RESUMO
Limited data exist that comprehensively describe the practical management, in-hospital outcomes, healthcare resource utilization, and rates of post-hospital readmission among patients with submassive and massive pulmonary embolism (PE). Consecutive discharges for acute PE were identified from a single health system over 3 years. Records were audited to confirm presence of acute PE, patient characteristics, disease severity, medical treatment, and PE-related invasive therapies. Rates of in-hospital major bleeding and death, hospital length of stay (LOS), direct costs, and hospital readmission are reported. From January 2016 to December 2018, 371 patients were hospitalized for acute massive or submassive PE. In-hospital major bleeding (12.1%) was common, despite low utilization of systemic thrombolysis (1.8%) or catheter-directed thrombolysis (3.0%). In-hospital death was 10-fold higher among massive PE compared to submassive PE (36.6% vs 3.3%, p < 0.001). Massive PE was more common during hospitalizations not primarily related to venous thromboembolism, including hospitalizations primarily for sepsis or infection (26.8% vs 8.2%, p = 0.001). Overall, the median LOS was 6.0 days (IQR, 3.0-11.0) and the median standardized direct cost of admissions was $10,032 (IQR, $4467-$20,330). Rates of all-cause readmission were relatively high throughout late follow-up but did not differ between PE subgroups. Despite low utilization of thrombolysis, in-hospital bleeding remains a common adverse event during hospitalizations for acute PE. Although massive PE is associated with high risk for in-hospital bleeding and death, those successfully discharged after a massive PE demonstrate similar rates of readmission compared to submassive PE into late follow-up.
Assuntos
Embolia Pulmonar , Terapia Trombolítica , Doença Aguda , Fibrinolíticos/efeitos adversos , Hemorragia/tratamento farmacológico , Mortalidade Hospitalar , Hospitalização , Humanos , Embolia Pulmonar/tratamento farmacológico , Embolia Pulmonar/terapia , Respiração , Estudos Retrospectivos , Terapia Trombolítica/efeitos adversos , Resultado do TratamentoAssuntos
Angina Pectoris , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Oclusão Coronária , Vasos Coronários/diagnóstico por imagem , Adulto , Angina Pectoris/diagnóstico , Angina Pectoris/etiologia , Aneurisma Coronário/complicações , Aneurisma Coronário/diagnóstico , Aneurisma Coronário/fisiopatologia , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Diagnóstico Diferencial , Feminino , Humanos , Poliarterite Nodosa/complicações , Poliarterite Nodosa/diagnósticoRESUMO
Currently, the fully magnetically levitated left ventricular assist device (LVAD) HeartMate 3 (HM3) is the only commercially available device for advanced heart failure (HF) patients. However, the left ventricular (LV) functional and structural changes following mechanical unloading and circulatory support (MCS) with the HM3 have not been investigated. We compared the reverse remodeling induced by the HM3 to older generation continuous-flow LVADs. Chronic HF patients (n = 405) undergoing MCS with HeartWare Ventricular Assist Device (HVAD, n = 115), HM3 (n = 186), and HeartMate II (HM2, n = 104) at four programs were included. Echocardiograms were obtained preimplant and at 1, 3, 6, and 12 months following LVAD implantation. There were no differences in the postimplant serial LV ejection fraction (LVEF) between the devices. The postimplant LV internal diastolic diameter (LVIDd) was significantly lower for HM2 at 3 and 6 months compared with HVAD and HM3. The proportion of patients achieving "cardiac reverse remodeling responder" status (defined as LVEF improvement to ≥40% and LVIDD ≤5.9 cm) was 11.9%, and was similar between devices. HeartMate 3 appears to result in similar cardiac reverse remodeling as older generation CF-LVADs, suggesting that the fully magnetically levitated device technology could provide an effective platform to further study and promote cardiac reverse remodeling.