Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Infection ; 52(1): 183-195, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37589812

RESUMO

PURPOSE: Blood culture (BC) diagnostics are influenced by many factors. We performed a targeted interdisciplinary analysis to analyse effects of various measures on BC diagnostics performance. METHODS: A diagnostic stewardship initiative was conducted at two intervention and two control wards in a German tertiary level hospital. The initiative comprised staff training on the correct indications and sampling for BC, implementation of information cards, labels to identify the collection site, regular BC bottle feedback including the number of bottles, filling volumes and identified pathogens; and the use of a specific sampling device (BD Vacutainer®). Before and after the interventions, two three-month measurement periods were performed, as well as a one-month follow-up period to assess the sustainability of the conducted measures. RESULTS: In total, 9362 BC bottles from 787 patients were included in the analysis. The number of BCs obtained from peripheral venous puncture could be increased at both intervention wards (44.0 vs. 22.2%, 58.3 vs. 34.4%), while arterial sampling could be reduced (30.6 vs. 4.9%). A total of 134 staff members were fully trained. The intervention led to a considerable increase in BC knowledge (from 62.4 to 79.8% correct answers) with differences between the individual professional groups. Relevant reduced contamination rates could be detected at both intervention wards. CONCLUSIONS: As knowledge on the correct BC sampling and strategies to reduce contamination varies considerably between clinical departments and healthcare professionals, a targeted training should be adapted to the specific needs of the individual professional groups. An additional filling device is not necessary.


Assuntos
Hemocultura , Manejo de Espécimes , Humanos , Pessoal de Saúde
2.
Pediatr Crit Care Med ; 25(2): 147-158, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37909825

RESUMO

OBJECTIVES: Extremes of patient body mass index are associated with difficult intubation and increased morbidity in adults. We aimed to determine the association between being underweight or obese with adverse airway outcomes, including adverse tracheal intubation (TI)-associated events (TIAEs) and/or severe peri-intubation hypoxemia (pulse oximetry oxygen saturation < 80%) in critically ill children. DESIGN/SETTING: Retrospective cohort using the National Emergency Airway for Children registry dataset of 2013-2020. PATIENTS: Critically ill children, 0 to 17 years old, undergoing TI in PICUs. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Registry data from 24,342 patients who underwent TI between 2013 and 2020 were analyzed. Patients were categorized using the Centers for Disease Control and Prevention weight-for-age chart: normal weight (5th-84th percentile) 57.1%, underweight (< 5th percentile) 27.5%, overweight (85th to < 95th percentile) 7.2%, and obese (≥ 95th percentile) 8.2%. Underweight was most common in infants (34%); obesity was most common in children older than 8 years old (15.1%). Underweight patients more often had oxygenation and ventilation failure (34.0%, 36.2%, respectively) as the indication for TI and a history of difficult airway (16.7%). Apneic oxygenation was used more often in overweight and obese patients (19.1%, 19.6%) than in underweight or normal weight patients (14.1%, 17.1%; p < 0.001). TIAEs and/or hypoxemia occurred more often in underweight (27.1%) and obese (24.3%) patients ( p < 0.001). TI in underweight children was associated with greater odds of adverse airway outcome compared with normal weight children after adjusting for potential confounders (underweight: adjusted odds ratio [aOR], 1.09; 95% CI, 1.01-1.18; p = 0.016). Both underweight and obesity were associated with hypoxemia after adjusting for covariates and site clustering (underweight: aOR, 1.11; 95% CI, 1.02-1.21; p = 0.01 and obesity: aOR, 1.22; 95% CI, 1.07-1.39; p = 0.002). CONCLUSIONS: In underweight and obese children compared with normal weight children, procedures around the timing of TI are associated with greater odds of adverse airway events.


Assuntos
Estado Terminal , Obesidade Infantil , Lactente , Criança , Humanos , Recém-Nascido , Pré-Escolar , Adolescente , Estudos Retrospectivos , Sobrepeso/etiologia , Obesidade Infantil/complicações , Obesidade Infantil/epidemiologia , Magreza/complicações , Magreza/epidemiologia , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/métodos , Hipóxia/epidemiologia , Hipóxia/etiologia , Sistema de Registros
3.
Neurocrit Care ; 40(1): 205-214, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37160847

RESUMO

BACKGROUND: Ketamine has traditionally been avoided for tracheal intubations (TIs) in patients with acute neurological conditions. We evaluate its current usage pattern in these patients and any associated adverse events. METHODS: We conducted a retrospective observational cohort study of critically ill children undergoing TI for neurological indications in 53 international pediatric intensive care units and emergency departments. We screened all intubations from 2014 to 2020 entered into the multicenter National Emergency Airway Registry for Children (NEAR4KIDS) registry database. Patients were included if they were under the age of 18 years and underwent TI for a primary neurological indication. Usage patterns and reported periprocedural composite adverse outcomes (hypoxemia < 80%, hypotension/hypertension, cardiac arrest, and dysrhythmia) were noted. RESULTS: Of 21,562 TIs, 2,073 (9.6%) were performed for a primary neurological indication, including 190 for traumatic brain injury/trauma. Patients received ketamine in 495 TIs (23.9%), which increased from 10% in 2014 to 41% in 2020 (p < 0.001). Ketamine use was associated with a coindication of respiratory failure, difficult airway history, and use of vagolytic agents, apneic oxygenation, and video laryngoscopy. Composite adverse outcomes were reported in 289 (13.9%) Tis and were more common in the ketamine group (17.0% vs. 13.0%, p = 0.026). After adjusting for location, patient age and codiagnoses, the presence of respiratory failure and shock, difficult airway history, provider demographics, intubating device, and the use of apneic oxygenation, vagolytic agents, and neuromuscular blockade, ketamine use was not significantly associated with increased composite adverse outcomes (adjusted odds ratio 1.34, 95% confidence interval CI 0.99-1.81, p = 0.057). This paucity of association remained even when only neurotrauma intubations were considered (10.6% vs. 7.7%, p = 0.528). CONCLUSIONS: This retrospective cohort study did not demonstrate an association between procedural ketamine use and increased risk of peri-intubation hypoxemia and hemodynamic instability in patients intubated for neurological indications.


Assuntos
Ketamina , Insuficiência Respiratória , Criança , Humanos , Adolescente , Estudos Retrospectivos , Ketamina/efeitos adversos , Estado Terminal/terapia , Intubação Intratraqueal/efeitos adversos , Hipóxia , Insuficiência Respiratória/etiologia
4.
J Clin Microbiol ; 61(10): e0056923, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37768103

RESUMO

Blood culture diagnostics require rapid and accurate identification (ID) of pathogens and antimicrobial susceptibility testing (AST). Standard procedures, involving conventional cultivation on agar plates, may take up to 48 hours or more until AST completion. Recent approaches aim to shorten the processing time of positive blood cultures (PBC). The FAST System is a new technology, capable of purifying and concentrating bacterial/fungal pathogens from positive blood culture media and producing a bacterial suspension called "liquid colony" (LC), which can be further used in downstream analyses (e.g., ID and AST). Here, we evaluated the performance of the FAST System LC generated from PBC in comparison to our routine workflow including ID by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using Sepsityper, AST by automatized MicroScan WalkAway plus and directly inoculated disk diffusion (DD), and MICRONAUT-AM for yeast/fungi. A total of 261 samples were analyzed, of which 86.6% (226/261) were eligible for the comparative ID and AST analyses. In comparison to the reference technique (culture-grown colonies), ID concordance of the FAST System LC and Sepsityper was 150/154 (97.4%) and 123/154 (79.9%), respectively, for Gram positive; 67/70 (95.7%) and 64/70 (91.4%), respectively, for Gram negative. For AST, categorical agreement (CA) of the FAST System LC in comparison to the routine workflow for Gram-positive bacteria was 96.1% and 98.7% for MicroScan and DD, respectively. Similar results were obtained for Gram-negative bacteria with 96.6% and 97.5% of CA for MicroScan and DD, respectively. Taken together, the FAST System LC allowed the laboratory to significantly reduce the time to obtain correct ID and AST (automated MicroScan) results 1 day earlier and represents a promising tool to expedite the processing of PBC.


Assuntos
Antibacterianos , Bacteriemia , Humanos , Antibacterianos/farmacologia , Hemocultura/métodos , Testes de Sensibilidade Microbiana , Farmacorresistência Bacteriana , Bactérias , Bactérias Gram-Negativas , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Bacteriemia/diagnóstico , Bacteriemia/microbiologia
5.
Basic Res Cardiol ; 118(1): 14, 2023 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-37020075

RESUMO

Human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) are increasingly used for personalised medicine and preclinical cardiotoxicity testing. Reports on hiPSC-CM commonly describe heterogenous functional readouts and underdeveloped or immature phenotypical properties. Cost-effective, fully defined monolayer culture is approaching mainstream adoption; however, the optimal age at which to utilise hiPSC-CM is unknown. In this study, we identify, track and model the dynamic developmental behaviour of key ionic currents and Ca2+-handling properties in hiPSC-CM over long-term culture (30-80 days). hiPSC-CMs > 50 days post differentiation show significantly larger ICa,L density along with an increased ICa,L-triggered Ca2+-transient. INa and IK1 densities significantly increase in late-stage cells, contributing to increased upstroke velocity and reduced action potential duration, respectively. Importantly, our in silico model of hiPSC-CM electrophysiological age dependence confirmed IK1 as the key ionic determinant of action potential shortening in older cells. We have made this model available through an open source software interface that easily allows users to simulate hiPSC-CM electrophysiology and Ca2+-handling and select the appropriate age range for their parameter of interest. This tool, together with the insights from our comprehensive experimental characterisation, could be useful in future optimisation of the culture-to-characterisation pipeline in the field of hiPSC-CM research.


Assuntos
Células-Tronco Pluripotentes Induzidas , Miócitos Cardíacos , Humanos , Idoso , Cálcio , Potenciais de Ação , Diferenciação Celular
6.
Basic Res Cardiol ; 117(1): 5, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-35499658

RESUMO

Dilated cardiomyopathy (DCM) is a major risk factor for heart failure and is associated with the development of life-threatening cardiac arrhythmias. Using a patient-specific induced pluripotent stem cell-derived cardiomyocyte (iPSC-CM) model harbouring a mutation in cardiac troponin T (R173W), we aim to examine the cellular basis of arrhythmogenesis in DCM patients with this mutation. iPSC from control (Ctrl) and DCM-TnT-R173W donors from the same family were differentiated into iPSC-CM and analysed through optical action potential (AP) recordings, simultaneous measurement of cytosolic calcium concentration ([Ca2+]i) and membrane currents and separately assayed using field stimulation to detect the threshold for AP- and [Ca2+]i-alternans development. AP duration was unaltered in TnT-R173W iPSC-CM. Nevertheless, TnT-R173W iPSC-CM showed a strikingly low stimulation threshold for AP- and [Ca2+]i-alternans. Myofilaments are known to play a role as intracellular Ca2+ buffers and here we show increased Ca2+ affinity of intracellular buffers in TnT-R173W cells, indicating increased myofilament sensitivity to Ca2+. Similarly, EMD57033, a myofilament Ca2+ sensitiser, replicated the abnormal [Ca2+]i dynamics observed in TnT-R173W samples and lowered the threshold for alternans development. In contrast, application of a Ca2+ desensitiser (blebbistatin) to TnT-R173W iPSC-CM was able to phenotypically rescue Ca2+ dynamics, normalising Ca2+ transient profile and minimising the occurrence of Ca2+ alternans at physiological frequencies. This finding suggests that increased Ca2+ buffering likely plays a major arrhythmogenic role in patients with DCM, specifically in those with mutations in cardiac troponin T. In addition, we propose that modulation of myofilament Ca2+ sensitivity could be an effective anti-arrhythmic target for pharmacological management of this disease.


Assuntos
Cardiomiopatia Dilatada , Células-Tronco Pluripotentes Induzidas , Arritmias Cardíacas/genética , Cálcio , Cardiomiopatia Dilatada/genética , Humanos , Miócitos Cardíacos , Troponina T/genética , Troponina T/farmacologia
7.
Pediatr Res ; 92(3): 783-790, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34750523

RESUMO

BACKGROUND: Medical simulation training requires realistic simulators with high fidelity. This prospective multi-center study investigated anatomic precision, physiologic characteristics, and fidelity of four commercially available very low birth weight infant simulators. METHODS: We measured airway angles and distances in the simulators Premature AirwayPaul (SIMCharacters), Premature Anne (Laerdal Medical), Premie HAL S2209 (Gaumard), and Preterm Baby (Lifecast Body Simulation) using computer tomography and compared these to human cadavers of premature stillbirths. The simulators' physiologic characteristics were tested, and highly experienced experts rated their physical and functional fidelity. RESULTS: The airway angles corresponded to those of the reference cadavers in three simulators. The nasal inlet to glottis distance and the mouth aperture to glottis distance were only accurate in one simulator. All simulators had airway resistances up to 20 times higher and compliances up to 19 times lower than published reference values. Fifty-six highly experienced experts gave three simulators (Premature AirwayPaul: 5.1 ± 1.0, Premature Anne 4.9 ± 1.1, Preterm Baby 5.0 ± 1.0) good overall ratings and one simulator (Premie HAL S2209: 2.8 ± 1.0) an unfavorable rating. CONCLUSION: The simulator physiology deviated significantly from preterm infants' reference values concerning resistance and compliance, potentially promoting a wrong ventilation technique. IMPACT: Very low birth weight infant simulators showed physiological properties far deviating from corresponding patient reference values. Only ventilation with very high peak pressure achieved tidal volumes in the simulators, as aimed at in very low birth weight infants, potentially promoting a wrong ventilation technique. Compared to very low birth weight infant cadavers, most tested simulators accurately reproduced the anatomic angular relationships, but their airway dimensions were relatively too large for the represented body. The more professional experience the experts had, the lower they rated the very low birth weight infant simulators.


Assuntos
Recém-Nascido Prematuro , Treinamento por Simulação , Cadáver , Humanos , Lactente , Recém-Nascido , Recém-Nascido de muito Baixo Peso , Estudos Prospectivos , Treinamento por Simulação/métodos
8.
Eur J Clin Microbiol Infect Dis ; 41(4): 663-669, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35079932

RESUMO

Clinical and laboratory data on newly described staphylococcal species is rare, which hampers decision-making when such pathogens are detected in clinical specimens. Here, we describe Staphylococcus massiliensis detected in three patients at a university hospital in southwest Germany. We report the discrepancy of microbiological findings between matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, 16S-rRNA polymerase chain reaction, and whole-genome sequencing for all three isolates. Our findings highlight the diagnostic pitfalls pertinent to novel and non-model organisms in daily microbiological practice, in whom the correct identification is dependent on database accuracy.


Assuntos
Hemocultura , Staphylococcus , Humanos , RNA Ribossômico 16S/genética , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
9.
Int J Mol Sci ; 22(14)2021 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-34299089

RESUMO

The cytoskeletal protein vimentin is secreted under various physiological conditions. Extracellular vimentin exists primarily in two forms: attached to the outer cell surface and secreted into the extracellular space. While surface vimentin is involved in processes such as viral infections and cancer progression, secreted vimentin modulates inflammation through reduction of neutrophil infiltration, promotes bacterial elimination in activated macrophages, and supports axonal growth in astrocytes through activation of the IGF-1 receptor. This receptor is overexpressed in cancer cells, and its activation pathway has significant roles in general cellular functions. In this study, we investigated the functional role of extracellular vimentin in non-tumorigenic (MCF-10a) and cancer (MCF-7) cells through the evaluation of its effects on cell migration, proliferation, adhesion, and monolayer permeability. Upon treatment with extracellular recombinant vimentin, MCF-7 cells showed increased migration, proliferation, and adhesion, compared to MCF-10a cells. Further, MCF-7 monolayers showed reduced permeability, compared to MCF-10a monolayers. It has been shown that the receptor binding domain of SARS-CoV-2 spike protein can alter blood-brain barrier integrity. Surface vimentin also acts as a co-receptor between the SARS-CoV-2 spike protein and the cell-surface angiotensin-converting enzyme 2 receptor. Therefore, we also investigated the permeability of MCF-10a and MCF-7 monolayers upon treatment with extracellular recombinant vimentin, and its modulation of the SARS-CoV-2 receptor binding domain. These findings show that binding of extracellular recombinant vimentin to the cell surface enhances the permeability of both MCF-10a and MCF-7 monolayers. However, with SARS-CoV-2 receptor binding domain addition, this effect is lost with MCF-7 monolayers, as the extracellular vimentin binds directly to the viral domain. This defines an influence of extracellular vimentin in SARS-CoV-2 infections.


Assuntos
Neoplasias da Mama/patologia , Mama/patologia , Permeabilidade da Membrana Celular , Matriz Extracelular/metabolismo , Glicoproteína da Espícula de Coronavírus/metabolismo , Vimentina/metabolismo , Mama/metabolismo , Neoplasias da Mama/genética , Neoplasias da Mama/metabolismo , Células Cultivadas , Feminino , Humanos , Domínios Proteicos , Glicoproteína da Espícula de Coronavírus/genética , Vimentina/genética
10.
Int J Mol Sci ; 22(21)2021 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-34769382

RESUMO

The adhesion of Staphylococcus aureus to abiotic surfaces is crucial for establishing device-related infections. With a high number of single-cell force spectroscopy measurements with genetically modified S. aureus cells, this study provides insights into the adhesion process of the pathogen to abiotic surfaces of different wettability. Our results show that S. aureus utilizes different cell wall molecules and interaction mechanisms when binding to hydrophobic and hydrophilic surfaces. We found that covalently bound cell wall proteins strongly interact with hydrophobic substrates, while their contribution to the overall adhesion force is smaller on hydrophilic substrates. Teichoic acids promote adhesion to hydrophobic surfaces as well as to hydrophilic surfaces. This, however, is to a lesser extent. An interplay of electrostatic effects of charges and protein composition on bacterial surfaces is predominant on hydrophilic surfaces, while it is overshadowed on hydrophobic surfaces by the influence of the high number of binding proteins. Our results can help to design new models of bacterial adhesion and may be used to interpret the adhesion of other microorganisms with similar surface properties.


Assuntos
Aderência Bacteriana , Biofilmes/crescimento & desenvolvimento , Silício/metabolismo , Staphylococcus aureus/metabolismo , Interações Hidrofóbicas e Hidrofílicas , Staphylococcus aureus/genética , Staphylococcus aureus/crescimento & desenvolvimento , Propriedades de Superfície
11.
Crit Care Med ; 48(6): e489-e497, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32317603

RESUMO

OBJECTIVES: Tracheal intubation in critically ill children with shock poses a risk of hemodynamic compromise. Ketamine has been considered the drug of choice for induction in these patients, but limited data exist. We investigated whether the administration of ketamine for tracheal intubation in critically ill children with or without shock was associated with fewer adverse hemodynamic events compared with other induction agents. We also investigated if there was a dose dependence for any association between ketamine use and adverse hemodynamic events. DESIGN: We performed a retrospective analysis using prospectively collected observational data from the National Emergency Airway Registry for Children database from 2013 to 2017. SETTING: Forty international PICUs participating in the National Emergency Airway Registry for Children. PATIENTS: Critically ill children 0-17 years old who underwent tracheal intubation in a PICU. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The association between ketamine exposure as an induction agent and the occurrence of adverse hemodynamic events during tracheal intubation including dysrhythmia, hypotension, and cardiac arrest was evaluated. We used multivariable logistic regression to account for patient, provider, and practice factors with robust SEs to account for clustering by sites. Of 10,750 tracheal intubations, 32.0% (n = 3,436) included ketamine as an induction agent. The most common diagnoses associated with ketamine use were sepsis and/or shock (49.7%). After adjusting for potential confounders and sites, ketamine use was associated with fewer hemodynamic tracheal intubation associated adverse events compared with other agents (adjusted odds ratio, 0.74; 95% CI, 0.58-0.95). The interaction term between ketamine use and indication for shock was not significant (p = 0.11), indicating ketamine effect to prevent hemodynamic adverse events is consistent in children with or without shock. CONCLUSIONS: Ketamine use for tracheal intubation is associated with fewer hemodynamic tracheal intubation-associated adverse events.


Assuntos
Analgésicos/uso terapêutico , Hemodinâmica/efeitos dos fármacos , Intubação Intratraqueal/métodos , Ketamina/uso terapêutico , Choque/epidemiologia , Adolescente , Fatores Etários , Analgésicos/administração & dosagem , Analgésicos/efeitos adversos , Criança , Pré-Escolar , Estado Terminal , Feminino , Humanos , Lactente , Recém-Nascido , Unidades de Terapia Intensiva Pediátrica , Ketamina/administração & dosagem , Ketamina/efeitos adversos , Masculino , Estudos Retrospectivos
12.
Am J Perinatol ; 37(14): 1417-1424, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-31365934

RESUMO

OBJECTIVE: This study aimed to examine the association between team stress level and adverse tracheal intubation (TI)-associated events during neonatal intubations. STUDY DESIGN: TIs from 10 academic neonatal intensive care units were analyzed. Team stress level was rated immediately after TI using a 7-point Likert scale (1 = high stress). Associations among team stress, adverse TI-associated events, and TI characteristics were evaluated. RESULT: In this study, 208 of 2,009 TIs (10%) had high stress levels (score < 4). Oxygenation failure, hemodynamic instability, and family presence were associated with high stress level. Video laryngoscopy and premedication were associated with lower stress levels. High stress level TIs were associated with adverse TI-associated event rates (31 vs. 16%, p < 0.001), which remained significant after adjusting for potential confounders including patient, provider, and practice factors associated with high stress (odds ratio: 1.90, 96% confidence interval: 1.36-2.67, p < 0.001). CONCLUSION: High team stress levels during TI were more frequently reported among TIs with adverse events.


Assuntos
Unidades de Terapia Intensiva Neonatal , Intubação Intratraqueal/métodos , Equipe de Assistência ao Paciente , Estresse Psicológico , Competência Clínica/normas , Feminino , Humanos , Recém-Nascido , Intubação Intratraqueal/efeitos adversos , Laringoscopia , Masculino , Pré-Medicação , Estudos Retrospectivos , Análise e Desempenho de Tarefas , Estados Unidos
13.
Pediatr Crit Care Med ; 20(1): 1-8, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30407953

RESUMO

OBJECTIVES: It is unknown if variation in tracheal intubation practice and outcomes exist across PICUs in different geographical regions. We hypothesized there would be differences in the process of care and adverse outcomes for tracheal intubation across PICUs in six different geographical regions (New Zealand, Japan, Singapore, Germany, India, and North America). DESIGN: Prospective multicenter pediatric tracheal intubation database (National Emergency Airway Registry for Children) SETTING:: Six non-North American (International) and 36 North American PICUs. EVENTS: All PICU tracheal intubation encounters from July 2014 to June 2017 MEASUREMENTS AND MAIN RESULTS:: Adverse tracheal intubation-associated events and desaturation occurrence (oxygen saturation < 80%) were evaluated. A total of 1,134 and 9,376 TIs from International and North American PICUs were reported, respectively: primary tracheal intubation 9,060, endotracheal tube change 1,450. The proportion of tracheal intubations for endotracheal tube change was greater in International PICUs (37% vs 11%; p < 0.001). Median age for International tracheal intubations was younger compared with North America (0 yr [interquartile range, 0-2 yr] vs 1 yr (0-7 yr); p < 0.001). Among primary tracheal intubations, the most common indication was respiratory (International 67%, North American 63%; p = 0.049). Direct laryngoscopy was the most common device in both International (86%) and North American (74%) tracheal intubations. Occurrence of any adverse tracheal intubation-associated event was New Zealand 8%, Japan 17%, Singapore 9%, Germany 17%, and India 6%; International 11% versus North American 14%; p value equals to 0.003. Desaturation was reported less commonly in International PICUs: 13% versus North American 17%; p equals to 0.001. International PICUs used cuffed endotracheal tube less often (52% vs 95%; p < 0.001). Proportion of cuffed endotracheal tube use per PICU was inversely correlated with the rate of tube change (r = -0.67; p < 0.001). CONCLUSIONS: There were both similarities and differences in tracheal intubation practice and outcomes across international PICUs. Fewer adverse tracheal intubation-associated events were reported from International versus North American PICUs. International PICUs used cuffed endotracheal tube less often and had higher proportion of endotracheal tube change.


Assuntos
Unidades de Terapia Intensiva Pediátrica/estatística & dados numéricos , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/métodos , Adolescente , Fatores Etários , Criança , Pré-Escolar , Feminino , Saúde Global , Humanos , Lactente , Recém-Nascido , Laringoscopia/métodos , Masculino , Oxigênio/sangue , Estudos Prospectivos , Características de Residência
14.
Angew Chem Int Ed Engl ; 58(37): 12883-12886, 2019 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-31339633

RESUMO

Glycidyl tosylate appears to be a non-polymerizable epoxide when nucleophilic initiators are used because of the excellent leaving group properties of the tosylate. However, using the monomer-activated mechanism, this unusual monomer can be copolymerized with ethylene oxide (EO) and propylene oxide (PO), respectively, yielding copolymers with 7-25 % incorporated tosylate-moieties. The microstructure of the copolymers was investigated via in situ 1 H NMR spectroscopy, and the reactivity ratios of the copolymerizations have been determined. Quantitative nucleophilic substitution of the tosylate-moiety is demonstrated for several examples. This new structure provides access to a library of functionalized polyethers that cannot be synthesized by conventional oxyanionic polymerization.

15.
Pediatr Crit Care Med ; 19(2): 106-114, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29140970

RESUMO

OBJECTIVES: External laryngeal manipulation is a commonly used maneuver to improve visualization of the glottis during tracheal intubation in children. However, the effectiveness to improve tracheal intubation attempt success rate in the nonanesthesia setting is not clear. The study objective was to evaluate the association between external laryngeal manipulation use and initial tracheal intubation attempt success in PICUs. DESIGN: A retrospective observational study using a multicenter emergency airway quality improvement registry. SETTING: Thirty-five PICUs within general and children's hospitals (29 in the United States, three in Canada, one in Japan, one in Singapore, and one in New Zealand). PATIENTS: Critically ill children (< 18 years) undergoing initial tracheal intubation with direct laryngoscopy in PICUs between July 1, 2010, and December 31, 2015. MEASUREMENTS AND MAIN RESULTS: Propensity score-matched analysis was performed to evaluate the association between external laryngeal manipulation and initial attempt success while adjusting for underlying differences in patient and clinical care factors: age, obesity, tracheal intubation indications, difficult airway features, provider training level, and neuromuscular blockade use. External laryngeal manipulation was defined as any external force to the neck during laryngoscopy. Of the 7,825 tracheal intubations, the initial tracheal intubation attempt was successful in 1,935/3,274 intubations (59%) with external laryngeal manipulation and 3,086/4,551 (68%) without external laryngeal manipulation (unadjusted odds ratio, 0.69; 95% CI, 0.62-0.75; p < 0.001). In propensity score-matched analysis, external laryngeal manipulation remained associated with lower initial tracheal intubation attempt success (adjusted odds ratio, 0.93; 95% CI, 0.90-0.95; p < 0.001). CONCLUSIONS: External laryngeal manipulation during direct laryngoscopy was associated with lower initial tracheal intubation attempt success in critically ill children, even after adjusting for underlying differences in patient factors and provider levels. The indiscriminate use of external laryngeal manipulation cannot be recommended.


Assuntos
Estado Terminal/terapia , Intubação Intratraqueal/métodos , Laringoscopia/métodos , Canadá , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Unidades de Terapia Intensiva Pediátrica , Japão , Laringe , Masculino , Nova Zelândia , Pontuação de Propensão , Melhoria de Qualidade , Sistema de Registros , Estudos Retrospectivos , Singapura , Estados Unidos
16.
BMC Pediatr ; 15: 18, 2015 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-25884954

RESUMO

BACKGROUND: Since an objective description is essential to determine infant's postnatal condition and efficacy of interventions, two scores were suggested in the past but weren't tested yet: The Specified-Apgar uses the 5 items of the conventional Apgar score; however describes the condition regardless of gestational age (GA) or resuscitative interventions. The Expanded-Apgar measures interventions needed to achieve this condition. We hypothesized that the combination of both (Combined-Apgar) describes postnatal condition of preterm infants better than either of the scores alone. METHODS: Scores were assessed in preterm infants below 32 completed weeks of gestation. Data were prospectively collected in 20 NICU in 12 countries. Prediction of poor outcome (death, severe/moderate BPD, IVH, CPL and ROP) was used as a surrogate parameter to compare the scores. To compare predictive value the AUC for the ROC was calculated. RESULTS: Of 2150 eligible newborns, data on 1855 infants with a mean GA of 28(6/7) ± 2(3/7) weeks were analyzed. At 1 minute, the Combined-Apgar was significantly better in predicting poor outcome than the Specified- or Expanded-Apgar alone. Of infants with a very low score at 5 or 10 minutes 81% or 100% had a poor outcome, respectively. In these infants the relative risk (RR) for perinatal mortality was 24.93 (13.16-47.20) and 31.34 (15.91-61.71), respectively. CONCLUSION: The Combined-Apgar allows a more appropriate description of infant's condition under conditions of modern neonatal care. It should be used as a tool for better comparison of group of infants and postnatal interventions. TRIAL REGISTRATION: clinicaltrials.gov Protocol Registration System (NCT00623038). Registered 14 February 2008.


Assuntos
Índice de Apgar , Recém-Nascido Prematuro , Salas de Parto , Feminino , Idade Gestacional , Humanos , Lactente , Mortalidade Infantil , Recém-Nascido , Gravidez , Prognóstico , Fatores de Risco
17.
Biophys J ; 107(5): 1082-1089, 2014 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-25185544

RESUMO

We have used atomic-force microscopy (AFM) to probe the effect of peptidoglycan crosslinking reduction on the elasticity of the Staphylococcus aureus cell wall, which is of particular interest as a target for antimicrobial chemotherapy. Penicillin-binding protein 4 (PBP4) is a nonessential transpeptidase, required for the high levels of peptidoglycan crosslinking characteristic of S. aureus. Importantly, this protein is essential for ß-lactam resistance in community-acquired, methicillin-resistant S. aureus (MRSA) strains but not in hospital-acquired MRSA strains. Using AFM in a new mode for recording force/distance curves, we observed that the absence of PBP4, and the concomitant reduction of the peptidoglycan crosslinking, resulted in a reduction in stiffness of the S. aureus cell wall. Importantly, the reduction in cell wall stiffness in the absence of PBP4 was observed both in community-acquired and hospital-acquired MRSA strains, indicating that high levels of peptidoglycan crosslinking modulate the overall structure and mechanical properties of the S. aureus cell envelope in both types of clinically relevant strains. Additionally, we were able to show that the applied method enables the separation of cell wall properties and turgor pressure.


Assuntos
Parede Celular/química , Peptidoglicano/química , Staphylococcus aureus/química , Cromatografia Líquida de Alta Pressão , Módulo de Elasticidade , Microscopia de Força Atômica , Microscopia de Fluorescência , Proteínas de Ligação às Penicilinas/química
18.
Int J Med Microbiol ; 304(7): 777-86, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25034858

RESUMO

Livestock-associated methicillin-resistant Staphylococcus aureus (LA-MRSA) of the clonal complex (CC) 398 became primarily known as colonizers of livestock animals. In the past few years, they have been increasingly introduced into hospitals with subsequent emergence of human infections. However, the (re-)adaptation to the human host is only incompletely understood. This study aimed to assess virulence properties of LA-MRSA CC398 by functional modeling of infection and colonization processes. A selection of 15 human LA-MRSA CC398 isolates and 11 pig-colonizing isolates were characterized regarding their virulence capacities and compared with human isolates of hospital-acquired (HA)-MRSA (CC5, CC22 and CC45) and community-associated (CA)-MRSA (CC8, CC30 and CC80) clonal lineages. Our investigations demonstrated that LA-MRSA CC398 adhered less efficient to human cells and human/bovine plasma fibronectin than CA-MRSA and HA-MRSA isolates. In contrast, the LA-MRSA CC398 isolates revealed a high cytotoxic potential comparable to certain CA-MRSA. Comparing the most prevalent LA-MRSA CC398 spa types (t011, t034, t108), isolates associated with spa t108 showed an increased adhesive and invasive potential paired with an increased ability to evade phagocytosis. The results underline both the pathogenic potential of LA-MRSA in general and the heterogeneity within the CC398 clade regarding the virulence characteristics of CC398 subpopulations. Assuming an ongoing (re-)adaptation to the human host combined with a huge reservoir of LA-MRSA CC398 in livestock and constant zoonotic transmission, the LA-MRSA CC398 lineage has the potential to pose a serious threat to human health.


Assuntos
Infecções Comunitárias Adquiridas/microbiologia , Infecção Hospitalar/microbiologia , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Infecções Estafilocócicas/microbiologia , Infecções Estafilocócicas/veterinária , Doenças dos Suínos/microbiologia , Animais , Aderência Bacteriana , Células Epiteliais/microbiologia , Fibronectinas/metabolismo , Humanos , Staphylococcus aureus Resistente à Meticilina/fisiologia , Ligação Proteica , Suínos , Virulência
19.
J Org Chem ; 79(23): 11750-8, 2014 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-25350833

RESUMO

An electrocyclic ring closure is the key step of an efficient one-pot method for the synthesis of pyrrole-2-carboxylates and -carboxamides from chalcones and glycine esters or amides. The 3,4-dihydro-2H-pyrrole intermediates generated in situ are oxidized to the corresponding pyrroles by stoichiometric oxidants or by catalytic copper(II) and air in moderate to high yields. A wide range of functional groups are tolerated, and further combination with an in situ bromination gives access to polyfunctional pyrrole scaffolds.


Assuntos
Prolina/análogos & derivados , Pirróis/síntese química , Catálise , Cobre/química , Ciclização , Eletroquímica , Ésteres , Oxirredução , Prolina/síntese química , Prolina/química , Pirróis/química , Estereoisomerismo
20.
J Microbiol Methods ; 223: 106974, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38880389

RESUMO

Microscopy as a basic diagnostic method cannot be used everywhere globally. Validity of slide reading was tested on torch-modified microscopes. Experienced microscopists handled the modification without prior standard-adaptation. In contrast, microscopist-trainees required more detailed instructions to get acquainted with this new technique. The overall results encourage further, setting-specific validation.


Assuntos
Microscopia , Microscopia/métodos , Microscopia/instrumentação , Estudo de Prova de Conceito , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA