Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
PLoS One ; 13(6): e0198595, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29879161

RESUMO

BACKGROUND: Urinary Tract Infections (UTIs) are common bacterial infections, second only to respiratory tract infections and particularly prevalent within primary care. Conventional detection of UTIs is culture, however, return of results can take between 24 and 72 hours. The introduction of a point of care (POC) test would allow for more timely identification of UTIs, facilitating improved, targeted treatment. This study aimed to obtain consensus on the criteria required for a POC UTI test, to meet patient need within primary care. METHODS: Criteria for consideration were compiled by the research team. These criteria were validated through a two-round Delphi process, utilising an expert panel of healthcare professionals from across Europe and United States of America. Using web-based questionnaires, panellists recorded their level of agreement with each criterion based on a 5-point Likert Scale, with space for comments. Using median response, interquartile range and comments provided, criteria were accepted/rejected/revised depending on pre-agreed cut-off scores. RESULTS: The first round questionnaire presented thirty-three criteria to the panel, of which 22 were accepted. Consensus was not achieved for the remaining 11 criteria. Following response review, one criterion was removed, while after revision, the remaining 10 criteria entered the second round. Of these, four were subsequently accepted, resulting in 26 criteria considered appropriate for a POC test to detect urinary infections. CONCLUSION: This study generated an approved set of criteria for a POC test to detect urinary infections. Criteria acceptance and comments provided by the healthcare professionals also supports the development of a multiplex point of care UTI test.


Assuntos
Consenso , Técnica Delphi , Pessoal de Saúde , Sistemas Automatizados de Assistência Junto ao Leito/normas , Infecções Urinárias/diagnóstico , Humanos , Inquéritos e Questionários , Fatores de Tempo , Infecções Urinárias/urina
2.
J Microbiol Methods ; 71(3): 305-11, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17963904

RESUMO

A new generation of water soluble tetrazolium salts have recently become available and in this study we compared a colorimetric assay developed using one of these salts, 2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2, 4-disulfophenyl)-2H-tetrazolium, monosodium salt (WST-8), with a previously developed 2,3-bis [2-methyloxy-4-nitro-5-sulfophenyl]-2H-tetrazolium-5-carboxanilide (XTT) colorimetric assay to determine which agent is most suitable for use as a colorimetric indicator in susceptibility testing. The MICs of 6 antibiotics were determined for 33 staphylococci using both colorimetric assays and compared with those obtained using the British Society for Antimicrobial Chemotherapy reference broth microdilution method. Absolute categorical agreement between the reference and test methods ranged from 79% (cefuroxime) to 100% (vancomycin) for both assays. No minor or major errors occurred using either assay with very major errors ranging from zero (vancomycin) to seven (cefuroxime). Analysis of the distribution of differences in the log(2) dilution MIC results revealed overall agreement, within the accuracy limits of the standard test (+/-1 log(2) dilution), using the XTT and WST-8 assays of 98% and 88%, respectively. Further studies on 31 ESBL-producing isolates were performed using the XTT method with absolute categorical agreement ranging from 87% (nitrofurantoin) to 100% (ofloxacin and meropenem). No errors were noted for either ofloxacin or meropenem with overall agreement of 91%. The data suggests that XTT is more reliable and accurate than WST-8 for use in a rapid antimicrobial susceptibility test.


Assuntos
Antibacterianos/farmacologia , Colorimetria/métodos , Testes de Sensibilidade Microbiana/métodos , Staphylococcus/efeitos dos fármacos , beta-Lactamases/metabolismo , Anti-Infecciosos/farmacologia , Testes de Sensibilidade Microbiana/normas , Staphylococcus/crescimento & desenvolvimento , Staphylococcus/isolamento & purificação , Sais de Tetrazólio
3.
J Med Microbiol ; 55(Pt 10): 1375-1380, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17005786

RESUMO

The susceptibility of Staphylococcus aureus [meticillin-resistant (MRSA) and meticillin-sensitive (MSSA)] and coagulase-negative staphylococci (CoNS), which respectively form part of the transient and commensal skin flora, to tea-tree oil (TTO) was compared using broth microdilution and quantitative in vitro time-kill test methods. MRSA and MSSA isolates were significantly less susceptible than CoNS isolates, as measured by both MIC and minimum bactericidal concentration. A significant decrease in the mean viable count of all isolates in comparison with the control was seen at each time interval in time-kill assays. However, the only significant difference in the overall mean log10 reduction in viable count between the groups of isolates was between CoNS and MSSA at 3 h, with CoNS isolates demonstrating a significantly lower mean reduction. To provide a better simulation of in vivo conditions on the skin, where bacteria are reported to grow as microcolonies encased in glycocalyx, the bactericidal activity of TTO against isolates grown as biofilms was also compared. Biofilms formed by MSSA and MRSA isolates were completely eradicated following exposure to 5 % TTO for 1 h. In contrast, of the biofilms formed by the nine CoNS isolates tested, only five were completely killed, although a reduction in viable count was apparent for the other four isolates. These results suggest that TTO exerts a greater bactericidal activity against biofilm-grown MRSA and MSSA isolates than against some biofilm-grown CoNS isolates.


Assuntos
Anti-Infecciosos Locais/farmacologia , Biofilmes/efeitos dos fármacos , Meticilina/farmacologia , Plâncton/efeitos dos fármacos , Infecções Cutâneas Estafilocócicas/microbiologia , Staphylococcus/efeitos dos fármacos , Óleo de Melaleuca/farmacologia , Biofilmes/crescimento & desenvolvimento , Coagulase , Humanos , Resistência a Meticilina , Testes de Sensibilidade Microbiana , Staphylococcus/enzimologia , Staphylococcus/fisiologia , Staphylococcus aureus/efeitos dos fármacos
4.
BJU Int ; 96(3): 360-4, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16042730

RESUMO

OBJECTIVE: To evaluate a novel urine-collection device (UCD) that automatically collects a midstream urine (MSU) sample, and compare contamination rates to those of the conventional MSU sampling method, as the contamination of urine samples for microbiological analysis in women leads to diagnostic ambiguity and unnecessary costs, and may result in part from an incorrect collection procedure. PATIENTS AND METHODS: In all, 2823 women from four centres, most from antenatal clinics, were randomized to two urine-collection methods: conventional MSU collection and collection with a novel MSU UCD (the Whiz, JBOL Ltd, Oxford, UK). Semi-quantitative growth and user acceptability were compared between the collection methods. RESULTS: MSU samples collected with the UCD had significantly fewer mixed growth samples (9% vs 14%, P = 0.001; 36% relative reduction), significantly fewer heavy mixed growth samples (1.2% vs 3.0%, P = 0.004; 60% relative reduction) and required significantly fewer re-tests (11% vs 16%, P = 0.002; 31% relative reduction). There were more samples with clinically insignificant growth than the conventional MSU group (86% vs 82%, P = 0.005). Those using the UCD preferred it to the conventional method (67.5%) and experienced significantly less spillage during sample collection (27% vs 46%, P = 0.001; relative reduction 41%). CONCLUSION: The UCD reduced contamination rates in urine samples and improved the predictive value of the urine culture in a manner acceptable to patients and staff.


Assuntos
Contaminação de Equipamentos/prevenção & controle , Manejo de Espécimes/instrumentação , Urinálise/instrumentação , Urina , Adulto , Análise de Variância , Desenho de Equipamento , Feminino , Humanos , Pessoa de Meia-Idade , Satisfação do Paciente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA