Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Eur Radiol ; 25(6): 1598-606, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25515204

RESUMO

OBJECTIVES: To determine the radiation dose, image quality, and clinical utility of non-enhanced chest CT with spectral filtration. METHODS: We retrospectively analysed 25 non-contrast chest CT examinations acquired with spectral filtration (tin-filtered Sn100 kVp spectrum) compared to 25 examinations acquired without spectral filtration (120 kV). Radiation metrics were compared. Image noise was measured. Contrast-to-noise-ratio (CNR) and figure-of-merit (FOM) were calculated. Diagnostic confidence for the assessment of various thoracic pathologies was rated by two independent readers. RESULTS: Effective chest diameters were comparable between groups (P = 0.613). In spectral filtration CT, median CTDIvol, DLP, and size-specific dose estimate (SSDE) were reduced (0.46 vs. 4.3 mGy, 16 vs. 141 mGy*cm, and 0.65 vs. 5.9 mGy, all P < 0.001). Spectral filtration CT had higher image noise (21.3 vs. 13.2 HU, P < 0.001) and lower CNR (47.2 vs. 75.3, P < 0.001), but was more dose-efficient (FOM 10,659 vs. 2,231/mSv, P < 0.001). Diagnostic confidence for parenchymal lung disease and osseous pathologies was lower with spectral filtration CT, but no significant difference was found for pleural pathologies, pulmonary nodules, or pneumonia. CONCLUSIONS: Non-contrast chest CT using spectral filtration appears to be sufficient for the assessment of a considerable spectrum of thoracic pathologies, while providing superior dose efficiency, allowing for substantial radiation dose reduction. KEY POINTS: • Spectral filtration enables non-contrast chest CT with very high dose efficiency. • This approach reduces CTDI vol , DLP, and SSDE (effective chest diameter 28 cm). • Lung nodules, pneumonia, and pleural pathologies can be assessed with uncompromised confidence.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pneumopatias/diagnóstico por imagem , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
Eur Radiol ; 23(4): 991-6, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23064715

RESUMO

OBJECTIVE: The evaluation of breast implants for rupture is currently the domain of ultrasound and MRI, while mammography is of very limited diagnostic value. Recently, specific visualisation of silicone has become feasible using dual-energy CT. Our objective was to evaluate whether it is feasible to identify silicone in breast implants by dual-energy CT and to reliably diagnose or rule out ruptures. METHODS: Seven silicone breast implant specimens were examined on dual-source CT at 100- and 140-kV tube potential with a 0.8-mm tin filter (collimation 128 × 0.6 mm, current-time products 165 and 140 mAsref with modulation, rotation time 0.28 s, pitch 0.55). Two patients scheduled for implant removal or replacement were examined with identical parameters. RESULTS: The silicone of the implant specimens showed a strong dual-energy signal. In one patient, both implants were intact, while a rupture was identified in the other patient. Ultrasound, MRI, surgical findings and histology confirmed the dual-energy CT diagnosis. CONCLUSION: Dual-energy CT may serve as an alternative technique for speedy evaluation of silicone breast implants. Specific clinical studies are required to determine the diagnostic accuracy and define indications for this technique.


Assuntos
Implante Mamário/métodos , Implantes de Mama , Mamografia/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Silicones/análise , Tomografia Computadorizada por Raios X/métodos , Análise de Falha de Equipamento/métodos , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Eur Radiol ; 22(10): 2110-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22610534

RESUMO

OBJECTIVE: To show the feasibility of dual-energy CT (DECT) and dynamic CT for ventilation imaging of the paranasal sinuses in a nasal cast. METHODS: In a first trial, xenon gas was administered to a nasal cast with a laminar flow of 7 L/min. Dynamic CT acquisitions of the nasal cavity and the sinuses were performed. This procedure was repeated with pulsating xenon flow. Local xenon concentrations in the different compartments of the model were determined on the basis of the enhancement levels. In a second trial, DECT measurements were performed both during laminar and pulsating xenon administration and the xenon concentrations were quantified directly. RESULTS: Neither with dynamic CT nor DECT could xenon-related enhancement be detected in the sinuses during laminar airflow. Using pulsating flow, dynamic imaging showed a xenon wash-in and wash-out in the sinuses that followed a mono-exponential function with time constants of a few seconds. Accordingly, DECT revealed xenon enhancement in the sinuses only after pulsating xenon administration. CONCLUSION: The feasibility of xenon-enhanced DECT for ventilation imaging was proven in a nasal cast. The superiority of pulsating gas flow for the administration of gas or aerosolised drugs to the paranasal sinuses was demonstrated. KEY POINTS : • Ventilation of the paranasal sinuses is poorly understood. • Dual-energy CT ventilation imaging has been explored using phantom simulation. • Xenon can be seen in the paranasal sinuses using pulsating xenon flow. • Dual-energy CT uses a lower radiation dose compared with dynamic ventilation CT.


Assuntos
Seios Paranasais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Estudos de Viabilidade , Modelos Anatômicos , Respiração , Xenônio
4.
Eur Radiol ; 22(2): 269-78, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21913059

RESUMO

OBJECTIVE: To correlate a Dual Energy (DE)-based visual perfusion defect scoring system with established CT-based and clinical parameters of pulmonary embolism (PE) severity. METHODS: In 63 PE patients, DE perfusion maps were visually scored for perfusion defects (P-score). Vascular obstruction was quantified using the Mastora score. Both scores were correlated with short-axis diameters of the right and left ventricle, their ratio (RV/LV ratio), width of the pulmonary trunk, a number of clinical parameters and each other. Univariate and multivariate analyses were performed. Times to generate both scores were recorded. RESULTS: After univariate and multivariate analysis, a significant (p < 0.05) correlation with the P-score was shown for the Mastora score (r = 0.65), RV/LV ratio (r = 0.47), width of the pulmonary trunk (r = 0.26), troponin I (r = 0.43) and PaO(2) (r = -0.50). For the left ventricular diameter, only univariate analysis showed a significant correlation. Mastora score correlated significantly with RV/LV ratio (r = 0.36), width of the pulmonary trunk (r = 0.27), PaO(2) (r = -0.41) and troponin I (r = 0.37). Mean time for generating the P-score was significantly shorter than for the Mastora score. CONCLUSIONS: A DE-based P-score correlates with a number of parameters of PE severity. It might be easier and faster to perform than some traditional CT scoring methods for vascular obstruction.


Assuntos
Sangue/metabolismo , Cardiologia/métodos , Pulmão/metabolismo , Oxigênio/metabolismo , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Direita/metabolismo , Idoso , Meios de Contraste/farmacologia , Feminino , Humanos , Iohexol/análogos & derivados , Iohexol/farmacologia , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Perfusão
5.
AJR Am J Roentgenol ; 199(5 Suppl): S3-8, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23097165

RESUMO

OBJECTIVE: In dual-energy CT (DECT), two CT datasets are acquired with different x-ray spectra. These spectra are generated using different tube potentials, partially also with additional filtration at 140 kVp. Spectral information can also be resolved by layer detectors or quantum-counting detectors. Several technical approaches-that is, sequential acquisition, rapid voltage switching, dual-source CT (DSCT), layer detector, quantum-counting detector-offer different spectral contrast and dose efficiency. Various postprocessing algorithms readily provide clinically relevant spectral information. CONCLUSION: DECT offers the possibility to exploit spectral information for diagnostic purposes. There are different technical approaches, all of which have inherent advantages and disadvantages, especially regarding spectral contrast and dose efficiency. There are numerous clinical applications of DECT that are easily accessible with specific postprocessing algorithms.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Desenho de Equipamento
6.
Radiology ; 260(3): 689-98, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21846761

RESUMO

PURPOSE: To determine the feasibility of computed tomography (CT)-based dynamic myocardial perfusion imaging for the detection of hemodynamically significant coronary artery stenosis, as defined with fractional flow reserve (FFR). MATERIALS AND METHODS: Institutional review board approval and informed patient consent were obtained before patient enrollment in the study. The study was HIPAA compliant. Subjects who were suspected of having or were known to have coronary artery disease underwent electrocardiographically triggered dynamic stress myocardial perfusion imaging. FFR measurement was performed within all main coronary arteries with a luminal narrowing of 50%-85%. Estimated myocardial blood flow (MBF) was derived from CT images by using a model-based parametric deconvolution method for 16 myocardial segments and was related to hemodynamically significant coronary artery stenosis with an FFR of 0.75 or less in a blinded fashion. Conventional measures of diagnostic accuracy were derived, and discriminatory power analysis was performed by using logistic regression analysis. RESULTS: Of 36 enrolled subjects, 33 (mean age, 68.1 years ± 10 [standard deviation]; 25 [76%] men, eight [24%] women) completed the study protocol. An MBF cut point of 75 mL/100 mL/min provided the highest discriminatory power (C statistic, 0.707; P <.001). While the diagnostic accuracy of CT for the detection of anatomically significant coronary artery stenosis (>50%) was high, it was low for the detection of hemodynamically significant stenosis (positive predictive value [PPV] per coronary segment, 49%; 95% confidence interval [CI]: 36%, 60%). With use of estimated MBF to reclassify lesions depicted with CT angiography, 30 of 70 (43%) coronary lesions were graded as not hemodynamically significant, which significantly increased PPV to 78% (95% CI: 61%, 89%; P = .02). The presence of a coronary artery stenosis with a corresponding MBF less than 75 mL/100 mL/min had a high risk for hemodynamic significance (odds ratio, 86.9; 95% CI:17.6, 430.4). CONCLUSION: Dynamic CT-based stress myocardial perfusion imaging may allow detection of hemodynamically significant coronary artery stenosis.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Viabilidade , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Eur Radiol ; 21(7): 1424-9, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21249370

RESUMO

OBJECTIVE: The aim of the study was to assess the performance and diagnostic value of a dual energy CT approach to reduce metal artefacts in subjects with metallic implants. METHODS: 31 patients were examined in the area of their metallic implants using a dual energy CT protocol (filtered 140 kVp and 100 kVp spectrum, tube current relation: 3:1). Specific post-processing was applied to generate energies of standard 120 and 140 kVp spectra as well as a filtered 140 kVp spectrum with mean photon energies of 64, 69 and 88 keV, respectively, and an optimized hard spectrum of 95-150 keV. Image quality and diagnostic value were subjectively and objectively determined. RESULTS: Image quality was rated superior to the standard image in 29/31 high energy reconstructions; the diagnostic value was rated superior in 27 patients. Image quality and diagnostic value scores improved significantly from 3.5 to 2.1 and from 3.6 to 1.9, respectively. In several exams decisive diagnostic features were only discernible in the high energy reconstructions. The density of the artefacts decreased from -882 to -341 HU. CONCLUSIONS: Dual Energy CT with specific postprocessing can reduce metal artefacts and may significantly enhance diagnostic value in the evaluation of metallic implants.


Assuntos
Artefatos , Metais , Próteses e Implantes , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade
8.
Eur Radiol ; 20(6): 1331-6, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20033181

RESUMO

OBJECTIVE: To determine the practicability and potential dose saving of an imaging algorithm incorporating a pulsing scheme applying systolic data acquisition at heart rates >75 beats per minute (bpm). METHODS: Patients clinically referred for coronary computed tomography angiography (CTA) underwent cardiac CTA using either a diastolic pulsing window (30-70%) or a narrow systolic pulsing window (150 ms at 300 ms). Independent investigators retrospectively determined image quality (1, excellent, to 5, unreadable) and derived effective radiation exposure. RESULTS: Among all 101 subjects (62 +/- 2 years, 59% male) the predicted decrease in the best reconstruction interval for diastolic phases was 12 ms per 1 bpm [95% confidence interval (CI): -13.5 to -11.2] and -1.9 ms for systolic phases (95% CI: -3.2 to -0.62, p = 0.004), independent of age, gender and body mass index (BMI). The systolic pulsing strategy in 47 subjects (23 subjects >75 bpm) resulted in significantly lower radiation exposure (4.97 +/- 2.3 vs 9.38 +/- 5.5 mSv, p < 0.001 for systolic versus diastolic, respectively), whereas there was no difference with respect to image quality or heart rate (p = 0.65 and p = 0.74, respectively). CONCLUSIONS: Our results suggest that a systolic window for tube current modulation in subjects with higher heart rates represents a reliable tool to ensure high image quality at significantly lower dose in patients undergoing routine cardiac CTA.


Assuntos
Algoritmos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sístole
9.
Eur Radiol ; 20(12): 2882-9, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20571800

RESUMO

OBJECTIVE: To evaluate the feasibility of dual-energy CT (DECT) ventilation imaging in combination with DE perfusion mapping for a comprehensive assessment of ventilation, perfusion, morphology and structure of the pulmonary parenchyma. METHODS: Two dual-energy CT acquisitions for xenon-enhanced ventilation and iodine-enhanced perfusion mapping were performed in patients under artificial respiration. Parenchymal xenon and iodine distribution were mapped and correlated with structural or vascular abnormalities. RESULTS: In all datasets, image quality was sufficient for a comprehensive image reading of the pulmonary CTA images, lung window images and pulmonary functional parameter maps and led to expedient results in each patient. CONCLUSION: With dual-source CT systems, DECT of the lung with iodine or xenon administration is technically feasible and makes it possible to depict the regional iodine or xenon distribution representing the local perfusion and ventilation.


Assuntos
Pulmão/diagnóstico por imagem , Imagem de Perfusão/métodos , Ventilação Pulmonar , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Xenônio , Adulto , Idoso , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
J Vasc Interv Radiol ; 21(3): 315-21, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20097097

RESUMO

PURPOSE: To compare true and "virtual" noncontrast images derived from dual-energy CT examinations in patients after endovascular repair of aortic aneurysms. MATERIALS AND METHODS: Seventy dual-energy CT examinations were performed on a dual-source CT scanner with a single-energy noncontrast scan and a dual-energy acquisition in venous phase. True and virtual noncontrast images were compared regarding image quality, calcifications in true noncontrast images, subtraction of calcification in virtual noncontrast images, and acceptance levels by two radiologists. Presence of endoleaks was assessed on venous-phase images and on virtual or true noncontrast images. In addition, the acceptance of color-coded images, in which iodine information is colored, was assessed. Possible dose reduction of a single-phase dual-energy examination protocol was compared with a standard biphasic examination protocol. RESULTS: Twenty-four endoleaks were detected and correctly classified with both approaches. Mean image quality was rated good for virtual noncontrast images (1.97 +/- 0.99) and excellent for true noncontrast images (1.16 +/- 0.37; P< .0001). Ninety-four percent of virtual noncontrast images were rated as diagnostic, and 80% of all true noncontrast images showed calcifications within the aneurysm. Subtraction of calcification in virtual noncontrast images was classified as none (30%), minimal (40%), moderate (24%), or severe (6%). Eighty-three percent of color-coded images were rated as fully diagnostic, 11% were accepted with restrictions, and 6% were nondiagnostic. Possible dose reduction of a single-phase dual-energy protocol, compared with a standard biphasic protocol, was 44%. CONCLUSIONS: Dual-energy CT makes a reliable detection of endoleaks feasible in a single acquisition. This provides a potential dose reduction for patients who have to undergo lifelong follow-up examinations after endovascular aneurysm repair.


Assuntos
Angiografia/métodos , Angioplastia/métodos , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Aortografia/métodos , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
11.
Semin Ultrasound CT MR ; 31(4): 301-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20691930

RESUMO

Dual-energy computed tomography (DECT) can be used for visualization of pulmonary microvascular contrast material distribution, representing regional perfusion. It is performed as DECT angiography and allows for the reconstruction of morphologic images as well as of "perfusion maps." The authors of previous studies have shown its potential to reliably depict perfusion defects, mainly in the context of pulmonary embolism. Also in the diagnostic work-up of other pulmonary diseases, there might be additional functional information provided by dual-energy acquisition techniques. This review focuses on the physical and technical background and the potential clinical value of pulmonary DECT. Technical improvements of a second-generation dual-source CT system are elucidated.


Assuntos
Pneumopatias/diagnóstico por imagem , Circulação Pulmonar , Tomografia Computadorizada por Raios X/métodos , Angiografia , Meios de Contraste , Humanos , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador
12.
Radiology ; 252(2): 433-40, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19487466

RESUMO

PURPOSE: To qualitatively and quantitatively compare virtual nonenhanced (VNE) data sets derived from dual-energy (DE) computed tomography (CT) with true nonenhanced (TNE) data sets in the same patients and to calculate potential radiation dose reductions for a dual-phase renal multidetector CT compared with a standard triple-phase protocol. MATERIALS AND METHODS: This prospective study was approved by the institutional review board; all patients provided written informed consent. Seventy one men (age range, 30-88 years) and 39 women (age range, 22-87 years) underwent preoperative DE CT that included unenhanced, DE nephrographic, and delayed phases. DE CT parameters were 80 and 140 kV, 96 mAs (effective). Collimation was 14 x 1.2 mm. CT numbers were measured in renal parenchyma and tumor, liver, aorta, and psoas muscle. Image noise was measured on TNE and VNE images. Exclusion of relevant anatomy with the 26-cm field of view detector was quantified with a five-point scale (0 = none, 4 = >75%). Image quality and noise (1 = none, 5 = severe) and acceptability for VNE and TNE images were rated. Effective radiation doses for DE CT and TNE images were calculated. Differences were tested with a Student t test for paired samples. RESULTS: Mean CT numbers (+/- standard deviation) on TNE and VNE images, respectively, for renal parenchyma were 30.8 HU +/- 4.0 and 31.6 HU +/- 7.1, P = .29; liver, 55.8 HU +/- 8.6 and 57.8 HU +/- 10.1, P = .11; aorta, 42.1 HU +/- 4.1 and 43.0 HU +/- 8.8, P = .16; psoas, 47.3 HU +/- 5.6 and 48.1 HU +/- 9.3 HU, P = .38. No exclusion of the contralateral kidney was seen in 50 patients, less than 25% was seen in 43, 25%-50% was seen in 13, and 50%-75% was seen in four. Mean image noise was 1.71 +/- 0.71 for VNE and 1.22 +/- 0.45 for TNE (P < .001); image quality was 1.70 HU +/- 0.72 for VNE and 1.15 HU +/- 0.36 for TNE (P < .0001). In all but three patients radiologists accepted VNE images as replacement for TNE images. Mean effective dose for DE CT scans of the abdomen was 5.21 mSv +/- 1.86 and that for nonenhanced scans was 4.97 mSv +/- 1.43. Mean dose reduction by omitting the TNE scan was 35.05%. CONCLUSION: In patients with renal masses, DE CT can provide high-quality VNE data sets, which are a reasonable approximation of TNE data sets. Integration of DE scanning into a renal mass protocol will lower radiation exposure by 35%.


Assuntos
Carga Corporal (Radioterapia) , Neoplasias Renais/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
13.
Eur Radiol ; 19(1): 13-23, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18677487

RESUMO

Dual energy CT (DECT) is a new technique that allows differentiation of materials and tissues based on CT density values derived from two synchronous CT acquisitions at different tube potentials. With the introduction of a new dual source CT system, this technique can now be used routinely in abdominal imaging. Potential clinical applications include evaluation of renal masses, liver lesions, urinary calculi, small bowel, pancreas, and adrenal glands. In CT angiography of abdominal aortic aneurysms, dual energy CT techniques can be used to remove bones from the datasets, and virtual unenhanced images allow differentiation of contrast agent from calcifying thrombus in patients with endovascular stents. This review describes potential applications, practical guidelines, and limitations of dual energy CT in the abdomen.


Assuntos
Absorciometria de Fóton/métodos , Absorciometria de Fóton/tendências , Radiografia Abdominal/métodos , Radiografia Abdominal/tendências , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/tendências , Europa (Continente) , Humanos , Projetos Piloto , Padrões de Prática Médica/tendências
14.
AJR Am J Roentgenol ; 193(1): 144-9, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19542406

RESUMO

OBJECTIVE: The purpose of this study was to assess the feasibility and diagnostic value of dual-energy CT iodine mapping at pulmonary CT angiography. SUBJECTS AND METHODS: Ninety-three patients underwent CT angiography with the dual-energy technique on a dual-source CT scanner. Postprocessing was used to map iodine in the lung parenchyma on the basis of its spectral behavior, and image quality was assessed by two readers. Iodine distribution patterns were rated as homogeneous, patchy, or circumscribed defects. Conventional CT angiographic images reconstructed from the same data sets were reviewed for the presence and localization of pulmonary embolism, whether embolic occlusion was partial or complete, and the presence of changes in the lung parenchyma. Dual-energy perfusion findings were correlated with the CT angiographic and lung-window CT findings in per-patient and per-segment analyses. RESULTS: Iodine distribution was homogeneous in 49 patients, of whom CT angiography showed no pulmonary embolism in 46 patients and nonocclusive pulmonary emboli in three patients. Images of 29 patients showed a patchy pattern; 24 of these patients had no pulmonary embolism, and five had nonocclusive pulmonary emboli with solely nonocclusive intravascular clots. Images of 15 patients showed segmental or subsegmental defects; four of these patients had evidence of pulmonary embolism, and 11 had occlusive pulmonary emboli with at least one occlusive clot in the pulmonary vasculature. CONCLUSION: Dual-energy CT is reliable in the detection of defects in pulmonary parenchymal iodine distribution that correspond to embolic vessel occlusion.


Assuntos
Iodo/farmacocinética , Pulmão/diagnóstico por imagem , Pulmão/metabolismo , Embolia Pulmonar/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Angiografia/métodos , Meios de Contraste/farmacocinética , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
15.
Invest Radiol ; 43(2): 112-9, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18197063

RESUMO

OBJECTIVE: The purpose of this study is to assess the accuracy of dual energy CT (DECT) in the characterization of renal and ureteral stones. MATERIAL AND METHODS: Twenty-four renal calculi of known variable composition were scanned on a dual-source CT scanner (Somatom Definition; Siemens Medical Solutions, Forchheim, Germany) in dual energy (DECT) mode. Scan parameters for DECT were: tube potentials, 80 and 140 kV; tube current, 342 and 76 mA.s; collimation, 14 x 1.2 mm2. Dual energy properties of calculi were used to differentiate between uric acid (UA) and other calculi. Differentiation was based on a 3-material decomposition implemented in the dual energy software (Syngo VA 11; Siemens Medical Solutions). Color coding was used to display different types of stones and their DECT properties were characterized with density measurements at both photon energies. Subsequently, 20 consecutive patients with known or suspected uroliths were scanned using identical scan parameters. Stone size and material were assessed in DECT and compared with the chemical analyses of stones after mechanical extraction. RESULTS: With DECT characterization, differentiation of UA from other calculi was possible. Additionally, differentiation between cystine and struvite stones was shown to be feasible in vitro. In the patient cohort, DECT correctly characterized 4 UA calculi, 4 mixed, multiple calcified, and 1 cystine stone. The calculi were displayed in specific colors, ie, UA stones in red and calcified stones in blue. CONCLUSION: With dual energy CT techniques, the UA, cystine, struvite, and mixed renal calculi can be differentiated from other types of stones in vitro and in vivo. This is of clinical relevance as UA uroliths may be treated pharmacologically rather than with surgical extraction or extracorporal shockwave lithotripsy.


Assuntos
Tomografia Computadorizada de Emissão , Ácido Úrico , Cálculos Urinários/diagnóstico , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Ureteroscopia , Cálculos Urinários/patologia
16.
Anticancer Res ; 28(4C): 2303-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18751410

RESUMO

BACKGROUND: Positron emission tomography-computed tomography (PET-CT) is currently not established in the management of recurrent ovarian cancer. Here, its value in diagnosis and therapy planning was evaluated. PATIENTS AND METHODS: Seventy patients received PET-CT for suspicion of recurrent ovarian cancer. PET-CT and surgery were reviewed to analyze the accuracy in the diagnosis of recurrence and prediction of full resectability. RESULTS: PET-CT showed disease relapse in 63 of 70 patients, with full sensitivity and specificity. Thirty cases were operated on. PET-CT indicated full resectability in 24, but in fact only incomplete resection was possible in three cases. Thus sensitivity and specificity for the identification of full resectability were 100% and 66%, respectively. Seven negative results in PET-CT were confirmed by a relapse-free follow-up of 1 year. CONCLUSION: PET-CT offers reliable detection of recurrent ovarian cancer. Although diagnostic accuracy in the prediction of full resectability is limited, surgical planning is improved by identifying sites of intraperitoneal involvement.


Assuntos
Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/terapia , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Feminino , Fluordesoxiglucose F18 , Humanos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/tratamento farmacológico , Recidiva Local de Neoplasia/cirurgia , Neoplasias Ovarianas/tratamento farmacológico , Neoplasias Ovarianas/cirurgia , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade
17.
Invest Radiol ; 42(10): 684-91, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17984765

RESUMO

PURPOSE: The aim of this study was to evaluate the diagnostic accuracy of dual-source computed tomography (DSCT) with reference to invasive coronary angiography in the diagnosis of coronary artery disease (CAD) on a per-patient as well as on a per-segment basis. MATERIALS AND METHODS: Thirty-five patients with known or suspected CAD underwent both DSCT (Somatom Definition, Siemens Medical Solutions) and quantitative x-ray coronary angiography (QCA). Parameters of CT acquisition were gantry rotation time 0.330 seconds (ie, temporal resolution 83 milliseconds), tube voltage 120 kV, tube current 560 mA with ECG-triggered tube current modulation and full current at 70% of the cardiac cycle for heart rates below 70 beats per minute or full current between 30% and 80% for higher and arrhythmic heart rates. The pitch was also adapted to the heart rate, ranging from 0.2 to 0.43. Volume and flow rate of contrast material (Ultravist 370, Schering AG) were adapted to the patient's body weight. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of DSCT in the detection or exclusion of significant CAD (ie, stenoses >50%) were evaluated on a per-patient and per-segment basis. RESULTS: All 35 CT angiograms were of diagnostic image quality. QCA demonstrated significant CAD in 48% (n = 17) and nonsignificant disease or normal coronary angiograms in 52% (n = 18) of the patients. Sensitivity, specificity, PPV, and NPV of DSCT on a per-patient basis were 100%, 89%, 89%, and 100%, respectively. On a per-segment basis, 473 of 481 coronary artery segments were assessable (98%). QCA demonstrated stenoses >50% in 32 segments (7%), and no disease or nonsignificant disease in 433 segments (93%). For the detection of stenoses >50% on a per-segment basis, DSCT showed a sensitivity, specificity, PPV, and NPV of 88%, 98%, 78%, and 99%, respectively. CONCLUSIONS: The comparison of coronary DSCT with QCA shows a very robust image quality and a high diagnostic accuracy in a patient-based as well as a per-segment analysis. Maximal sensitivity and NPV in the per-patient analysis show the strength of the technique in ruling out significant CAD.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico , Tomografia Computadorizada de Emissão/instrumentação , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão/métodos
18.
AJR Am J Roentgenol ; 188(1): 76-82, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17179348

RESUMO

OBJECTIVE: The most important differential diagnoses of acute chest pain include myocardial infarction, aortic dissection, and pulmonary embolism. The purpose of this study was to evaluate the diagnostic value of an ECG-gated 64-MDCT angiography protocol for simultaneous assessment of the pulmonary arteries, coronary arteries, and aorta within a single breath-hold. SUBJECTS AND METHODS: In 55 patients with acute chest pain, ECG-gated CT angiography was performed with a CT system in which 64 slices per gantry rotation were acquired. Density measurement and visual assessment of motion artifacts were performed to evaluate image quality. CT findings were correlated with results of laboratory tests and clinical follow-up. For 20 patients, two independent blinded reviewers compared findings on CT angiography with those on X-ray coronary angiography. RESULTS: Adequate contrast enhancement of the pulmonary vessels, coronary arteries, and aorta was achieved in all cases. Regarding image quality of the coronary arteries, there was minor blurring in seven patients, and in one examination the images did not provide enough information for diagnosis. The average image quality rating was 1.2 on a scale in which 1 indicated no artifacts; 2, minor motion artifacts; and 3, image insufficient for diagnosis. The cause of chest pain was correctly identified with MDCT in 37 patients. The diagnoses included pulmonary embolism (n = 10), coronary stenosis (n = 9), and aortic dissection (n = 1). In four patients, additional diagnoses were found with other examinations. CONCLUSION: With current techniques, ECG-gated CT angiography of the entire chest has very good image quality. The protocol proved helpful in the differential diagnosis of acute chest pain.


Assuntos
Angiografia/métodos , Aneurisma Aórtico/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Dor no Peito/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Idoso , Aortografia/métodos , Artefatos , Dor no Peito/etiologia , Angiografia Coronária/métodos , Diagnóstico Diferencial , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Infarto do Miocárdio/complicações , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/complicações , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação
19.
Eur J Obstet Gynecol Reprod Biol ; 129(2): 119-23, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16971036

RESUMO

OBJECTIVE: To assess the number and quality of scientific articles published by authors from the European Union (EU) and Germany in the field of obstetrics and gynecology. STUDY DESIGN: Scientific articles published during the years 1980-2003 covered by the Journal Citation Report (JCR) were considered, with a focus on the impact factor (IF), authors' origin, journal country and publishing language. RESULTS: In 2003, there are 53 journals listed by the JCR for the field category 'obstetrics and gynecology', with altogether 3201 publications listed in the Science Citation Index (SCI). From the year 1980, the total number of publications increased persistently. Looking at the top 20 journals in the field of obstetrics and gynecology, there are 12 journals from the US, 8 from Europe. None of these journals has an IF>10 but 30 journals show an IF>1. Over the last 25 years, a growing importance of the English language as scientific language can be observed. CONCLUSION: These data indicate an important role of European research in the field of obstetrics and gynecology comparable to that of US-American research. The English language is gaining importance as scientific language, displacing other languages and contributing to a loss of impact of non-English journals.


Assuntos
Bibliometria , Ginecologia/tendências , Obstetrícia/tendências , Editoração/tendências , Europa (Continente) , Humanos , Idioma , Editoração/estatística & dados numéricos , Mudança Social
20.
Acad Radiol ; 21(12): 1567-72, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25442353

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the benefits of dual-energy computed tomography (CT) colonography (DECTC) as a preoperative staging tool in patients with clinically suspected colorectal cancer (CRC). MATERIALS AND METHODS: Twenty-two patients with colorectal neoplasia underwent preoperative abdominal DECTC on a dual-source scanner (SOMATOM Definition Flash; Siemens) operated at tube potentials of Sn140/100 kVp. Scans were evaluated for local tumor stage and the presence of synchronous intracolonic and extracolonic findings using dual-energy color-coded images. An enhancement ≥25 Hounsfield units (HU) was defined to indicate malignancy. Patients' effective doses were calculated. RESULTS: Preoperative DECTC allowed for complete bowel evaluation in all patients, including subjects with stenosing CRC. DECTC revealed 22 carcinomas (mean enhancement, 47 ± 12 HU). In total, 22 synchronous intracolonic lesions were detected, including 19 adenomas (mean enhancement, 51 ± 19 HU). Benign structures showed enhancement <25 HU. Comparing DECTC to histopathology, 95% carcinomas and 71% synchronous lesions proximal to stenosing CRC could be verified. Mean estimated effective dose was 13.0 ± 5.2 mSv. CONCLUSIONS: Preoperative DECTC can be used as an accurate and dose-efficient primary-staging examination. Especially after incomplete optical colonoscopy, virtual colonoscopy enables full preoperative colonic assessment on the same day. Dual-energy CT enables distinction between neoplasia and non-neoplastic findings within and outside the colon. Therefore, DECTC can be regarded as a promising "one-stop" staging examination in patients with clinically suspected CRC.


Assuntos
Neoplasias do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Idoso , Idoso de 80 Anos ou mais , Neoplasias do Colo/patologia , Neoplasias do Colo/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Cuidados Pré-Operatórios
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA