Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Radiology ; 302(2): 357-366, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34726535

RESUMO

Background The Bosniak classification system for cystic renal masses was updated in 2019 in part to improve agreement compared with the 2005 version. Purpose To compare and investigate interrater agreement of Bosniak version 2019 and Bosniak version 2005 at CT and MRI. Materials and Methods In this retrospective single-center study, a blinded eight-reader assessment was performed in which 195 renal masses prospectively considered Bosniak IIF-IV (95 at CT, 100 at MRI, from 2006 to 2019 with version 2005) were re-evaluated with Bosniak versions 2019 and 2005. Radiologists (four faculty members, four residents) who were blinded to the initial clinical reading and histopathologic findings assessed all feature components and reported the overall Bosniak class for each system independently. Agreement was assessed with Gwet agreement coefficients. Uni- and multivariable linear regression models were developed to identify predictors of dispersion in the final Bosniak class assignment that could inform system refinement. Results A total of 185 patients were included (mean age, 63 years ± 13 [standard deviation]; 118 men). Overall interrater agreement was similar between Bosniak version 2019 and version 2005 (Gwet agreement coefficient: 0.51 [95% CI: 0.45, 0.57] vs 0.46 [95% CI: 0.42, 0.51]). This was true for experts (0.54 vs 0.49) and novices (0.50 vs 0.47) and at CT (0.56 vs 0.51) and MRI (0.52 vs 0.43). Nine percent of masses prospectively considered cystic using Bosniak version 2005 criteria were considered solid using version 2019 criteria. In general, masses were more commonly classified in lower categories when radiologists used Bosniak version 2019 criteria compared with version 2005 criteria. The sole predictor of dispersion in Bosniak version 2019 class assignment was dispersion in septa or wall quality (ie, smooth vs irregular thickening vs nodule; 72% [MRI] and 60% [CT] overall model variance explained; multivariable P < .001). Conclusion Overall interrater agreement was similar between Bosniak version 2019 and version 2005; disagreements in septa or wall quality were common and strongly predictive of variation in Bosniak class assignment. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Eberhardt in this issue.


Assuntos
Doenças Renais Císticas/classificação , Doenças Renais Císticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
2.
J Natl Compr Canc Netw ; 17(12): 1505-1511, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31805530

RESUMO

BACKGROUND: Objective radiographic assessment is crucial for accurately evaluating therapeutic efficacy and patient outcomes in oncology clinical trials. Imaging assessment workflow can be complex; can vary with institution; may burden medical oncologists, who are often inadequately trained in radiology and response criteria; and can lead to high interobserver variability and investigator bias. This article reviews the development of a tumor response assessment core (TRAC) at a comprehensive cancer center with the goal of providing standardized, objective, unbiased tumor imaging assessments, and highlights the web-based platform and overall workflow. In addition, quantitative response assessments by the medical oncologists, radiologist, and TRAC are compared in a retrospective cohort of patients to determine concordance. PATIENTS AND METHODS: The TRAC workflow includes an image analyst who pre-reviews scans before review with a board-certified radiologist and then manually uploads annotated data on the proprietary TRAC web portal. Patients previously enrolled in 10 lung cancer clinical trials between January 2005 and December 2015 were identified, and the prospectively collected quantitative response assessments by the medical oncologists were compared with retrospective analysis of the same dataset by a radiologist and TRAC. RESULTS: This study enlisted 49 consecutive patients (53% female) with a median age of 60 years (range, 29-78 years); 2 patients did not meet study criteria and were excluded. A linearly weighted kappa test for concordance for TRAC versus radiologist was substantial at 0.65 (95% CI, 0.46-0.85; standard error [SE], 0.10). The kappa value was moderate at 0.42 (95% CI, 0.20-0.64; SE, 0.11) for TRAC versus oncologists and only fair at 0.34 (95% CI, 0.12-0.55; SE, 0.11) for oncologists versus radiologist. CONCLUSIONS: Medical oncologists burdened with the task of tumor measurements in patients on clinical trials may introduce significant variability and investigator bias, with the potential to affect therapeutic response and clinical trial outcomes. Institutional imaging cores may help bridge the gap by providing unbiased and reproducible measurements and enable a leaner workflow.


Assuntos
Ensaios Clínicos como Assunto/normas , Interpretação de Imagem Assistida por Computador/métodos , Imagem Multimodal/métodos , Neoplasias/patologia , Variações Dependentes do Observador , Oncologistas/estatística & dados numéricos , Critérios de Avaliação de Resposta em Tumores Sólidos , Adulto , Idoso , Terapia Combinada , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/diagnóstico por imagem , Neoplasias/terapia , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos
3.
Radiology ; 288(1): 158-163, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29664338

RESUMO

Purpose To assess the impact of clinical history on the maximum Prostate Imaging Recording and Data System (PI-RADS) version 2 (v2) score assigned to multiparametric magnetic resonance (MR) imaging of the prostate. Materials and Methods This retrospective cohort study included 120 consecutively selected multiparametric prostate MR imaging studies performed between November 1, 2016, and December 31, 2016. Sham clinical data in four domains (digital rectal examination, prostate-specific antigen level, plan for biopsy, prior prostate cancer history) were randomly assigned to each case by using a balanced orthogonal design. Six fellowship-trained abdominal radiologists independently reviewed the sham data, actual patient age, and each examination while they were blinded to interreader scoring, true clinical data, and histologic findings. Readers were told the constant sham histories were true, believed the study to be primarily investigating interrater agreement, and were asked to assign a maximum PI-RADS v2 score to each case. Linear regression was performed to assess the association between clinical variables and maximum PI-RADS v2 score designation. Intraclass correlation coefficients (ICCs) were obtained to compare interreader scoring. Results Clinical information had no significant effect on maximum PI-RADS v2 scoring for any of the six readers (P = .09-.99, 42 reader-variable pairs). Distributions of maximum PI-RADS v2 scores in the research context were similar to the distribution of the scores assigned clinically and had fair-to-excellent pairwise interrater agreement (ICC range: 0.53-0.76). Overall interrater agreement was good (ICC: 0.64; 95% confidence interval: 0.57, 0.71). Conclusion Clinical history does not appear to be a substantial bias in maximum PI-RADS v2 score assignment. This is potentially important for clinical nomograms that plan to incorporate PI-RADS v2 score and clinical data into their algorithms (ie, PI-RADS v2 scoring is not confounded by clinical data).


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Sistemas de Informação em Radiologia/estatística & dados numéricos , Idoso , Biópsia , Estudos de Coortes , Exame Retal Digital/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Próstata/patologia , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Estudos Retrospectivos
4.
AJR Am J Roentgenol ; 211(4): 760-766, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30063381

RESUMO

OBJECTIVE: Topical tissue sealants and hemostatic agents, seen on postoperative imaging in a variety of intraabdominal and pelvic locations, have the potential to be mistaken for abdominal abnormalities, especially if the radiologist is not aware of the patient's surgical history. The normal appearance of these agents may mimic abscesses, tumors, enlarged lymph nodes, or retained foreign bodies. Therefore, it is important to be familiar with their typical imaging appearances and to review the surgical records when needed to avoid misdiagnoses. The purpose of this article is to increase the radiologist's familiarity with various types of topical tissue sealants and hemostatic agents used during surgical and percutaneous procedures in the abdomen and pelvis along with their radiologic appearances. CONCLUSION: Various types of hemostatic agents are now commonly used during surgery and percutaneous procedures in the abdomen and pelvis, and it is important to recognize the various appearances of these agents. Although there are suggestive features outlined in this article, the most important factor for the radiologist is to be aware of the patient's history and the possibility that a hemostatic agent may be present. On postoperative imaging, hemostatic agents may mimic abscesses, tumors, enlarged lymph nodes, or retained foreign bodies, and accurate diagnosis can save a patient unnecessary treatment. It is therefore crucial to incorporate knowledge of the patient's surgical history with recognition of the typical imaging appearances of hemostatic agents and other pseudolesions to avoid misdiagnoses.


Assuntos
Adesivo Tecidual de Fibrina , Corpos Estranhos/diagnóstico por imagem , Hemostáticos , Radiografia Abdominal , Diagnóstico Diferencial , Humanos , Período Pós-Operatório
5.
AJR Am J Roentgenol ; 208(6): 1185-1192, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28301210

RESUMO

OBJECTIVE: Dual-energy CT (DECT) is being increasingly used for abdominal imaging because it provides incremental benefit of material characterization without significant increase in radiation dose. This article provides an overview of current DECT techniques and use of DECT in urinary tract imaging for assessment of renal masses and urinary calculi characterization and in CT urography. CONCLUSION: Incorporation of DECT into clinical practice and use of its material characterization capabilities in urinary tract imaging enable characterization of urinary calculi and incidental renal lesions and can reduce radiation dose by allowing generation of virtual unenhanced images.


Assuntos
Neoplasias Renais/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Cálculos Urinários/diagnóstico por imagem , Urografia/métodos , Medicina Baseada em Evidências , Humanos , Radiografia Abdominal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
J Comput Assist Tomogr ; 41(1): 8-14, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27824670

RESUMO

This is the fourth of a series of 4 white papers that represent expert consensus documents developed by the Society of Computed Body Tomography and Magnetic Resonance through its task force on dual-energy computed tomography. This article, part 4, discusses DECT for abdominal and pelvic applications and, at the end of each, will offer our consensus opinions on the current clinical utility of the application and opportunities for further research.


Assuntos
Doenças do Sistema Digestório/diagnóstico por imagem , Doenças Urogenitais Femininas/diagnóstico por imagem , Doenças Urogenitais Masculinas/diagnóstico por imagem , Guias de Prática Clínica como Assunto/normas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/normas , Tomografia Computadorizada por Raios X/métodos , Medicina Baseada em Evidências , Feminino , Humanos , Internacionalidade , Masculino , Pelve/diagnóstico por imagem , Radiografia Abdominal/métodos
7.
J Comput Assist Tomogr ; 41(1): 1-7, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28081050

RESUMO

This is the third of a series of 4 white papers that represent Expert Consensus Documents developed by the Society of Computed Body Tomography and Magnetic Resonance through its Task Force on dual-energy computed tomography. This paper, part 3, describes computed tomography angiography and thoracic, cardiac, vascular, and musculoskeletal clinical applications. At the end of the discussion of each application category (vascular, cardiac, pulmonary, and musculoskeletal), we present our consensus opinions on the current clinical utility of the application and opportunities for further research.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Doenças Musculoesqueléticas/diagnóstico por imagem , Guias de Prática Clínica como Assunto , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/normas , Tomografia Computadorizada por Raios X/normas , Medicina Baseada em Evidências , Humanos , Estados Unidos
8.
J Comput Assist Tomogr ; 40(6): 846-850, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27768619
9.
J Comput Assist Tomogr ; 40(6): 841-845, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27841774

RESUMO

This is the first of a series of 4 white papers that represent Expert Consensus Documents developed by the Society of Computed Body Tomography and Magnetic Resonance through its task force on dual-energy computed tomography (DECT). This article, part 1, describes the fundamentals of the physical basis for DECT and the technology of DECT and proposes uniform nomenclature to account for differences in proprietary terms among manufacturers.


Assuntos
Guias de Prática Clínica como Assunto , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/normas , Terminologia como Assunto , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas , Biotecnologia/instrumentação , Biotecnologia/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Estados Unidos
10.
AJR Am J Roentgenol ; 205(3): W294-304, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26295665

RESUMO

OBJECTIVE: Congenital anomalies of the kidneys and urinary tract (CAKUT) encompass a spectrum of anomalies that result from genetic, epigenetic, environmental, and molecular signal aberrations at key stages of urinary tract development. CAKUT can be seen incidentally on cross-sectional imaging of the abdomen or can be a cause for adult-onset chronic kidney disease, posing new challenges for nephrologists, urologists, and radiologists. CONCLUSION: Awareness of CAKUT and familiarity with their imaging findings permit optimal patient management and thorough workup to prevent hypertension and progression from CAKUT to renal failure. The purpose of this article is to review the cross-sectional imaging findings of CAKUT that may present in adulthood.


Assuntos
Rim/anormalidades , Imageamento por Ressonância Magnética , Insuficiência Renal/diagnóstico , Tomografia Computadorizada por Raios X , Sistema Urinário/anormalidades , Urografia , Adulto , Fatores Etários , Feminino , Humanos , Masculino , Insuficiência Renal/etiologia , Insuficiência Renal/prevenção & controle
11.
Abdom Imaging ; 40(3): 626-42, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25189130

RESUMO

The largest and most complex serosal membrane in the body, the peritoneum, lines the abdominal cavity, and the abdominopelvic viscera. It is frequently involved in a variety of benign and malignant processes. While secondary involvement of the peritoneum is more common, primary tumors can be a diagnostic challenge. Knowledge of the anatomy is crucial in understanding the various pathologic processes. Cross-sectional imaging plays an important role in diagnosing and evaluating the extent of the disease processes. This article reviews the imaging anatomy of the peritoneum and mesentery and the common pathologies involving it.


Assuntos
Mesentério , Doenças Peritoneais/diagnóstico , Humanos , Infarto/diagnóstico , Omento/irrigação sanguínea , Paniculite Peritoneal , Peritônio/anatomia & histologia , Peritônio/irrigação sanguínea , Peritonite/diagnóstico , Pseudomixoma Peritoneal/diagnóstico
12.
Abdom Imaging ; 40(7): 2248-62, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26070748

RESUMO

Small bowel obstruction (SBO) accounts for a considerable proportion of emergency room visits, inpatient admissions, and surgical interventions in the United States. Multi-detector computed tomography (MDCT) plays a key role in imaging patients presenting with acute symptoms suggestive of SBO, which helps in establishing the diagnosis, elucidating the cause of obstruction, and detecting complications, such as ischemia or frank bowel necrosis and perforation. Recently, management of patients with SBO has shifted toward a more conservative approach with supportive care and nasogastric tube decompression, as the obstruction in many cases can resolve spontaneously without the need for operative intervention. However, management decisions in SBO remain notoriously difficult, relying on a combination of clinical, laboratory, and imaging factors to help stratify patients into conservative or surgical treatment. Imaging is often an important factor assisting in the decision-making process since traditional clinical signs of vascular compromise, such as acidosis, fever, leukocytosis, and tachycardia are often unreliable in predicting the need for operative intervention. Thus, it is critically important for radiologists to identify imaging features that suggest or indicated high likelihood of bowel vascular compromise in order to help optimize management prior to the development of bowel ischemia and eventually necrosis. By excluding signs of potentially ischemic or necrotic bowel on MDCT, patients may be spared unnecessary surgery, thus decreasing postsurgical complications and averting potential increase for the risk of future SBO and repeated surgery. Conversely, if imaging features indicate potential vascular compromise of the bowel wall that may lead to bowel ischemia, urgent surgical intervention may prevent progression to bowel necrosis and subsequent perforation.


Assuntos
Obstrução Intestinal/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Humanos , Enteropatias/complicações , Enteropatias/diagnóstico por imagem , Obstrução Intestinal/complicações , Perfuração Intestinal/complicações , Perfuração Intestinal/diagnóstico por imagem , Isquemia/complicações , Isquemia/diagnóstico por imagem , Necrose/complicações , Necrose/diagnóstico por imagem
13.
Radiology ; 272(1): 123-31, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24617733

RESUMO

PURPOSE: To compare frequency and severity of arterial phase respiratory motion-related artifact following gadoxetate disodium and gadobenate dimeglumine in matched patients administered both contrast media at different times. MATERIALS AND METHODS: Institutional review board approval was obtained, with patient consent waived, for this retrospective, HIPAA-compliant study. Ninety patients underwent gadobenate dimeglumine-enhanced abdominal magnetic resonance (MR) followed by gadoxetate disodium-enhanced abdominal MR and were matched to 90 patients who were administered the same contrast media in reverse order (180 patients). Matching was based on length of time between paired examinations. Gadobenate dimeglumine dose was weight based (0.1 mmol per kilogram body weight). Gadoxetate disodium dose was typically fixed (10 or 20 mL [off label]). Three readers blinded to contrast agent assigned a respiratory motion-related artifact score (1 [none] to 5 [nondiagnostic]) for nonenhanced, arterial, venous, and late dynamic phases. Frequency of greater new arterial phase respiratory motion-related artifact in each within-patient pair and aggregate rate of new severe transient arterial phase respiratory motion-related artifact (scores ≤ 2, nonenhanced and venous and/or late dynamic phases; ≥ 4, arterial phase) were compared (McNemar test). RESULTS: For groups 1 and 2, respectively, mean dose (gadoxetate disodium, 16.6 mL vs 16.6 mL, P = .99; gadobenate dimeglumine, 18.0 mL vs 17.8 mL, P = .77) and mean time between examinations (191 days vs 191 days, P = .99) were not significantly different between matched populations. Gadoxetate disodium was associated with significantly higher incidence of new arterial phase respiratory motion-related artifact compared with gadobenate dimeglumine (39% vs 10%, P < .0001) and of new severe transient arterial phase respiratory motion-related artifact (18% vs 2%, P < .0001) in patients administered both agents at different times. CONCLUSION: Fixed off-label dose (10 or 20 mL) of gadoxetate disodium is associated with arterial phase respiratory motion-related artifact that is sometimes severe and occurs significantly more often than after gadobenate dimeglumine in patients who received both contrast media.


Assuntos
Artefatos , Meios de Contraste , Gadolínio DTPA , Hepatopatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Respiração , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Movimento , Estudos Retrospectivos , Fatores de Risco
14.
Radiology ; 272(1): 132-42, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24555636

RESUMO

PURPOSE: To determine for expert and novice radiologists repeatability of major diagnostic features and scoring systems (ie, Liver Imaging Reporting and Data System [LI-RADS], Organ Procurement and Transplantation Network [OPTN], and American Association for the Study of Liver Diseases [AASLD]) for hepatocellular carcinoma (HCC) by using magnetic resonance (MR) imaging. MATERIALS AND METHODS: Institutional review board approval was obtained and patient consent was waived for this HIPAA-compliant, retrospective study. The LI-RADS discussed in this article refers to version 2013.1. Ten blinded readers reviewed 100 liver MR imaging studies that demonstrated observations preliminarily assigned LI-RADS scores of LR1-LR5. Diameter and major HCC features (arterial hyperenhancement, washout appearance, pseudocapsule) were recorded for each observation. LI-RADS, OPTN, and AASLD scores were assigned. Interreader agreement was assessed by using intraclass correlation coefficients and κ statistics. Scoring rates were compared by using McNemar test. RESULTS: Overall interreader agreement was substantial for arterial hyperenhancement (0.67 [95% confidence interval {CI}: 0.65, 0.69]), moderate for washout appearance (0.48 [95%CI: 0.46, 0.50]), moderate for pseudocapsule (0.52 [95% CI: 050, 0.54]), fair for LI-RADS (0.35 [95% CI: 0.34, 0.37]), fair for AASLD (0.39 [95% CI: 0.37, 0.42]), and moderate for OPTN (0.53 [95% CI: 0.51, 0.56]). Agreement for measured diameter was almost perfect (range, 0.95-0.97). There was substantial agreement for most scores consistent with HCC. Experts agreed significantly more than did novices and were significantly more likely than were novices to assign a diagnosis of HCC (P < .001). CONCLUSION: Two of three major features for HCC (washout appearance and pseudocapsule) have only moderate interreader agreement. Experts and novices who assigned scores consistent with HCC had substantial but not perfect agreement. Expert agreement is substantial for OPTN, but moderate for LI-RADS and AASLD. Novices were less consistent and less likely to diagnose HCC than were experts.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Competência Clínica , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/patologia , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Neoplasias Hepáticas/patologia , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Compostos Organometálicos , Reprodutibilidade dos Testes , Estudos Retrospectivos
15.
AJR Am J Roentgenol ; 202(3): 648-55, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24555604

RESUMO

OBJECTIVE: The objective of our study was to evaluate image quality and overall adequacy of low-dose CT angiography (CTA) with model-based iterative reconstruction (MBIR) in patients who had undergone endovascular aneurysm repair (EVAR) of a thoracic or abdominal aortic aneurysm. MATERIALS AND METHODS: Thirty patients, all of whom had undergone standard-dose CTA performed previously with adaptive statistical iterative reconstruction (ASIR), underwent low-dose CTA for surveillance after EVAR. Two radiologists randomly evaluated both studies, and quality parameters were assessed. The maximal aneurysm diameter was measured, and the images were evaluated to see whether an endoleak was present. The image noise and contrast-to-noise ratio (CNR) were measured. The volume CT dose index and dose-length product were recorded. RESULTS: The mean image score for low-dose CTA was acceptable to very good in all categories of assessment. There was no significant difference between low-dose CTA and standard-dose CTA in the evaluation of the stent lumen. Subjective assessments of stent configuration, aneurysm outline, aortic branch vessel outline, overall adequacy of vascular imaging, and overall adequacy of solid organ imaging were superior on standard-dose CTA. Interobserver agreement for endoleak detection was higher for low-dose CTA. There was no significant difference in the mean aneurysm diameter between the two readers on low-dose CTA and standard-dose CTA. The effective radiation dose for low-dose CTA was lower than standard-dose CTA during both the arterial (mean, 4.4 vs 16.2 mSv, respectively) and the delayed (2.4 vs 6.7 mSv) phase acquisitions. The measured image noise was lower (14.7 vs 19.3 HU) and CNR was higher (25.6 vs 17.1) on the low-dose CTA studies than on the standard-dose CTA studies. CONCLUSION: Low-dose CTA with MBIR enables up to 73% dose reduction as compared with CTA performed with ASIR while maintaining diagnostic adequacy for CTA surveillance of patients who have undergone EVAR of a thoracic or abdominal aortic aneurysm.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Modelos Cardiovasculares , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Aneurisma Aórtico/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
16.
AJR Am J Roentgenol ; 203(2): 329-35, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25055267

RESUMO

OBJECTIVE: The purpose of this article is to evaluate single-source dual-energy CT (DECT) for distinguishing benign and indeterminate adrenal nodules, with attention to the effects of phase of IV contrast enhancement. MATERIALS AND METHODS: A retrospective review revealed 273 contrast-enhanced abdominal DECT examinations from November 2009 through March 2012. Fifty adrenal nodules 0.8 cm or larger were identified in 41 patients (22 women and 19 men; average age, 66 years; age range, 36-88 years). CT postprocessing and measurements were independently performed by two radiologists (readers 1 and 2) for each nodule, as follows: attenuation (in Hounsfield units) on true unenhanced images; contrast-enhanced attenuation (in Hounsfield units) on monochromatic spectral images at 40, 75, and 140 keV; and contrast-enhanced material density (in milligrams per milliliter) on virtual unenhanced images. Nodules were classified as benign (< 10 HU) and indeterminate (≥ 10 HU) according to true unenhanced images. RESULTS: Interreader agreement regarding benign and indeterminate nodules was high (κ = 0.92; 95% CI, 0.8-1.0). At 140 keV, the attenuation of benign nodules was significantly lower (reader 1, 7.0 ± 12.5 HU; reader 2, 7.8 ± 9.2 HU) than that of indeterminate nodules (reader 1, 15.7 ± 20.5 HU [p = 0.004]; reader 2, 17.5 ± 13.4 HU [p < 0.0001]). On virtual unenhanced images, benign nodules had significantly lower material density (reader 1, 992.4 ± 9.9 mg/mL; reader 2, 992.7 ± 9.6 mg/mL) than did indeterminate nodules (reader 1, 1001.1 ± 20.5 mg/mL [p = 0.038]; reader 2, 1007.6 ± 13.4 mg/mL [p < 0.0001]). CONCLUSION: DECT tools can mathematically subtract iodine or minimize its effects in high-energy reconstructions, approximating unenhanced imaging and potentially reducing the need for additional studies to triage adrenal nodules detected on contrast-enhanced DECT examinations.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Técnica de Subtração , Triagem
17.
Radiographics ; 34(1): 4-17, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24428277

RESUMO

Recent advances in computed tomographic (CT) scanning technique such as automated tube current modulation (ATCM), optimized x-ray tube voltage, and better use of iterative image reconstruction have allowed maintenance of good CT image quality with reduced radiation dose. ATCM varies the tube current during scanning to account for differences in patient attenuation, ensuring a more homogeneous image quality, although selection of the appropriate image quality parameter is essential for achieving optimal dose reduction. Reducing the x-ray tube voltage is best suited for evaluating iodinated structures, since the effective energy of the x-ray beam will be closer to the k-edge of iodine, resulting in a higher attenuation for the iodine. The optimal kilovoltage for a CT study should be chosen on the basis of imaging task and patient habitus. The aim of iterative image reconstruction is to identify factors that contribute to noise on CT images with use of statistical models of noise (statistical iterative reconstruction) and selective removal of noise to improve image quality. The degree of noise suppression achieved with statistical iterative reconstruction can be customized to minimize the effect of altered image quality on CT images. Unlike with statistical iterative reconstruction, model-based iterative reconstruction algorithms model both the statistical noise and the physical acquisition process, allowing CT to be performed with further reduction in radiation dose without an increase in image noise or loss of spatial resolution. Understanding these recently developed scanning techniques is essential for optimization of imaging protocols designed to achieve the desired image quality with a reduced dose.


Assuntos
Doses de Radiação , Proteção Radiológica/métodos , Radiografia Abdominal/métodos , Radiografia Abdominal/tendências , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/tendências , Carga Corporal (Radioterapia) , Previsões , Humanos
18.
Abdom Imaging ; 39(4): 776-96, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24682526

RESUMO

Occasionally patients who undergo magnetic resonance imaging for presumed pelvic disease demonstrate unexpected musculoskeletal imaging findings in the imaged field. Such incidental findings can be challenging to the abdominal radiologist, who may not be familiar with their appearance or know the appropriate diagnostic considerations. Findings can include both normal and abnormal bone marrow, osseous abnormalities such as Paget's disease, avascular necrosis, osteomyelitis, stress and insufficiency fractures, and athletic pubalgia, benign neoplasms such as enchondroma and bone island, malignant processes such as metastasis and chondrosarcoma, soft tissue processes such as abscess, nerve-related tumors, and chordoma, joint- and bursal-related processes such as sacroiliitis, iliopsoas bursitis, greater trochanteric pain syndrome, and labral tears, and iatrogenic processes such as bone graft or bone biopsy. Though not all-encompassing, this essay will help abdominal radiologists to identify and describe this variety of pelvic musculoskeletal conditions, understand key radiologic findings, and synthesize a differential diagnosis when appropriate.


Assuntos
Achados Incidentais , Imageamento por Ressonância Magnética , Músculo Esquelético/patologia , Ossos Pélvicos/patologia , Pelve/patologia , Radiografia Abdominal , Diagnóstico Diferencial , Feminino , Humanos , Masculino
19.
Abdom Imaging ; 39(3): 570-87, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24525666

RESUMO

Splenic lesions are often incidentally detected on abdominal-computed tomography (CT), ultrasound, or magnetic resonance imaging (MRI), and these can pose a diagnostic challenge in patients with suspected or known malignancy. This review will discuss the multimodality imaging features of various benign and malignant splenic pathologies including trauma, infection, infarct, granulomatous disease, benign neoplasms such as hemangioma, hamartoma, and littoral cell angioma, cystic entities such as peliosis, splenic cysts, and pseudocysts, and malignant processes such as metastasis, lymphoma, angiosarcoma, and leiomyosarcoma. While several of these splenic pathologies have characteristic imaging features that are helpful in diagnosis, others have nonspecific findings. In such clinical dilemmas, image-guided intervention may be essential, and we therefore discuss the role of non-vascular, image-guided splenic interventions for diagnostic and therapeutic purposes. The radiologist can play a key part in the clinical diagnosis and management of splenic lesions, and therefore a thorough knowledge of the imaging features of splenic lesions and a thoughtful approach to their management is crucial.


Assuntos
Imagem Multimodal/métodos , Radiologia Intervencionista/métodos , Esplenopatias/diagnóstico , Humanos , Imageamento por Ressonância Magnética/métodos , Baço/diagnóstico por imagem , Baço/patologia , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos
20.
Abdom Imaging ; 39(3): 533-42, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24535480

RESUMO

PURPOSE: To determine whether the frequency of intra-observer measurement discrepancies ≥5 mm for solid renal masses varies by renal mass characteristics and CT contrast phase. MATERIALS AND METHODS: This HIPAA-compliant retrospective study was approved by our IRB. We selected single CT images performed during the nephrographic phase (NP) of renal enhancement in 97 patients, each with a single solid renal mass. Mass location, margin, heterogeneity, and growth pattern were assessed. Six readers measured each mass on two occasions >3 weeks apart. Readers also measured the masses on images in 50 patients who had corticomedullary phase (CMP) images obtained during the same study. Results were assessed using Chi-square/Fisher's exact and Wilcoxon Signed Rank tests, and logistic regression analyses. RESULTS: For NP to NP comparisons, intra-reader measurement differences ≥5 mm were seen for 3.7% (17/463) of masses <4 cm, but increased to 16.8% (20/119) for masses >4 cm (p < 0.0001). Masses with poorly defined margins (15.9% [22/138] vs. 3.4% [15/444] for well-defined margins, p < 0.0001) and heterogeneity (15.3% [22/144], vs. 5.0% [14/282] for minimally heterogeneous, vs. 0.6% [1/156] for homogeneous, p < 0.0001), were more frequently associated with measurement differences ≥5 mm. Differences ≥5 mm were more frequent when only CMP images were utilized (14% [42/299]), or when CMP images were compared with NP images (26% [77/299]). CONCLUSIONS: A ≥5 mm intra-reader variation in measured size of solid renal masses <4 cm is uncommon for NP to NP comparisons. Variation increases when masses are ≥4 cm, poorly defined, or heterogeneous; or when CMP images are utilized.


Assuntos
Meios de Contraste , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada Espiral/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Rim/diagnóstico por imagem , Rim/patologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Carga Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA