Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 163
Filtrar
1.
N Engl J Med ; 382(2): 130-139, 2020 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-31733182

RESUMO

BACKGROUND: Subclinical leaflet thickening and reduced leaflet motion of bioprosthetic aortic valves have been documented by four-dimensional computed tomography (CT). Whether anticoagulation can reduce these phenomena after transcatheter aortic-valve replacement (TAVR) is not known. METHODS: In a substudy of a large randomized trial, we randomly assigned patients who had undergone successful TAVR and who did not have an indication for long-term anticoagulation to a rivaroxaban-based antithrombotic strategy (rivaroxaban [10 mg] plus aspirin [75 to 100 mg] once daily) or an antiplatelet-based strategy (clopidogrel [75 mg] plus aspirin [75 to 100 mg] once daily). Patients underwent evaluation by four-dimensional CT at a mean (±SD) of 90±15 days after randomization. The primary end point was the percentage of patients with at least one prosthetic valve leaflet with grade 3 or higher motion reduction (i.e., involving >50% of the leaflet). Leaflet thickening was also assessed. RESULTS: A total of 231 patients were enrolled. At least one prosthetic valve leaflet with grade 3 or higher motion reduction was found in 2 of 97 patients (2.1%) who had scans that could be evaluated in the rivaroxaban group, as compared with 11 of 101 (10.9%) in the antiplatelet group (difference, -8.8 percentage points; 95% confidence interval [CI], -16.5 to -1.9; P = 0.01). Thickening of at least one leaflet was observed in 12 of 97 patients (12.4%) in the rivaroxaban group and in 33 of 102 (32.4%) in the antiplatelet group (difference, -20.0 percentage points; 95% CI, -30.9 to -8.5). In the main trial, the risk of death or thromboembolic events and the risk of life-threatening, disabling, or major bleeding were higher with rivaroxaban (hazard ratios of 1.35 and 1.50, respectively). CONCLUSIONS: In a substudy of a trial involving patients without an indication for long-term anticoagulation who had undergone successful TAVR, a rivaroxaban-based antithrombotic strategy was more effective than an antiplatelet-based strategy in preventing subclinical leaflet-motion abnormalities. However, in the main trial, the rivaroxaban-based strategy was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than the antiplatelet-based strategy. (Funded by Bayer; GALILEO-4D ClinicalTrials.gov number, NCT02833948.).


Assuntos
Valva Aórtica/fisiopatologia , Aspirina/farmacologia , Clopidogrel/farmacologia , Inibidores do Fator Xa/farmacologia , Próteses Valvulares Cardíacas , Inibidores da Agregação Plaquetária/farmacologia , Rivaroxabana/farmacologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/efeitos dos fármacos , Valva Aórtica/patologia , Aspirina/efeitos adversos , Aspirina/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Clopidogrel/uso terapêutico , Quimioterapia Combinada , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/uso terapêutico , Feminino , Tomografia Computadorizada Quadridimensional , Hemorragia/induzido quimicamente , Humanos , Análise de Intenção de Tratamento , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Rivaroxabana/efeitos adversos , Rivaroxabana/uso terapêutico , Tromboembolia/etiologia , Tromboembolia/mortalidade
2.
Catheter Cardiovasc Interv ; 101(6): 1134-1143, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37036268

RESUMO

OBJECTIVE: To determine the prognostic impact of coronary artery disease (CAD) in patients randomized to bivalirudin or unfractionated heparin (UFH) during transcatheter aortic valve replacement (TAVR). BACKGROUND: CAD is a common comorbidity among patients undergoing TAVR and studies provide conflicting data on its prognostic impact. METHODS: The Bivalirudin on Aortic Valve Intervention Outcomes-3 (BRAVO-3) randomized trial compared the use of bivalirudin versus UFH in 802 high-surgical risk patients undergoing transfemoral TAVR for severe symptomatic aortic stenosis. Patients were stratified according to the presence or absence of history of CAD as well as periprocedural anticoagulation. The coprimary endpoints were net adverse cardiac events (NACE; a composite of all-cause mortality, myocardial infarction, stroke, or major bleeding) and major Bleeding Academic Research Consortium (BARC) bleeding ≥3b at 30 days postprocedure. RESULTS: Among 801 patients, 437 (54.6%) had history of CAD of whom 223 (51.0%) received bivalirudin. There were no significant differences in NACE (adjusted odds ratio [OR]: 1.04; 95% confidence interval [CI]: 0.69-1.58) or BARC ≥ 3b bleeding (adjusted OR: 0.84; 95% CI: 0.51-1.39) in patients with vs without CAD at 30 days. Among CAD patients, periprocedural use of bivalirudin was associated with similar NACE (OR: 0.80; 95% CI: 0.47-1.35) and BARC ≥ 3b bleeding (OR: 0.64; 95% CI: 0.33-1.25) compared with UFH, irrespective of history of CAD (p-interaction = 0.959 for NACE; p-interaction = 0.479 for major bleeding). CONCLUSION: CAD was not associated with a higher short-term risk of NACE or major bleeding after TAVR. Periprocedural anticoagulation with bivalirudin did not show any advantage over UFH in patients with and without CAD.


Assuntos
Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Humanos , Heparina/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Antitrombinas/efeitos adversos , Resultado do Tratamento , Hirudinas/efeitos adversos , Hemorragia/induzido quimicamente , Fragmentos de Peptídeos/efeitos adversos , Proteínas Recombinantes/efeitos adversos
3.
Biomarkers ; 27(3): 278-285, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35112976

RESUMO

BACKGROUND: Soluble urokinase plasminogen activator receptor (suPAR) is an emerging biomarker associated with anatomical CAD burden and cardiovascular outcomes including myocardial infarction (MI) and death. We aimed to validate previous findings of the prognostic value of suPAR and to evaluate its diagnostic potential for functional relevant CAD (fCAD). METHODS: Consecutive patients with suspected fCAD were enrolled. Adjudication of fCAD was performed blinded to suPAR concentrations by myocardial perfusion single-photon emission tomography (MPI-SPECT) and coronary angiography. Prognostic outcome measures included all-cause death, cardiovascular death, and incident MI during 2-year follow-up. RESULTS: Among consecutive 968 patients, suPAR concentrations were higher in patients with fCAD compared to those without (3.45 vs. 3.20 ng/mL, p = 0.007), but did not provide acceptable diagnostic accuracy (area under the curve [AUC]: 0.56, 95%CI 0.52-0.60). SuPAR correlated with high-sensitivity cardiac-troponin T (Spearman's rho (ρ) 0.393, p < 0.001), NT-proBNP (ρ = 0.327, p < 0.001), age (ρ = 0.364, p < 0.001) and very weakly with coronary atherosclerosis (ρ = 0.123, p < 0.001). Prognostic discrimination of suPAR was moderate for cardiovascular death (AUC = 0.72, 95%CI 0.62-0.81) and all-cause death (AUC = 0.72, 95%CI 0.65-0.79) at 2-years. SuPAR remained a significant predictor for all-cause death in multivariable Cox regression (HR = 1.96, p = 0.001). CONCLUSIONS: SuPAR was an independent predictor of all-cause death, without diagnostic utility for fCAD. CLINICAL TRIAL REGISTRATION: NCT01838148.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Biomarcadores , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Humanos , Infarto do Miocárdio/diagnóstico , Prognóstico , Estudos Prospectivos , Receptores de Ativador de Plasminogênio Tipo Uroquinase
4.
Lancet ; 396(10261): 1504-1510, 2020 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-33091360

RESUMO

BACKGROUND: In the treatment of de-novo coronary small vessel disease, drug-coated balloons (DCBs) are non-inferior to drug-eluting stents (DESs) regarding clinical outcome up to 12 months, but data beyond 1 year is sparse. We aimed to test the long-term efficacy and safety of DCBs regarding clinical endpoints in an all-comer population undergoing percutaneous coronary intervention. METHODS: In this prespecified long-term follow-up of a multicentre, randomised, open-label, non-inferiority trial, patients from 14 clinical sites in Germany, Switzerland, and Austria with de-novo lesions in coronary vessels <3 mm and an indication for percutaneous coronary intervention were randomly assigned 1:1 to DCB or second-generation DES and followed over 3 years for major adverse cardiac events (ie, cardiac death, non-fatal myocardial infarction, and target-vessel revascularisation [TVR]), all-cause death, probable or definite stent thrombosis, and major bleeding (Bleeding Academic Research Consortium bleeding type 3-5). Analyses were performed on the full analysis set according to the modified intention-to-treat principle. Dual antiplatelet therapy was recommended for 1 month after DCB and 6 months after DES with stable symptoms, but 12 months with acute coronary syndromes. The study is registered with ClinicalTrials.gov, NCT01574534 and is ongoing. FINDINGS: Between April 10, 2012, and Feb 1, 2017, of 883 patients assessed, 758 (86%) patients were randomly assigned to the DCB group (n=382) or the DES group (n=376). The Kaplan-Meier estimate of the rate of major adverse cardiac events was 15% in both the DCB and DES groups (hazard ratio [HR] 0·99, 95% CI 0·68-1·45; p=0·95). The two groups were also very similar concerning the single components of adverse cardiac events: cardiac death (Kaplan-Meier estimate 5% vs 4%, HR 1·29, 95% CI 0·63-2·66; p=0·49), non-fatal myocardial infarction (both Kaplan-Meier estimate 6%, HR 0·82, 95% CI 0·45-1·51; p=0·52), and TVR (both Kaplan-Meier estimate 9%, HR 0·95, 95% CI 0·58-1·56; p=0·83). Rates of all-cause death were very similar in DCB versus DES patients (both Kaplan-Meier estimate 8%, HR 1·05, 95% CI 0·62-1·77; p=0·87). Rates of probable or definite stent thrombosis (Kaplan-Meier estimate 1% vs 2%; HR 0·33, 95% CI 0·07-1·64; p=0·18) and major bleeding (Kaplan-Meier estimate 2% vs 4%, HR 0·43, 95% CI 0·17-1·13; p=0·088) were numerically lower in DCB versus DES, however without reaching significance. INTERPRETATION: There is maintained efficacy and safety of DCB versus DES in the treatment of de-novo coronary small vessel disease up to 3 years. FUNDING: Swiss National Science Foundation, Basel Cardiovascular Research Foundation, and B Braun Medical.


Assuntos
Angioplastia Coronária com Balão/normas , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/normas , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/mortalidade , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 97(5): 876-884, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32886851

RESUMO

OBJECTIVES: To investigate 4-year, post-transcatheter aortic valve implantation (TAVI) survival and predictors of survival by sex, in a real-world cohort that underwent transfemoral TAVI with SAPIEN 3 transcatheter heart valve. BACKGROUND: Previous TAVI investigations of first-generation devices demonstrated an early- to mid-term survival advantage in women compared with men. METHODS: SOURCE 3 (SAPIEN 3 Aortic Bioprosthesis European Outcome) is a post-approval, multicentre, observational registry. Patients (N = 1,694, 49.2% women, age 81.7 ± 6.7 years) with severe aortic stenosis and high surgical risk (logistic EuroSCORE 17.8%) underwent TAVI between 2014 and 2015. Kaplan-Meier event estimates were used to determine mortality by sex. Predictors of overall mortality were identified using a cox multivariate proportional hazard model. RESULTS: At 4 years, women had lower all-cause mortality than men (36.0 vs 39.7%; p = .0911; HR: 0.87 [95% CI: 0.75-1.02]). No difference was observed for cardiac mortality between women 24.2% and men 24.7% (p = .76; HR: 0.97 [95% CI: 0.79-1.19]). When adjusted for baseline characteristics (age, height, weight, NYHA functional class, renal insufficiency, EuroScore, and tricuspid regurgitation), sex had no impact on mortality. CONCLUSIONS: In this large, real-world cohort, all-cause mortality trended lower in women than men at 4 years post TAVI; however, several baseline factors, but not sex, were predictors of mortality. No difference between sexes was observed for cardiovascular mortality.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 98(6): E870-E880, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33909348

RESUMO

OBJECTIVES: To determine the prognostic impact of anemia in patients randomized to bivalirudin or unfractionated heparin (UFH) during transcatheter aortic valve replacement (TAVR). BACKGROUND: Whether the periprocedural use of bivalirudin as compared with UFH in anemic patients undergoing TAVR has an impact on outcomes remains unknown. METHODS: The BRAVO-3 trial compared the use of bivalirudin versus UFH in 802 high risk patients undergoing transfemoral TAVR for severe symptomatic aortic stenosis. Patients were stratified according to the presence (defined as hemoglobin levels <13 g/dl in men and <12 g/dl in women) or absence of anemia. The primary outcomes were net adverse cardiac events (NACE; a composite of all-cause mortality, myocardial infarction, stroke, or bleeding) and major bleeding (Bleeding Academic Research Consortium ≥3b) at 30 days. RESULTS: Among 798 patients with available baseline hemoglobin levels, 427 (54%) were anemic of whom 221 (52%) received bivalirudin. There were no significant differences in NACE and major bleeding at 30 days between patients with and without anemia, irrespective of the type of anticoagulant used (pinteraction  = 0.71 for NACE, pinteraction  = 1.0 for major bleeding). However, anemic patients had a higher risk of major vascular complications (adjusted OR 2.43, 95% CI 1.42-4.16, p = 0.001), and acute kidney injury (adjusted OR 1.74, 95% CI 1.16-2.59, p = 0.007) compared to non-anemic patients at 30 days. CONCLUSIONS: Anemia was not associated with a higher risk of NACE or major bleeding at 30 days after TAVR without modification of the treatment effects of periprocedural anticoagulation with bivalirudin versus UFH.


Assuntos
Anemia , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Anemia/diagnóstico , Antitrombinas , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Heparina , Humanos , Masculino , Nitrilas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Ann Intern Med ; 172(3): 175-185, 2020 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-31905377

RESUMO

Background: The optimal noninvasive method for surveillance in symptomatic patients with stable coronary artery disease (CAD) is unknown. Objective: To apply a novel approach using very low concentrations of high-sensitivity cardiac troponin I (hs-cTnI) for exclusion of inducible myocardial ischemia in symptomatic patients with CAD. Design: Prospective diagnostic cohort study. (ClinicalTrials.gov: NCT01838148). Setting: University hospital. Patients: 1896 consecutive patients with CAD referred with symptoms possibly related to inducible myocardial ischemia. Measurements: Presence of inducible myocardial ischemia was adjudicated using myocardial perfusion imaging with single-photon emission computed tomography, as well as coronary angiography and fractional flow reserve measurements where available. Staff blinded to adjudication measured circulating hs-cTn concentrations. An hs-cTnI cutoff of 2.5 ng/L, derived previously in mostly asymptomatic patients with CAD, was assessed. Predefined target performance criteria were at least 90% negative predictive value (NPV) and at least 90% sensitivity for exclusion of inducible myocardial ischemia. Sensitivity analyses were based on measurements with an hs-cTnT assay and an alternative hs-cTnI assay with even higher analytic sensitivity (limit of detection, 0.1 ng/L). Results: Overall, 865 patients (46%) had inducible myocardial ischemia. The hs-cTnI cutoff of 2.5 ng/L provided an NPV of 70% (95% CI, 64% to 75%) and a sensitivity of 90% (CI, 88% to 92%) for exclusion of inducible myocardial ischemia. No hs-cTnI cutoff reached both performance characteristics predefined as targets. Similarly, using the alternative assays for hs-cTnI or hs-cTnT, no cutoff achieved the target performance: hs-cTnT concentrations less than 5 ng/L yielded an NPV of 66% (CI, 59% to 72%), and hs-cTnI concentrations less than 2 ng/L yielded an NPV of 68% (CI, 62% to 74%). Limitation: Data were generated in a large single-center diagnostic study using central adjudication. Conclusion: In symptomatic patients with CAD, very low hs-cTn concentrations, including hs-cTnI concentrations less than 2.5 ng/L, do not generally allow users to safely exclude inducible myocardial ischemia. Primary Funding Source: European Union, Swiss National Science Foundation, Kommission für Technologie und Innovation (Innosuisse), Swiss Heart Foundation, Cardiovascular Research Foundation Basel, University of Basel, University Hospital Basel, Roche, Abbott, and Singulex.


Assuntos
Doença da Artéria Coronariana/sangue , Isquemia Miocárdica/sangue , Isquemia Miocárdica/diagnóstico , Troponina I/sangue , Troponina T/sangue , Idoso , Biomarcadores/sangue , Estudos de Coortes , Angiografia Coronária , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Valor Preditivo dos Testes , Tomografia Computadorizada de Emissão de Fóton Único
8.
Curr Cardiol Rep ; 23(11): 173, 2021 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-34648080

RESUMO

PURPOSE OF REVIEW: In the interventional treatment of coronary artery disease, new-generation drug-eluting stents (DES) currently are the standard treatment. In addition, drug-coated balloons (DCB) are a well-established option for the treatment of in-stent restenosis in both bare-metal stents (BMS) and DES, where DCBs deliver an antiproliferative drug without the necessity of re-implanting a stent. Since the field of use for DCB has increasingly been extended to other indications such as de novo lesions in small vessel disease (SVD), a review of literature may be useful. RECENT FINDINGS: Recent randomized trial data show good efficacy and safety for DCB in de novo lesions, especially in small coronary arteries, and confirm long-term clinical efficacy and safety up to three years. DCB are an attractive and safe option in the treatment of de novo lesions in SVD.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Stents Farmacológicos , Preparações Farmacêuticas , Doença da Artéria Coronariana/tratamento farmacológico , Humanos
9.
Catheter Cardiovasc Interv ; 96(3): E377-E386, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31808295

RESUMO

OBJECTIVES: This study sought to investigate the clinical outcomes of patients with and without peripheral artery disease (PAD) in the BRAVO-3 trial with respect to the effect of bivalirudin versus unfractionated heparin (UFH). BACKGROUND: PAD is found frequently in patients undergoing transcatheter aortic valve replacement (TAVR) and is reported to confer an increased risk of adverse events. It is unknown whether patients with and without PAD may demonstrate a differential response to bivalirudin versus UFH. METHODS: BRAVO-3 was a randomized multicenter trial comparing transfemoral TAVR with bivalirudin versus UFH (31 centers, n = 802). Major adverse cardiovascular events (MACE) were a composite of 30-day death, myocardial infarction, or cerebrovascular accidents (CVA). Net adverse cardiovascular events (NACE) were a composite of major bleeding or MACE. RESULTS: The total cohort included 119 patients with PAD. Vascular complications occurred significantly more frequently in patients with PAD both in-hospital (25.2 vs. 16.7%; OR 1.68) and at 30 days (29.4 vs. 17.3%; OR 1.99). No significant differences were observed regarding mortality, NACE, MACE, major bleeding or CVA with bivalirudin versus UFH among patients with or without PAD. In patients with PAD, bivalirudin was associated with an increased risk of minor vascular complications at 30 days. CONCLUSIONS: Patients with PAD undergoing transfemoral TAVR did not exhibit an increased risk of any major adverse events, according to the procedural anticoagulant randomization. However, patients treated with Bivalirudin had significantly higher rates of minor vascular complications.


Assuntos
Anticoagulantes/uso terapêutico , Antitrombinas/uso terapêutico , Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico , Artéria Femoral , Heparina/uso terapêutico , Fragmentos de Peptídeos/uso terapêutico , Doença Arterial Periférica/complicações , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Antitrombinas/efeitos adversos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Transtornos Cerebrovasculares/etiologia , Transtornos Cerebrovasculares/mortalidade , Europa (Continente) , Feminino , Hemorragia/induzido quimicamente , Hemorragia/mortalidade , Heparina/efeitos adversos , Hirudinas/efeitos adversos , Mortalidade Hospitalar , Humanos , Masculino , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , América do Norte , Fragmentos de Peptídeos/efeitos adversos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/mortalidade , Punções , Ensaios Clínicos Controlados Aleatórios como Assunto , Proteínas Recombinantes/efeitos adversos , Proteínas Recombinantes/uso terapêutico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
10.
Cardiology ; 145(12): 757-765, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32818933

RESUMO

BACKGROUND: The association between alcohol consumption and the occurrence of coronary heart disease is well described in the literature, while data regarding the impact of regular alcohol consumption on in-hospital outcomes in the setting of acute coronary syndrome (ACS) are lacking. We aimed to evaluate the impact of self-reported alcohol consumption on in-hospital outcomes in patients with ACS. METHODS: Data derived from patients enrolled between 2007 and 2019 in the Acute Myocardial Infarction in Switzerland (AMIS) Plus registry were retrospectively analyzed. Patients were stratified based on alcohol drinking pattern. Primary outcome was all-cause in-hospital mortality, while secondary outcomes were set as incidence of major adverse cardiac and cerebrovascular events (MACCEs). Outcome comparisons according to quantity of daily alcohol intake were also performed. RESULTS: Records concerning alcohol consumption were available in 25,707 patients; 5,298 of them (21%) fulfilled the criteria of regular alcohol consumption. Regular drinkers were predominantly male, younger, smokers, more comorbid and with a worse clinical presentation as compared with abstainers/occasional drinkers. Daily alcohol intake was reported in 4,059 (77%) of these patients (regular drinkers). Among them, 2,640 were light drinkers (≤2 drinks/day) and 1,419 heavy drinkers (>2 drinks/day). In-hospital mortality and MACCEs of heavy drinkers were significantly higher compared with those of light drinkers (5.4 vs. 3.3% and 7.0 vs. 4.4%, both p = 0.001). When tested together with Global Registry of Acute Coronary Events risk score parameters, heavy alcohol consumption was independently associated with in-hospital mortality (p = 0.004). CONCLUSIONS: Our results support that heavy alcohol consumption is an independent predictor of in-hospital mortality in patients presenting with ACS.


Assuntos
Síndrome Coronariana Aguda , Consumo de Bebidas Alcoólicas , Infarto do Miocárdio , Hábitos , Hospitais , Humanos , Masculino , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Suíça
11.
Lancet ; 392(10150): 849-856, 2018 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-30170854

RESUMO

BACKGROUND: Drug-coated balloons (DCB) are a novel therapeutic strategy for small native coronary artery disease. However, their safety and efficacy is poorly defined in comparison with drug-eluting stents (DES). METHODS: BASKET-SMALL 2 was a multicentre, open-label, randomised non-inferiority trial. 758 patients with de-novo lesions (<3 mm in diameter) in coronary vessels and an indication for percutaneous coronary intervention were randomly allocated (1:1) to receive angioplasty with DCB versus implantation of a second-generation DES after successful predilatation via an interactive internet-based response system. Dual antiplatelet therapy was given according to current guidelines. The primary objective was to show non-inferiority of DCB versus DES regarding major adverse cardiac events (MACE; ie, cardiac death, non-fatal myocardial infarction, and target-vessel revascularisation) after 12 months. The non-inferiority margin was an absolute difference of 4% in MACE. This trial is registered with ClinicalTrials.gov, number NCT01574534. FINDINGS: Between April 10, 2012, and February 1, 2017, 382 patients were randomly assigned to the DCB group and 376 to DES group. Non-inferiority of DCB versus DES was shown because the 95% CI of the absolute difference in MACE in the per-protocol population was below the predefined margin (-3·83 to 3·93%, p=0·0217). After 12 months, the proportions of MACE were similar in both groups of the full-analysis population (MACE was 7·5% for the DCB group vs 7·3% for the DES group; hazard ratio [HR] 0·97 [95% CI 0·58-1·64], p=0·9180). There were five (1·3%) cardiac-related deaths in the DES group and 12 (3·1%) in the DCB group (full analysis population). Probable or definite stent thrombosis (three [0·8%] in the DCB group vs four [1·1%] in the DES group; HR 0·73 [0·16-3·26]) and major bleeding (four [1·1%] in the DCB group vs nine [2·4%] in the DES group; HR 0·45 [0·14-1·46]) were the most common adverse events. INTERPRETATION: In small native coronary artery disease, DCB was non-inferior to DES regarding MACE up to 12 months, with similar event rates for both treatment groups. FUNDING: Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Basel Cardiovascular Research Foundation, and B Braun Medical AG.


Assuntos
Angioplastia Coronária com Balão/métodos , Materiais Revestidos Biocompatíveis/uso terapêutico , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Prospectivos
13.
J Vasc Surg ; 70(1): 216-223, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30922743

RESUMO

OBJECTIVE: Noncardiac surgery early after coronary stenting has been associated with a high rate of stent thrombosis and catastrophic outcomes. However, those outcomes were mostly seen when dual antiplatelet therapy (DAPT) was discontinued before surgery. This observational study sought to estimate the risk of major adverse cardiac events (MACEs) after femoral artery repair following recent stent-percutaneous coronary intervention under continued DAPT and to explore potential risk factors. We suspect that in this setting, the risk of MACEs is lower than previously reported. METHODS: This retrospective cohort study included all consecutive patients who underwent femoral artery repair because of puncture site complications (bleeding or occlusion) within 28 days after coronary stenting at a tertiary referral center in Switzerland from 2005 to 2015. The primary end point consisted of the MACEs death, cardiac arrest, stent thrombosis, and myocardial infarction. RESULTS: There were 12,960 patients who underwent coronary stenting. Seventy patients (0.5%) required repair of the femoral vessels, which was performed under continued DAPT in all cases. Eight patients (11.4%; 95% confidence interval [CI], 5.4-21.8) experienced a total of 17 MACEs within 30 days after surgery, including 5 deaths (7.1%; 95% CI, 2.7-16.6). Factors significantly associated with postoperative MACEs were cardiogenic shock on admission before coronary stenting (hazard ratio, 6.9; 95% CI, 1.8-29.6; P = .035) and limb ischemia as an indication for surgery compared with bleeding (hazard ratio, 10.5; 95% CI, 2.7-40.7; P = .008). CONCLUSIONS: In our series, femoral artery repair under DAPT for access site complications early after stent-percutaneous coronary intervention is associated with only a modest MACE rate and therefore a much better outcome than previously reported.


Assuntos
Arteriopatias Oclusivas/cirurgia , Cateterismo Periférico/efeitos adversos , Artéria Femoral/cirurgia , Hemorragia/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Arteriopatias Oclusivas/etiologia , Arteriopatias Oclusivas/mortalidade , Cateterismo Periférico/mortalidade , Quimioterapia Combinada , Feminino , Hemorragia/induzido quimicamente , Hemorragia/etiologia , Hemorragia/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/efeitos adversos , Punções , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Suíça , Fatores de Tempo , Resultado do Tratamento
14.
Eur J Clin Invest ; 49(6): e13112, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30925205

RESUMO

BACKGROUND: The phenomenon of exercise-induced left ventricular dysfunction (LVD) is incompletely understood. Better understanding of its prevalence and determinants might help to address the current potential oversimplification of the relation between physical activity and cardiac health in patients with coronary artery disease (CAD). METHODS: We prospectively assessed the prevalence and determinants of exercise-induced LVD in patients with stable CAD and normal LV function at rest undergoing bicycle rest/stress myocardial perfusion imaging single-photon emission computed tomography (MPI-SPECT). Exercise-induced LVD was defined as a relevant (5% or more) drop in left ventricular ejection fraction after maximal exercise. High-sensitivity cardiac troponin I/T (Hs-cTnI/T) and N-terminal probrain natriuretic peptide (NT-proBNP) concentrations were measured before exercise to quantify cardiomyocyte injury and hemodynamic cardiac stress, respectively. RESULTS: Among 317 patients, exercise-induced LVD was present in 83 (26%) patients. Exercise-induced LVD was associated with the extent of exercise-inducible myocardial ischaemia as well as transient ischaemic dilatation. Still, 43% of patients developing exercise-induced LVD did not have functionally relevant CAD. Neither baseline characteristics, nor the quantification of the extent of cardiomyocyte injury and hemodynamic cardiac stress using hs-cTnI/T and NT-proBNP concentrations, respectively, allowed predicting exercise-induced LVD. CONCLUSION: One out of four patients with stable CAD develops exercise-induced LVD after bicycle exercise test. While the extent of exercise-inducible myocardial ischaemia is a predictor, other still unrecognized mechanisms also seem to play a major role, as nearly half of all patients with exercise-induced LVD do not have functionally relevant CAD.

15.
Catheter Cardiovasc Interv ; 93(7): 1374-1381, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-31116908

RESUMO

BACKGROUND/OBJECTIVE: Prostar XL (PS) and ProGlide (PG) are common vascular closure devices (VCD) used in TAVR via transfemoral vascular approach. The impact of these VCD on vascular and bleeding complications remains unclear. METHODS: The BRAVO-3 trial randomized 802 patients undergoing transfemoral TAVR. We stratified patients according to type of VCD used and examined the 30-day incidence of major or minor vascular complications, major bleeding (BARC ≥3b), AKI and major adverse cardiac and cerebrovascular events (MACCE; death, myocardial infarction or stroke). RESULTS: A total of 746 (93%) patients were treated with either PS (n = 352, 47%) or PG (n = 394, 53%) VCD, without significant differences in successful deployment rate (PS 322 [91.2%] vs. PG 373 [94.2%] respectively, p = .20). PG was associated with a significantly lower incidence of major or minor vascular complications, compared to PS (adjusted OR: 0.54; 95% CI: 0.37-0.80; p < .01). Rates of acute kidney injury were also lower with the PG device. There was no significant difference between bleeding, MACCE, and death. CONCLUSIONS: Compared to PS, the PG VCD was associated with a lower rate of major or minor vascular complications and lower rates of AKI after transfemoral TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Dispositivos de Oclusão Vascular , Doenças Vasculares/prevenção & controle , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Canadá , Desenho de Equipamento , Europa (Continente) , Feminino , Hemorragia/etiologia , Hemorragia/mortalidade , Técnicas Hemostáticas/efeitos adversos , Técnicas Hemostáticas/mortalidade , Humanos , Masculino , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Doenças Vasculares/etiologia , Doenças Vasculares/mortalidade
16.
BMC Cardiovasc Disord ; 19(1): 226, 2019 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-31619181

RESUMO

BACKGROUND: The new generation thinner-strut silicon carbide (SiC) coated cobalt chromium (CoCr) bare-metal stents (BMS) are designed to accelerate rapid endothelialisation and reduce thrombogenicity when implanted in coronary arteries. However, smaller studies suggest higher rates of symptomatic restenosis in patients receiving the newer generation BMS. We investigated the efficacy of a newer generation ultrathin strut silicon-carbide coated cobalt-chromium (CoCr) BMS (SCC-BMS) as compared to an older thin-strut uncoated CoCr BMS (UC-BMS) in patients presenting with coronary artery disease requiring stenting of large vessels (≥3.0 mm). METHODS: All patients randomized to SCC- (n = 761) or UC-BMS (n = 765) in the two BASKET-PROVE trials were included. Design, patients, interventions and follow-up were similar between trials except differing regimens of dual antiplatelet therapy. The primary endpoint was clinically driven target-vessel revascularization within 24 months. Safety endpoints of cardiac death, non-fatal myocardial infarction (MI), and definite/probable stent thrombosis (ST) were also assessed. We used inverse probability weighted proportional hazards Cox regressions adjusting for known confounders. RESULTS: Demographics, clinical presentation, and risk factors were comparable between the groups, but patients receiving SCC-BMS underwent less complex procedures. The risk for clinically driven TVR was increased om the SCC-BMS group compared to the UC-BMS group (cumulative incidence, 10.6% vs. 8.4%; adjusted relative hazard [HR], 1.49 [95% CI, 1.05-2.10]). No differences in safety endpoints were detected, cardiac death (1.6% vs. 2.8%; HR, 0.62 [CI, 0.30-1.27]), non-fatal MI (3.2% vs. 2.5%; HR, 1.56 [CI, 0.83-2.91]), and definite/probable ST (0.8% vs. 1.1%; HR, 1.17 [CI, 0.39-3.50]). Differences in strut thickness between the two stents did not explain the association between stent type and clinically driven TVR. CONCLUSIONS: In patients requiring stenting of large coronary arteries, use of the newer generation SCC-BMS was associated with a higher risk of clinically driven repeat revascularization compared to the UC-BMS with no signs of an offsetting safety benefit.


Assuntos
Compostos Inorgânicos de Carbono , Ligas de Cromo , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/instrumentação , Compostos de Silício , Stents , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/mortalidade , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Clin Chem ; 64(11): 1596-1606, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30097496

RESUMO

BACKGROUND: We aimed to directly compare high-sensitivity cardiac troponin I (hs-cTnI) and high-sensitivity cardiac troponin T (hs-cTnT) in the detection of functionally relevant coronary artery disease (fCAD). METHODS: Consecutive patients referred with clinical suspicion of fCAD and no structural heart disease other than coronary artery disease were included. The presence of fCAD was based on rest/stress myocardial perfusion single-photon emission computed tomography/computed tomography and coronary angiography. hs-cTnI and hs-cTnT concentrations were measured in a blinded fashion. Diagnostic accuracy was quantified using the area under the ROC curve (AUC) and evaluated both for uniform use in all patients and for sex-specific use in women and men separately. The prognostic end point was major adverse cardiac events (MACEs; cardiovascular death or myocardial infarction) within 2 years. For the prognostic performance, we used a multivariable model comparison with the Akaike information criterion (AIC). RESULTS: fCAD was detected in 613 of 2062 patients (29.7%) overall, 112 of 664 of women (16.9%), and 501 of 1398 of men (35.8%). hs-cTnI and hs-cTnT had comparable diagnostic accuracy when assessed for uniform use in all patients (AUC, 0.68 vs 0.66; P = 0.107) and separately in women (AUC, 0.68 vs 0.63; P = 0.068) and men (AUC, 0.65 vs 0.64; P = 0.475). However, women required lower rule-out cutoffs to achieve high sensitivity, and men needed higher rule-in cutoffs to achieve high specificity. hs-cTnI and hs-cTnT were strongly and independently associated with MACE within 2 years (P < 0.001), with comparable prognostic accuracies by the AIC. CONCLUSIONS: hs-cTnI and hs-cTnT provide moderate and comparable diagnostic accuracy. Sex-specific cutoffs may be preferred. The prognostic utility of both troponins is comparable.


Assuntos
Doença da Artéria Coronariana/sangue , Troponina I/sangue , Troponina T/sangue , Área Sob a Curva , Biomarcadores/sangue , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Diagnóstico Precoce , Feminino , Humanos , Masculino , Prognóstico , Estudos Prospectivos , Sensibilidade e Especificidade , Fatores Sexuais , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único
18.
Catheter Cardiovasc Interv ; 91(5): 867-873, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28722266

RESUMO

OBJECTIVES: To compare mid-term outcomes between patients undergoing proximal left anterior descending artery (LAD) percutaneous coronary intervention (PCI) with second generation drug-eluting stent (DES) or bare-metal stent (BMS). BACKGROUND: PCI with BMS and first-generation DES have shown to be safe options for the treatment of proximal LAD stenosis, however associated with considerable reintervention rates. Overall, second-generation DES has proven to be superior to BMS and first-generation DES, nevertheless, its effect for proximal LAD PCI has not previously been reported. METHODS: We analyzed 2-year outcomes of 1,100 patients from the BASKET-PROVE I and II trials, referred for proximal LAD PCI with second generation DES (n = 680) or BMS (n = 420). RESULTS: The cumulative 2-year incidence of major adverse cardiac events (MACE, composite of cardiac death, myocardial infarction (MI) and target vessel revascularization (TVR)) was lower in second generation DES than in BMS treated patients (7.3% vs. 12.3%; HR 0.57, 95% CI 0.39/0.85), mainly driven by a reduced rate of TVR (3.7% vs. 10.0%; HR 0.35, CI 0.21/0.58). No difference was found in cardiac death (1.9% vs. 1.9%; HR 1.01, CI 0.42/2.44) and MI (4.4% vs. 4.7%; HR 0.93, CI 0.53/1.64). The benefit of DES use seemed to be more prominent in female patients with a reduction in MACE (P for interaction = 0.025). CONCLUSIONS: In patients with proximal LAD stenosis, treatment with second-generation DES was associated with reduced 2-year rates of adverse cardiac events and TVR compared to BMS, with reintervention rates similar to those earlier reported from bypass surgery.


Assuntos
Doença da Artéria Coronariana/cirurgia , Estenose Coronária/cirurgia , Stents Farmacológicos , Metais , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Quimioterapia Combinada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/uso terapêutico , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 90(6): 1027-1037, 2017 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-28493641

RESUMO

BACKGROUND: Prior studies have suggested that patients with atrial fibrillation (AF) undergoing transcatheter aortic valve replacement (TAVR) are at higher risk for adverse cardiovascular events. Whether procedural bivalirudin compared with unfractionated heparin (UFH) has a beneficial effect on early outcomes in these patients is unknown. We examined for the effect of baseline or new-onset AF within 30 days of TAVR and explored for the effect of bivalirudin versus UFH by AF status, on 30-day outcomes from the BRAVO 3 trial. METHODS: The BRAVO-3 trial multicenter randomized trial included 802 patients undergoing transfemoral TAVR randomized to bivalirudin or UFH. We compared AF and no-AF groups and examined for 30-day Bleeding Academic Research Consortium type ≥3b bleeding, major vascular complications and all ischemic endpoints. Adjusted outcomes were analyzed using logistic regression methods. RESULTS: Of the study population, 41.4% (n = 332) patients had baseline or new-onset AF within 30 days of TAVR, whereas 58.6% (n = 470) had no AF. Patients with AF had greater prevalence of renal dysfunction, lower left ventricular ejection fraction, and higher euroSCORE I compared with their counterparts without AF. Among AF and no-AF patients, there were no significant baseline differences between bivalirudin and UFH groups. At 30 days the incidence of death (6.0 vs. 4.5%, P = 0.324) and stroke (3.9 vs. 2.6%, P = 0.274) was similar in AF vs. no-AF patients. However, new-onset AF (n = 38) was associated with significantly greater crude risk of 30-day stroke compared with no AF (HR 4.49, 95% CI 1.37-14.67). Regardless of AF status, there were no differences in 30-day death (P-int = 0.652) or stroke (P-int = 0.066) by anticoagulation type. CONCLUSIONS: Prior or new-onset AF is noted in more than one-third of patients undergoing transfemoral TAVR. Despite greater baseline comorbidities than non-AF patients, AF was not associated with significantly higher risk of adjusted 30-day outcomes. In the BRAVO 3 trial, early outcomes were similar regardless of anticoagulant strategy in each group.


Assuntos
Estenose da Valva Aórtica/cirurgia , Fibrilação Atrial/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Causas de Morte/tendências , Comorbidade/tendências , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Estados Unidos/epidemiologia
20.
Circulation ; 131(1): 74-81, 2015 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-25411159

RESUMO

BACKGROUND: Biodegradable-polymer drug-eluting stents (BP-DES) were developed to be as effective as second-generation durable-polymer drug-eluting stents (DP-DES) and as safe >1 year as bare-metal stents (BMS). Thus, very late stent thrombosis (VLST) attributable to durable polymers should no longer appear. METHODS AND RESULTS: To address these early and late aspects, 2291 patients presenting with acute or stable coronary disease needing stents ≥3.0 mm in diameter between April 2010 and May 2012 were randomly assigned to biolimus-A9-eluting BP-DES, second-generation everolimus-eluting DP-DES, or thin-strut silicon-carbide-coated BMS in 8 European centers. All patients were treated with aspirin and risk-adjusted doses of prasugrel. The primary end point was combined cardiac death, myocardial infarction, and clinically indicated target-vessel revascularization within 2 years. The combined secondary safety end point was a composite of VLST, myocardial infarction, and cardiac death. The cumulative incidence of the primary end point was 7.6% with BP-DES, 6.8% with DP-DES, and 12.7% with BMS. By intention-to-treat BP-DES were noninferior (predefined margin, 3.80%) compared with DP-DES (absolute risk difference, 0.78%; -1.93% to 3.50%; P for noninferiority 0.042; per protocol P=0.09) and superior to BMS (absolute risk difference, -5.16; -8.32 to -2.01; P=0.0011). The 3 stent groups did not differ in the combined safety end point, with no decrease in events >1 year, particularly VLST with BP-DES. CONCLUSIONS: In large vessel stenting, BP-DES appeared barely noninferior compared with DP-DES and more effective than thin-strut BMS, but without evidence for better safety nor lower VLST rates >1 year. Findings challenge the concept that durable polymers are key in VLST formation. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01166685.


Assuntos
Implantes Absorvíveis , Anti-Inflamatórios/uso terapêutico , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Polímeros , Sirolimo/análogos & derivados , Implantes Absorvíveis/efeitos adversos , Idoso , Anti-Inflamatórios/efeitos adversos , Aspirina/uso terapêutico , Stents Farmacológicos/efeitos adversos , Everolimo , Feminino , Humanos , Estimativa de Kaplan-Meier , Estudos Longitudinais , Masculino , Metais , Pessoa de Meia-Idade , Piperazinas/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Polímeros/efeitos adversos , Cloridrato de Prasugrel , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Método Simples-Cego , Sirolimo/efeitos adversos , Sirolimo/uso terapêutico , Stents , Suíça , Tiofenos/uso terapêutico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA