Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Neurosurg Focus ; 38(6): E9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26030709

RESUMO

OBJECT: Anterior nuclear (AN) stimulation has been reported to reduce the frequency of seizures, in some cases dramatically; however, it has not been approved by the US Food and Drug Administration. The anterior nucleus is difficult to target because of its sequestered location, partially surrounded by the ventricle. It has traditionally been targeted by using transventricular or lateral transcortical routes. Here, the authors report a novel approach to targeting the anterior nucleus and neurophysiologically confirming effective stimulation of the target, namely evoked potentials in the hippocampus. METHODS: Bilateral AN 3389 electrodes were placed in a novel trajectory followed by bilateral hippocampal 3391 electrodes from a posterior trajectory. Each patient was implanted bilaterally with a Medtronic Activa PC+S device under an investigational device exemption approval. Placement was confirmed with CT. AN stimulation-induced hippocampal evoked potentials were measured to functionally confirm placement in the anterior nucleus. RESULTS: Two patients had implantations by way of a novel AN trajectory with concomitant hippocampal electrodes. There were no lead misplacements. Postoperative stimulation of the anterior nucleus with a PC+S device elicited evoked potentials in the hippocampus. Thus far, both patients have reported a > 50% improvement in seizure frequency. CONCLUSIONS: Placing AN electrodes posteriorly may provide a safer trajectory than that used for traditionally placed AN electrodes. In addition, with a novel battery that is capable of electroencephalographic recording, evoked potentials can be used to functionally assess the Papez circuit. This treatment paradigm may offer increased AN stimulation efficacy for medically intractable epilepsy by assessing functional placement more effectively and thus far has proven safe.


Assuntos
Núcleos Anteriores do Tálamo/fisiologia , Estimulação Encefálica Profunda/métodos , Epilepsias Parciais/terapia , Hipocampo/fisiopatologia , Adulto , Eletrodos Implantados , Feminino , Humanos , Masculino
2.
Mayo Clin Proc ; 93(1): 16-24, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29304919

RESUMO

OBJECTIVE: To determine adverse event rates for adult cranial neuro-oncologic surgeries performed at a high-volume quaternary academic center and assess the impact of resident participation on perioperative complication rates. PATIENTS AND METHODS: All adult patients undergoing neurosurgical intervention for an intracranial neoplastic lesion between January 1, 2009, and December 31, 2013, were included. Cases were categorized as biopsy, extra-axial/skull base, intra-axial, or transsphenoidal. Complications were categorized as neurologic, medical, wound, mortality, or none and compared for patients managed by a chief resident vs a consultant neurosurgeon. RESULTS: A total of 6277 neurosurgical procedures for intracranial neoplasms were performed. After excluding radiosurgical procedures and pediatric patients, 4151 adult patients who underwent 4423 procedures were available for analysis. Complications were infrequent, with overall rates of 9.8% (435 of 4423 procedures), 1.7% (73 of 4423), and 1.4% (63 of 4423) for neurologic, medical, and wound complications, respectively. The rate of perioperative mortality was 0.3% (14 of 4423 procedures). Case performance and management by a chief resident did not negatively impact outcome. CONCLUSION: In our large-volume brain tumor practice, rates of complications were low, and management of cases by chief residents in a semiautonomous manner did not negatively impact surgical outcomes.


Assuntos
Centros Médicos Acadêmicos/estatística & dados numéricos , Neoplasias Encefálicas/mortalidade , Neoplasias Encefálicas/cirurgia , Sobreviventes de Câncer/estatística & dados numéricos , Radiocirurgia/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Estados Unidos
3.
J Neurosurg ; 106(4): 626-32, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17432714

RESUMO

OBJECT: The object of this study was to assess the results of unilateral deep brain stimulation (DBS) of the subthalamic nucleus (STN) for management of advanced Parkinson disease (PD). METHODS: A clinical series of 24 patients (mean age 71 years, range 56-80 years) with medically intractable PD, who were undergoing unilateral magnetic resonance imaging-targeted, electrophysiologically guided STN DBS, completed a battery of qualitative and quantitative outcome measures preoperatively (baseline) and postoperatively, using a modified Core Assessment Program for Intracerebral Transplantations protocol. The mean follow-up period was 9 months. Statistically significant improvement was observed in the Unified Parkinson's Disease Rating Scale (UPDRS) Part II score (18%), the total UPDRS PART III score (31%), the contralateral UPDRS Part III score (63%), and scores for axial motor features (19%), contralateral tremor (88%), rigidity (60%), bradykinesia (54%), and dyskinesia (69%), as well as the Parkinson's Disease Quality of Life questionnaire score (15%) in the on-stimulation state compared with baseline. Ipsilateral symptoms improved by approximately 15% or less. Performance on the Purdue pegboard test improved in the contralateral hand in the on-stimulation state compared with the off-stimulation state (38%, p < 0.05). The daily levodopa-equivalent dose was reduced by 21% (p = 0.018). Neuropsychological tests revealed an improvement in mental flexibility and a trend toward reduced letter fluency. There were no permanent surgical complications. Of the 16 participants with symmetrical disease, five required implantation of the DBS unit on the second side. CONCLUSIONS: Unilateral STN DBS is an effective and safe treatment for selected patients with advanced PD. Unilateral STN DBS provides improvement of contralateral motor symptoms of PD as well as quality of life, reduces requirements for medication, and possibly enhances mental flexibility. This method of surgical treatment may be associated with a reduced risk and may provide an alternative to bilateral STN DBS for PD, especially in older patients or patients with asymmetry of parkinsonism.


Assuntos
Estimulação Encefálica Profunda/métodos , Doença de Parkinson/terapia , Núcleo Subtalâmico , Idoso , Idoso de 80 Anos ou mais , Antiparkinsonianos/uso terapêutico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Índice de Gravidade de Doença , Resultado do Tratamento
4.
Spine (Phila Pa 1976) ; 41(13): E806-E813, 2016 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-26679880

RESUMO

STUDY DESIGN: Laboratory/animal-based proof of principle study. OBJECTIVE: To validate the accuracy of a magnetic resonance imaging (MRI)-guided stereotactic system for intraspinal electrode targeting and demonstrate the feasibility of such a system for controlling implantation of intraspinal electrodes. SUMMARY OF BACKGROUND DATA: Intraspinal microstimulation (ISMS) is an emerging preclinical therapy, which has shown promise for the restoration of motor function following spinal cord injury. However, targeting inaccuracy associated with existing electrode implantation techniques remains a major barrier preventing clinical translation of ISMS. METHODS: System accuracy was evaluated using a test phantom comprised of nine target locations. Targeting accuracy was determined by calculating the root mean square error between MRI-generated coordinates and actual frame coordinates required to reach the target positions. System performance was further validated in an anesthetized pig model by performing MRI-guided intraspinal electrode implantation and stimulation followed by computed tomography of electrode location. Finally, system compatibility with a commercially available microelectrode array was demonstrated by implanting the array and applying a selection of stimulation amplitudes that evoked hind limb responses. RESULTS: The root mean square error between actual frame coordinates and software coordinates, both acquired using the test phantom, was 1.09 ±â€Š0.20 mm. Postoperative computed tomography in the anesthetized pig confirmed spatially accurate electrode placement relative to preoperative MRI. Additionally, MRI-guided delivery of a microwire electrode followed by ISMS evoked repeatable electromyography responses in the biceps femoris muscle. Finally, delivery of a microelectrode array produced repeatable and graded hind limb evoked movements. CONCLUSION: We present a novel frame-based stereotactic system for targeting and delivery of intraspinal instrumentation. This system utilizes MRI guidance to account for variations in anatomy between subjects, thereby improving upon existing ISMS electrode implantation techniques. LEVEL OF EVIDENCE: N/A.


Assuntos
Terapia por Estimulação Elétrica/métodos , Eletrodos Implantados , Imageamento por Ressonância Magnética/métodos , Medula Espinal/diagnóstico por imagem , Técnicas Estereotáxicas , Animais , Imageamento por Ressonância Magnética/instrumentação , Masculino , Microeletrodos , Traumatismos da Medula Espinal/diagnóstico por imagem , Traumatismos da Medula Espinal/terapia , Técnicas Estereotáxicas/instrumentação , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA