Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Int J Obes (Lond) ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38926461

RESUMO

BACKGROUND/OBJECTIVES: Weight loss outcomes vary individually. Magnetic resonance imaging (MRI)-based evaluation of adipose tissue (AT) might help to identify AT characteristics that predict AT loss. This study aimed to assess the impact of an 8-week low-calorie diet (LCD) on different AT depots and to identify predictors of short-term AT loss using MRI in adults with obesity. METHODS: Eighty-one adults with obesity (mean BMI 34.08 ± 2.75 kg/m², mean age 46.3 ± 10.97 years, 49 females) prospectively underwent baseline MRI (liver dome to femoral head) and anthropometric measurements (BMI, waist-to-hip-ratio, body fat), followed by a post-LCD-examination. Visceral and subcutaneous AT (VAT and SAT) volumes and AT fat fraction were extracted from the MRI data. Apparent lipid volumes based on MRI were calculated as approximation for the lipid contained in the AT. SAT and VAT volumes were subdivided into equidistant thirds along the craniocaudal axis and normalized by length of the segmentation. T-tests compared baseline and follow-up measurements and sex differences. Effect sizes on subdivided AT volumes were compared. Spearman Rank correlation explored associations between baseline parameters and AT loss. Multiple regression analysis identified baseline predictors for AT loss. RESULTS: Following the LCD, participants exhibited significant weight loss (11.61 ± 3.07 kg, p < 0.01) and reductions in all MRI-based AT parameters (p < 0.01). Absolute SAT loss exceeded VAT loss, while relative apparent lipid loss was higher in VAT (both p < 0.01). The lower abdominopelvic third showed the most significant SAT and VAT reduction. The predictor of most AT and apparent lipid losses was the normalized baseline SAT volume in the lower abdominopelvic third, with smaller volumes favoring greater AT loss (p < 0.01 for SAT and VAT loss and SAT apparent lipid volume loss). CONCLUSIONS: The LCD primarily reduces lower abdominopelvic SAT and VAT. Furthermore, lower abdominopelvic SAT volume was detected as a potential predictor for short-term AT loss in persons with obesity.

2.
Magn Reson Med ; 2024 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-39155406

RESUMO

PURPOSE: To develop a Dixon-based B 0 $$ {\mathrm{B}}_0 $$ self-navigation approach to estimate and correct temporal B 0 $$ {\mathrm{B}}_0 $$ variations in radial stack-of-stars gradient echo imaging for quantitative body MRI. METHODS: The proposed method estimates temporal B 0 $$ {\mathrm{B}}_0 $$ variations using a B 0 $$ {\mathrm{B}}_0 $$ self-navigator estimated by a graph-cut-based water-fat separation algorithm on the oversampled k-space center. The B 0 $$ {\mathrm{B}}_0 $$ self-navigator was employed to correct for phase differences between radial spokes (one-dimensional [1D] correction) and to perform a motion-resolved reconstruction to correct spatiotemporal pseudo-periodic B 0 $$ {\mathrm{B}}_0 $$ variations (three-dimensional [3D] correction). Numerical simulations, phantom experiments and in vivo neck scans were performed to evaluate the effects of temporal B 0 $$ {\mathrm{B}}_0 $$ variations on the field-map, proton density fat fraction (PDFF) and T 2 ∗ $$ {\mathrm{T}}_2^{\ast } $$ map, and to validate the proposed method. RESULTS: Temporal B 0 $$ {\mathrm{B}}_0 $$ variations were found to cause signal loss and phase shifts on the multi-echo images that lead to an underestimation of T 2 ∗ $$ {\mathrm{T}}_2^{\ast } $$ , while PDFF mapping was less affected. The B 0 $$ {\mathrm{B}}_0 $$ self-navigator captured slowly varying temporal B 0 $$ {\mathrm{B}}_0 $$ drifts and temporal variations caused by respiratory motion. While the 1D correction effectively corrected B 0 $$ {\mathrm{B}}_0 $$ drifts in phantom studies, it was insufficient in vivo due to 3D spatially varying temporal B 0 $$ {\mathrm{B}}_0 $$ variations with amplitudes of up to 25 Hz at 3 T near the lungs. The proposed 3D correction locally improved the correction of field-map and T 2 ∗ $$ {\mathrm{T}}_2^{\ast } $$ and reduced image artifacts. CONCLUSION: Temporal B 0 $$ {\mathrm{B}}_0 $$ variations particularly affect T 2 ∗ $$ {\mathrm{T}}_2^{\ast } $$ mapping in radial stack-of-stars imaging. The self-navigation approach can be applied without modifying the MR acquisition to correct for B 0 $$ {\mathrm{B}}_0 $$ drift and physiological motion-induced B 0 $$ {\mathrm{B}}_0 $$ variations, especially in the presence of fat.

3.
NMR Biomed ; : e5181, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38830747

RESUMO

PURPOSE: The aim of this work is to develop an ω-3 fatty acid fraction mapping method at 3 T based on a chemical shift encoding model, to assess its performance in a phantom and in vitro study, and to further demonstrate its feasibility in vivo. METHODS: A signal model was heuristically derived based on spectral appearance and theoretical considerations of the corresponding molecular structures to differentiate between ω-3 and non-ω-3 fatty acid substituents in triacylglycerols in addition to the number of double bonds (ndb), the number of methylene-interrupted double bonds (nmidb), and the mean fatty acid chain length (CL). First, the signal model was validated using single-voxel spectroscopy and a time-interleaved multi-echo gradient-echo (TIMGRE) sequence in gas chromatography-mass spectrometry (GC-MS)-calibrated oil phantoms. Second, the TIMGRE-based method was validated in vitro in 21 adipose tissue samples with corresponding GC-MS measurements. Third, an in vivo feasibility study was performed for the TIMGRE-based method in the gluteal region of two healthy volunteers. Phantom and in vitro data was analyzed using a Bland-Altman analysis. RESULTS: Compared with GC-MS, MRS showed in the phantom study significant correlations in estimating the ω-3 fraction (p < 0.001), ndb (p < 0.001), nmidb (p < 0.001), and CL (p = 0.001); MRI showed in the phantom study significant correlations (all p < 0.001) for the ω-3 fraction, ndb, and nmidb, but no correlation for CL. Also in the in vitro study, significant correlations (all p < 0.001) between MRI and GC-MS were observed for the ω-3 fraction, ndb, and nmidb, but not for CL. An exemplary ROI measurement in vivo in the gluteal subcutaneous adipose tissue yielded (mean ± standard deviation) 0.8% ± 1.9% ω-3 fraction. CONCLUSION: The present study demonstrated strong correlations between gradient-echo imaging-based ω-3 fatty acid fraction mapping and GC-MS in the phantom and in vitro study. Furthermore, feasibility was demonstrated for characterizing adipose tissue in vivo.

4.
NMR Biomed ; 37(9): e5147, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38561247

RESUMO

Partial Fourier encoding is popular in single-shot (ss) diffusion-weighted (DW) echo planar imaging (EPI) because it enables a shorter echo time (TE) and, hence, improves the signal-to-noise-ratio. Motion during diffusion encoding causes k-space shifting and dispersion, which compromises the quality of the homodyne reconstruction. This work provides a comprehensive understanding of the artifacts in homodyne reconstruction of partial Fourier ss-DW-EPI data in the presence of motion-induced phase and proposes the motion-induced phase-corrected homodyne (mpc-hdyne) reconstruction method to ameliorate these artifacts. Simulations with different types of motion-induced phase were performed to provide an understanding of the potential artifacts that occur in the homodyne reconstruction of partial Fourier ss-DW-EPI data. To correct for the artifacts, the mpc-hdyne reconstruction is proposed. The algorithm recenters k-space, updates the partial Fourier factor according to detected global k-space shifts, and removes low-resolution nonlinear phase before the conventional homodyne reconstruction. The mpc-hdyne reconstruction is tested on both simulation and in vivo data. Motion-induced phase can cause signal overestimation, worm artifacts, and signal loss in partial Fourier ss-DW-EPI data with the conventional homodyne reconstruction. Simulation and in vivo data showed that the proposed mpc-hdyne reconstruction ameliorated artifacts, yielding higher quality DW images compared with conventional homodyne reconstruction. Based on the understanding of the artifacts in homodyne reconstruction of partial Fourier ss-DW-EPI data, the mpc-hdyne reconstruction was proposed and showed superior performance compared with the conventional homodyne reconstruction on both simulation and in vivo data.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Análise de Fourier , Fígado , Movimento (Física) , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Algoritmos , Artefatos , Simulação por Computador , Processamento de Imagem Assistida por Computador/métodos
5.
NMR Biomed ; 37(5): e5097, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38269568

RESUMO

PURPOSE: Liver T1 mapping techniques typically require long breath holds or long scan time in free-breathing, need correction for B 1 + inhomogeneities and process composite (water and fat) signals. The purpose of this work is to accelerate the multi-slice acquisition of liver water selective T1 (wT1) mapping in a single breath hold, improving the k-space sampling efficiency. METHODS: The proposed continuous inversion-recovery (IR) Look-Locker methodology combines a single-shot gradient echo spiral readout, Dixon processing and a dictionary-based analysis for liver wT1 mapping at 3 T. The sequence parameters were adapted to obtain short scan times. The influence of fat, B 1 + inhomogeneities and TE on the estimation of T1 was first assessed using simulations. The proposed method was then validated in a phantom and in 10 volunteers, comparing it with MRS and the modified Look-Locker inversion-recovery (MOLLI) method. Finally, the clinical feasibility was investigated by comparing wT1 maps with clinical scans in nine patients. RESULTS: The phantom results are in good agreement with MRS. The proposed method encodes the IR-curve for the liver wT1 estimation, is minimally sensitive to B 1 + inhomogeneities and acquires one slice in 1.2 s. The volunteer results confirmed the multi-slice capability of the proposed method, acquiring nine slices in a breath hold of 11 s. The present work shows robustness to B 1 + inhomogeneities ( wT 1 , No B 1 + = 1.07 wT 1 , B 1 + - 45.63 , R 2 = 0.99 ) , good repeatability ( wT 1 , 2 ° = 1 . 0 wT 1 , 1 ° - 2.14 , R 2 = 0.96 ) and is in better agreement with MRS ( wT 1 = 0.92 wT 1 MRS + 103.28 , R 2 = 0.38 ) than is MOLLI ( wT 1 MOLLI = 0.76 wT 1 MRS + 254.43 , R 2 = 0.44 ) . The wT1 maps in patients captured diverse lesions, thus showing their clinical feasibility. CONCLUSION: A single-shot spiral acquisition can be combined with a continuous IR Look-Locker method to perform rapid repeatable multi-slice liver water T1 mapping at a rate of 1.2 s per slice without a B 1 + map. The proposed method is suitable for nine-slice liver clinical applications acquired in a single breath hold of 11 s.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Abdome , Respiração , Imagens de Fantasmas , Reprodutibilidade dos Testes , Coração
6.
NMR Biomed ; : e5216, 2024 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-39099162

RESUMO

PURPOSE: To develop and validate a data acquisition scheme combined with a motion-resolved reconstruction and dictionary-matching-based parameter estimation to enable free-breathing isotropic resolution self-navigated whole-liver simultaneous water-specific T 1 $$ {\mathrm{T}}_1 $$ ( wT 1 $$ {\mathrm{wT}}_1 $$ ) and T 2 $$ {\mathrm{T}}_2 $$ ( wT 2 $$ {\mathrm{wT}}_2 $$ ) mapping for the characterization of diffuse and oncological liver diseases. METHODS: The proposed data acquisition consists of a magnetization preparation pulse and a two-echo gradient echo readout with a radial stack-of-stars trajectory, repeated with different preparations to achieve different T 1 $$ {\mathrm{T}}_1 $$ and T 2 $$ {\mathrm{T}}_2 $$ contrasts in a fixed acquisition time of 6 min. Regularized reconstruction was performed using self-navigation to account for motion during the free-breathing acquisition, followed by water-fat separation. Bloch simulations of the sequence were applied to optimize the sequence timing for B 1 $$ {B}_1 $$ insensitivity at 3 T, to correct for relaxation-induced blurring, and to map T 1 $$ {\mathrm{T}}_1 $$ and T 2 $$ {\mathrm{T}}_2 $$ using a dictionary. The proposed method was validated on a water-fat phantom with varying relaxation properties and in 10 volunteers against imaging and spectroscopy reference values. The performance and robustness of the proposed method were evaluated in five patients with abdominal pathologies. RESULTS: Simulations demonstrate good B 1 $$ {B}_1 $$ insensitivity of the proposed method in measuring T 1 $$ {\mathrm{T}}_1 $$ and T 2 $$ {\mathrm{T}}_2 $$ values. The proposed method produces co-registered wT 1 $$ {\mathrm{wT}}_1 $$ and wT 2 $$ {\mathrm{wT}}_2 $$ maps with a good agreement with reference methods (phantom: wT 1 = 1 . 02 wT 1,ref - 8 . 93 ms , R 2 = 0 . 991 $$ {\mathrm{wT}}_1=1.02\kern0.1em {\mathrm{wT}}_{1,\mathrm{ref}}-8.93\kern0.1em \mathrm{ms},{R}^2=0.991 $$ ; wT 2 = 1 . 03 wT 2,ref + 0 . 73 ms , R 2 = 0 . 995 $$ {\mathrm{wT}}_2=1.03\kern0.1em {\mathrm{wT}}_{2,\mathrm{ref}}+0.73\kern0.1em \mathrm{ms},{R}^2=0.995 $$ ). The proposed wT 1 $$ {\mathrm{wT}}_1 $$ and wT 2 $$ {\mathrm{wT}}_2 $$ mapping exhibits good repeatability and can be robustly performed in patients with pathologies. CONCLUSIONS: The proposed method allows whole-liver wT 1 $$ {\mathrm{wT}}_1 $$ and wT 2 $$ {\mathrm{wT}}_2 $$ quantification with high accuracy at isotropic resolution in a fixed acquisition time during free-breathing.

7.
J Magn Reson Imaging ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662618

RESUMO

BACKGROUND: Recent multicenter, multivendor MRI-based R2* vs. liver iron concentration (LIC) calibrations (i.e., MCMV calibrations) may facilitate broad clinical dissemination of R2*-based LIC quantification. However, these calibrations are based on a centralized offline R2* reconstruction, and their applicability with vendor-provided R2* maps is unclear. PURPOSE: To determine R2* ranges of agreement between the centralized and three MRI vendors' R2* reconstructions. STUDY TYPE: Prospective. SUBJECTS: Two hundred and seven subjects (mean age 37.6 ± 19.6 years; 117 male) with known or suspected iron overload from four academic medical centers. FIELD STRENGTH/SEQUENCE: Standardized multiecho spoiled gradient echo sequence at 1.5 T and 3.0 T for R2* mapping and a multiple spin-echo sequence at 1.5 T for LIC quantification. MRI vendors: GE Healthcare, Philips Healthcare, and Siemens Healthineers. ASSESSMENT: R2* maps were generated using both the centralized and vendor reconstructions, and ranges of agreement were determined. R2*-LIC linear calibrations were determined for each site, field strength, and reconstruction and compared with the MCMV calibrations. STATISTICAL TESTS: Bland-Altman analysis to determine ranges of agreement. Linear regression, analysis of covariance F tests, and Tukey's multiple comparison testing to assess reproducibility of calibrations across sites and vendors. A P value <0.05 was considered significant. RESULTS: The upper limits of R2* ranges of agreement were approximately 500, 375, and 330 s-1 for GE, Philips, and Siemens reconstructions, respectively, at 1.5 T and approximately 700 and 800 s-1 for GE and Philips, respectively, at 3.0 T. Within the R2* ranges of agreement, vendor R2*-LIC calibrations demonstrated high reproducibility (no significant differences between slopes or intercepts; P ≥ 0.06) and agreed with the MCMV calibrations (overlapping 95% confidence intervals). DATA CONCLUSION: Based on the determined upper limits, R2* measurements obtained from vendor-provided R2* maps may be reliably and practically used to quantify LIC less than approximately 8-13 mg/g using the MCMV calibrations and similar acquisition parameters as this study. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 3.

8.
Eur Radiol ; 2024 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-39154315

RESUMO

OBJECTIVES: Evaluating the diagnostic feasibility of accelerated pulmonary MR imaging for detection and characterisation of pulmonary nodules with artificial intelligence-aided compressed sensing. MATERIALS AND METHODS: In this prospective trial, patients with benign and malignant lung nodules admitted between December 2021 and December 2022 underwent chest CT and pulmonary MRI. Pulmonary MRI used a respiratory-gated 3D gradient echo sequence, accelerated with a combination of parallel imaging, compressed sensing, and deep learning image reconstruction with three different acceleration factors (CS-AI-7, CS-AI-10, and CS-AI-15). Two readers evaluated image quality (5-point Likert scale), nodule detection and characterisation (size and morphology) of all sequences compared to CT in a blinded setting. Reader agreement was determined using the intraclass correlation coefficient (ICC). RESULTS: Thirty-seven patients with 64 pulmonary nodules (solid n = 57 [3-107 mm] part-solid n = 6 [ground glass/solid 8 mm/4-28 mm/16 mm] ground glass nodule n = 1 [20 mm]) were analysed. Nominal scan times were CS-AI-7 3:53 min; CS-AI-10 2:34 min; CS-AI-15 1:50 min. CS-AI-7 showed higher image quality, while quality remained diagnostic even for CS-AI-15. Detection rates of pulmonary nodules were 100%, 98.4%, and 96.8% for CS-AI factors 7, 10, and 15, respectively. Nodule morphology was best at the lowest acceleration and was inferior to CT in only 5% of cases, compared to 10% for CS-AI-10 and 23% for CS-AI-15. The nodule size was comparable for all sequences and deviated on average < 1 mm from the CT size. CONCLUSION: The combination of compressed sensing and AI enables a substantial reduction in the scan time of lung MRI while maintaining a high detection rate of pulmonary nodules. CLINICAL RELEVANCE STATEMENT: Incorporating compressed sensing and AI in pulmonary MRI achieves significant time savings without compromising nodule detection or characteristics. This advancement holds clinical promise, enhancing efficiency in lung cancer screening without sacrificing diagnostic quality. KEY POINTS: Lung cancer screening by MRI may be possible but would benefit from scan time optimisation. Significant scan time reduction, high detection rates, and preserved nodule characteristics were achieved across different acceleration factors. Integrating compressed sensing and AI in pulmonary MRI offers efficient lung cancer screening without compromising diagnostic quality.

9.
MAGMA ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38743376

RESUMO

PURPOSE: To investigate the effect of respiratory motion in terms of signal loss in prostate diffusion-weighted imaging (DWI), and to evaluate the usage of partial Fourier in a free-breathing protocol in a clinically relevant b-value range using both single-shot and multi-shot acquisitions. METHODS: A controlled breathing DWI acquisition was first employed at 3 T to measure signal loss from deep breathing patterns. Single-shot and multi-shot (2-shot) acquisitions without partial Fourier (no pF) and with partial Fourier (pF) factors of 0.75 and 0.65 were employed in a free-breathing protocol. The apparent SNR and ADC values were evaluated in 10 healthy subjects to measure if low pF factors caused low apparent SNR or overestimated ADC. RESULTS: Controlled breathing experiments showed a difference in signal coefficient of variation between shallow and deep breathing. In free-breathing single-shot acquisitions, the pF 0.65 scan showed a significantly (p < 0.05) higher apparent SNR than pF 0.75 and no pF in the peripheral zone (PZ) of the prostate. In the multi-shot acquisitions in the PZ, pF 0.75 had a significantly higher apparent SNR than 0.65 pF and no pF. The single-shot pF 0.65 scan had a significantly lower ADC than single-shot no pF. CONCLUSION: Deep breathing patterns can cause intravoxel dephasing in prostate DWI. For single-shot acquisitions at a b-value of 800 s/mm2, any potential risks of motion-related artefacts at low pF factors (pF 0.65) were outweighed by the increase in signal from a lower TE, as shown by the increase in apparent SNR. In multi-shot acquisitions however, the minimum pF factor should be larger, as shown by the lower apparent SNR at low pF factors.

10.
Acta Radiol ; 65(7): 716-723, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38872362

RESUMO

BACKGROUND: With rising breast augmentations worldwide, there is an increasing clinical need for an early and accurate detection of implant complications. PURPOSE: To compare the quality of chemical shift encoding-based (CSE) water-fat-silicone separation compared to double inversion recovery (DIR) silicone-only imaging in breast magnetic resonance imaging (MRI). MATERIAL AND METHODS: This retrospective, single-center study included women with silicone implants subjected to 3-T MRI between January 2021 and March 2022. MRI included (i) two-dimensional silicone-only T2-weighted turbo spin echo DIR acquisition and (ii) three-dimensional CSE imaging based on multi-echo gradient-echo sequence enabling water-, fat-, and silicone-image separation. Images were evaluated and compared by three independent radiologists using a clinically established rating including differentiability of the silicone implant, visibility and contouring of the adjacent fibrous capsule, and accuracy of intralesional folds in a ranking of 1-5. The apparent contrast-to-noise (aCNR) was calculated. RESULTS: In 71 women, the average quality of water-fat-silicone images from CSE imaging was assessed as "good" (assessment 4 ± 0.9). In 68 (96%) patients, CSE imaging achieved a concise delineation of the silicone implant and precise visualization of the fibrous capsule that was not distinguishable in DIR imaging. Implant ruptures were more easily detected in CSE imaging. The aCNR was higher in CSE compared to DIR imaging (18.43 ± 9.8 vs. 14.73 ± 2.5; P = 0.002). CONCLUSION: Intrinsically co-registered water-fat-silicone-separated CSE-based images enable a reliable assessment of silicone implants. The simultaneously improved differentiability of the implant and fibrous capsule may provide clinicians with a valuable tool for an accurate evaluation of implant integrity and early detection of potential complications.


Assuntos
Implantes de Mama , Imageamento por Ressonância Magnética , Silicones , Humanos , Feminino , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Adulto , Pessoa de Meia-Idade , Mama/diagnóstico por imagem , Água , Tecido Adiposo/diagnóstico por imagem , Géis de Silicone , Idoso
11.
Skeletal Radiol ; 53(7): 1319-1332, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38240761

RESUMO

OBJECTIVE: To qualitatively and quantitatively evaluate the 2.5-year MRI outcome after Matrix-associated autologous chondrocyte implantation (MACI) at the patella, reconstruction of the medial patellofemoral ligament (MPFL), and combined procedures. METHODS: In 66 consecutive patients (age 22.8 ± 6.4years) with MACI at the patella (n = 16), MPFL reconstruction (MPFL; n = 31), or combined procedures (n = 19) 3T MRI was performed 2.5 years after surgery. For morphological MRI evaluation WORMS and MOCART scores were obtained. In addition quantitative cartilage T2 and T1rho relaxation times were acquired. Several clinical scores were obtained. Statistical analyses included descriptive statistics, Mann-Whitney-U-tests and Pearson correlations. RESULTS: WORMS scores at follow-up (FU) were significantly worse after combined procedures (8.7 ± 4.9) than after isolated MACI (4.3 ± 3.6, P = 0.005) and after isolated MPFL reconstruction (5.3 ± 5.7, P = 0.004). Bone marrow edema at the patella in the combined group was the only (non-significantly) worsening WORMS parameter from pre- to postoperatively. MOCART scores were significantly worse in the combined group than in the isolated MACI group (57 ± 3 vs 88 ± 9, P < 0.001). Perfect defect filling was achieved in 26% and 69% of cases in the combined and MACI group, respectively (P = 0.031). Global and patellar T2 values were higher in the combined group (Global T2: 34.0 ± 2.8ms) and MACI group (35.5 ± 3.1ms) as compared to the MPFL group (31.1 ± 3.2ms, P < 0.05). T2 values correlated significantly with clinical scores (P < 0.005). Clinical Cincinnati scores were significantly worse in the combined group (P < 0.05). CONCLUSION: After combined surgery with patellar MACI and MPFL reconstruction inferior MRI outcomes were observed than after isolated procedures. Therefore, patients with need for combined surgery may be at particular risk for osteoarthritis.


Assuntos
Imageamento por Ressonância Magnética , Patela , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Feminino , Resultado do Tratamento , Patela/diagnóstico por imagem , Patela/cirurgia , Adulto , Condrócitos/transplante , Transplante Autólogo , Adulto Jovem , Articulação Patelofemoral/diagnóstico por imagem , Articulação Patelofemoral/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Ligamentos Articulares/diagnóstico por imagem , Ligamentos Articulares/cirurgia , Adolescente
12.
Radiol Artif Intell ; 6(4): e230471, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38809148

RESUMO

Sex-specific abdominal organ volume and proton density fat fraction (PDFF) in people with obesity during a weight loss intervention was assessed with automated multiorgan segmentation of quantitative water-fat MRI. An nnU-Net architecture was employed for automatic segmentation of abdominal organs, including visceral and subcutaneous adipose tissue, liver, and psoas and erector spinae muscle, based on quantitative chemical shift-encoded MRI and using ground truth labels generated from participants of the Lifestyle Intervention (LION) study. Each organ's volume and fat content were examined in 127 participants (73 female and 54 male participants; body mass index, 30-39.9 kg/m2) and in 81 (54 female and 32 male participants) of these participants after an 8-week formula-based low-calorie diet. Dice scores ranging from 0.91 to 0.97 were achieved for the automatic segmentation. PDFF was found to be lower in visceral adipose tissue compared with subcutaneous adipose tissue in both male and female participants. Before intervention, female participants exhibited higher PDFF in subcutaneous adipose tissue (90.6% vs 89.7%; P < .001) and lower PDFF in liver (8.6% vs 13.3%; P < .001) and visceral adipose tissue (76.4% vs 81.3%; P < .001) compared with male participants. This relation persisted after intervention. As a response to caloric restriction, male participants lost significantly more visceral adipose tissue volume (1.76 L vs 0.91 L; P < .001) and showed a higher decrease in subcutaneous adipose tissue PDFF (2.7% vs 1.5%; P < .001) than female participants. Automated body composition analysis on quantitative water-fat MRI data provides new insights for understanding sex-specific metabolic response to caloric restriction and weight loss in people with obesity. Keywords: Obesity, Chemical Shift-encoded MRI, Abdominal Fat Volume, Proton Density Fat Fraction, nnU-Net ClinicalTrials.gov registration no. NCT04023942 Supplemental material is available for this article. Published under a CC BY 4.0 license.


Assuntos
Gordura Abdominal , Imageamento por Ressonância Magnética , Humanos , Masculino , Feminino , Imageamento por Ressonância Magnética/métodos , Gordura Abdominal/diagnóstico por imagem , Pessoa de Meia-Idade , Adulto , Fatores Sexuais , Obesidade/diagnóstico por imagem , Obesidade/dietoterapia , Prótons , Restrição Calórica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA