Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pain Med ; 23(11): 1863-1868, 2022 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-35512411

RESUMO

INTRODUCTION: The zygapophyseal joints represent one possible cause for back pain. Therefore, many interventions are targeting the denervation of the facet joints. The aim of this study is to describe the course of the medial branch of the dorsal branch of the spinal nerve and its articular branches to the zygapophyseal joints in the segments T10-T12. METHODS: The medial branches in the thoracic segments T10-T12 were dissected in 20 Thiel embalmed cadavers. An Eschenbach magnifying glass (4.0× magnification) was used during dissection preserving the articular branches. The topography and the branching pattern of the medial branches was observed. RESULTS: The course of the nerves in the segments T10-T12 differed from each other because of the different osseous anatomy of each segment. The medial branch at the segment T10 crossed the tip of the transverse process in 28 of the 40 hemivertebral specimens. In the remaining cases it passed superior to the transverse process. At T11 the medial branch ran constantly through an osteofibrous canal. At the segment T12 the medial branches showed a similar course to the medial branches in the lumbar region. In many cases two articular branches, which arose from the medial branch were identified. CONCLUSIONS: The results of this study show a considerable anatomic variety at the segment T10. It also demonstrates that the transverse process is an important landmark to encounter the medial branch. Furthermore, the possibility of a double innervation of the facet joints should always be considered.


Assuntos
Nervos Espinhais , Articulação Zigapofisária , Humanos , Articulação Zigapofisária/inervação , Dor nas Costas , Região Lombossacral , Cadáver
2.
J Strength Cond Res ; 36(3): 710-716, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32168074

RESUMO

ABSTRACT: Takamori, S, Hamlin, MJ, Kieser, DC, King, D, Hume, P, Yamazaki, T, Hachiya, M, and Olsen, PD. Senior club-level rugby union player's positional movement performance using individualized velocity thresholds and accelerometer-derived impacts in matches. J Strength Cond Res 36(3): 710-716, 2022-Game demands of professional rugby union players have been well documented; however, there is minimal game demand information using individualized velocity thresholds and collision loads, particularly for amateurs. This study investigated movement patterns of 20 male amateur rugby players during 16 senior premier division one matches using global positioning system (GPS) devices sampling at 10 Hz. Derived GPS variables included distances, velocities, sprinting, and impacts. Data files from 86 player games (≥60 minutes of play per game) were categorized into broad (forwards and backs) and specific (front row, second row, back row, half back, inside back, and outside back) positional groups for analysis. It was most likely that backs covered more distance in the high-speed running (>60% maximal velocity) zone (502 ± 157 m) compared with forwards (238 ± 147 m) (100/0/0%, chances of positive/trivial/negative differences, effect size [ES] = 1.3), performed more striding (backs 1,116 ± 240, forwards 954 ± 240 m, 96/4/0%, ES = 0.5), and sprinting (backs 121 ± 58, forwards 90 ± 65 m, 93/7/0%, ES = 0.5). However, forwards had higher collision loads (35 ± 12 arbitrary units) compared with backs (20 ± 6, 99.9/0.1/0%, ES = 1.3) with back row forwards completing the highest collision load of any playing position (40 ± 13). Our example match movement performance and impact information is valuable to coaches and support staff in preparing player profiles for similar-level rugby players to help manage their workloads.


Assuntos
Desempenho Atlético , Futebol Americano , Corrida , Acelerometria , Sistemas de Informação Geográfica , Humanos , Masculino , Rugby
3.
Forensic Sci Med Pathol ; 18(1): 30-36, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34973121

RESUMO

Rifles are often involved in violent deaths such as homicide and suicide. Consequently, expert knowledge and experimental forensic investigations are important to clarify the nature of ballistic trauma when applied to the human head and neurocranium. This study investigated differences in entrance wound morphology with Synbone® spheres which are described as being comparable to human flat bones. A series of ballistic experiments were conducted using two different rifle calibers (5.56 × 45 mm and 7.62 × 39 mm Full Metal Jacket (FMJ)). Synbone® spheres were used for close-range 0.3 m simulated executions as well as at 25 m and 35 m to simulate urban and military engagements. Results were compared with previously published experimental studies using similar military ammunition. In our study, entry wound morphology closely resembles real forensic cases compared to exit wound and overall shape morphology independently of the distance and the caliber. Circumferential delamination was clearly visible with full metal jacket (FMJ) rounds, yielding similar damage pattern morphology to the human crania. This study documented the presence of hydraulic burst or shock in all ten rounds from all three distances. Krönlein shots were also observed in some cases. Synbone® spheres constitute an acceptable synthetic surrogate for ballistic experiments. The present study offers new initial data on the behavior of Synbone® proxies in ballistic testing of military ammunitions; FMJ gunshot injuries to the human head, for distances that have not previously been published, suggesting that efficient tests can take place under these conditions. Further research on experimental ballistics with a larger number of controlled factors and multiple repetitions is recommended to verify the results of this pilot study before applied in forensic simulations.


Assuntos
Armas de Fogo , Militares , Ferimentos por Arma de Fogo , Balística Forense/métodos , Humanos , Modelos Biológicos , Projetos Piloto , Crânio/lesões
4.
Int J Legal Med ; 135(3): 909-912, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32845356

RESUMO

INTRODUCTION: Synthetic skin simulants are used both in wound ballistics and forensic investigations and should display similar mechanical properties to human tissue and therefore need to be validated. It is recognised that skin simulants may have a significantly different performance when different backing combinations are used; therefore, it is essential to specify and control the backing material. Roebuck 1518 synthetic chamois (RBK) backed by 20% ballistic gelatin has been validated as a suitable skin simulant; this study looks at validating the RBK simulant when backed by 10% ballistic gelatin. METHODS: Two layers of RBK synthetic chamois backed by calibrated 10% ballistic gelatin were placed onto the long face of the block and secured. Steel spheres with various sectional densities were fired using a custom-made gas gun to determine the V50 of the simulants and compared with the predicted V50. RESULTS: The results demonstrate that for a sectional density between 2.1 and 6.6 g/cm2, the skin simulants backed by 10% gelatin are within the 35% error bounds predicted by James' patent equation. All samples had a close fit to the regression line (R2 = 0.9738), and a Spearman rho test indicates that there is a "strong" negative correlation between sectional density and the V50 (Rs =- 0.957, p = 0.00). CONCLUSIONS: This validation study confirms that RBK synthetic simulant backed by 10% gelatin is a suitable skin simulant when testing non-deforming projectiles with sectional densities ranging from 2.1 to 6.6 g/cm2. A predictive trend line also indicates that the skin simulant is suitable for non-deforming projectiles with sectional densities ranging from 0.6 to 20 g/cm2 although this needs to be confirmed.


Assuntos
Balística Forense , Modelos Biológicos , Pele/lesões , Animais , Gelatina , Humanos , Reprodutibilidade dos Testes , Rupicapra , Ferimentos por Arma de Fogo
5.
Int J Legal Med ; 135(2): 521-526, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32864715

RESUMO

BACKGROUND: In ballistic testing and forensic reconstruction, there is a need to use repeatable and consistent simulants. While synthetic bone is mechanically similar to human bone, it does not have the same viscoelastic properties. In high-energy impact such as ballistic impacts, bone acts as a stiff, brittle material and fails instantaneously. Therefore, a suitable simulant for use in ballistic testing should have comparable energy deposition to mammalian bones. This preliminary study aims to determine if Synbone® could be a viable proxy for Sus scrofa (domesticus) ribs in ballistic testing. METHODOLOGY: Three thickness of Synbone® were embedded into 10% ballistic gelatin and shot using 5.56-mm ammunition. The models were then analysed to compare the Synbone® to a previous Sus scrofa (domesticus) rib study and focused on the number of fragments within the block, energy deposition, onset of yaw, angle of deviation, the temporary cavity as a percentage of the block and the depth to the temporary cavity centre, depth to maximum gelatin disruption and the permanent wound channel, including shear planes and wound tract diameter. RESULTS: There was no significant difference in the metrics that were compared between Sus scrofa (domesticus) ribs and the three thicknesses of Synbone®, except for a significant difference in the depth to maximum gelatin disruption between the 6 mm (p = 0.009) and 12 mm plate (p = 0.007) and the Sus scrofa (domesticus) ribs. CONCLUSION: This study indicates that the 5-mm Synbone® plate is a suitable proxy for Sus scrofa (domesticus) ribs for use with 5.56-mm OTM ammunition in ballistic testing.


Assuntos
Balística Forense , Fenômenos Mecânicos , Modelos Biológicos , Poliuretanos , Costelas/lesões , Animais , Sus scrofa , Ferimentos por Arma de Fogo
6.
Forensic Sci Med Pathol ; 17(4): 665-669, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34495451

RESUMO

Forensic reconstructions and ballistic testing requires the use of consistent and repeatable simulants. Synthetic bone has been developed to be mechanically similar to human bone; however, it does not have the same viscoelastic properties. Bone acts as brittle and stiff material and fails instantly under high-energy events such as ballistic impacts. Consequently, bone simulants for use in ballistic testing should show comparable energy deposition to mammalian bones. This study aims to determine if Synbone® flat plates could be a viable proxy for Sus scrofa (domesticus) ribs in ballistic testing with 7.62 × 51 mm Full Metal Jacket ammunition. 5 mm, 6 mm and 12 mm quartered Synbone® plates were embedded into 10% ballistic gelatin and shot using 7.62 mm ammunition. The models were then analysed to compare the Synbone® to a previous Sus Scrofa (domesticus) rib study and focused on energy deposition, the number of fragments within the block, angle of deviation, onset of yaw, the temporary cavity, and the permanent wound channel. No significant difference was seen between the Sus Scrofa (domesticus) and the 5 mm Sybone®. There were significant differences observed between Sus Scrofa (domesticus) ribs and 6 mm Synbone® for the number of fragments, energy deposition and projectile tract diameter, and significant differences seen between Sus scrofa (domesticus) ribs and 12 mm Synbone® for the depth of onset of yaw, energy deposition and projectile tract diameter. This study indicates that the 5 mm Synbone® plate is a suitable proxy for Sus scrofa (domesticus) ribs for use with 7.62 × 51 mm FMJ ammunition in ballistic testing.


Assuntos
Sus scrofa , Ferimentos por Arma de Fogo , Animais , Balística Forense , Humanos , Modelos Biológicos , Costelas/lesões , Suínos
7.
Clin Orthop Relat Res ; 478(3): 581-589, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31714411

RESUMO

BACKGROUND: Recurrent dislocation after THA remains a serious complication that carries with it a high risk of revision surgery. Previous studies have shown reduced dislocation rates with the use of lipped polyethylene (PE) liners in modular uncemented acetabular components, but there may be increased wear because of impingement, which may lead to aseptic loosening in the longer term; whether the aggregate benefit of lipped PE liners outweighs the risks associated with their use remains controversial. QUESTIONS/PURPOSES: We used data from the New Zealand Joint Registry to (1) compare Kaplan-Meier survival rates, (2) rates of revisions for dislocation between neutral and lipped PE liners, and (3) revision rates for aseptic loosening for the four most commonly used modular uncemented cups. METHODS: We used data from the New Zealand Joint Registry (NZJR) to identify 31,247 primary THAs using the four most commonly used uncemented modular acetabular implants from January 1, 1999 to December 31, 2018. The lipped liner group comprised 49% males (9924 of 20,240) compared with 42% (4669 of 11,007) in the neutral group (p < 0.001); 96% (19,382 of 20,240) of patients in the liner group had OA versus 95% (10,450 of 11,007) in the neutral group (p < 0.001). There was no difference in other patient characteristics such as age (mean 66.9 years), BMI (mean 29 ± 6 kg/m) and American Society of Anesthesiologists grade. The mean follow-up was 5.1 years (SD 3.9) and longest follow-up 19.3 years. The NZJR has more than 96% capture rate and data entry is a mandatory requirement of members of the New Zealand Orthopaedic Association. Kaplan-Meier survival rates were compared between 20,240 lipped and 11,007 neutral PE liners. Highly cross-linked polyethylene was used in 99% of lipped liner cups and 85% of neutral liner cups. Associated hazard ratios were calculated using a Cox regression analysis with a Kaplan-Meier revision-free estimates plot. RESULTS: The Kaplan-Meier survival at 10 years for lipped PE liners was 96% (95% confidence interval 95.4 to 96.2) and for neutral liners 95% (95% CI 94.7 to 95.9). After controlling for age, gender approach, femoral head size, and the use of image guidance, the all-cause revision risk was greater for neutral PE liners than that for lipped PE liners (HR 1.17 [95% CI 1.06 to 1.36]; p = 0.032). There was a higher risk of revision for dislocation in those with neutral PE liners than in those with lipped liners (HR 1.84 [95% CI 1.41 to 2.41]; p < 0.001) but no difference in the revision rate for aseptic acetabular component loosening (HR 0.85 [95% CI 0.52 to 1.38]; p = 0.511). CONCLUSIONS: The use of a lipped PE liner is not associated with a higher rate of aseptic loosening in patients who undergo primary THA compared with a neutral PE liner. Lipped PE liners are associated with lower rates of dislocation and lower all-cause revision rates without any increased association with revision rates for wear and aseptic loosening. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Desenho de Prótese/efeitos adversos , Reoperação/estatística & dados numéricos , Idoso , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Polietileno , Modelos de Riscos Proporcionais , Sistema de Registros , Fatores de Risco
8.
Int Wound J ; 17(3): 729-734, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32072770

RESUMO

Assess the outcome of a standardised protocol for the treatment of post-operative wound infection in patients undergoing deformity correction for neuro-muscular scoliosis (NMS). Retrospective review of 443 consecutive patients with a minimum 18 months' follow-up, following a primary posterior deformity correction for NMS. In patients who developed a wound complication, the patient demographic and comorbidities, causative pathogen, number of re-operations, length of stay (LOS), rate of cure, and complications were analysed. Forty-four patients (9.9%) developed a wound infection. Marginally more infections were mono-microbial (23) than poly-microbial (21). Coagulase negative staphylococcus and Staphylococcus aureus were the most commonly cultured pathogens. Seventeen patients were treated with antibiotics alone, while 27 patients also required surgical debridement. The average LOS for those treated with antibiotics alone was 12 days (range: 9-15 days), in contrast to those requiring debridement, which was 35 days (range: 35-70 days). All patients were cured from their infection and ultimately achieved fusion. Infection is common in NMS deformity correction. This is marginally more common as a mono-microbial than poly-microbial infection with most pathogens being staphylococcal in origin. Our defined treatment strategy resulted in a cure for all patients and capacity for all patients to achieve fusion.


Assuntos
Escoliose/cirurgia , Deiscência da Ferida Operatória/microbiologia , Deiscência da Ferida Operatória/terapia , Infecção da Ferida Cirúrgica/microbiologia , Infecção da Ferida Cirúrgica/terapia , Adolescente , Antibacterianos/uso terapêutico , Criança , Protocolos Clínicos , Desbridamento , Feminino , Humanos , Tempo de Internação , Masculino , Reoperação , Estudos Retrospectivos , Escoliose/etiologia , Deiscência da Ferida Operatória/diagnóstico , Infecção da Ferida Cirúrgica/diagnóstico , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
9.
Medicina (Kaunas) ; 56(10)2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33053880

RESUMO

Background and objectives: The subscapularis muscle is typically innervated by two distinct nerve branches, namely the upper and lower subscapular nerve. These usually originate from the posterior cord of the brachial plexus. A large number of variations have been described in previous literature. Materials and Methods: Dissection was carried out in 31 cadaveric specimens. The frequency of accessory subscapular nerves was assessed and the distance from the insertion points of these nerves to the myotendinous junction was measured. Results: Accessory subscapular nerves were found in three cases (9.7%). According to their origin from the posterior cord of the brachial plexus proximal to the thoracodorsal nerve all three nerves were identified as accessory upper subscapular nerves. No accessory lower subscapular nerves were found. Conclusion: Accessory nerves occur rather commonly and need to be considered during surgery, nerve blocks, and imaging procedures.


Assuntos
Plexo Braquial , Manguito Rotador , Plexo Braquial/diagnóstico por imagem , Humanos , Pesquisa , Tendões
10.
BMC Surg ; 19(1): 24, 2019 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-30786888

RESUMO

BACKGROUND: Monobloc resection of soft tissue sarcomas (STSs) has a major impact on overall survival and local recurrence. Anatomical boundaries, such as the sciatic notch, increase the risk of fragmentation of the lesion. To date there are few papers describing the optimal surgical technique to remove such STSs. The objective of this study is to describe a simultaneous anterior and posterior approach for resection of sciatic notch dumbbell tumours. CASE PRESENTATION: We present the surgical management of two patients diagnosed with well-differentiated liposarcomas of the sciatic notch with a retroperitoneal and gluteal extension in the two cases. Pre-operative diagnosis was made with a percutaneous biopsy including molecular analysis which demonstrated MDM2 amplification. We describe a simultaneous anterior and posterior approach, including the ligation of the posterior trunk of the internal iliac artery, to reduce intra-operative blood loss and devascularise the tumour. The anterior approach allows the evaluation of the tumour's retroperitoneal extension, release from its pelvic attachments and control of the surrounding neurovascular structures. During the posterior approach, bleeding is reduced by the devascularisation of the gluteal musculature achieved with internal iliac artery ligation. Clear margins were achieved in both cases. No vascular, skeletal or soft tissue reconstructions were required. CONCLUSIONS: Simultaneous combined anterior and posterior approaches to remove a malignant sciatic notch tumour optimises the chance of complete en bloc resection. This surgical strategy allows oncologic en bloc resection with minimal blood loss.


Assuntos
Lipossarcoma/cirurgia , Neoplasias Retroperitoneais/cirurgia , Neoplasias de Tecidos Moles/cirurgia , Adulto , Nádegas , Feminino , Humanos , Artéria Ilíaca/cirurgia , Ílio , Lipossarcoma/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/irrigação sanguínea , Músculo Esquelético/cirurgia , Neoplasias Retroperitoneais/diagnóstico por imagem , Neoplasias de Tecidos Moles/diagnóstico por imagem
11.
Surg Radiol Anat ; 41(6): 607-611, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30937565

RESUMO

PURPOSE: To describe the origin of the vessels supplying the anterior sub-axial cervical vertebrae (C3-C7) to further understand their potential influence on anterior bone loss after anterior cervical spinal surgery. METHOD: Cadaveric dissection was performed on ten adult human necks after latex perfusion of their subclavian, common carotid and vertebral arteries. The nutrient vessels of the sub-axial cervical spine were identified and traced to their origin. The course and distribution of these vessels and their nutrient foraminae are described. RESULTS: In all cases the anterior nutrient vessels were derived from the thyro-cervical trunk with branches that passed over the longus coli muscles forming a leash of vessels in the pre-vertebral fascia which subsequently extended in a frond-like pattern to pass onto the anterior aspect of vertebrae. The more cranial the cervical level the fewer the number of nutrient vessels and foraminae. The distribution of the foraminae on the anterior vertebral body followed the oblique supero-medial course of the nutrient vessels. CONCLUSION: Nutrient vessels perforate the cervical vertebrae on their anterior surface. These are derived from a leash of vessels that lie within the pre-vertebral fascia overlying the longus coli muscles. The origin of these vessels is the ascending cervical artery with a variable contribution from the transverse cervical artery.


Assuntos
Vértebras Cervicais/irrigação sanguínea , Artéria Vertebral/anatomia & histologia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Humanos
12.
Int Wound J ; 16(6): 1553-1558, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31606949

RESUMO

Wound closure after wide, local excision of an appendicular soft-tissue sarcoma (STS) can be challenging. This study evaluates the value of magnetic resonance imaging (MRI)-based tumour parameters in planning wound closure. A total of 71 patients with a primary limb-based STS, excluding vascular or osseous involvement, excluding the shoulder or hand and hip or foot were included. Axial MRI images were used to measure the circumferences and cross-sectional areas of the limb, bone, and tumour. The tumour diameter, length, and depth at the level of maximal tumour dimension were measured to identify the tumour's relative contribution to the planning of optimal wound closure management through primary closure (PC) or reconstructive surgery (RS). Eighteen patients required planned wound RS. Wound complications occurred in 14% overall. Tumours, which were closed by PC, were of significantly greater depth, shorter radial diameter, and shorter tumour circumference relative to those closed by RS. On multivariate analysis, tumour depth was the greatest contributory factor in predicting type of wound closure. A quantitative analysis of MRI-based tumour parameters demonstrates tumour depth as the most predictive factor in planning for the type of wound closure and may prove beneficial in providing greater insight into planned wound management of sarcoma resection.


Assuntos
Drenagem , Tratamento de Ferimentos com Pressão Negativa , Sarcoma/cirurgia , Neoplasias de Tecidos Moles/cirurgia , Suturas , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Sarcoma/diagnóstico por imagem , Neoplasias de Tecidos Moles/diagnóstico por imagem
13.
Eur Spine J ; 27(6): 1201-1206, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29541850

RESUMO

PURPOSE: Hirayama disease is an initially progressive disease caused by cervical neck flexion compressing the anterior horns of the lower cervical spinal cord. It is primarily seen in young males of Indian or Asian descent. With increasing dispersion of these populations this condition is increasingly being encountered internationally. This grand round reviews this rare but increasingly recognized condition. MATERIALS AND METHODS: We present a classic case of a young Indian male with progressive hand and forearm weakness. We discuss the typical clinical presentation, appropriate investigations and management of this condition. RESULTS: Our patient presented with oblique amyotrophy and underwent a diagnostic flexion MRI scan which revealed anterior translation of the posterior dura with compression of the anterior horns of the lower cervical cord. He has been successfully treated in a cervical collar. CONCLUSIONS: This case illustrates the typical presentation, diagnostic investigations and treatment of Hirayama syndrome. It is hoped that this review will alert clinicians of this condition and optimize the management of affected individuals.


Assuntos
Medula Cervical/patologia , Atrofias Musculares Espinais da Infância/diagnóstico , Braquetes , Vértebras Cervicais/patologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pescoço/diagnóstico por imagem , Pescoço/patologia , Compressão da Medula Espinal/etiologia , Compressão da Medula Espinal/terapia , Atrofias Musculares Espinais da Infância/complicações , Atrofias Musculares Espinais da Infância/terapia , Adulto Jovem
14.
Eur Spine J ; 27(Suppl 3): 446-452, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29356985

RESUMO

PURPOSE: To present a case of aggressive sacral osteoblastoma (OB) treated with neoadjuvant denosumab therapy and en bloc resection. METHODS: Case report of a 14-year-old male with an aggressive OB affecting the superior articular process of the left first sacral segment. The lesion was lytic and metabolically active and involved the left-sided posterior elements of S1-S3 with extension into the spinal canal, affecting the left S1, S2, S3, S4 and S5 nerve roots. He was treated for 1 month with neoadjuvant denosumab followed by en bloc resection. RESULTS: Denosumab therapy caused regression of the tumour and converted the diffuse infiltrative mass into a well-defined solid (osteoma-like) structure, aiding surgical resection and preserving the S1, S4 and S5 nerve roots. Histologically, the treated lesion showed abundant sclerotic woven bone and osteoblasts with absence of osteoclasts. CONCLUSIONS: A short course of denosumab caused tumour regression, ossification and conversion of an aggressive OB into a sclerotic, well-defined lesion thus aiding surgical resection and preservation of neural structures. Neoadjuvant therapy reduced osteoclast numbers but PET showed that the lesion remained FDG avid post-therapy.


Assuntos
Conservadores da Densidade Óssea/administração & dosagem , Neoplasias Ósseas/tratamento farmacológico , Denosumab/administração & dosagem , Osteoblastoma/tratamento farmacológico , Adolescente , Neoplasias Ósseas/cirurgia , Humanos , Masculino , Terapia Neoadjuvante/métodos , Osteoblastoma/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Sacro/patologia , Sacro/cirurgia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
15.
Eur Spine J ; 27(4): 851-858, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29356986

RESUMO

PURPOSE: To assess the efficacy of bisphosphonate therapy in the management of spinal aneurysmal bone cysts (ABCs). METHODS: A prospective study of six consecutive patients aged between 7 and 22 years with spinal ABCs treated with pamidronate (1 mg/kg) or zoledronate (4 mg). A visual analogue scale (VAS) for pain and radiological (contrast-enhanced MRI and CT scan at 3 and 6 months, then yearly X-rays) follow-up was continued for a minimum of 6 years. RESULTS: One patient with an unstable C2/3 failed to respond to a single dose of bisphosphonate and required surgical resection and stabilisation with autologous bone grafting. Another, with a thoraco-lumbar ABC, experienced progression of neurological dysfunction after one cycle of bisphosphonate and, therefore, required surgical resection and stabilisation. In all other patients pain progressively improved and was resolved after two to four cycles (VAS 7.3-0). These patients all showed reduction in peri-lesional oedema and increased ossification by 3 months. No patients have had a recurrence within the timeframe of this study. CONCLUSIONS: Bisphosphonate therapy can be used as the definitive treatment of spinal ABCs, except in patients with instability or progressive neurology, where surgical intervention is required. Clinicians should expect a patients symptoms to rapidly improve, their bone oedema to resolve by 3 months and their lesion to partially or completely ossify by 6-12 months.


Assuntos
Cistos Ósseos Aneurismáticos/tratamento farmacológico , Conservadores da Densidade Óssea/uso terapêutico , Difosfonatos/uso terapêutico , Doenças da Coluna Vertebral/tratamento farmacológico , Coluna Vertebral/patologia , Adolescente , Adulto , Conservadores da Densidade Óssea/efeitos adversos , Criança , Difosfonatos/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Medição da Dor , Estudos Prospectivos , Adulto Jovem
16.
J Arthroplasty ; 32(11): 3484-3487, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28668211

RESUMO

BACKGROUND: Liner exchange for articular component wear in total hip joint replacements (THJRs) is a common procedure, often thought to be benign with reliable outcomes. Recent studies, however, suggest high failure rates of liner exchange revisions with significant complications. The primary aim of this study was, therefore, to analyze the survivorship of isolated liner exchange for articular component wear, and secondarily to assess the influence of patient demographics (gender, age, and American Society of Anaesthesiologists [ASA] ratings) on rerevisions following isolated liner exchange for wear. METHODS: A retrospective review of the 15-year New Zealand Joint Registry (1999-2014) was performed, analyzing the outcomes of isolated liner exchange for articular component wear. The survivorship as defined as rerevision with component exchange was determined and 10-year Kaplan-Meier survivorship curves were constructed. These revision rates were compared to age, gender, and ASA rating groups using a log-rank test. RESULTS: The 10-year survivorship of THJR following liner exchange revision for liner wear was 75.3%. If a rerevision was required, the median time to rerevision was 1.33 years with a rerevision rate of 3.33 per 100 component years (95% confidence interval 2.68-4.08/100 component years). The principle reasons for rerevision were dislocation (48.4%) and acetabular component loosening (20.9%). There was no statistically significant difference in rerevision rates based on gender, age categories, or ASA scores. CONCLUSION: THJR isolated liner exchange for liner wear is not a benign procedure with a survivorship of 75.3% at 10 years. Surgeons contemplating liner exchange revisions should be cognisant of this risk and should adequately assess component position and stability preoperatively.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Sistema de Registros , Reoperação/estatística & dados numéricos , Acetábulo/cirurgia , Idoso , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Desenho de Prótese , Falha de Prótese , Reoperação/efeitos adversos , Estudos Retrospectivos
17.
J R Army Med Corps ; 159(4): 294-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24109096

RESUMO

INTRODUCTION: Indirect ballistic fractures occur when a projectile passes close to, but not contacting, the bone. The mechanism of how these fractures occur is not yet proven, but recently the acoustic shockwave has been excluded as a cause. The objective of this study is to determine whether the expanding temporary cavity, the collapse of this cavity or its oscillation causes these fractures. In addition, we describe the fracture morphology and biomechanical causes of this injury. METHOD: 40 fresh deer femora were strain gauged and embedded in ballistic gelatin before being shot with four different projectiles with varying distances off the bone. Pressure recordings, chronographs and radar allowed assessment of local pressures and energy transfer. High-speed video allowed the temporal relationship between the temporary cavity and fracture formation to be analysed, while sample dissection allowed the fracture morphology to be described. RESULTS: The fractures produced were consistently wedge-shaped and caused by the expansion of the temporary cavity, flexing the bone beyond its yield point, causing tension failure on the cortex opposite the expanding temporary cavity and a compression wedge on the side of the cavity. Local pressure was not predictive of fracture formation but the energy transfer to the gelatin block was predictive. CONCLUSIONS: Indirect fractures are caused by the expansion of the temporary cavity and relate to the proximity of this cavity to the bone. Fractures occur from flexion of the bone and classically display wedge-shaped fracture patterns with the apex of the wedge pointing away from the expanding cavity.


Assuntos
Fraturas do Fêmur , Ferimentos por Arma de Fogo , Transferência de Energia , Fêmur , Pressão
18.
Biomech Model Mechanobiol ; 22(1): 123-132, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36121529

RESUMO

Spinal fixation and fusion are surgical procedures undertaken to restore stability in the spine and restrict painful or degenerative motion. Malpositioning of pedicle screws during these procedures can result in major neurological and vascular damage. Patient-specific surgical guides offer clear benefits, reducing malposition rates by up to 25%. However, they suffer from long lead times and the manufacturing process is dependent on third-party specialists. The development of a standard set of surgical guides may eliminate the issues with the manufacturing process. To evaluate the feasibility of this option, a statistical shape model (SSM) was created and used to analyse the morphological variations of the T4-T6 vertebrae in a population of 90 specimens from the Visible Korean Human dataset (50 females and 40 males). The first three principal components, representing 39.7% of the variance within the population, were analysed. The model showed high variability in the transverse process (~ 4 mm) and spinous process (~ 4 mm) and relatively low variation (< 1 mm) in the vertebral lamina. For a Korean population, a standardised set of surgical guides would likely need to align with the lamina where the variance in the population is lower. It is recommended that this standard set of surgical guides should accommodate pedicle screw diameters of 3.5-6 mm and transverse pedicle screw angles of 3.5°-12.4°.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Masculino , Feminino , Humanos , Vértebras Torácicas/anatomia & histologia , Vértebras Torácicas/cirurgia , Fusão Vertebral/métodos
19.
Biomater Sci ; 12(1): 134-150, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-37933486

RESUMO

Synthetic polymers, such as poly(vinyl alcohol) (PVA), are popular biomaterials for the fabrication of hydrogels for tissue engineering and regenerative medicine (TERM) applications, as they provide excellent control over the physico-chemical properties of the hydrogel. However, their bioinert nature is known to limit cell-biomaterial interactions by hindering cell infiltration, blood vessel recruitment and potentially limiting their integration with the host tissue. Efforts in the field have therefore focused on increasing the biofunctionality of synthetic hydrogels, without limiting the advantages associated with their tailorability and controlled release capacity. The aim of this study was to investigate the suitability of pristine gelatin to enhance the biofunctionality of tyraminated PVA (PVA-Tyr) hydrogels, by promoting cell infiltration and host blood vessel recruitment for TERM applications. Pure PVA-Tyr hydrogels and PVA-Tyr hydrogels incorporated with vascular endothelial growth factor (VEGF), a well-known pro-angiogenic stimulus, were used for comparison. Incorporating increasing concentrations of VEGF (0.01-10 µg mL-1) or gelatin (0.01-5 wt%) did not influence the physical properties of PVA-Tyr hydrogels. However, their presence within the polymer network (>0.1 µg mL-1 VEGF and >0.1 wt% gelatin) promoted endothelial cell interactions with the hydrogels. The covalent binding of unmodified gelatin or VEGF to the PVA-Tyr network did not hamper their inherent bioactivity, as they both promoted angiogenesis in a chick chorioallantoic membrane (CAM) assay, performing comparably with the unbound VEGF control. When the PVA-Tyr hydrogels were implanted subcutaneously in mice, it was observed that cell infiltration into the hydrogels was possible in the absence of gelatin or VEGF at 1- or 3-weeks post-implantation, highlighting a clear difference between in vitro an in vivo cell-biomaterial interaction. Nevertheless, the presence of gelatin or VEGF was necessary to enhance blood vessel recruitment and infiltration, although no significant difference was observed between these two biological molecules. Overall, this study highlights the potential of gelatin as a standalone pro-angiogenic cue to enhance biofunctionality of synthetic hydrogels and provides promise for their use in a variety of TERM applications.


Assuntos
Álcool de Polivinil , Fator A de Crescimento do Endotélio Vascular , Camundongos , Animais , Álcool de Polivinil/química , Gelatina/química , Engenharia Tecidual , Hidrogéis/química , Polímeros/química , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/química , Etanol
20.
Hip Int ; 32(1): 73-79, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32340486

RESUMO

BACKGROUND: 3D-printed or additive manufactured acetabular implants are an exciting new technology being used in hip surgery with increasing frequency especially in complex acetabular reconstructions. However, the performance of acetabular components produced by this method for primary THR is unknown. METHODS: 41,272 uncemented cups in primary THR for OA were identified in the NZJR for the purposed of this study. There were 39,080 uncemented cups in the control group (15,798 Pinnacle cups, 12,724 Trident cups and 10,558 RM Pressfit cups) compared to 2192 3D-printed uncemented implants (1397 Delta TT cups, 640 Ti Por and 155 Polymax cups). All-cause revision rates and reasons for revision were examined. Kaplan-Meier survival analysis was performed. RESULTS: 3D-printed cups were inserted into younger, fitter patients with a higher mean BMI compared to those in the control group (p < 0.001). The overall all-cause revision rate for 3D-printed cups was not significantly different to the controls: 0.77/100 cys (95% CI 0.59-1) compared to 0.55/100 cys (95% CI 0.52-0.58) in the control group (p = 0.058, Hazards ratio 1.29, 95% CI 0.992-1.678). There was no difference in aseptic cup loosening or deep infection rates between either group or indeed individual implant designs. CONCLUSIONS: 3D-printed uncemented cups provide reliable survivorship and clinical results in primary THR comparable to established designs manufactured by traditional means. The theoretical concerns of increased rates of fatigue failure or deep infection are unsubstantiated.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Humanos , Nova Zelândia/epidemiologia , Impressão Tridimensional , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA