Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Heart Lung Circ ; 28(10): 1501-1509, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31175017

RESUMO

The usage of ionising radiation in medical investigations and procedures continues to increase. Cardiologists are responsible for a disproportionately high amount of this radiation, and the performance of percutaneous coronary intervention for chronic total occlusions (CTO PCI) often requires particularly high radiation doses. Consequently, both patients and proceduralists are potentially being exposed to harmful doses of radiation. This review discusses the potential dangers of radiation exposure during CTO PCI, as well as techniques to minimise radiation dose to the patient and proceduralist. Specific attention is paid to recent innovations in real-time dose monitoring and X-ray system developments that afford considerable dose savings during routine PCI as well as CTO PCI.


Assuntos
Angiografia Coronária/métodos , Oclusão Coronária/diagnóstico , Gerenciamento Clínico , Intervenção Coronária Percutânea/métodos , Lesões por Radiação/prevenção & controle , Doença Crônica , Oclusão Coronária/cirurgia , Humanos , Doses de Radiação , Exposição à Radiação
2.
Lancet Reg Health West Pac ; 24: 100459, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35538935

RESUMO

Background: Pathology testing and diagnostic imaging together contribute 9% of healthcare's carbon footprint. Whilst the carbon footprint of pathology testing has been undertaken, to date, the carbon footprint of the four most common imaging modalities is unclear. Methods: We performed a prospective life cycle assessment at two Australian university-affiliated health services of five imaging modalities: chest X-ray (CXR), mobile chest X-ray (MCXR), computerised tomography (CT), magnetic resonance imaging (MRI) and ultrasound (US). We included scanner electricity use and all consumables and associated waste, including bedding, imaging contrast, and gloves. Analysis was performed using both attributional and consequential life cycle assessment methods. The primary outcome was the greenhouse gas footprint, measured in carbon dioxide equivalent (CO2e) emissions. Findings: Mean CO2e emissions were 17·5 kg/scan for MRI; 9·2 kg/scan for CT; 0·8 kg/scan for CXR; 0·5 kg/scan for MCXR; and 0·5 kg/scan for US. Emissions from scanners from standby energy were substantial. When expressed as emissions per additional scan (results of consequential analysis) impacts were lower: 1·1 kg/scan for MRI; 1·1 kg/scan for CT; 0·6 kg/scan for CXR; 0·1 kg/scan for MCXR; and 0·1 kg/scan for US, due to emissions from standby power being excluded. Interpretation: Clinicians and administrators can reduce carbon emissions from diagnostic imaging, firstly by reducing the ordering of unnecessary imaging, or by ordering low-impact imaging (X-ray and US) in place of high-impact MRI and CT when clinically appropriate to do so. Secondly, whenever possible, scanners should be turned off to reduce emissions from standby power. Thirdly, ensuring high utilisation rates for scanners both reduces the time they spend in standby, and apportions the impacts of the reduced standby power of a greater number of scans. This therefore reduces the impact on any individual scan, maximising resource efficiency. Funding: Healthy Urban Environments (HUE) Collaboratory of the Maridulu Budyari Gumal Sydney Partnership for Health, Education, Research and Enterprise MBG SPHERE. The National Health and Medical Research Council (NHMRC) PhD scholarship.

3.
Int J Cardiovasc Imaging ; 33(6): 771-778, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28120155

RESUMO

Objectives The aim of this study was to quantify the radiation dose reduction during coronary angiography and percutaneous coronary intervention (PCI) through removal of the anti-scatter grid (ASG), and to assess its impact on image quality in adult patients with a low body mass index (BMI). Methods A phantom with different thicknesses of acrylic was used with a Westmead Test Object to simulate patient sizes and assess image quality. 129 low BMI patients underwent coronary angiography or PCI with or without the ASG in situ. Radiation dose was compared between both patient groups. Results With the same imaging system and a comparable patient population, ASG removal was associated with a 47% reduction in total dose-area product (DAP) (p < 0.001). Peak skin dose was reduced by 54% (p < 0.001). Operator scatter was reduced to a similar degree and was significantly reduced through removal of the ASG. Using an image quality phantom it was demonstrated that image quality remained satisfactory. Conclusions Removal of the ASG is a simple and effective method to significantly reduce radiation dose in coronary angiography and PCI. This was achieved while maintaining adequate diagnostic image quality. Selective removal of the ASG is likely to improve the radiation safety of cardiac angiography and interventions.


Assuntos
Angiografia Coronária/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/instrumentação , Espalhamento de Radiação , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Angiografia Coronária/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/efeitos adversos , Segurança do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Imagens de Fantasmas , Projetos Piloto , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Fatores de Risco , Stents
4.
EuroIntervention ; 12(8): e939-e947, 2016 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-27721210

RESUMO

AIMS: The aim of this study was to evaluate whether a real-time (RT) colour pictorial radiation dose monitoring system reduces patient skin and total radiation dose during coronary angiography and intervention. METHODS AND RESULTS: Patient demographics, procedural variables and radiation parameters were recorded before and after institution of the RT skin dose recording system. Peak skin dose as well as traditionally available measures of procedural radiation dose were compared. A total of 1,077 consecutive patients underwent coronary angiography, of whom 460 also had PCI. Institution of the RT skin dose recording system resulted in a 22% reduction in peak skin dose after accounting for confounding variables. Radiation dose reduction was most pronounced in those having PCI but was also seen over a range of subgroups including those with prior coronary artery bypass surgery, high BMI, and with radial arterial access. This was associated with a significant reduction in the number of patients placed at risk of skin damage. Similar reductions in parameters reflective of total radiation dose were also demonstrated after institution of RT radiation monitoring. CONCLUSIONS: Institution of an RT skin dose recording reduced patient peak skin and total radiation dose during coronary angiography and intervention. Consideration should be given to widespread adoption of this technology.


Assuntos
Cateterismo Cardíaco/métodos , Angiografia Coronária/métodos , Fluoroscopia/métodos , Intervenção Coronária Percutânea/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Pele , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Ponte de Artéria Coronária , Feminino , Artéria Femoral , Reserva Fracionada de Fluxo Miocárdico , Humanos , Análise de Séries Temporais Interrompida , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Artéria Radial , Monitoramento de Radiação/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA