RESUMO
OBJECTIVE: A precise understanding of the radiological anatomy and biomechanics as well as reliable reference values of the hip are essential. The primary goal of this study was to provide reference values of the neck-shaft angle (NSA) for adult patients based on the analysis of rotation corrected computed tomography (CT) scans of 800 hips. The secondary aim was to compare these measurements with simulated anteroposterior roentgenograms of the pelvis. MATERIALS AND METHODS: Pelvic CT scans of 400 patients (54.3 years, range 18-100 years; 200 female) were reconstructed in the derotated coronal plane of the proximal femur and as CT-based simulated anteroposterior roentgenograms of the pelvis in the anterior pelvic plane. Femora were categorized as coxa vara (<120°), physiologic (≥120° to <135°), and coxa valga (≥135°). Intra- and inter-rater reliability were analyzed. RESULTS: Primary research question: Mean NSA for male adults was 129.6° (range 113.2°-148.2°; SD 5.9°) and 131.9° (range 107.1°-151.9°; SD 6.8°) for females in derotated coronal reconstructions. Age (p < 0.001 in both views) and sex influenced the NSA significantly (p = 0.002 and p < 0.001); no significant differences were found between sides (p = 0.722 and p = 0.955). Overall, an excellent reliability of repeated measurements of one or two observers was found (ICC 0.891-0.995). Secondary research question: NSA values measured in the simulated anteroposterior roentgenogram and the rotation corrected coronal reconstruction differed significantly (p < 0.001). CONCLUSIONS: While anteroposterior pelvis radiographs are susceptible to rotational errors, the coronal reconstruction of the proximal femur in the femoral neck plane allows the correct measurement of the NSA.
Assuntos
Articulação do Quadril/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Valores de Referência , Estudos RetrospectivosRESUMO
BACKGROUND: The present study aimed to analyze the agreement between proximal femoral geometry of adult hips and femoral component design in total hip arthroplasty. METHODS: Anatomical femoral offset (FOAnat) and the anatomical neck-shaft angle (NSAAnat) of 800 adult hips were measured by computed tomography scans, and anatomical femoral neck height (FHAnat) was calculated. Corresponding best-fit implants of the most common hip system (standard, high offset and varus variant) were identified for each hip. Finally, the precision of the best possible anatomic reconstruction was assessed. RESULTS: The mean FOAnat was 38.0 mm (range: 19.8-57.9 mm, standard deviation [SD]: 6.4 mm), the mean NSAAnat was 130.8° (range: 107.1°-151.9°; SD: 6.5°), and the mean FHAnat was 32.6 mm (range: 14.4-52.0 mm; SD: 5.5 mm). In 450 (56.3%) hips, the standard variant was identified to be the best-fit implant, followed by the varus (n = 282, 35.3%) and the high offset (n = 68, 8.5%) variants. The mean minimal distance from the best-fit implant was 4.5 mm (range: 0.1-20.2 mm, SD: 3.4 mm). Excellent agreement (distance: <2 mm) between hip anatomy and best-fit implant was found in 203 (25.4%) hips, combined excellent and acceptable agreement (distance: <6 mm) in 569 (71.1%) hips, whereas 213 (28.9%) hips were graded as poor (distance: ≥6 mm). CONCLUSION: The present study revealed a mismatch between proximal femoral anatomy of a relevant proportion of adult hips and implant geometry of the most common femoral component in total hip arthroplasty.
Assuntos
Artroplastia de Quadril/métodos , Colo do Fêmur/cirurgia , Fêmur/cirurgia , Prótese de Quadril , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Desenho de Prótese , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto JovemRESUMO
Background. The femoral neck-shaft angle (NSA) is of high importance for the diagnostics and treatment of various conditions of the hip. However, rotational effects limit its precision and applicability using plain radiographs. This study introduces a novel method to measure the femoral NSA: the modified NSA (mNSA), possibly being less susceptible against rotational effects compared to the conventional NSA. Patients and Methods. The method of measurement is described and its applicability was tested in 400 pelvis computed tomography scans (800 hips). Age- and gender-dependent reference values are given and intra- and interrater reliability are analyzed. Results. The mean age of all 400 patients (800 hips) was 54.32 years (18-100, SD 22.05 years). The mean mNSA was 147.0° and the 95% confidence interval was 146.7°-147.4°. Differences of the mNSA between sexes, age groups, and sides were nonsignificant. The absolute difference between NSA and mNSA was 16.3° (range 3-31°; SD 4.4°); the correlation was high (0.738; p < 0.001). Overall, the intra- and interrater reliability were excellent for the mNSA. Interpretation. We introduced a novel concept for the analysis of the neck-shaft angle. The high reliability of the measurement has been proven and its robustness to hip rotation was demonstrated.