Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
1.
J Magn Reson Imaging ; 58(2): 620-629, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36607254

RESUMO

BACKGROUND: The T2 w sequence is a standard component of a prostate MRI examination; however, it is time-consuming, requiring multiple signal averages to achieve acceptable image quality. PURPOSE/HYPOTHESIS: To determine whether a denoised, single-average T2 sequence (T2 -R) is noninferior to the standard multiaverage T2 sequence (T2 -S) in terms of lesion detection and PI-RADS score assessment. STUDY TYPE: Retrospective. POPULATION: A total of 45 males (age range 60-75 years) who underwent clinically indicated prostate MRI examinations, 21 of whom had pathologically proven prostate cancer. FIELD STRENGTH/SEQUENCE: A 3 T; T2 w FSE, DWI with ADC maps, and dynamic contrast-enhanced images with color-coded perfusion maps. T2 -R images were created from the raw data utilizing a single "average" with iterative denoising. ASSESSMENT: Nine readers randomly assessed complete exams including T2 -R and T2 -S images in separate sessions. PI-RADS version 2.1 was used. All readers then compared the T2 -R and T2 -S images side by side to evaluate subjective preference. An additional detailed image quality assessment was performed by three senior level readers. STATISTICAL TESTS: Generalized linear mixed effects models for differences in lesion detection, image quality features, and overall preference between T2 -R and T2 -S sequences. Intraclass correlation coefficients (ICC) were used to assess reader agreement for all comparisons. A significance threshold of P = 0.05 was used for all statistical tests. RESULTS: There was no significant difference between sequences regarding identification of lesions with PI-RADS ≥3 (P = 0.10) or PI-RADS score (P = 0.77). Reader agreement was excellent for lesion identification (ICC = 0.84). There was no significant overall preference between the two sequences regarding image quality (P = 0.07, 95% CI: [-0.23, 0.01]). Reader agreement was good regarding sequence preference (ICC = 0.62). DATA CONCLUSION: Use of single-average, denoised T2 -weighted images was noninferior in prostate lesion detection or PI-RADS scoring when compared to standard multiaverage T2 -weighted images. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 3.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Pelve/patologia
2.
J Magn Reson Imaging ; 57(1): 308-317, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35512243

RESUMO

BACKGROUND: There is a sparsity of data evaluating outcomes of patients with Liver Imaging Reporting and Data System (LI-RADS) (LR)-M lesions. PURPOSE: To compare overall survival (OS) and progression free survival (PFS) between hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (iCCA) meeting LR-M criteria and to evaluate factors associated with prognosis. STUDY TYPE: Retrospective. SUBJECTS: Patients at risk for HCC with at least one LR-M lesion with histologic diagnosis, from 8 academic centers, yielding 120 patients with 120 LR-M lesions (84 men [mean age 62 years] and 36 women [mean age 66 years]). FIELD STRENGTH/SEQUENCE: A 1.5 and 3.0 T/3D T1 -weighted gradient echo, T2 -weighted fast spin-echo. ASSESSMENT: The imaging categorization of each lesion as LR-M was made clinically by a single radiologist at each site and patient outcome measures were collected. STATISTICAL TESTS: OS, PFS, and potential independent predictors were evaluated by Kaplan-Meier method, log-rank test, and Cox proportional hazard model. A P value of <0.05 was considered significant. RESULTS: A total of 120 patients with 120 LR-M lesions were included; on histology 65 were HCC and 55 were iCCA. There was similar median OS for patients with LR-M HCC compared to patients with iCCA (738 days vs. 769 days, P = 0.576). There were no significant differences between patients with HCC and iCCA in terms of sex (47:18 vs. 37:18, P = 0.549), age (63.0 ± 8.4 vs. 63.4 ± 7.8, P = 0.847), etiology of liver disease (P = 0.202), presence of cirrhosis (100% vs. 100%, P = 1.000), tumor size (4.73 ± 3.28 vs. 4.75 ± 2.58, P = 0.980), method of lesion histologic diagnosis (P = 0.646), and proportion of patients who underwent locoregional therapy (60.0% vs. 38.2%, P = 0.100) or surgery (134.8 ± 165.5 vs. 142.5 ± 205.6, P = 0.913). Using multivariable analysis, nonsurgical compared to surgical management (HR, 4.58), larger tumor size (HR, 1.19), and higher MELD score (HR, 1.12) were independently associated with worse OS. DATA CONCLUSION: There was similar OS in patients with LR-M HCC and LR-M iCCA, suggesting that LR-M imaging features may more closely reflect patient outcomes than histology. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 5.


Assuntos
Neoplasias dos Ductos Biliares , Carcinoma Hepatocelular , Colangiocarcinoma , Neoplasias Hepáticas , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/cirurgia , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Colangiocarcinoma/diagnóstico por imagem , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Ductos Biliares Intra-Hepáticos , Meios de Contraste
3.
Radiology ; 301(1): 123-130, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34374592

RESUMO

Background Reliance on examination reporting of unexpected imaging findings does not ensure receipt of findings or appropriate follow-up. A closed-loop communication system should include provider and patient notifications and be auditable through the electronic health record (EHR). Purpose To report the initial design of and results from using an EHR-integrated unexpected findings navigator (UFN) program that ensures closed-loop communication of unexpected nonemergent findings. Materials and Methods An EHR-integrated UFN program was designed to enable identification and communication of unexpected findings and aid in next steps in findings management. Three navigators (with prior training as radiologic technologists and sonographers) facilitated communication and documentation of results to providers and patients. Twelve months (October 2019 to October 2020) of results were retrospectively reviewed to evaluate patient demographics and program metrics. Descriptive statistics and correlation analysis were performed by using commercially available software. Results A total of 3542 examinations were reported within 12 months, representing 0.5% of all examinations performed (total of 749 649); the median patient age was 62 years (range, 1 day to 98 years; interquartile range, 23 years). Most patients were female (2029 of 3542 [57%]). Almost half of the examinations submitted were from chest radiography and CT (1618 of 3542 [46%]), followed by MRI and CT of the abdomen and pelvis (1123 of 3542 [32%]). The most common unexpected findings were potential neoplasms (391 of 3542 [11%]). The median time between examination performance and patient notification was 12 days (range, 0-136 days; interquartile range, 13 days). A total of 2127 additional imaging studies were performed, and 1078 patients were referred to primary care providers and specialists. Most radiologists (89%, 63 of 71 respondents) and providers (65%, 28 of 43 respondents) found the system useful and used it most frequently during regular business hours. Conclusion An electronic health record-integrated, navigator-facilitated, closed-loop communication program for unexpected radiologic findings led to near-complete success in notification of providers and patients and facilitated the next steps in findings management. © RSNA, 2021 See also the editorial by Safdar in this issue.


Assuntos
Registros Eletrônicos de Saúde/estatística & dados numéricos , Achados Incidentais , Comunicação para Apreensão de Informação/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Adulto Jovem
4.
J Comput Assist Tomogr ; 45(3): 421-426, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33797440

RESUMO

OBJECTIVE: The objective of this study was to assess the impact of tube voltage and image display on the identification of power ports features on anterior-posterior scout images to inform optimal workflow for multidetector computed tomography (MDCT) examinations. MATERIALS AND METHODS: Four ports, representing variable material composition (titanium/silicone), shapes, and computed tomography (CT) markings, were imaged on an adult anthropomorphic chest phantom using a dual-source MDCT at variable peak tube voltages (80, 100, 120, 150, and Sn150 kVp). Images were reviewed at variable image display setting by 5 blinded readers to assess port features of material composition, shape, and text markings as well as overall preferred image quality. RESULTS: Material composition was correctly identified for all ports by all readers across all kilovoltage-peak settings. The identification by shape was more reliable than CT markers for all but one of the ports. CT marker identification was up to 80% for titanium ports at window level settings optimized for metal (window width, 200; window center, -150) and at a soft tissue setting (window width, 400; window center, 40) for silicone ports. Interreader agreement for best image quality per kilovoltage-peak setting was moderate to substantial for 3 ports (k = 0.5-0.62) but only fair for 1 port (k = 0.27). The highest overall rank for image quality was given unanimously to Sn150 kVp for imaging titanium ports and 100 kVp for silicone ports. CONCLUSIONS: Power port identification on MDCT scout images can be optimized with modification of MDCT scout acquisition and display settings based on the main port material.


Assuntos
Tomografia Computadorizada Multidetectores/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tórax/anatomia & histologia , Adulto , Humanos , Tomografia Computadorizada Multidetectores/métodos , Variações Dependentes do Observador , Imagens de Fantasmas , Tórax/diagnóstico por imagem
5.
Radiographics ; 40(2): 354-375, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31951512

RESUMO

Representatives from the Society of Abdominal Radiology Crohn's Disease-Focused Panel, the Society for Pediatric Radiology, the American Gastroenterological Association, and other international experts recently reported consensus recommendations for standardized nomenclature for the interpretation and reporting of CT enterography and MR enterography findings of small bowel Crohn disease. The consensus recommendations included CT enterography and MR enterography bowel wall findings that are associated with Crohn disease, findings that occur with penetrating Crohn disease, and changes that occur in the mesentery related to Crohn disease. Also included were recommended radiology report impression statements that summarize the findings of small bowel Crohn disease at CT enterography and MR enterography. This article, authored by the Society of Abdominal Radiology Crohn's Disease-Focused Panel, illustrates the imaging findings and recommended radiology report impression statements described in the consensus recommendations with examples of CT enterography and MR enterography images. Additional interpretation guidelines for reporting CT enterography and MR enterography examinations are also presented. The recommended standardized nomenclature can be used to generate radiology report dictations that will help guide medical and surgical management for patients with small bowel Crohn disease. Online supplemental material is available for this article. ©RSNA, 2020See discussion on this article by Heverhagen.


Assuntos
Doença de Crohn/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Terminologia como Assunto , Tomografia Computadorizada por Raios X , Humanos
6.
J Comput Assist Tomogr ; 43(1): 18-21, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30015800

RESUMO

PURPOSE: This study aimed to develop an automated, quantitative method to increase the likelihood of identifying and preventing such air-in-oil (AIO) artifact. METHODS: A 1-dimensional radial representation of the 2-dimensional noise power spectrum (NPS) was calculated from AIO artifact images and compared with artifact-free images. A quality control (QC) software program was modified to include measurements of NPS average frequency within the water section of daily phantom scans. Threshold values for each CT system were incorporated into daily QC. RESULTS: Noise power spectrum for AIO artifact images included a large low-frequency peak compared with artifact-free images; NPS average frequencies were 0.197 and 0.319 line pairs per millimeter for AIO artifact and artifact-free images, respectively. Automated QC successfully identified 3 AIO artifacts before detrimental clinical effect occurred. CONCLUSIONS: Serious clinical problems associated with AIO artifact can be detected and avoided by incorporating NPS average frequency measurements of daily phantom images into an automated QC program.


Assuntos
Artefatos , Infarto Cerebral/diagnóstico por imagem , Controle de Qualidade , Tomografia Computadorizada por Raios X/instrumentação , Doença Aguda , Idoso , Ar , Encéfalo/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Óleos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos
8.
AJR Am J Roentgenol ; 210(6): 1266-1272, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29629800

RESUMO

OBJECTIVE: The purpose of this study is to compare visualization rates of the major features covered by Liver Imaging Reporting and Data System (LI-RADS) version 2014 in patients at risk for hepatocellular carcinoma using either gadobenate dimeglumine or gadoxetate disodium IV contrast agent. MATERIALS AND METHODS: This retrospective study included liver MRI examinations performed with either gadobenate dimeglumine or gadoxetate disodium contrast enhancement. Using age, sex, underlying liver disease, and presence of cirrhosis, patients were placed into matched cohorts. All hepatic nodules 1 cm or larger (up to five per subject) were included, resulting in 63 subjects with 130 nodules (median nodule size, 1.9 cm) imaged with gadobenate and 64 subjects with 117 nodules (median nodule size, 2.0 cm) imaged with gadoxetate. Three radiologists reviewed the studies for LI-RADS major features independently. Bootstrap resampling with 10,000 repetitions was used to compare feature detection rates. RESULTS: Arterial phase hyperenhancement was seen in a similar number of nodules with gadobenate dimeglumine (mean, 91.5% [119/130]) and gadoxetate disodium (mean, 88.0% [103/117]) (p = 0.173). Dynamic phase washout was more commonly seen with gadobenate dimeglumine (mean, 60.2% [78.3/130]) than with gadoxetate disodium (mean, 45.3% [53/117]) (p = 0.006). The capsule feature was more often visualized with gadobenate dimeglumine (mean, 50.2% [65.3/130]) than with gadoxetate disodium (mean, 33.3% [39/117]) (p < 0.001). Interreader agreement for arterial phase enhancement and dynamic phase washout was almost perfect for both contrast agents (κ > 0.83). Agreement for the capsule feature was moderate for gadobenate dimeglumine (κ = 0.52) and substantial for gadoxetate disodium (κ = 0.67). CONCLUSION: The rates of visualization of arterial phase hyperenhancement are similar in studies performed with gadobenate dimeglumine and gadoxetate disodium, but dynamic phase washout and capsule appearance are more commonly visualized with gadobenate dimeglumine.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Gadolínio DTPA/administração & dosagem , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Neoplasias Hepáticas/patologia , Masculino , Meglumina/administração & dosagem , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
J Comput Assist Tomogr ; 42(2): 197-203, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28991065

RESUMO

OBJECTIVE: This study aimed to determine potential radiation dose reduction of contrast-enhanced computed tomography (CECT) for imaging necrotizing pancreatitis (NP) using a noise addition tool. METHODS: Eighty-four patients were identified with at least 1 abdominopelvic CECT for NP within a 2-year period. Sixty consecutive scans were selected as reference radiation dose data sets. A noise addition software was used to simulate 4 data sets of increased noise. Readers rated confidence for identifying (i) anatomic structures, (ii) complications of NP, and (iii) diagnostic acceptability. Noise and dose levels were identified at acceptability threshold where observer scores were statistically indistinguishable from full-dose computed tomographies. RESULTS: Observers' perception of image tasks decreased progressively with increasing noise (P < 0.05). Acceptability and statistical analysis indicated that noise can be increased from 10 to 25 HU corresponding to an 84% reduction in dose without change in observer perception (P < 0.05). CONCLUSIONS: Higher image noise levels may be tolerated in CECT in patients with NP.


Assuntos
Meios de Contraste , Pancreatite Necrosante Aguda/diagnóstico por imagem , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem
10.
Radiology ; 282(2): 361-368, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27509544

RESUMO

Purpose To determine, in a multicenter double-blinded placebo-controlled trial, whether maximal hepatic arterial phase breath-holding duration is affected by gadoxetate disodium administration. Materials and Methods Institutional review board approval was obtained for this prospective multi-institutional HIPAA-compliant study; written informed consent was obtained from all subjects. At three sites, a total of 44 volunteers underwent a magnetic resonance (MR) imaging examination in which images were acquired before and dynamically after bolus injection of gadoxetate disodium, normal saline, and gadoterate meglumine, administered in random order in a single session. The technologist and volunteer were blinded to the agent. Arterial phase breath-holding duration was timed after each injection, and volunteers reported subjective symptoms. Heart rate (HR) and oxygen saturation were monitored. Images were independently analyzed for motion artifacts by three radiologists. Arterial phase breath-holding duration and motion artifacts after each agent were compared by using the Mann-Whitney U test and the McNemar test. Factors affecting the above outcomes were assessed by using a univariate, multivariable model. Results Arterial phase breath holds were shorter after gadoxetate disodium (mean, 32 seconds ± 19) than after saline (mean, 40 seconds ± 17; P < .001) or gadoterate meglumine (43 seconds ± 21, P < .001) administration. In 80% (35 of 44) of subjects, arterial phase breath holds were shorter after gadoxetate disodium than after both saline and gadoterate meglumine. Three (7%) of 44 volunteers had severe arterial phase motion artifacts after gadoxetate disodium administration, one (2%; P = .62) had them after gadoterate meglumine administration, and none (P = .25) had them after saline administration. HR and oxygen saturation changes were not significantly associated with contrast agent. Conclusion Maximal hepatic arterial phase breath-holding duration is reduced after gadoxetate disodium administration in healthy volunteers, and reduced breath-holding duration is associated with motion artifacts. © RSNA, 2016.


Assuntos
Meios de Contraste/administração & dosagem , Meios de Contraste/farmacocinética , Gadolínio DTPA/administração & dosagem , Gadolínio DTPA/farmacocinética , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Suspensão da Respiração , Método Duplo-Cego , Feminino , Voluntários Saudáveis , Humanos , Injeções Intravenosas , Fígado/irrigação sanguínea , Masculino , Meglumina/administração & dosagem , Meglumina/farmacocinética , Compostos Organometálicos/administração & dosagem , Compostos Organometálicos/farmacocinética , Estudos Prospectivos
11.
J Magn Reson Imaging ; 46(3): 783-792, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28083902

RESUMO

PURPOSE: To identify demographic and imaging features in magnetic resonance imaging (MRI) that are associated with upgrade of Liver Imaging Reporting and Data System (LI-RADS) category 4 (LR-4) observations to category 5 (LR-5), and to assess their effects on risk of upgrade and time to upgrade. MATERIALS AND METHODS: Institutional Review Board approval was obtained for this retrospective, dual-institution Health Insurance Portability and Accountability Act (HIPAA)-compliant study. Radiologists reviewed 1.5T and 3T MRI examinations for 181 LR-4 observations in 139 patients, as well as follow-up computed tomography (CT) and MRI examinations and treatment. A stepwise multivariate Cox proportional hazards model analysis was performed to identify predictive risk factors for upgrade to LR-5, including patient demographics and LI-RADS imaging features. Overall cumulative risk of upgrade was calculated by using the Kaplan-Meier method. The cumulative risks were compared in the presence/absence of significant predictive risk factors using the log-rank test. RESULTS: The independent significant predictive risk factors in the 56 LR-4 observations that upgraded to LR-5 were mild-moderate T2 hyperintensity (P < 0.001; hazard ratio = 1.84), growth (P < 0.001; hazard ratio = 3.71), and hepatitis C infection (P = 0.02; hazard ratio = 1.69). The overall 6-month cumulative risk of upgrade was 32.7%. The 6-month cumulative risk rate was significantly higher in the presence of T2 hyperintensity (P = 0.03; 48.1% vs. 25.4%). CONCLUSION: For LR-4 observations, mild-moderate T2 hyperintensity, threshold growth, and hepatitis C infection are associated with significantly higher risk of upgrade to LR-5. Although mild-moderate T2 hyperintensity was the most useful risk factor for predicting upgrade, actual risk level was only mildly elevated, and the risk of upgrade associated with LR-4 observations is similar across subtypes. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 5 J. MAGN. RESON. IMAGING 2017;46:783-792.


Assuntos
Hepatopatias/diagnóstico por imagem , Hepatopatias/patologia , Sistemas de Informação em Radiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença
12.
AJR Am J Roentgenol ; 209(6): W360-W364, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28834451

RESUMO

OBJECTIVE: The purpose of this study is to describe a specific type of blunt traumatic mesenteric injury called a bucket-handle tear, review its varied CT appearances, and discuss the role of CT in its detection. CONCLUSION: A bucket-handle mesenteric injury is a rare but life-threatening blunt traumatic injury that can be difficult to detect prospectively on CT and for which delays in diagnosis and definitive surgical management can result in poor outcomes.


Assuntos
Traumatismos Abdominais/diagnóstico por imagem , Mesentério/diagnóstico por imagem , Mesentério/lesões , Tomografia Computadorizada por Raios X/métodos , Ferimentos não Penetrantes/diagnóstico por imagem , Humanos
13.
J Comput Assist Tomogr ; 41(3): 412-416, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28505623

RESUMO

PURPOSE: This study aimed to assess the effect of a low-rank denoising algorithm on quantitative magnetic resonance imaging-based measures of liver fat and iron. MATERIALS AND METHODS: This was an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant, retrospective analysis of 42 consecutive subjects who were imaged at 3T using a multiecho gradient echo sequence that was reconstructed using the multistep adaptive fitting algorithm to obtain quantitative proton density fat fraction (PDFF) and R2* maps (original maps). A patch-wise low-rank denoising algorithm was then applied, and PDFF and R2* maps were created (denoised maps). Three readers independently rated the PDFF maps in terms of vessel and liver edge sharpness and image noise using a 5-point scale. Two other readers independently measured mean and standard deviation of PDFF and R2* values for the original and denoised maps; values were compared using intraclass correlation coefficients (ICCs) and mean difference analyses. RESULTS: Qualitatively, the denoised maps were preferred by all 3 readers based on image noise (P < 0.001) and by 2 of 3 readers based on vessel edge sharpness (P < 0.001-0.99). No reader had a significant preference regarding liver edge sharpness (P = 0.16-0.48). Quantitatively, agreement was near perfect between the original and denoised maps for PDFF (ICC = 0.995) and R2* (ICC = 0.995) values. Mean quantitative values obtained from the original and denoised maps were similar for liver PDFF (7.6 ± 7.7% vs 7.7 ± 7.8%; P = 0.63) and R2* (52.9 ± 40.3s vs 52.8 ± 41.1 s, P = 0.74). CONCLUSIONS: Applying the low-rank denoising algorithm to liver fat and iron quantification reduces image noise in PDFF and R2* maps without adversely affecting mean quantitative values or subjective image quality.


Assuntos
Adipócitos , Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Ferro/metabolismo , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Avaliação como Assunto , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Fígado/metabolismo , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
14.
Ann Surg Oncol ; 23(4): 1090-5, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26572755

RESUMO

BACKGROUND: Despite advances in cross-sectional imaging, chemotherapeutic dosing for isolated limb infusion (ILI) in melanoma is currently calculated through cumbersome and potentially imprecise manual measurements. The primary objective of this study was to examine the feasibility of using computed tomography (CT) to calculate limb volume, its concordance with manual measurement, and its ability to predict clinical response and toxicity in patients undergoing ILI. METHODS: A retrospective analysis of all patients undergoing lower extremity ILI at Duke University Medical Center between 2003 and 2014 was performed. Data pertaining to manually measured limb volume, chemotherapeutic dosing, and patient outcome was obtained. CT-based measurements of limb volume were performed in all patients for whom imaging was available and subsequently compared with manually measured values. RESULTS: CT data were sufficient for measurement in 73 patients. The mean measurement time was 4.61 ± 2.13 min. Although average CT-based measurements were 1.20 L higher in the case of lower limbs, they correlated well with those obtained manually (r (2) = 0.90). Unlike manual measurement, patients with complete responses to chemotherapy had smaller limb volumes than those with disease progression as measured by CT (9.3 vs. 10.7 L; p = .038). Patients suffering grade 3 and 4 toxicities also had statistically lower limb volumes as measured by CT than those who did not (p < .05). CONCLUSIONS: CT-based limb volume measurement is feasible for chemotherapy dosing in patients undergoing ILI for melanoma and has predictive value with respect to clinical response and toxicity.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Quimioterapia do Câncer por Perfusão Regional , Extremidade Inferior/patologia , Melanoma/patologia , Neoplasias Cutâneas/patologia , Tomografia Computadorizada por Raios X/métodos , Dactinomicina/administração & dosagem , Progressão da Doença , Estudos de Viabilidade , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Extremidade Inferior/diagnóstico por imagem , Melanoma/diagnóstico por imagem , Melanoma/tratamento farmacológico , Melfalan/administração & dosagem , Estadiamento de Neoplasias , Prognóstico , Estudos Retrospectivos , Neoplasias Cutâneas/diagnóstico por imagem , Neoplasias Cutâneas/tratamento farmacológico
15.
J Magn Reson Imaging ; 43(5): 1073-81, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26469796

RESUMO

PURPOSE: To determine whether triple-arterial phase acquisition with fluoroscopic triggering can provide both well-timed early and late hepatic arterial phase (HAP) images more frequently than when using a fixed-time delay during gadoxetic acid-enhanced magnetic resonance imaging (MRI). MATERIALS AND METHODS: Written informed consent was obtained for this Institutional Review Board (IRB)-approved prospective, Health Insurance Portability and Accountability Act (HIPAA)-compliant study. Ninety patients underwent gadoxetic acid-enhanced MRI at 3T with a single-breath-hold triple-arterial phase acquisition using either a fixed-time delay (n = 45) or fluoroscopic triggering injection protocol (n = 45). Three radiologists, blinded to method of timing and other data, independently determined whether well-timed early or late HAP were obtained for each arterial phase image set and assessed for transient severe motion (TSM). Rates of successful HAP acquisitions and of TSM were compared between the two protocols using χ(2) or Fisher's exact test. RESULTS: The rate of successful acquisition of late HAP images was similar in the two groups (93% [42/45] for fixed-time delay vs. 98% [44/45] for fluoroscopic triggering, P = 0.62). There was a trend toward higher rates of successful acquisition of both early and late HAP images in the fluoroscopic triggering group (69% [31/45] vs. 49% [22/45], P = 0.05). TSM occurred in five patients (6% [5/90]) and at similar frequencies in the two groups (2% [1/45] vs. 9% [4/45], P = 0.36). CONCLUSION: Triple-arterial phase acquisition with fluoroscopic triggering tended to provide both well-timed early and late HAP images more frequently than when using a fixed-time delay during gadoxetic acid-enhanced MRI.


Assuntos
Fluoroscopia/métodos , Artéria Hepática/patologia , Fígado/patologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Gadolínio DTPA/química , Artéria Hepática/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Variações Dependentes do Observador
16.
Radiology ; 274(1): 141-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25162310

RESUMO

PURPOSE: To determine, in a dual-center setting, whether patients who experience transient severe motion ( TSM transient severe motion ) in the arterial phase during gadoxetate disodium-enhanced magnetic resonance (MR) imaging are at higher risk for a subsequent episode of TSM transient severe motion than patients who do not have TSM transient severe motion during initial gadoxetate disodium administration. MATERIALS AND METHODS: Institutional review board approval was obtained for this retrospective, multi-institutional HIPAA-compliant study. The requirement for informed consent was waived. One hundred seventy patients each underwent two MR imaging examinations with bolus injection of gadoxetate disodium at one of two sites. Three radiologists reviewed the examinations at each site for TSM transient severe motion , based on severe arterial phase motion, despite minimal motion in the other dynamic phases. The occurrence rate of TSM transient severe motion in the second examination was compared between patients who had TSM transient severe motion in their first examination and those who did not by using the χ(2) or Fisher exact test, as appropriate. Relative risks and 95% confidence intervals ( CI confidence interval s) were calculated. RESULTS: TSM transient severe motion rates in second examinations were significantly higher for patients who had TSM transient severe motion in their first examination: site 1, 67% (six of nine) vs 4% (three of 69) (P < .0001); site 2, 60% (three of five) vs 6% (five of 87) (P < .005); and both sites, 64% (nine of 14) vs 5% (eight of 156) (P < .0001). Relative risks were 15 for site 1 (95% CI confidence interval : 5, 51), 10 for site 2 (95% CI confidence interval : 3, 32), and 13 for both sites (95% CI confidence interval : 6, 27). CONCLUSION: Patients who experience TSM transient severe motion during gadoxetate disodium-enhanced MR imaging are at significantly and substantially higher risk for TSM transient severe motion in the next gadoxetate disodium-enhanced examination compared with patients who do not have TSM transient severe motion during their initial gadoxetate disodium administration.


Assuntos
Abdome , Artefatos , Gadolínio DTPA , Imageamento por Ressonância Magnética/métodos , Respiração , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Movimento (Física) , Compostos Organometálicos , Estudos Retrospectivos
17.
J Magn Reson Imaging ; 42(2): 305-14, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25371354

RESUMO

PURPOSE: To determine the rate of agreement between the Organ Procurement and Transplant Network (OPTN) and Liver Imaging Reporting and Data System (LI-RADS) classifications for hypervascular liver nodules at least 1 cm in diameter, and for patient eligibility for hepatocellular/MELD (Model for Endstage Liver Disease) exception points. MATERIALS AND METHODS: This retrospective study was approved by our Institutional Review Board and was compliant with the Health Insurance Portability and Accountability Act. The requirement for informed consent was waived. This study included 200 hypervascular hepatocellular nodules at least 1 cm in diameter on computed tomography (CT) or magnetic resonance imaging (MRI) examinations in 105 patients with chronic liver disease. Three radiologists blinded to clinical data independently evaluated nodule characteristics, including washout, capsule, size, and size on prior examination. Based on those characteristics, nodules were automatically classified as definite hepatocellular carcinoma (HCC) or not definite HCC using both the OPTN and LI-RADS classifications. Using these classifications and the Milan criteria, each examination was determined to be "below transplant criteria," "within transplant criteria," or "beyond transplant criteria." Agreement was assessed between readers and classification systems, using Fleiss' kappa, intraclass correlation coefficients (ICCs), and simple proportions. RESULTS: Interreader agreement was moderate for nodule features (κ = 0.59-0.69) and nodule classification (0.66-0.69). The two systems were in nearly complete agreement on nodule category assignment (98.7% [592/600]) and patient eligibility for transplant exemption priority (99.4% [313/315]). A few discrepancies occurred for the nodule feature of growth (1.3% [8/600]) and for nodule category assignment (1.3% [8/600]). CONCLUSION: Agreement between the OPTN and LI-RADS classifications is very strong for categorization of hypervascular liver nodules at least 1 cm in diameter, and for patient eligibility for hepatocellular/MELD exception points. Interreader variability is much higher than intersystem variability.


Assuntos
Carcinoma Hepatocelular/classificação , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/classificação , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/normas , Neovascularização Patológica/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Transplante de Fígado/normas , Pessoa de Meia-Idade , Neovascularização Patológica/classificação , Variações Dependentes do Observador , Sistemas de Informação em Radiologia/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Estatística como Assunto , Obtenção de Tecidos e Órgãos/normas , Estados Unidos
18.
Am J Obstet Gynecol ; 213(5): 693.e1-6, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26215327

RESUMO

OBJECTIVE: The purpose of this study was to determine the diagnostic performance of magnetic resonance imaging (MRI) in the diagnosis of acute appendicitis during pregnancy in a multiinstitutional study. STUDY DESIGN: In this multicenter retrospective study, the cases of pregnant women who underwent MRI evaluation of abdominal or pelvic pain and who had clinical suspicion of acute appendicitis between June 1, 2009, and July 31, 2014, were reviewed. All MRI examinations with positive findings for acute appendicitis were confirmed with surgical pathologic information. Sensitivity, specificity, negative predictive values, and positive predictive values were calculated. Receiver operating characteristic curves were generated, and area under the curve analysis was performed for each participating institution. RESULTS: Of the cases that were evaluated, 9.3% (66/709) had MRI findings of acute appendicitis. Sensitivity, specificity, accuracy, positive predictive value, and negative predictive values were 96.8%, 99.2%, 99.0%, 92.4%, and 99.7%, respectively. There was no statistically significant difference between centers that were included in the study (pair-wise probability values ranged from 0.12-0.99). CONCLUSION: MRI is useful and reproducible in the diagnosis of suspected acute appendicitis during pregnancy.


Assuntos
Apendicite/diagnóstico , Imageamento por Ressonância Magnética , Complicações na Gravidez/diagnóstico , Adolescente , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Gravidez , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
19.
AJR Am J Roentgenol ; 204(5): 994-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25905933

RESUMO

OBJECTIVE: The purposes of this article are to illustrate the CT appearance of gastrointestinal vasoocclusive crisis in patients with sickle cell disease (SCD), highlight potential complications, and review other conditions that may have similar findings. CONCLUSION: The gastrointestinal vasoocclusive crisis in SCD is rare but can result in potentially life-threatening ischemia and death. Knowledge of the spectrum of CT features of the gastrointestinal vasoocclusive crisis is important in making the diagnosis and potentially preventing complications.


Assuntos
Anemia Falciforme/complicações , Gastroenteropatias/diagnóstico por imagem , Gastroenteropatias/etiologia , Isquemia/diagnóstico por imagem , Isquemia/etiologia , Tomografia Computadorizada por Raios X/métodos , Vasoconstrição , Anemia Falciforme/fisiopatologia , Meios de Contraste , Diagnóstico Diferencial , Gastroenteropatias/fisiopatologia , Humanos , Isquemia/fisiopatologia
20.
AJR Am J Roentgenol ; 205(2): 421-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26204296

RESUMO

OBJECTIVE: Many radiologists are unfamiliar with the new antithrombogenic medications and how to modify patient management before nonvascular percutaneous procedures performed in a radiology department. In this article, we review the indications for use, mechanism of action, pharmacokinetics, dosing, and recommendations for periprocedural management of patients using these medications. CONCLUSION: To improve patient safety, radiologists involved in percutaneous procedures should have knowledge of the antithrombotics that will be encountered routinely in clinical practice.


Assuntos
Anticoagulantes/farmacologia , Endoscopia , Hemorragia/etiologia , Hemorragia/prevenção & controle , Inibidores da Agregação Plaquetária/farmacologia , Radiografia Intervencionista , Anticoagulantes/administração & dosagem , Anticoagulantes/farmacocinética , Humanos , Segurança do Paciente , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/farmacocinética , Guias de Prática Clínica como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA