Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39162770

RESUMO

PURPOSE: In patients with end-stage heart failure who undergo left ventricular assist device (LVAD) implantation, higher pulmonary vascular resistance (PVR) is associated with higher right heart failure rates and ineligibility for heart transplant. Concomitant mitral regurgitation (MR) could potentially worsen pulmonary hemodynamics and lead to worse outcomes; however, its effects in this patient population have not been specifically examined. METHODS: Using an institutional database spanning November 2003 to August 2017, we retrospectively identified patients with elevated PVR who underwent LVAD implantation. Patients were stratified by concurrent MR: moderate/severe (PVR + MR) vs. mild/none (PVR - MR). Cumulative incidence functions and Fine-Gray competing risk regression were performed to assess the effect of MR on heart transplant rates and overall survival during index LVAD support. RESULTS: Of 644 LVAD recipients, 232 (171 HeartMate II, 59 HeartWare, 2 HeartMate III) had baseline PVR > 3 Woods units; of these, 124 (53%) were INTERMACS 1-2, and 133 (57%) had moderate/severe MR (≥ 3 +). Patients with PVR + MR had larger a baseline left ventricular end-diastolic diameter than patients with PVR - MR (87.9 ± 38.2 mm vs. 75.9 ± 38.0 mm; P = 0.02). Median clinical follow-up was 18.8 months (interquartile range: 4.7-36.4 months). Moderate/severe MR was associated with lower mortality rates during index LVAD support (adjusted hazard ratio 0.64, 95% CI 0.41-0.98; P = 0.045) and higher heart transplant rates (adjusted odds ratio 2.86, 95% CI 1.31-6.25; P = 0.009). No differences in stroke, gastrointestinal bleeding, or right heart failure rates were observed. CONCLUSIONS: Among LVAD recipients with elevated preoperative PVR, those with moderate/severe MR had better overall survival and higher transplant rates than those with mild/no MR. These hypothesis-generating findings could be explained by incremental LVAD benefits resulting from reduction of MR and better LV unloading in a subset of patients with larger ventricles at baseline. In patients with preoperative elevated PVR, MR severity may be a prognostic sign that can inform patient selection for end-stage heart failure therapy.

2.
Catheter Cardiovasc Interv ; 96(2): 481-487, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31957915

RESUMO

OBJECTIVES: To examine the safety of utilizing transapical access during structural interventions. BACKGROUND: Complex interventions of the mitral or aortic region sometimes require coaxial forces to orient and deliver devices. Apical access can provide coaxial countertraction for either transseptal or retrograde aortic access. This manuscript describes the single center experience of small bore transapical access. METHODS: Retrospective review of cases from 2013 to 2018 at Henry Ford Hospital was performed. Patient demographics and procedure characteristics were abstracted to describe the safety of transapical access using small bore sheaths. RESULTS: A total 21 cases were performed at Henry Ford, most of them for transcatheter mitral valve replacement (81%). The mean sheath size used was 4.7 ± 0.9 Fr and protamine was used at the end of 57% of cases. All patients received nitinol-based plugs, 80.1% were from the Amplatz Duct Occluder II type. Four major complications related apical puncture occurred, two pericardial effusions, two hemothorax. Over a median follow time of 430 days (IQR 50-652) a total of five deaths occurred, two related to the procedure and three late deaths with a median time of 362 days (range 205-628 days). No deaths were associated with transapical access. Echocardiographic follow up did not detect any late structural complications from occluder devices. CONCLUSIONS: Transapical access and closure with nitinol-based devices is feasible and facilitates complex interventions where coaxial forces are need for device delivery and alignment. The most common complication is bleeding and this should be kept in perspective when treating high-risk patients.


Assuntos
Cateterismo Cardíaco , Cardiopatias/terapia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Cateteres Cardíacos , Bases de Dados Factuais , Desenho de Equipamento , Feminino , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Dispositivo para Oclusão Septal , Resultado do Tratamento
3.
Circ Cardiovasc Interv ; 17(7): e013558, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38785079

RESUMO

BACKGROUND: Elevated aortic valve gradients are common after transcatheter aortic valve implantation for degenerated surgical aortic valve replacement bioprostheses, but their clinical impact is uncertain. METHODS: A total of 12 122 patients who underwent transcatheter aortic valve implantation-in-surgical aortic valve replacement from November 2011 to December 2019 in the Society of Thoracic Surgery/American College of Cardiology Transvalvular Therapeutics Registry were included. The primary outcome was a composite of 1-year all-cause mortality, stroke, myocardial infarction, or valve reintervention. Secondary outcomes included 1-year all-cause mortality, readmission, and change from baseline 12-question self-administered Kansas City Cardiomyopathy Questionnaire-Overall Summary Score. Due to nonlinearity observed with restricted cubic splines analysis, a Cox regression analysis with aortic valve mean gradient modeled as a spline-continuous variable (with 20 mm Hg as a cutoff) was used to study the 1-year composite outcome and mortality. RESULTS: The composite outcome occurred most frequently in patients with aortic valve mean gradient ≥30 and <10 mm Hg, as compared with those with 10 to 20 and 20 to 30 mm Hg ranges (unadjusted rates, 13.9%, 12.1%, 7.5%, and 6.5%, respectively; P=0.002). When the mean aortic valve gradient was ≥20 mm Hg, higher gradients were associated with greater risk of the 1-year composite outcome (adjusted hazard ratio, 1.02 [1.02-1.03] per mm Hg; P<0.001) and 1-year mortality (adjusted hazard ratio, 1.02 [1.00-1.03] per mm Hg; P=0.007). Whereas when the mean aortic valve gradient was <20 mm Hg, higher gradients were not significantly associated with the composite outcome (adjusted hazard ratio, 0.99 [0.98-1.003] per mm Hg; P=0.12) but were associated with lower 1-year mortality (adjusted hazard ratio, 0.98 [0.97-0.99] per mm Hg; P=0.007). CONCLUSIONS: The relationship between postprocedural aortic valve mean gradient after transcatheter aortic valve implantation-in-surgical aortic valve replacement and clinical outcomes is complex and nonlinear, with relatively greater adverse events occurring at low and high gradient extremes. Further study of factors mediating the relationship between postprocedural gradients and clinical outcomes, including low-flow states, is necessary.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Falha de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Feminino , Masculino , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Fatores de Risco , Resultado do Tratamento , Fatores de Tempo , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Medição de Risco , Desenho de Prótese , Hemodinâmica , Estados Unidos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA