Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiology ; 270(1): 159-67, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24029649

RESUMO

PURPOSE: To evaluate performance of increased bowel-wall attenuation on unenhanced 64-section multidetector computed tomographic (CT) images for diagnosing bowel-wall ischemia in patients with mechanical small-bowel obstruction (SBO) and to evaluate the diagnostic accuracy of multidetector CT in detecting small-bowel ischemia complicating SBO, with surgical and histopathologic findings as reference standard. MATERIALS AND METHODS: The local institutional review board approved this retrospective study; informed consent requirement was waived. In 44 patients (10 men, 34 women; age range, 30-100 years) who were admitted because they were suspected of having SBO and treated surgically within the next 7 days, 45 multidetector CT scans were retrospectively reviewed. Two gastrointestinal radiologists performed independent blinded reviews of images to identify specific signs of ischemia; disagreements were resolved in consensus with a third gastrointestinal radiologist. Results were compared with both findings in prospective radiology reports and surgical and histopathologic findings. Fisher exact and χ(2) tests were used to assess associations between CT signs and ischemia, and the κ statistic was used to assess interobserver agreement. RESULTS: In 19 of 45 (42%) multidetector CT scans, ischemia was confirmed at surgery and/or histopathologic examination. Increased bowel-wall attenuation on unenhanced images was significantly associated with ischemia (P < .0001); in this highly selected population, this sign had a 100% (24 of 24) specificity and a 56% (10 of 18) sensitivity. Sensitivity and specificity of multidetector CT for ischemia were 63% (12 of 19) and 92% (24 of 26), respectively, for the prospective reports and 84% (16 of 19) and 96% (25 of 26), respectively, for the consensus review. Decreased segmental bowel-wall enhancement was the most accurate 64-section multidetector CT sign for diagnosing ischemia (sensitivity, 78% [14 of 18]; specificity, 96% [24 of 25]; P < .0001). The small-bowel feces sign was significantly associated with ischemia (P = .0308). CONCLUSION: Increased bowel-wall attenuation on unenhanced 64-section multidetector CT images is a specific sign for ischemia complicating SBO. Diagnostic accuracy of 64-section multidetector CT for ischemia associated with SBO was excellent.


Assuntos
Obstrução Intestinal/complicações , Obstrução Intestinal/diagnóstico por imagem , Intestino Delgado/irrigação sanguínea , Intestino Delgado/diagnóstico por imagem , Isquemia/diagnóstico por imagem , Isquemia/etiologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Obstrução Intestinal/cirurgia , Intestino Delgado/cirurgia , Iopamidol/análogos & derivados , Isquemia/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
Radiographics ; 31(3): E35-46, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21721196

RESUMO

Acute gastrointestinal (GI) bleeding remains an important cause of emergency hospital admissions, with substantial related morbidity and mortality. Bleeding may relate to the upper or lower GI tract, with the dividing anatomic landmark between these two regions being the ligament of Treitz. The widespread availability of endoscopic equipment has had an important effect on the rapid identification and treatment of the bleeding source. However, the choice of upper or lower GI endoscopy is largely dictated by the clinical presentation, which in many cases proves misleading. Furthermore, there remains a large group of patients with negative endoscopic results or failed endoscopy, in whom additional techniques are required to identify the source of GI bleeding. Multidetector computed tomography (CT) with its speed, resolution, multiplanar techniques, and angiographic capabilities allows excellent visualization of both the small and large bowel. Multiphasic multidetector CT allows direct demonstration of bleeding into the bowel and is helpful in the acute setting for visualization of the bleeding source and its characterization. Thus, multidetector CT angiography provides a time-efficient method for directing and planning therapy for patients with acute GI bleeding. The additional information provided by multidetector CT angiography before attempts at therapeutic angiographic procedures leads to faster selective catheterization of bleeding vessels, thereby facilitating embolization. Supplemental material available at http://radiographics.rsna.org/lookup/suppl/doi:10.1148/rg.313105206/-/DC1.


Assuntos
Angiografia/métodos , Hemorragia Gastrointestinal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Meios de Contraste , Diagnóstico Diferencial , Embolização Terapêutica , Endoscopia Gastrointestinal/métodos , Hemorragia Gastrointestinal/terapia , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade
3.
Emerg Radiol ; 17(1): 51-6, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19517148

RESUMO

The objectives of this study are to evaluate the prevalence of left acute colonic diverticulitis (LACD) associated with secondary epiploic appendagitis (SEA) detected by computed tomography (CT); to describe CT features that distinguish LACD associated with SEA from primary epiploic appendagitis (PEA); and to assess the accuracy of CT in diagnosing LACD associated with SEA versus PEA. Institutional review board approval was obtained. We retrospectively identified 46 consecutive patients with LACD between July 2004 and July 2005 and 26 patients with PEA between 2000 and 2005 investigated using multidetector CT. Two radiologists blinded to the final diagnosis reviewed the CT images for findings of LACD-associated SEA or PEA. Each reader classified each CT scan into one of four categories: PEA, LACD-associated SEA, LACD without SEA, and indeterminate. Fisher's exact test and Wilcoxon test were performed to compare the groups. The prevalence of LACD-associated SEA was 71% (33/46) in the LACD group. The accuracy of CT was 100% for diagnosing LACD-associated SEA (33/33), 100% for diagnosing LACD without SEA (13/13), and 96% for diagnosing PEA (25/26). Colon wall thickening, "inflamed diverticulum", extraluminal gas, abscess or phlegmon, multiple paracolic fatty lesions, and a thin hyperattenuated rim were significantly associated with LACD-associated SEA. Neither the dot sign nor parietal peritoneal thickening showed good accuracy for differentiating PEA from LACD-associated SEA. CT is accurate for distinguishing LACD-associated SEA from PEA. The findings that perform best for diagnosing SEA are evidence of diverticulitis, multiple fatty lesions, and a thin hyperattenuated rim.


Assuntos
Dor Abdominal/diagnóstico por imagem , Colo/diagnóstico por imagem , Doença Diverticular do Colo/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Dor Abdominal/epidemiologia , Adulto , Idoso , Meios de Contraste , Diagnóstico Diferencial , Doença Diverticular do Colo/epidemiologia , Feminino , Humanos , Iopamidol , Ácido Iotalâmico/análogos & derivados , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Estatísticas não Paramétricas
4.
Abdom Imaging ; 34(1): 35-41, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-18172705

RESUMO

PURPOSE: To assess the additional value of multiplanar reformations (MPR) in comparison with axial images alone for location of the transition zone in CT of mechanical small-bowel obstruction (SBO). MATERIALS AND METHODS: Sixty-nine consecutive patients with mechanical SBO underwent 16-slice multi detector row CT (MDCT). The gold standard for the precise location of the transition zone was established by two experienced abdominal radiologists, unblinded to clinical and surgical reports, reviewing all CT examinations. On a workstation, two blinded readers independently located the transition zone using first axial slices alone and then 1 month later MPR (axial, coronal, sagittal and oblique views) according to a three-point confidence scale. Diagnostic accuracy and mean confidence score were evaluated for both the transverse and multiplanar data sets. RESULTS: Accuracy of transition zone location for reader 1 and reader 2 was 86% and 84% with axial slices alone, and by using MPR 93% (significant: P = 0.03) and 90% (not significant: P = 0.08), respectively. Mean confidence score was significantly increased for both readers using MPR: 0.3 higher (P = 0.0001) and 0.37 higher (P = 0.0001) respectively. CONCLUSION: MPR can increase both accuracy and confidence in the location of the transition zone in CT of SBO.


Assuntos
Obstrução Intestinal/diagnóstico por imagem , Intestino Delgado , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste/administração & dosagem , Feminino , Humanos , Obstrução Intestinal/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
Radiographics ; 26 Suppl 1: S5-18; discussion S42-3, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17050519

RESUMO

Because of the great diversity of clinical features, its unforeseeable evolution, and a small proportion of cases that will worsen in the acute phase, cerebral venous thrombosis must be diagnosed as early as possible so that specific treatment can be started, typically transcatheter thrombolysis or systemic anticoagulation. Unenhanced computed tomography (CT) is usually the first imaging study performed on an emergency basis. Unenhanced CT allows detection of ischemic changes related to venous insufficiency and sometimes demonstrates a hyperattenuating thrombosed dural sinus or vein. Helical multidetector CT venography with bolus power injection of contrast material and combined use of two-dimensional and three-dimensional reformations (maximum intensity projection, integral display, and volume rendering) provides exquisite anatomic detail of the deep and superficial intracranial venous system and can demonstrate filling defects. However, common variants of the sinovenous system should not be mistaken for sinus thrombosis. A comprehensive diagnostic approach facilitates imaging of cerebral venous thrombosis with multidetector CT.


Assuntos
Angiografia Cerebral/métodos , Veias Cerebrais/diagnóstico por imagem , Meios de Contraste , Flebografia/métodos , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Trombose Venosa/diagnóstico por imagem , Humanos , Imageamento Tridimensional/métodos , Guias de Prática Clínica como Assunto , Padrões de Prática Médica
6.
Insights Imaging ; 2(1): 69-84, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22347935

RESUMO

Colonic diverticulitis (CD) is a common entity whose diagnosis is particularly based on computed tomography (CT) examination, which is the imaging technique of choice. However, unusual CT findings of CD may lead to several difficulties and potential pitfalls: due to technical errors in the management of the CT examination, due to the anatomical situation of the diseased colon, in diagnosing unusual complications that may concern the gastrointestinal tract, intra- and retroperitoneal viscera or the abdominal wall, and in differentiating CD from other abdominal inflammatory and infectious conditions or colonic cancer. The aim of this work is to delineate the pitfalls of CT imaging and illustrate misleading CT features in patients with suspected CD.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA