this technique continue to expand, the identification and discrimination of bacteria at the strain level remain a promising avenue for researchers. Although studies in the past demonstrated the applicability of PS-MS to discriminate bacteria at the strain level, no one has reported the strain-level differentiation of actinobacteria without using solvent for PS-MS. Hence, this study demonstrates that optimization of PS-MS permits the investigation and differentiation of the metabolic profiles of actinobacteria without the need for solvents, diminishing the potential for sample contamination and consequently increasing the versatility of this technique. In doing so, strains of actinobacteria (CAAT P5-21, CAAT P5-16, CAAT 8-25, CAAT P8-92, and CAAT P11-13) were grown and transferred to produce a crude growth medium. The supernatant was used for the PS-MS analyses using a Thermo Scientific LTQ mass spectrometer. Multivariate statistical analysis, including principal component analysis (PCA) and hierarchal cluster analysis (HCA), was employed to chemically distinguish the strains of bacteria. As a result, each strain of actinobacteria could be visually differentiated based on their metabolic profile. These findings demonstrate the practicability of using a liquid medium as an alternative to many other organic solvents when analyzing bacteria, making PS-MS a crucial addition to a microbiologist's research toolkit.


Assuntos
Actinobacteria , Actinobacteria/metabolismo , Solo , Espectrometria de Massas/métodos , Bactérias , Solventes/química , Metaboloma , Papel
18.
Biochim Biophys Acta ; 1811(11): 946-60, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21645635

RESUMO

Desorption electrospray ionization mass spectrometry (DESI-MS) imaging of biological samples allows untargeted analysis and structural characterization of lipids ionized from the near-surface region of a sample under ambient conditions. DESI is a powerful and sensitive MS ionization method for 2D and 3D imaging of lipids from direct and unmodified complex biological samples. This review describes the strengths and limitations of DESI-MS for lipid characterization and imaging together with the technical workflow and a survey of applications. Included are discussions of lipid mapping and biomarker discovery as well as a perspective on the future of DESI imaging.


Assuntos
Imageamento Tridimensional/métodos , Lipídeos/análise , Especificidade de Órgãos , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Humanos , Lipídeos/química
19.
Anal Chem ; 83(14): 5754-61, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21675752

RESUMO

The ambient mass spectrometry technique, desorption electrospray ionization mass spectrometry (DESI-MS), is applied for the rapid identification and spatially resolved relative quantification of chlorophyll degradation products in complex senescent plant tissue matrixes. Polyfunctionalized nonfluorescent chlorophyll catabolites (NCCs), the "final" products of the chlorophyll degradation pathway, are detected directly from leaf tissues within seconds and structurally characterized by tandem mass spectrometry (MS/MS) and reactive-DESI experiments performed in situ. The sensitivity of DESI-MS analysis of these compounds from degreening leaves is enhanced by the introduction of an imprinting technique. Porous polytetrafluoroethylene (PTFE) is used as a substrate for imprinting the leaves, resulting in increased signal intensities compared with those obtained from direct leaf tissue analysis. This imprinting technique is used further to perform two-dimensional (2D) imaging mass spectrometry by DESI, producing well-resolved images of the spatial distribution of NCCs in senescent leaf tissues.


Assuntos
Clorofila/análise , Folhas de Planta/química , Plantas/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Politetrafluoretileno/química , Espectrometria de Massas por Ionização por Electrospray/economia
20.
Chemistry ; 17(10): 2897-902, 2011 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-21284043

RESUMO

Diagnosis of human bladder cancer in untreated tissue sections is achieved by using imaging data from desorption electrospray ionization mass spectrometry (DESI-MS) combined with multivariate statistical analysis. We use the distinctive DESI-MS glycerophospholipid (GP) mass spectral profiles to visually characterize and formally classify twenty pairs (40 tissue samples) of human cancerous and adjacent normal bladder tissue samples. The individual ion images derived from the acquired profiles correlate with standard histological hematoxylin and eosin (H&E)-stained serial sections. The profiles allow us to classify the disease status of the tissue samples with high accuracy as judged by reference histological data. To achieve this, the data from the twenty pairs were divided into a training set and a validation set. Spectra from the tumor and normal regions of each of the tissue sections in the training set were used for orthogonal projection to latent structures (O-PLS) treated partial least-square discriminate analysis (PLS-DA). This predictive model was then validated by using the validation set and showed a 5% error rate for classification and a misclassification rate of 12%. It was also used to create synthetic images of the tissue sections showing pixel-by-pixel disease classification of the tissue and these data agreed well with the independent classification that uses histological data by a certified pathologist. This represents the first application of multivariate statistical methods for classification by ambient ionization although these methods have been applied previously to other MS imaging methods. The results are encouraging in terms of the development of a method that could be utilized in a clinical setting through visualization and diagnosis of intact tissue.


Assuntos
Glicerofosfolipídeos/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Neoplasias da Bexiga Urinária/diagnóstico , Glicerofosfolipídeos/análise , Humanos , Análise Multivariada , Neoplasias da Bexiga Urinária/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA